Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Catheter Cardiovasc Interv ; 95(3): 411-413, 2020 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31456357

RESUMO

Patients presenting with cardiogenic shock and severe combined aortic and mitral regurgitation represent a major clinical challenge. Therapeutic options are limited in this setting as they are often deemed inoperable due to prohibitive risk for surgery, while mechanical circulatory support is usually contraindicated or technically challenging. Medical therapy, on the other hand, is associated with high-mortality rates. Therefore, percutaneous therapies may represent an appealing alternative. Here, we present a "one-stop-shop" totally percutaneous approach for severe aortic and mitral regurgitation in a patient with cardiogenic shock.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Choque Cardiogênico/fisiopatologia , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Choque Cardiogênico/diagnóstico , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Função Ventricular Esquerda
2.
J Interv Cardiol ; 31(6): 932-938, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30051923

RESUMO

AIMS: Left atrial appendage (LAA) closure is considered an effective option in patients with non-valvular atrial fibrillation (NVAF) and contraindications to long-term oral anticoagulant (OAC) therapy. However, there are some concerns about safety of currently available devices. Our aim is to provide an initial assessment on feasibility and safety of the novel LAA closure Ultraseal device in patients with NVAF and contraindications to long-term OAC therapy. METHODS: Twenty-three consecutive patients with NVAF undergoing Ultraseal device implantation between July 2016 and February 2018 at two institutions were included. All patients performed transesophageal echocardiography and computed tomography angiography prior to LAA closure. RESULTS: Procedural success was achieved in all patients except two who experienced incorrect device deployment with incomplete LAA closure. Procedure duration halved from first to last procedure performed. The only periprocedural adverse events observed were a myocardial infarction and an in-hospital death due pneumonia. At mean follow-up (166 ± 80 days) all other patients were alive and free from major bleedings and ischaemic strokes. CONCLUSIONS: Our results suggest that the Ultraseal device is a feasible option for LAA occlusion. Notably, the learning curve in this registry was fast, paralleled by extremely low complication rates. These results should be considered hypothesis generating and larger studies are mandatory.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/instrumentação , Idoso , Apêndice Atrial/diagnóstico por imagem , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Angiografia por Tomografia Computadorizada/métodos , Ecocardiografia Transesofagiana/métodos , Desenho de Equipamento/efeitos adversos , Desenho de Equipamento/métodos , Falha de Equipamento/estatística & dados numéricos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Sistema de Registros , Resultado do Tratamento
3.
ESC Heart Fail ; 9(5): 3177-3187, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35770326

RESUMO

AIM: Randomized controlled trials comparing the use of the MitraClip device in addition to guideline directed medical therapy (GDMT) to GDMT alone in patients with secondary mitral regurgitation (MR) have shown conflicting results. However, if these differences could be due to the underlying MR aetiology is still unknown. Therefore, we aimed to evaluate if the effects of percutaneous edge-to-edge repair with MitraClip implantation could differ in patients with ischaemic (I-MR) and non-ischaemic mitral regurgitation (NI-MR). METHODS AND RESULTS: PubMed, Embase, BioMed Central, and the Cochrane Central Register of Controlled Trials were searched for all studies including patients with secondary MR treated with the MitraClip device. Data were pooled using a random-effects model. Primary endpoint was the composite of all-cause death and heart failure-related hospitalization. Secondary endpoints were the single components of the primary endpoint, New York Heart Association functional Classes III and IV, and mitral valve re-intervention. Seven studies enrolling 2501 patients were included. Patients with I-MR compared with patients with NI-MR had a similar risk of the primary endpoint (odds ratio: 1.17; 95% confidence interval: 0.93 to 1.46; I2 : 0%). The risk of all-cause death was increased in patients with I-MR (odds ratio: 1.31; 95% confidence interval: 1.07 to 1.62; I2 : 0%), while no differences were observed between the two groups in terms of the other secondary endpoints. CONCLUSIONS: The risk of mortality after MitraClip implantation is lower in patients with NI-MR than in those with I-MR. No absolute differences in the risk of heart failure related hospitalization were observed between groups.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento , Valva Mitral/cirurgia
4.
Heart ; 106(19): 1512-1518, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32817312

RESUMO

OBJECTIVE: Risk stratification is crucial to optimise treatment strategies in patients with COVID-19. We aimed to evaluate the impact on mortality of an early assessment of cardiac biomarkers in patients with COVID-19. METHODS: Humanitas Clinical and Research Hospital (Rozzano-Milan, Lombardy, Italy) is a tertiary centre that has been converted to the management of COVID-19. Patients with confirmed COVID-19 were entered in a dedicated database for cohort observational analyses. Outcomes were stratified according to elevated levels (ie, above the upper level of normal) of high-sensitivity cardiac troponin I (hs-TnI), B-type natriuretic peptide (BNP) or both measured within 24 hours after hospital admission. The primary outcome was all-cause mortality. RESULTS: A total of 397 consecutive patients with COVID-19 were included up to 1 April 2020. At the time of hospital admission, 208 patients (52.4%) had normal values for cardiac biomarkers, 90 (22.7%) had elevated both hs-TnI and BNP, 59 (14.9%) had elevated only BNP and 40 (10.1%) had elevated only hs-TnI. The rate of mortality was higher in patients with elevated hs-TnI (22.5%, OR 4.35, 95% CI 1.72 to 11.04), BNP (33.9%, OR 7.37, 95% CI 3.53 to 16.75) or both (55.6%, OR 18.75, 95% CI 9.32 to 37.71) as compared with those without elevated cardiac biomarkers (6.25%). A multivariate analysis identified concomitant elevation of both hs-TnI and BNP as a strong independent predictor of all-cause mortality (OR 3.24, 95% CI 1.06 to 9.93). CONCLUSIONS: An early detection of elevated hs-TnI and BNP predicts mortality in patients with COVID-19. Cardiac biomarkers should be systematically assessed in patients with COVID-19 at the time of hospital admission in order to optimise risk stratification.


Assuntos
Betacoronavirus , Doenças Cardiovasculares/epidemiologia , Infecções por Coronavirus/sangue , Infecções por Coronavirus/mortalidade , Peptídeo Natriurético Encefálico/sangue , Pneumonia Viral/sangue , Pneumonia Viral/mortalidade , Troponina I/sangue , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , COVID-19 , Infecções por Coronavirus/complicações , Diagnóstico Precoce , Feminino , Hospitalização , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/complicações , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , SARS-CoV-2
5.
JACC Cardiovasc Interv ; 13(2): 196-206, 2020 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-31883714

RESUMO

OBJECTIVES: The aim of this study was to evaluate and compare the outcomes of transcatheter self-expandable prostheses in patients with small annuli. BACKGROUND: Transcatheter aortic heart valves appear to have better performance than surgical valves in terms of prosthesis-patient mismatch, especially in patients with aortic stenosis with small aortic annuli. METHODS: TAVI-SMALL (International Multicenter Registry to Evaluate the Performance of Self-Expandable Valves in Small Aortic Annuli) is a retrospective registry of patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 on computed tomography) treated with transcatheter self-expandable valves (n = 859; Evolut R, n = 397; Evolut PRO, n = 84; ACURATE, n = 201; Portico, n = 177). Primary endpoints were post-procedural mean aortic gradient, indexed effective orifice area, and rate of severe prosthesis-patient mismatch. RESULTS: Pre-discharge gradients were consistently low in every group, with a slight benefit with the Evolut R (8.1 mm Hg; 95% confidence interval [CI]: 7.7 to 8.5 mm Hg) and Evolut PRO (6.9 mm Hg; 95% CI: 6.3 to 7.6 mm Hg) compared with the ACURATE (9.6 mm Hg; 95% CI: 8.9 to 10.2 mm Hg) and Portico (8.9 mm Hg; 95% CI: 8.2 to 9.6 mm Hg) groups (p < 0.001). Mean indexed effective orifice area was 1.04 cm2/m2 (95% CI: 1.01 to 1.08 cm2/m2) with a trend toward lower values with the Portico. No significant differences were reported in terms of severe prosthesis-patient mismatch (overall rate 9.4%; p = 0.134), permanent pacemaker implantation (15.6%), and periprocedural and 1-year adverse events. Pre-discharge more than mild paravalvular leaks were significantly more common with the Portico (19.2%) and less common with the Evolut PRO (3.6%) compared with the Evolut R (11.8%) and ACURATE (9%) groups. CONCLUSIONS: Transcatheter self-expandable valves showed optimal clinical and echocardiographic results in patients with small aortic annuli, although supra-annular functioning transcatheter heart valves seemed to slightly outperform intra-annular functioning ones. The role of transcatheter aortic valve replacement with self-expandable valves for the treatment of aortic stenosis in patients with small annuli needs to be confirmed in larger trials.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Europa (Continente) , Feminino , Hemodinâmica , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
G Ital Cardiol (Rome) ; 19(3): 191-193, 2018 Mar.
Artigo em Italiano | MEDLINE | ID: mdl-29873647

RESUMO

Coronary artery disease and aortic stenosis frequently coexist. The pathophysiology of both conditions is similar where atherosclerosis is the hallmark feature. Risk factors for aortic stenosis are also similar for coronary artery disease. The standard therapy in the past decades has been coronary artery bypass grafting and aortic valve replacement; however, with the introduction of transcatheter aortic valve implantation their management is probably going to shift towards a percutaneous strategy.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/cirurgia , Idoso , Estenose da Valva Aórtica/complicações , Doença da Artéria Coronariana/complicações , Humanos , Masculino , Índice de Gravidade de Doença , Procedimentos Cirúrgicos Vasculares/métodos , Disfunção Ventricular Esquerda/complicações
7.
JACC Cardiovasc Interv ; 11(19): 1932-1941, 2018 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-30249439

RESUMO

OBJECTIVES: This study sought to evaluate the feasibility, safety, and efficacy of the Ultraseal device for left atrial appendage closure (LAAC) (Cardia, Eagan, Minnesota) in patients with nonvalvular atrial fibrillation at high bleeding risk. BACKGROUND: The Ultraseal device is a novel bulb-and-sail designed LAAC device, with an articulating joint enabling conformability to heterogeneous angles and shapes of appendage anatomy. METHODS: This was a multicenter study including consecutive patients undergoing LAAC with the Ultraseal device at 15 Canadian and European sites. Periprocedural and follow-up events were systematically collected, and transesophageal echocardiography at 45 to 180 days post-procedure was routinely performed in all centers but 3. RESULTS: A total of 126 patients (mean age 75 ± 8 years; mean CHA2DS2-VASc score 5 ± 2; mean HAS-BLED score 4 ± 1) were included. The device was successfully implanted in 97% of patients. A major periprocedural adverse event occurred in 3 (2.4%) patients (clinically relevant pericardial effusion [n = 1], stroke [n = 1], device embolization [n = 1]). Ninety percent of patients were discharged on single or dual antiplatelet therapy. Follow-up transesophageal echocardiography was available in 89 (73%) patients, with no cases of large (>5 mm) residual leak and 5 (5.6%) cases of device-related thrombosis (all successfully treated with anticoagulation therapy). At a median follow-up of 6 (interquartile range: 3 to 10) months, the rates of stroke and transient ischemic attack were 0.8% and 0.8%, respectively, with no systemic emboli. None of the events occurred in patients with device-related thrombosis. CONCLUSIONS: In this initial multicenter experience, LAAC with the Ultraseal device was associated with a high implant success rate and a very low incidence of periprocedural complications. There were no late device-related clinical events and promising efficacy results were observed regarding thromboembolic prevention at midterm follow-up. Larger studies are further warranted to confirm the long-term safety and efficacy of this novel device.


Assuntos
Apêndice Atrial , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Canadá , Cateterismo Cardíaco/efeitos adversos , Desenho de Equipamento , Europa (Continente) , Estudos de Viabilidade , Feminino , Humanos , Masculino , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
EuroIntervention ; 12(16): 1978-1986, 2017 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-27993752

RESUMO

AIMS: The aim of this study was to evaluate the safety and efficacy profile of new-generation, SYNERGY everolimus-eluting stents (S-EES) as compared to XIENCE everolimus-eluting stents (X-EES) with a durable polymer coating in "complex patients". METHODS AND RESULTS: We included 2,001 consecutive patients treated with S-EES (n=400) or X-EES (n=1,601) at two Italian centres between May 2013 and May 2015. We used propensity score matching to obtain two cohorts of patients with similar baseline risk profiles. Patients were stratified according to baseline complexity based on the EVOLVE II trial exclusion criteria. The primary outcome was major adverse cardiac events (MACE), defined as the composite of all-cause death, myocardial infarction (MI), and target lesion revascularisation (TLR), at one year. Among 391 matched pairs of patients treated with S-EES or X-EES, we identified 253 (63%) as complex. At one-year follow-up, among "complex" patients, MACE rates did not differ between the S-EES and X-EES groups (9.9% vs. 9.5%, p=0.830, HR 1.04, CI: 0.72-1.48). Similarly, death, MI, and TLR, stratified for complexity, were comparable between S-EES and X-EES treated patients at one year. Of note, no definite ST was observed in either the S-EES or the X-EES cohort. CONCLUSIONS: New-generation S-EES with a bioresorbable polymer coating appear to be safe and effective irrespective of patient complexity as compared to X-EES.


Assuntos
Implantes Absorvíveis , Stents Farmacológicos , Everolimo/uso terapêutico , Infarto do Miocárdio/terapia , Implantes Absorvíveis/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Stents Farmacológicos/efeitos adversos , Everolimo/administração & dosagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Polímeros , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento
9.
Ann Biomed Eng ; 44(2): 488-96, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26265457

RESUMO

Percutaneous coronary interventions (PCI) were proposed in the late 1970s as an alternative to surgical coronary artery bypass grafting for the treatment of coronary artery disease. Important technological progress has been made since. Balloon angioplasty was replaced by bare metal stents, which allowed to permanently scaffold the coronary vessel avoiding acute recoil and abrupt occlusion. Thereafter, the introduction of early generation drug-eluting stents (DES) has significantly improved clinical outcomes, primarily by markedly reducing the risk of restenosis. New generation DES with thinner stent struts, novel durable or biodegradable polymer coatings, and new limus antiproliferative agents, have further improved upon the safety and efficacy profile of early generation DES. The present article aims to review the impact of technological advances on clinical outcomes in the field of PCI with coronary stents, and to provide a brief overview on clinical margins of improvement and unmet needs of available DES.


Assuntos
Vasos Coronários , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/tendências , Stents/tendências , Vasos Coronários/fisiopatologia , Vasos Coronários/cirurgia , Oclusão de Enxerto Vascular/fisiopatologia , Oclusão de Enxerto Vascular/prevenção & controle , Humanos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa