Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Physiol Plant ; 152(4): 729-37, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24735095

RESUMO

In wheat, nutrients are transported to seeds via the phloem yet access to this vascular tissue for exudate collection and quantitative analysis of elemental composition is difficult. The purest phloem is collected through the use of aphid stylectomy with volumes of exudate collected normally in the range of 20-500 nl. In this work a new method using inductively coupled plasma mass spectroscopy (ICP-MS) was developed to measure the concentration of K, Mg, Zn and Fe in volumes of wheat (Triticum aestivum, genotype Samnyt 16) phloem as small as 15.5 nl. This improved method was used to observe changes in phloem nutrient concentration during the grain loading period. There were statistically significant increases in phloem Mg and Zn concentration and a significant decrease in K over the period from 1-2 days after anthesis (DAA) to 9-12 DAA. During this period, there was no statistically significant change in phloem Fe concentration.


Assuntos
Floema/metabolismo , Triticum/metabolismo , Animais , Afídeos/fisiologia , Transporte Biológico , Grão Comestível , Ferro/análise , Ferro/metabolismo , Magnésio/análise , Magnésio/metabolismo , Floema/genética , Potássio/análise , Potássio/metabolismo , Sementes/genética , Sementes/metabolismo , Triticum/genética , Zinco/análise , Zinco/metabolismo
2.
Biol Trace Elem Res ; 103(2): 155-68, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15772439

RESUMO

Selenium (Se) is an essential micronutrient for animals and humans, and wheat is a major dietary source of this element. It is important that postharvest processing losses of grain Se are minimized. This study, using grain dissection, milling with a Quadrumat mill, and baking and toasting studies, investigated the distribution of Se and other mineral nutrients in wheat grain and the effect of postharvest processing on their retention. The dissection study, although showing Se concentration to be highest in the embryo, confirmed (along with the milling study) previous findings that Se (which occurs mostly as selenomethionine in wheat grain) and S are more evenly distributed throughout the grain when compared to other mineral nutrients, and, hence, lower proportions are removed in the milling residue. Postmilling processing did not affect Se concentration or content of wheat products in this study. No genotypic variability was observed for grain distribution of Se in the dissection and milling studies, in contrast to Cu, Fe, Mn, and Zn. This variability could be exploited in breeding for higher proportions of these nutrients in the endosperm to make white flour more nutritious. Further research could include grain dissection and milling studies using larger numbers of cultivars that have been grown together and a flour extraction rate of around 70%.


Assuntos
Manipulação de Alimentos , Selênio/análise , Triticum/química , Animais , Culinária , Produtos Agrícolas , Farinha , Humanos , Minerais/análise , Triticum/anatomia & histologia
3.
Plant Methods ; 9: 18, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23773489

RESUMO

BACKGROUND: When conducting aphid stylectomy, measuring accurate rates of phloem exudation is difficult because the volumes collected are in the nanolitre (nl) range. In a new method, exudate volume was calculated from optical measurement of droplet diameter as it forms on the tip of a severed aphid stylet. Evaporation was shown to decrease the accuracy of the measurement but was countered with the addition of water-saturated mineral oil. Volume measurements by optical estimation of the volume of a sphere suspended in oil was affected by the curvature of the oil surface. In contrast, measuring the exudate volume from optical measurement of droplet-diameter as formed on the tip of a severed aphid stylet, removes any inaccuracies due to oil surface curvature. A modified technique is proposed for measuring exudate volumes without oil by estimating the flow rate from photo-sequences of the collection period; a correction for evaporation is applied later. RESULTS: A change in oil volume of ±1.75% from an optimum volume of 285 µl had a statistically significant effect on droplet measurement, under or over-estimating droplet volume due to optical effects caused by the oil surface. Using microscope image capture and measurement software, a modified method for measuring phloem volume in air was developed, by reducing air exposure during measurement to approximately 5 s for each measurement. Phloem volumes were measured using both techniques with measurements in air being on average 19.9 nl less (SD 18.87, p<0.001) than those made in oil, and there was a strong linear relationship (R(2)=0.942) between the techniques. This linear relationship enabled the development of a correction equation with no significant difference at the 5% level between corrected volumes and actual volumes measured under oil. CONCLUSIONS: This study showed that oil has a significant role in countering evaporation but oil volume must be carefully optimised for optical measurement of droplets to ensure measurement accuracy. A linear correction factor was generated to correct the volumes measured in air for loss due to evaporation and the method provides for a much simpler alternative to previous approaches for measuring exudation rates and volumes from a cut aphid stylet.

4.
Med J Aust ; 180(8): 383-6, 2004 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-15089727

RESUMO

OBJECTIVE: To assess trends in selenium status in South Australians from 1977 to 2002. DESIGN: Six cross-sectional surveys. PARTICIPANTS: 117 participants in 1977, 30 in 1979, 96 and 103 (separate surveys) in 1987, 200 in 1988, and 288 volunteer blood donors in 2002. A total of 834 healthy Australian adults (mean age, 42 years [range, 17-71 years]; 445 were male). MAIN OUTCOME MEASURES: Plasma and whole blood selenium concentrations. RESULTS: The 2002 survey yielded a mean plasma selenium concentration of 103 micro g/L (SE, 0.65), which reached the estimated nutritional adequacy level of 100 micro g/L plasma selenium. Mean whole blood selenium declined 20% from the 1977 and 1979 surveys (mean whole blood selenium concentration, 153 micro g/L) to the 1987, 1988 and 2002 surveys (mean whole blood selenium concentration, 122 micro g/L). Plasma selenium was higher in men (P = 0.01), and increased with age in both men and women (P = 0.008). CONCLUSIONS: In healthy South Australian adults sampled from 1977 to 2002, whole blood and plasma selenium concentrations were above those reported for most other countries and in most previous Australian studies, notwithstanding an apparent decline in selenium status from the late 1970s to the late 1980s.


Assuntos
Selênio/sangue , Adolescente , Adulto , Idoso , Austrália/epidemiologia , Estudos Transversais , Deficiências Nutricionais/epidemiologia , Feminino , Previsões , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Selênio/deficiência
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa