Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(7): 1452-1460, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38757909

RESUMO

INTRODUCTION: Left bundle branch area (LBBA) pacing (LBBAP) has been proposed as an alternative therapy option in patients indicated for cardiac pacing to treat bradycardia or heart failure. The aim of the study was to evaluate the safety and effectiveness of LBBAP in patients implanted with a Tendril 2088 stylet-driven lead. METHODS: The international retrospective data collection registry included 11 sites from 5 countries globally. Patients with attempted implants of the Tendril lead in the LBBA were followed for at least 6 months post the implant attempt. The primary safety and efficacy endpoints were freedom from LBBAP lead-related serious adverse events and the composite of LBBA capture threshold of ≤2.0 V and R-wave amplitudes ≥5 mV (or ≥value at implant), respectively. RESULTS: Of 221 patients with attempted implants of the Tendril 2088 lead in the LBBA, 91.4% (202/221) had successful implants for LBBAP. Regardless of the LBBAP implant success, all patients were followed for at least 6 months (8.7 ± 7.3 months). Baseline characteristics: 44% female, 84% ≥65 years old, 34% coronary artery disease, and 86% of primary indications for pacemaker implant. Both primary safety and effectiveness endpoints were met (freedom from LBBAP lead-related serious adverse device effects of 99.5% and electrical performance composite success rate of 93%). The capture thresholds in LBBAP at implant and 6 months were 0.8 ± 0.3 V@0.4 ± 0.1 ms and 0.8 ± 0.3 V@0.4 ± 0.1 ms. The rate of patients with capture threshold rise ≥1 V was 1.5% through 6 months. The R-wave amplitudes in LBBAP at implant and 6 months were 9.3 ± 3.2 mV and 10.6 ± 3.0 mV. CONCLUSIONS: This large multicenter study demonstrates that the stylet-driven Tendril™ STS 2088 lead is safe and effective for LBBAP with high success and low complication rates.


Assuntos
Potenciais de Ação , Estimulação Cardíaca Artificial , Frequência Cardíaca , Marca-Passo Artificial , Sistema de Registros , Humanos , Feminino , Masculino , Idoso , Estudos Retrospectivos , Fatores de Tempo , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso de 80 Anos ou mais , Bradicardia/fisiopatologia , Bradicardia/terapia , Bradicardia/diagnóstico , Fascículo Atrioventricular/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Fatores de Risco , Desenho de Equipamento
2.
Europace ; 26(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38703372

RESUMO

AIMS: To characterize the diagnosis, frequency, and procedural implications of septal venous channel perforation during left bundle branch area pacing (LBBAP). METHODS AND RESULTS: All consecutive patients undergoing LBBAP over an 8-month period were prospectively studied. During lead placement, obligatory septal contrast injection was performed twice, at initiation (implant entry zone) and at completion (fixation zone). An intuitive fluoroscopic schema using orthogonal views (left anterior oblique/right anterior oblique) and familiar landmarks is described. Using this, we resolved zonal distribution (I-VI) of lead position on the ventricular septum and its angulation (post-fixation angle θ). Subjects with and without septal venous channel perforation were compared. Sixty-one patients {male 57.3%, median age [interquartile range (IQR)] 69.5 [62.5-74.5] years} were enrolled. Septal venous channel perforation was observed in eight (13.1%) patients [male 28.5%, median age (IQR) 64 (50-75) years]. They had higher frequency of (i) right-sided implant (25% vs. 1.9%, P = 0.04), (ii) fixation in zone III at the mid-superior septum (75% vs. 28.3%, P = 0.04), (iii) steeper angle of fixation-median θ (IQR) [19 (10-30)° vs. 5 (4-19)°, P = 0.01], and (iv) longer median penetrated-lead length (IQR) [13 (10-14.8) vs. 10 (8.5-12.5) mm, P = 0.03]. Coronary sinus drainage of contrast was noted in five (62.5%) patients. Abnormal impedance drops during implantation (12.5% vs. 5.7%, P = NS) were not significantly different. CONCLUSION: When evaluated systematically, septal venous channel perforation may be encountered commonly after LBBAP. The fiducial reference framework described using fluoroscopic imaging identified salient associated findings. This may be addressed with lead repositioning to a more inferior location and is not associated with adverse consequence acutely or in early follow-up.


Assuntos
Estimulação Cardíaca Artificial , Humanos , Masculino , Feminino , Estudos Prospectivos , Pessoa de Meia-Idade , Idoso , Estimulação Cardíaca Artificial/métodos , Septo Interventricular/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/diagnóstico por imagem , Resultado do Tratamento , Fatores de Risco , Fascículo Atrioventricular/fisiopatologia , Septos Cardíacos/diagnóstico por imagem , Meios de Contraste , Fluoroscopia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/etiologia
3.
Indian Pacing Electrophysiol J ; 24(2): 105-110, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38176468

RESUMO

Accessory pathway ablation in Ebstein anomaly can be significantly more challenging than in structurally normal hearts. An alternative to the conventional approach to mapping APs is to detect points with a high-density mapping catheter based on an automated detection algorithm using open window mapping. It detects the sharpest signal at each point with high-density mapping rather than relying on the origin of the local electrogram to localize the pathway and determine a site for successful ablation. We herein report the first case in literature of a redo-accessory pathway ablation in Ebstein anomaly using this technique.

4.
J Cardiovasc Electrophysiol ; 31(3): 612-620, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31916658

RESUMO

INTRODUCTION: Catheter ablation (CA) of ventricular tachycardia (VT) in cardiac sarcoidosis (CS) has been reported with varying success. However, there is a scarcity of data on the outcomes of CA based on ongoing inflammation. OBJECTIVE: We hypothesized that the response to VT ablation depends upon the stage of the disease. METHODS: Between July 2004 and December 2018, 24 patients of CS presented with drug-refractory VT at CARE Hospital (Hyderabad) and the University of Minnesota (Minneapolis, MN). Patients were classified into two groups based on cardiac magnetic resonance imaging and positron emission tomography: (a) inflammatory phase, (b) scar phase. All patients underwent 3D electro-anatomic mapping guided CA. RESULTS: The clinical VT was ablated in all but one patient. In 16 patients (66.6%), both the clinical and nonclinical VTs were ablated (complete success), while in seven patients (29.1%) nonclinical VTs was still inducible. In patients with inflammation (group A), complete success for VT ablation was achieved in 10 out of 17 (58.8%). In patients without inflammation (group B), complete success was achieved in six out of seven patients (85.7%). Eleven patients (45.8%) had a recurrence of VT. Among patients in the inflammatory phase (group A): 10 out of 17 patients had a recurrence of VT, while only one out of seven patients in the scar phase (group B) had VT recurrence over a mean follow-up of 5.7 ± 3.9 years. Epicardial ablation was performed in 10 (41.6%) patients. CONCLUSION: CA of drug-refractory VT in CS is effective, often requiring the epicardial approach. Incomplete success and recurrence of VT were higher in the inflammatory phase of the disease.


Assuntos
Cardiomiopatias/complicações , Ablação por Cateter , Miocardite/etiologia , Sarcoidose/complicações , Taquicardia Ventricular/cirurgia , Adulto , Cardiomiopatias/diagnóstico por imagem , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Índia , Masculino , Pessoa de Meia-Idade , Minnesota , Miocardite/diagnóstico por imagem , Recidiva , Estudos Retrospectivos , Fatores de Risco , Sarcoidose/diagnóstico por imagem , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
10.
Indian Pacing Electrophysiol J ; 18(5): 176-179, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29981366

RESUMO

We present a rare case of tachycardiomyopathy in a 4-year-old girl. The child had incessant atrial tachycardia (AT) and refractory heart failure. Right atrial appendage (RAA) was localised as the source of the ectopic tachycardia. The child underwent successful radiofrequency ablation (RFA) using 3-D electroanatomical mapping. Fluoroscopy was used sparingly only to rule out underlying anomalies. The left ventricular functions returned to normal by one month after the procedure. RAA AT is rare in very young children and usually necessitates surgical appendectomies. RFA is a challenge in such age groups and there are very few published literature on RAA AT in very young children.

17.
J Arrhythm ; 40(1): 156-159, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38333381

RESUMO

Isolated sinus node dysfunction with its pursuant long-term risk for atrioventricular (AV) conduction disease poses a unique dilemma for proponents of CSP due to paucity of imprimatur guidelines. In such scenarios, the risk and prognosis of iatrogenic AV block is not well elucidated but is a valid concern. We report a case where CSP was complicated by iatrogenic AV block and peculiarly the rare phenomenon of intra-Hisian Wenckebach.

18.
J Arrhythm ; 40(1): 160-165, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38333384

RESUMO

Scar-related ventricular tachycardia (VT) ablation involves localizing the critical isthmuses by overdrive pacing maneuvers and three-dimensional activation mapping. Implantable prosthetic devices have been known to complicate this by covering sites of potential isthmuses. We herein present a sentinel report of scar-VT ablation with a protected isthmus localized over an endothelialized post-myocardial infarction ventricular septal defect occluder device.

19.
Heart Rhythm ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38750913

RESUMO

BACKGROUND: Infranodal Wenckebach is rare and not well characterized. OBJECTIVE: We prospectively studied clinical and electrophysiologic characteristics of patients with atrioventricular (AV) Wenckebach with an indication for permanent ventricular pacing. METHODS: During a 2-year period, all patients with an indication for permanent ventricular pacing underwent targeted preimplantation electrophysiologic study. Clinical and electrophysiologic characteristics at presentation and ventricular pacing percentage at 6-month follow-up were evaluated. RESULTS: A total of 163 patients (median age, 68 [interquartile range, 60-74] years; male, 59%; median QRS duration, 110 [90-130] ms; complete AV block in 123 [75.5%]) were included. AV Wenckebach was noted in 22 (13.4%) patients (median age, 70 [63-76.5] years; male, 54%; median QRS duration, 120 [110-140] ms) and classified as infranodal (12/163 [7.3%]) vs AV nodal (10/163 [6.1%]). Patients with infranodal Wenckebach (infrahisian in all), compared with AV nodal Wenckebach, demonstrated higher frequency with left ventricular ejection fraction ≤40% (41.7% vs 0%; P = .04), longer median HV interval (90 vs 49 ms; P = .005), lower frequency of isolated first-degree AV block (8.3% vs 60%; P = .02), higher frequency of right bundle branch block with left anterior fascicular block (75% vs 10%; P = .003), lesser PR increment at onset of AV Wenckebach (20.5 vs 80 ms; P = .002), and onset of 2:1 AV block at longer cycle lengths (91.7% vs 20%; P = .002). CONCLUSION: Of patients referred for pacemaker implantation, infranodal Wenckebach was present in 27.5% (11/40) without complete AV block. It was as frequent as AV nodal Wenckebach and associated with characteristic electrophysiologic findings.

20.
J Interv Card Electrophysiol ; 67(1): 129-137, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37273034

RESUMO

BACKGROUND OR PURPOSE: The prognosis of m ixed cardiomyopathy (CMP) in patients with implanted cardioverter-defibrillators (ICDs) has not been investigated. We aim to study the demographic, clinical, device therapies and survival characteristics of mixed CMP in a cohort of patients implanted with a defibrillator. METHODS: The term mixed CMP was used to categorise patients with impaired left ventricular ejection fraction attributed to documented non-ischemic triggers with concomitant moderate coronary artery disease. This is a single center observational cohort of 526 patients with a mean follow-up of 8.7 ± 3.5 years. RESULTS: There were 42.5% patients with ischemic cardiomyopathy (ICM), 26.9% with non-ischemic cardiomyopathy (NICM) and 30.6% with mixed CMP. Mixed CMP, compared to NICM, was associated with higher mean age (69.1 ± 9.6 years), atrial fibrillation (55.3%) and greater incidence of comorbidities. The proportion of patients with mixed CMP receiving device shocks was 23.6%, compared to 18.4% in NICM and 27% in ICM. The VT cycle length recorded in mixed CMP (281.6 ± 43.1 ms) was comparable with ICM (282.5 ± 44 ms; p = 0.9) and lesser than NICM (297.7 ± 48.7 ms; p = 0.1). All-cause mortality in mixed CMP (21.1%) was similar to ICM (20.1%; p = 0.8) and higher than NICM (15.6%; p = 0.2). The Kaplan-Meier curves revealed hazards of 1.57 (95% CI: 0.91, 2.68) for mixed CMP compared to NICM. CONCLUSION: In a cohort of patients with ICD, the group with mixed CMP represents a phenotype predominantly comprised of the elderly with a higher incidence of comorbidities. Mixed CMP resembles ICM in terms of number of device shocks and VT cycle length. Trends of long-term prognosis of patients with mixed CMP are worse than NICM and similar to ICM.


Assuntos
Cardiomiopatias , Desfibriladores Implantáveis , Isquemia Miocárdica , Humanos , Idoso , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda , Isquemia Miocárdica/complicações , Fenótipo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa