1.
Eur J Pediatr ; 183(8): 3445-3452, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38771372

RESUMO

The aim of this study is to analyse the diagnostic value of bone marrow aspiration (BMA) in a retrospective cohort of patients with suspected immune thrombocytopaenia (ITP). We further measure changes in the percentage of patients who underwent this study and whether testing or not was in accordance with current guidelines at the time of diagnosis. We conducted a chart review of 243 patients with ITP who underwent follow-up in our institution between 1995 and 2022. The patients were divided into historical cohorts based on the practice guidelines of the Spanish Society of Pediatric Hematology and Oncology (SEHOP) and the American Society of Hematology (ASH) in place at the time of follow-up. For each case, time of disease presentation or initial diagnosis was defined as that which occurred in the first 72 h following disease onset. Based on data from the historical cohorts studied, we observed a lower total number of BMAs at diagnosis over time (p < 0.005). A gradual reduction was seen in the number of BMAs with the introduction of guidelines, including a progressively lower number of BMAs performed without indication (p < 0.05). Subsequent to the initial diagnosis, the procedure played a decisive role in only 2 patients (0.58%), allowing for a diagnosis of acquired aplastic anaemia in both cases. In both of them on diagnosis, BMA did not appear to be indicated, although subsequent analysis after 72 h raised suspicion of bone marrow failure. CONCLUSION: BMA at presentation did not significantly alter the diagnosis in our cohort of patients with an initial suspicion of ITP, although the procedure was decisive in diagnosing 2 cases of acquired aplastic anaemia during the subsequent course of the disease. Regarding the number of aspirations performed, our findings show that increased physician compliance with current guidelines reduced the rate of unnecessary BMAs. WHAT IS KNOWN: • BMA is a supplementary test for the diagnosis of ITP. • The usefulness of this invasive diagnostic procedure is not clearly stated in current guidelines. WHAT IS NEW: • Adjustments to scientific guidelines have led to a reduction in the number of BMAs performed on our patients with suspected ITP in the last 27 years. • While the risks and benefits of BMA at the time of diagnosis are unclear in patients with suspected ITP, the procedure does not contribute significant information to support the diagnosis.


Assuntos
Fidelidade a Diretrizes , Púrpura Trombocitopênica Idiopática , Humanos , Estudos Retrospectivos , Púrpura Trombocitopênica Idiopática/diagnóstico , Feminino , Criança , Masculino , Pré-Escolar , Fidelidade a Diretrizes/estatística & dados numéricos , Adolescente , Exame de Medula Óssea/métodos , Lactente , Guias de Prática Clínica como Assunto , Medula Óssea/patologia , Seguimentos
2.
Vox Sang ; 117(10): 1220-1229, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36102135

RESUMO

BACKGROUND AND OBJECTIVES: Extracorporeal photopheresis (ECP) has been shown to be an effective treatment for graft-versus-host disease (GvHD). However, information regarding lymphocyte collection for ECP in children is limited. The aim of this study was to analyse and compare lymphocyte collection for ECP in children using different devices and protocols. Moreover, we have studied both safety and variables of the infused product related to treatment efficacy. PATIENTS AND METHODS: This was a retrospective study of 91 patients who underwent 1524 apheresis procedures with either the COBE Spectra or Spectra Optia system. The comparison study between the Optia protocols (MNC and CMNC) was prioritized. We analysed 578 procedures using the Optia blood cell separator: 204 and 374 using the MNC and the CMNC protocol, respectively. RESULTS: The Optia CMNC protocol showed better collection efficiency, with increased lymphocyte collection per kg of body weight (p < 0.001). On multivariate analysis, the type of protocol showed no relationship with haematocrit or platelet loss. Most procedures were well-tolerated, with the most frequent adverse events related to venous access (21.7%). Seventy-one percent of patients had either partial or complete clinical GvHD response. In the multivariate model, only two variables were associated with a better response to ECP, younger age and a greater increase of B lymphocytes after treatment. CONCLUSION: Lymphocyte collection for ECP is well-tolerated in most children, achieving complete or partial response in more than half of GvHD patients. CMNC is the optimal software to perform lymphocyte collection in children.


Assuntos
Remoção de Componentes Sanguíneos , Doença Enxerto-Hospedeiro , Fotoferese , Remoção de Componentes Sanguíneos/métodos , Criança , Doença Enxerto-Hospedeiro/terapia , Humanos , Leucócitos Mononucleares , Fotoferese/métodos , Estudos Retrospectivos