Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
País como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | WPRIM | ID: wpr-1044816

RESUMO

Objective@#To evaluate the diagnostic performance and image quality of 1.5-mm slice thickness MRI with deep learningbased image reconstruction (1.5-mm MRI + DLR) compared to routine 3-mm slice thickness MRI (routine MRI) and 1.5-mm slice thickness MRI without DLR (1.5-mm MRI without DLR) for evaluating temporal lobe epilepsy (TLE). @*Materials and Methods@#This retrospective study included 117 MR image sets comprising 1.5-mm MRI + DLR, 1.5-mm MRI without DLR, and routine MRI from 117 consecutive patients (mean age, 41 years; 61 female; 34 patients with TLE and 83 without TLE). Two neuroradiologists evaluated the presence of hippocampal or temporal lobe lesions, volume loss, signal abnormalities, loss of internal structure of the hippocampus, and lesion conspicuity in the temporal lobe. Reference standards for TLE were independently constructed by neurologists using clinical and radiological findings. Subjective image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were analyzed. Performance in diagnosing TLE, lesion findings, and image quality were compared among the three protocols. @*Results@#The pooled sensitivity of 1.5-mm MRI + DLR (91.2%) for diagnosing TLE was higher than that of routine MRI (72.1%, P < 0.001). In the subgroup analysis, 1.5-mm MRI + DLR showed higher sensitivity for hippocampal lesions than routine MRI (92.7% vs. 75.0%, P = 0.001), with improved depiction of hippocampal T2 high signal intensity change (P = 0.016) and loss of internal structure (P < 0.001). However, the pooled specificity of 1.5-mm MRI + DLR (76.5%) was lower than that of routine MRI (89.2%, P = 0.004). Compared with 1.5-mm MRI without DLR, 1.5-mm MRI + DLR resulted in significantly improved pooled accuracy (91.2% vs. 73.1%, P = 0.010), image quality, SNR, and CNR (all, P < 0.001). @*Conclusion@#The use of 1.5-mm MRI + DLR enhanced the performance of MRI in diagnosing TLE, particularly in hippocampal evaluation, because of improved depiction of hippocampal abnormalities and enhanced image quality.

2.
Artigo em Inglês | WPRIM | ID: wpr-1044866

RESUMO

Objective@#Differentiating intracranial aneurysms from normal variants using CT angiography (CTA) or MR angiography (MRA) poses significant challenges. This study aimed to evaluate the efficacy of proton-density MRA (PD-MRA) compared to highresolution time-of-flight MRA (HR-MRA) in diagnosing aneurysms among patients with indeterminate findings on conventional CTA or MRA. @*Materials and Methods@#In this retrospective analysis, we included patients who underwent both PD-MRA and HR-MRA from August 2020 to July 2022 to assess lesions deemed indeterminate on prior conventional CTA or MRA examinations. Three experienced neuroradiologists independently reviewed the lesions using HR-MRA and PD-MRA with reconstructed voxel sizes of 0.253 mm3 or 0.23 mm3 , respectively. A neurointerventionist established the gold standard with digital subtraction angiography.We compared the performance of HR-MRA, PD-MRA (0.253 -mm3 voxel), and PD-MRA (0.23 -mm3 voxel) in diagnosing aneurysms, both per lesion and per patient. The Fleiss kappa statistic was used to calculate inter-reader agreement. @*Results@#The study involved 109 patients (average age 57.4 ± 11.0 years; male:female ratio, 11:98) with 141 indeterminate lesions. Of these, 78 lesions (55.3%) in 69 patients were confirmed as aneurysms by the reference standard. PD-MRA (0.253 -mm3voxel) exhibited significantly higher per-lesion diagnostic performance compared to HR-MRA across all three readers: sensitivity ranged from 87.2%–91.0% versus 66.7%–70.5%; specificity from 93.7%–96.8% versus 58.7%–68.3%; and accuracy from 90.8%–92.9% versus 63.8%–69.5% (P ≤ 0.003). Furthermore, PD-MRA (0.253 -mm3 voxel) demonstrated significantly superior per-patient specificity and accuracy compared to HR-MRA across all evaluators (P ≤ 0.013). The diagnostic accuracy of PD-MRA (0.23 -mm3 voxel) surpassed that of HR-MRA and was comparable to PD-MRA (0.253 -mm3 voxel). The kappa values for inter-reader agreements were significantly higher in PD-MRA (0.820–0.938) than in HR-MRA (0.447–0.510). @*Conclusion@#PD-MRA outperformed HR-MRA in diagnostic accuracy and demonstrated almost perfect inter-reader consistency in identifying intracranial aneurysms among patients with lesions initially indeterminate on CTA or MRA.

3.
Artigo em Inglês | WPRIM | ID: wpr-916686

RESUMO

Localized forms of gallbladder adenomyomatosis are rarely polypoid and may mimic gallbladder cancer. Herein, we present a unique case of polypoid gallbladder adenomyomatosis penetrating the colon and preoperatively misdiagnosed as advanced hepatic flexure colon cancer.

4.
Artigo em Inglês | WPRIM | ID: wpr-916709

RESUMO

PURPOSE@#To assess the venographic findings of central venous abnormalities before exchanging dysfunctional tunneled hemodialysis catheters and the outcome of endovascular salvage techniques.@*MATERIALS AND METHODS@#A total of 110 episodes of tunneled hemodialysis catheter dysfunction in 78 patients undergoing catheter-directed hemodialysis treatment from January 2011 to December 2015 were retrospectively evaluated. Venography was performed before catheter exchange, and the following procedures were conducted according to the venographic findings: balloon disruption of a fibrin sheath, angioplasty for central vein stenosis, or stent insertion. Technical success was defined as at least one successful session of hemodialysis with the exchanged catheter. Patients were followed until the study endpoints or the last hospital visit.@*RESULTS@#Venography showed abnormalities in patients with 67 of the 110 exchanged catheters, including central vein stenosis (n = 27), fibrin sheath formation (n = 17), and thrombus formation (n = 12). Technical success was confirmed in all cases. The estimated 30-day catheter patency for all assessable catheters was 61.7%. Nine catheters were removed during the follow-up period because of suspected catheter-related infections.@*CONCLUSION@#In approximately 60% of cases of dysfunctional tunneled hemodialysis catheter, abnormal venographic findings were observed in the patients. Following appropriate endovascular techniques could be helpful in improving catheter patency with a low risk of procedure-related complications.

5.
Artigo em Inglês | WPRIM | ID: wpr-211243

RESUMO

OBJECTIVES: Decreased fertility and impaired health owing to early menopause are significant health issues. Smoking is a modifiable health-related behavior that influences menopausal age. We investigated the effects of smoking-associated characteristics on menopausal age in Korean women. METHODS: This study used data from the Korea National Health and Nutrition Examination Survey from 2007 to 2012. Menopausal age in relation to smoking was analyzed as a Kaplan-Meier survival curve for 11 510 women (aged 30 to 65 years). The risk of entering menopause and experiencing early menopause (before age 48) related to smoking were assessed using a Cox proportional hazards model. RESULTS: The menopausal age among smokers was 0.75 years lower than that among non-smokers (p<0.001). The results of the Cox proportional hazards model showed pre-correction and post-correction risk ratios for entering menopause related to smoking of 1.26 (95% confidence interval [CI], 1.09 to 1.46) and 1.27 (95% CI, 1.10 to 1.47), respectively, and pre-correction and post-correction risk ratios for experiencing early menopause related to smoking of 1.36 (95% CI, 1.03 to 1.80) and 1.40 (95% CI, 1.05 to 1.85), respectively. CONCLUSIONS: Smokers reached menopause earlier than non-smokers, and their risk for experiencing early menopause was higher.


Assuntos
Adulto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Fatores Etários , Estudos Transversais , Demografia , Menopausa , Inquéritos Nutricionais , Modelos de Riscos Proporcionais , República da Coreia , Fatores de Risco , Fumar
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa