Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Clin Infect Dis ; 74(10): 1812-1820, 2022 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-34409431

RESUMO

BACKGROUND: The impact of remdesivir (RDV) on mortality rates in coronavirus disease 2019 (COVID-19) is controversial, and the mortality effect in subgroups of baseline disease severity has been incompletely explored. The purpose of this study was to assess the association of RDV with mortality rates in patients with COVID-19. METHODS: In this retrospective cohort study we compared persons receiving RDV with those receiving best supportive care (BSC). Patients hospitalized between 28 February and 28 May 2020 with laboratory-confirmed severe acute respiratory syndrome coronavirus 2 infection were included with the development of COVID-19 pneumonia on chest radiography and hypoxia requiring supplemental oxygen or oxygen saturation ≤94% with room air. The primary outcome was overall survival, assessed with time-dependent Cox proportional hazards regression and multivariable adjustment, including calendar time, baseline patient characteristics, corticosteroid use, and random effects for hospital. RESULTS: A total of 1138 patients were enrolled, including 286 who received RDV and 852 treated with BSC, 400 of whom received hydroxychloroquine. Corticosteroids were used in 20.4% of the cohort (12.6% in RDV and 23% in BSC). Comparing persons receiving RDV with those receiving BSC, the hazard ratio (95% confidence interval) for death was 0.46 (.31-.69) in the univariate model (P < .001) and 0.60 (.40-.90) in the risk-adjusted model (P = .01). In the subgroup of persons with baseline use of low-flow oxygen, the hazard ratio (95% confidence interval) for death in RDV compared with BSC was 0.63 (.39-1.00; P = .049). CONCLUSION: Treatment with RDV was associated with lower mortality rates than BSC. These findings remain the same in the subgroup with baseline use of low-flow oxygen.


Assuntos
Tratamento Farmacológico da COVID-19 , Monofosfato de Adenosina/análogos & derivados , Alanina/análogos & derivados , Humanos , Oxigênio , Estudos Retrospectivos , SARS-CoV-2
2.
J Vasc Surg Cases Innov Tech ; 8(1): 19-22, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35024524

RESUMO

Bacillus Calmette-Guérin (BCG) vaccine has been successfully used to treat bladder cancer. However, sporadic cases of mycotic arterial aneurysms have been reported. These patients typically develop a Mycobacterium bovis infection of an existing aneurysm or graft. In the present report, we have described the case of a patient with a ruptured nonaneurysmal abdominal aorta years after intravesicular BCG therapy. Emergent aortic endograft repair was successful. After subsequent evaluation confirmed M. bovis infection, the patient was treated with a prolonged course of antimycobacterial therapy. Vascular surgeons should maintain suspicion for atypical aortic ruptures in patients with exposure to intravesicular BCG therapy.

3.
Ann Thorac Surg ; 74(5): 1700-2, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12440639

RESUMO

Pulmonary vasospasm and hypertension may occur after repair or palliation of congenital cardiac defects, and can be fatal in spite of conventional treatment. Nitric oxide has been shown to improve pulmonary hypertension unresponsive to conventional measures after a variety of repairs, but use has infrequently been reported after palliative systemic to pulmonary artery shunts. We report a case of pulmonary hypertension and life threatening desaturation after a modified Blalock-Taussig shunt that responded rapidly to inhaled nitric oxide. Clinical use, further study, and prospective analysis of prophylactic use of nitric oxide appear warranted.


Assuntos
Anomalias dos Vasos Coronários/cirurgia , Hipertensão Pulmonar/tratamento farmacológico , Óxido Nítrico/administração & dosagem , Complicações Pós-Operatórias/tratamento farmacológico , Artéria Pulmonar/cirurgia , Tetralogia de Fallot/cirurgia , Vasoconstrição/efeitos dos fármacos , Administração por Inalação , Feminino , Humanos , Lactente , Cuidados Paliativos , Artéria Pulmonar/efeitos dos fármacos , Artéria Subclávia/cirurgia
4.
Ultrasound Med Biol ; 28(11-12): 1389-93, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12498933

RESUMO

As compared with two-dimensional (2-D) transesophageal echocardiography (TEE), 3-D echocardiography now permits more realistic visualization of cardiac anatomy and of intracardiac lesions. The aim of this study was to apply newer 3-D echocardiographic techniques to quantify volumes of intracardiac masses undergoing surgical resection seen during an intraoperative TEE. The calculated volumes were compared with actual in vitro measurements of surgically resected masses. A total of 14 patients (9 men; 5 women; age range between 21 and 77 years) with intracardiac mass lesions (4 tumors: 3 left atrial myxomas and 1 mitral valve fibroelastoma, and 10 vegetations: 5 aortic valve, 3 mitral valve, 1 tricuspid and 1 pulmonary valve) were studied. Using commercially available 3-D reconstruction software (TomTec v. 4.1), the volumes of intracardiac masses were estimated using both the average rotation (rotation around the long axis, AR) and disk summation (parallel short axis cuts, DS) methods. Volumes of these lesions were also measured in vitro by water submersion. They ranged from 0.20 mL to 24 mL (mean +/- SD = 8.07 +/- 9.21 mL). Both 3-D TEE AR and 3-D TEE DS calculated volumes correlated excellently with in vitro measured volumes (r = 1.00 and r = 0.98, respectively, p = < 0.0001). The correlation between 3-D TEE AR and 3-D TEE DS calculated volumes was also excellent (r = 0.98, p = < 0.0001). In conclusion, the volume assessments by 3-D TEE of intracardiac mass lesions correlated well with in vitro measured volumes of surgical specimens. This technique may prove to be valuable in further defining intracardiac pathology and is a further advancement toward the application of clinically useful 3-D echocardiography.


Assuntos
Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Neoplasias Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico por imagem , Adulto , Idoso , Feminino , Neoplasias Cardíacas/patologia , Neoplasias Cardíacas/cirurgia , Doenças das Valvas Cardíacas/patologia , Doenças das Valvas Cardíacas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Mixoma/diagnóstico por imagem , Mixoma/patologia , Mixoma/cirurgia , Variações Dependentes do Observador
5.
Ultrasound Med Biol ; 29(5): 649-57, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12754064

RESUMO

The Sulzer Carbomedics prosthetic heart valve (CP) is a commonly used mechanical valve in clinical practice. In the present study, we used conventional and color Doppler echocardiography to assess the hemodynamics of normally functioning CP in the aortic (n = 73) and mitral (n = 127) positions. Our findings demonstrate no significant correlation of Doppler-measured peak and mean pressure gradients and effective orifice area with implanted valve size and actual orifice areas, measured directly by the manufacturer for CPs in both the mitral and aortic positions. However, it is still useful to measure effective orifice area by Doppler because a value in the normal or nonstenotic range points to an unobstructed prosthesis in the aortic or mitral position, in the absence of poor left ventricular ejection fraction. A value in the stenotic range could mean a normally functioning or obstructed prosthesis and, therefore, may need further investigation, such as assessment of valve leaflet motion by transthoracic or transesophageal echocardiography or fluoroscopy. Valve regurgitation as evaluated by color Doppler flow mapping was mild in practically all CPs in the aortic position, and in the majority of CPs in the mitral position.


Assuntos
Valva Aórtica/fisiopatologia , Próteses Valvulares Cardíacas , Valva Mitral/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Pressão Sanguínea , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Transesofagiana/métodos , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Falha de Prótese
6.
Echocardiography ; 13(4): 431-434, 1996 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11442951

RESUMO

This case report describes a patient with systemic lupus erythematosus who demonstrated by transesophageal echocardiography (TEE) a flail right coronary cusp of the aortic valve causing severe aortic regurgitation. This finding was confirmed at surgery, which showed near detachment of the right coronary leaflet near the commissure. Destruction of areas of the aortic valve has been reported in one previous case report in the absence of infective endocarditis or a traumatic process. This is the second case to our knowledge and the first to describe identification by TEE. (ECHOCARDIOGRAPHY, Volume 13, July 1996)

7.
Echocardiography ; 13(5): 503-510, 1996 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11442961

RESUMO

We describe our preliminary experience in assessing normal and stenosed coronary arteries using transesophageal three-dimensional echocardiography (3-D echo) in 27 adult patients. Multiplane transesophageal two-dimensional images of the coronary arteries (20 left, 3 right, 3 both left and right, and 1 posterior descending) were first acquired in the TomTec computer in 3 degrees sequential increments, from 0 degrees to 180 degrees, and then 3-D reconstruction was performed. The entire left main (LMC, measuring 0.5 to 1.7 cm, mean 1.0 cm) as well as variable lengths of proximal or both proximal and middle segments of the left anterior descending (LAD, measuring 0.2 to 2.5 cm, mean 0.8 cm) and circumflex (LCX, measuring 0.2 to 2.8 cm, mean 0.9 cm) coronary arteries together with some of their branches could be visualized in 3-D in 22 of 23 patients. In the remaining patient, the LMC was absent, and both LAD and LCX could be visualized in 3-D as having separate but adjacent origins from the left sinus of Valsalva (proven by angiography). In two patients, long segments of interventricular and great cardiac veins were also visualized accompanying the LAD and LCX, respectively. The right coronary artery (RCA, measuring 0.7 to 3.0 cm, mean 1.9 cm) was also successfully delineated in 3-D in all six patients in whom an attempt was made to visualize it during echo examination. Using the transgastric approach, a long (1.8 cm) segment of the posterior descending branch (PDA) of RCA was imaged in one patient. In addition, nine significantly stenotic lesions (>50% lumen diameter) were identified by 3-D in eight patients involving LMC (1), proximal LAD (1), mid LAD (1), proximal LCX (2), proximal RCA (3), and mid PDA (1). Eight of these 9 lesions were confirmed by coronary angiography. The remaining lesion (mid PDA) could not be confirmed since the patient did not undergo angiography. Our preliminary study demonstrates the usefulness of transesophageal 3-D echo not only in delineating normal coronary arteries but also diagnosing significant atherosclerotic stenosis in these vessels. (ECHOCARDIOGRAPHY, Volume 13, September 1996)

8.
Echocardiography ; 16(8): 835-837, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11175230

RESUMO

The incremental value of three-dimensional echocardiography over transesophageal multiplane two-dimensional imaging in the assessment of sinus venosus atrial septal defect is demonstrated in the present study.

9.
Am J Geriatr Cardiol ; 13(5): 279-84, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15365294

RESUMO

Aortic valve stenosis (AS) severity can be estimated by various modalities. Due to some of the limitations of the currently available methods, the usefulness of live three-dimensional transthoracic echocardiography (3D TTE) in the assessment of AS was explored. Live 3D TTE was able to visualize the aortic valve orifice in all 11 patients studied. Live 3D TTE correctly estimated the severity of AS in all 10 patients in whom AS severity could be evaluated at surgery. These included eight patients with severe AS and two with moderate AS. Two of these 10 patients with AS had associated hypertrophic cardiomyopathy and underwent myectomy at the time of aortic valve replacement. Aortic valve orifice area measurements by live 3D TTE correlated well with intraoperative three-dimensional transesophageal echocardiographic reconstruction measurements (r=0.85) but not as well with two-dimensional transesophageal echocardiography measurements (r=0.64). Live 3D TTE measurements of the aortic valve orifice area also did not correlate well with two-dimensional transthoracic echocardiography measurements (r=0.46) but the number of patients studied with two-dimensional transthoracic echocardiography was smaller (only seven) and four of these did not undergo two-dimensional transthoracic echocardiography at the authors' institution. Altogether, four patients with severe AS by live 3D TTE, and subsequently confirmed at surgery, were misdiagnosed as having moderate AS by two-dimensional transthoracic echocardiography. Because it is completely noninvasive and views the aortic valve in three dimensions, 3D TTE could be a useful complement to the existing modalities in the evaluation of AS severity.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia Tridimensional , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/epidemiologia , Ecocardiografia Doppler em Cores , Feminino , Humanos , Aumento da Imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Índice de Gravidade de Doença
14.
Cardiol Young ; 18(3): 328-36, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18460222

RESUMO

OBJECTIVE: In 1990, Fontan, Kirklin, and colleagues published equations for survival after the so-called "Perfect Fontan" operation. After 1988, we evolved a protocol using an internal or external polytetraflouroethylene tube of 16 to 19 millimetres diameter placed from the inferior caval vein to either the right or left pulmonary artery along with a bidirectional cava-pulmonary connection. The objective of this study was to test the hypothesis that a "perfect" outcome is routinely achievable in the current era when using a standardized surgical procedure. METHODS: Between 1 January, 1988, and 12 December, 2005, 112 patients underwent the Fontan procedure using an internal or external polytetraflouroethylene tube plus a bidirectional cava-pulmonary connection, the latter usually having been constructed as a previous procedure. This constituted 45% of our overall experience in constructing the Fontan circulation between 1988 and 1996, and 96% of the experience between 1996 and 2005. Among all surviving patients, the median follow-up was 7.3 years. We calculated the expected survival for an optimal candidate, given from the initial equations, and compared this to our entire experience in constructing the Fontan circulation. RESULTS: An internal tube was utilized in 61 patients, 97% of whom were operated prior to 1998, and an external tube in 51 patients, the latter accounting for 95% of all operations since 1999. At 1, 5, 10 and 15 years, survival of the entire cohort receiving polytetraflouroethylene tubes is superimposable on the curve calculated for a "perfect" outcome. Freedom from replacement or revision of the tube was 97% at 10 years. CONCLUSION: Using a standardized operative procedure, combining a bidirectional cavopulmonary connection with a polytetraflouroethylene tube placed from the inferior caval vein to the pulmonary arteries for nearly all patients with functionally univentricular hearts, early and late survival within the "perfect" outcome as predicted by the initial equations of Fontan and Kirklin is routinely achievable in the current era. The need for late revision or replacement of the tube is rare.


Assuntos
Técnica de Fontan , Técnica de Fontan/instrumentação , Técnica de Fontan/métodos , Técnica de Fontan/mortalidade , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/cirurgia , Humanos , Análise Multivariada , Politetrafluoretileno , Reoperação , Resultado do Tratamento
15.
Echocardiography ; 23(5): 421-7, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16686630

RESUMO

In this report, we present 12 patients (range 14-76 years, mean 40 +/- 22.7 years) who underwent surgical repair of a ventricular septal defect (VSD). Location, size, and surrounding anatomy of the VSD were assessed prior to intervention in all patients with live/real time three-dimensional transthoracic echocardiography (3DTTE). In 9 patients, measurements of maximum dimension, circumference, and area by 3DTTE correlated well with the same measurements from intraoperative three-dimensional transesophageal echocardiographic (3DTEE) reconstruction. 3DTTE measurement of maximum dimension of VSDs also agreed well with maximum dimension by surgery in 10 patients. Live/real time 3DTTE accurately defined VSD location, size, and surrounding anatomy in all patients studied by us. VSD characterization by live 3DTTE agreed well with surgery descriptions and 3DTEE measurements.


Assuntos
Sistemas Computacionais , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/patologia , Adolescente , Adulto , Idoso , Ecocardiografia Transesofagiana , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
16.
Echocardiography ; 23(6): 513-8, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16839393

RESUMO

In this report, we present 34 patients in whom surgical intervention was undertaken for severe mitral insufficiency due to mitral valve prolapse (MVP). Location and severity of MVP and regurgitation were assessed preoperatively by live/real time three-dimensional transthoracic echocardiography and closely agreed with the surgical findings.


Assuntos
Ecocardiografia Tridimensional , Prolapso da Valva Mitral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sensibilidade e Especificidade
17.
Echocardiography ; 22(2): 137-43, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15693780

RESUMO

This preliminary study demonstrates the superiority of live three-dimensional transthoracic echocardiography (3D TTE) over two-dimensional (2D) TTE in the assessment of left atrial (LA) tumors in four patients studied by us (three myxomas, one hemangioma, all subsequently pathologically proven). Because of the unique ability of live 3D TTE to systematically section and view the contents of an intracardiac mass, LA myxomas in the three patients studied could be more confidently diagnosed by noting isolated echolucent areas consistent with hemorrhage/necrosis in the tumor mass. On the other hand, a definite echolucent area was found by 2D TTE in only two of the three patients with myxoma. In the fourth patient with a hemangioma, live 3D TTE showed much more extensive and closely packed echolucencies with little solid tissue as compared to a myxoma consistent with a highly vascularized tumor. In contrast, 2D TTE demonstrated only two isolated echolucencies in the tumor suggesting an erroneous diagnosis of myxoma.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia , Neoplasias Cardíacas/diagnóstico por imagem , Feminino , Átrios do Coração , Hemangioma/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Mixoma/diagnóstico por imagem
18.
Echocardiography ; 20(3): 305-7, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12848674

RESUMO

We report three-dimensional transesophageal echocardiographic findings in an adult patient with Ebstein's anomaly. Using the anyplane technique and multiple views, especially the short-axis view of tricuspid valve, three-dimensional transesophageal echocardiography clearly demonstrated the intermittent tethering of all three leaflets of tricuspid valve to the right ventricular walls giving a "bubble-like" appearance. On the other hand, two-dimensional transesophageal echocardiography demonstrated well the tethering of the septal tricuspid leaflet, but tethering of the other two leaflets was not well seen. To our knowledge, these findings have not been demonstrated by three-dimensional transesophageal echocardiography before.


Assuntos
Anomalia de Ebstein/diagnóstico por imagem , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Adulto , Humanos , Masculino
19.
Echocardiography ; 21(2): 199-202, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14961805

RESUMO

Right coronary artery to coronary sinus fistula is a rare anomaly. We present a unique case of an adult patient with multiple fistulae from the right coronary artery draining into the coronary sinus near the posterior left atrium-left ventricle junction, first suspected by transthoracic two-dimensional echocardiography. The multiple openings were not seen by any invasive or noninvasive techniques and were noted only at the time of surgery. To our knowledge, this is the first case of multiple fistulae connecting the right coronary artery to the coronary sinus that has been reported in the English literature.


Assuntos
Anomalias dos Vasos Coronários/diagnóstico , Ecocardiografia/métodos , Fístula/diagnóstico , Adulto , Cateterismo Cardíaco , Angiografia Coronária , Anomalias dos Vasos Coronários/complicações , Anomalias dos Vasos Coronários/cirurgia , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Feminino , Fístula/complicações , Fístula/cirurgia , Comunicação Interatrial/complicações , Comunicação Interatrial/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética
20.
Echocardiography ; 20(1): 105-9, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12848709

RESUMO

We present two- and three-dimensional transesophageal echocardiographic findings of two adult patients who presented for reoperation after previous repair of a partial atrioventricular (AV) septal defect. Both patients had a cleft in the left AV valve with severe regurgitation. One patient had an additional 10 x 5 mm defect connecting the left ventricle to the right atrium through the AV junction. Three-dimensional echocardiography was superior to two-dimensional echocardiography in comprehensively delineating the anatomical defects in the left AV valve and the AV junction.


Assuntos
Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interventricular/diagnóstico por imagem , Adulto , Feminino , Comunicação Interatrial/cirurgia , Comunicação Interventricular/cirurgia , Humanos , Reoperação
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa