1.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36932709

RESUMO

AIMS: In subcutaneous implantable cardioverter defibrillator (S-ICD) recipients, the UNTOUCHED study demonstrated a very low inappropriate shock rate on programming a conditional zone between 200 and 250 bpm and a shock zone for arrhythmias >250 bpm. The extent to which this programming approach is adopted in clinical practice is still unknown, as is its impact on the rates of inappropriate and appropriate therapies. METHODS AND RESULTS: We assessed ICD programming on implantation and during follow-up in a cohort of 1468 consecutive S-ICD recipients in 56 Italian centres. We also measured the occurrence of inappropriate and appropriate shocks during follow-up. On implantation, the median programmed conditional zone cut-off was set to 200 bpm (IQR: 200-220) and the shock zone cut-off was 230 bpm (IQR: 210-250). During follow-up, the conditional zone cut-off rate was not significantly changed, while the shock zone cut-off was changed in 622 (42%) patients and the median value increased to 250 bpm (IQR: 230-250) (P < 0.001). UNTOUCHED-like programming of detection cut-offs was adopted in 426 (29%) patients immediately after device implantation, and in 714 (49%, P < 0.001) at the last follow-up. UNTOUCHED-like programming was independently associated with fewer inappropriate shocks (hazard ratio 0.50, 95%CI 0.25-0.98, P = 0.044), and had no impact on appropriate and ineffective shocks. CONCLUSIONS: In recent years, S-ICD implanting centres have increasingly programmed high arrhythmia detection cut-off rates, at the time of implantation in the case of new S-ICD recipients, and during follow-up in the case of pre-existing implants. This has contributed significantly to reducing the incidence of inappropriate shocks in clinical practice. Rordorf: Programming of the S-ICD. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Desfibriladores Implantáveis/efeitos adversos , Taquicardia Ventricular/diagnóstico , Seguimentos , Estudos Prospectivos , Cardioversão Elétrica , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia
2.
J Cardiovasc Electrophysiol ; 31(7): 1694-1701, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32369225

RESUMO

BACKGROUND: Ablation index (AI) is a new lesion quality marker that has been demonstrated to allow a high single-procedure arrhythmia-free survival in single-center studies. This prospective, multi-center study was designed to evaluate the reproducibility of pulmonary vein (PV) isolation guided by the AI. METHODS: A total of 490 consecutive patients with paroxysmal (80.4%) and persistent AF underwent first time PV isolation and were divided in four study groups according to operator's preference in choosing the ablation catheter (a contact force (ST) or contact force surround flow (STSF) catheter) and the AI setting (330-450 or 380-500 at anterior wall or posterior wall, respectively). RESULTS: At 12 months a high rate of freedom from AF recurrences was observed in patients with both paroxysmal and persistent AF (91% vs 83.3%; P = .039). There was no difference in the rate of AF recurrence among the four study groups (4.5% in group ST330-450, 12.2% in group ST 380-500, 14.9% in group STSF330-450, 9.4% in group STSF380-500; P = .083). Recurrence was also similar between patients treated with a ST (8%) or STSF catheter (12.1%; P = .2), and within patients targeting an AI settings of 330 to 450 (10.9%) or 380 to 500 (10.3%; P = .64). In patients with paroxysmal AF, there was no difference (P = .12) in the 1-year freedom from AF recurrence among 14 operators that performed ≥10 ablation procedure. CONCLUSIONS: An ablation protocol respecting strict criteria for contiguity and quality lesion resulted in high rate of 1-year freedom from AF recurrence, irrespective of the ablation catheters, AI settings, and operator.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Reprodutibilidade dos Testes , Resultado do Tratamento
3.
Europace ; 20(FI_3): f410-f418, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29315382

RESUMO

Aims: Real-time contact force (CF)-sensing radiofrequency ablation catheter for treatment of paroxysmal atrial fibrillation (PAF) allows optimization of electrode-tissue contact, which correlates with long-term success. This prospective, multicentre observational registry assessed the real-world clinical effectiveness of a CF-sensing catheter for ablation of drug-refractory PAF. Methods and results: Patients were followed-up at 3, 6, and 12 months after ablation. Outcome measures included isolation of targeted pulmonary veins (PVs) confirmed by entrance block (acute success), patient-reported freedom from symptomatic atrial fibrillation (AF) at 12 months (long-term effectiveness), Atrial Fibrillation Effect on Quality-of-life scores at 6 and 12 months, and incidence of predefined procedural complications. The registry enrolled 261 PAF patients (mean age 58.8 ± 11.3 years; 70.7% men; 91.7% Caucasian). Acute PV isolation was reported in 98.8% of patients [95% confidence interval (CI): 96.4-99.7%], and 12-month success for freedom from symptomatic AF was 75.7% (95% CI: 69.7-80.7%). Average CF for the evaluable cohort was 16.4 ± 3.9 g. There was a significant correlation between long-term effectiveness and stability of CF use [percentage of time CF was within investigator-selected working range; odds ratio (95% Wald CI), 1.0 (1.00-1.1); P = 0.030]. Average CF did not correlate with 12-month success. Clinically meaningful quality of life (QoL) improvements were observed at 6 and 12 months. Primary adverse events occurred in 2.7% patients. Conclusion: This observational registry showed that PAF ablation with a CF-sensing catheter had high acute success rates, favourable 12-month outcomes, and a good safety profile. Patients' QoL improved significantly. Long-term effectiveness significantly correlated with stable CF with adequate catheter-tissue contact (NCT01677052).


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Veias Pulmonares/cirurgia , Transdutores de Pressão , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Austrália , Canadá , Ablação por Cateter/efeitos adversos , Desenho de Equipamento , Europa (Continente) , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Intervalo Livre de Progressão , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Qualidade de Vida , Recidiva , Sistema de Registros , Fatores de Risco , Fatores de Tempo
4.
G Ital Cardiol (Rome) ; 23(2): 120-127, 2022 Feb.
Artigo em Italiano | MEDLINE | ID: mdl-35343516

RESUMO

BACKGROUND: Transvenous pacing is nowadays the cornerstone of interventional management of bradyarrhythmias. It is still associated, however, with significant complications, mostly related to indwelling transvenous leads or device pocket. In order to reduce these complications, leadless pacemakers have been recently introduced into clinical practice, but no guidelines are yet available to indicate who are those patients that might benefit the most and whether leadless pacing should be preferred in the old or young population. This survey aims to describe the use of leadless pacemaker devices in a real-world setting. METHODS: Eleven arrhythmia centers in the Lombardy region (out of a total of 17 participating centers) responded to the proposed questionnaire regarding patient characteristics and indications to leadless pacing. RESULTS: Out of a total of 411 patients undergoing leadless pacing during 4.2 ± 0.98 years, the median age was 77 years, with 0.18% of patients having less than 18 years, 29.9% 18-65 years, 34.3% 65-80 years and 35.6% >80 years. The most common indication was slow atrial fibrillation (49% of patients), followed by atrioventricular block and sinoatrial dysfunction. Two centers reported in-hospital complications. CONCLUSIONS: Leadless pacemakers proved to be a safe pacing strategy actually destined mostly to elderly patients.


Assuntos
Fibrilação Atrial , Bloqueio Atrioventricular , Marca-Passo Artificial , Idoso , Bloqueio Atrioventricular/terapia , Desenho de Equipamento , Humanos , Inquéritos e Questionários
5.
J Atr Fibrillation ; 12(2): 2126, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32002110

RESUMO

BACKGROUND: To investigate the real-world clinical experience of persistent atrial fibrillation (persAF) ablation using the THERMOCOOL SMARTTOUCH® catheter with contact force (CF)-sensing ability in a prospective, multicenter registry. METHODS: Patients with persAF (excluding long-standing persAF) undergoing ablation were enrolled. Primary adverse events (AEs), 12-month success, quality of life (QoL), and correlation of success with CF were assessed. RESULTS: Overall, 150 patients with persAF (age 61.6 ± 9.4 years; 76.0% male; 90.7% Caucasian; left ventricular ejection fraction 56.9% ± 10.3%; left atrial diameter 41.5 ± 7.9 mm) underwent catheter insertion (safety cohort); 142 met eligibility criteria and were ablated (evaluable cohort). Confirmation of entrance block for all targeted pulmonary veins was achieved in 99.3% of patients. The primary AE rate was 4.0% (6/150), and 12-month success was 63.1% (95% confidence interval: 54.2%-71.4%). A non-significant trend towards higher success was observed in patients with isoproterenol/adenosine challenge vs. those without (73.1% vs. 60.2%, respectively; P=0.065). Investigators stayed within their pre-selected CF working range (catheter-tissue contact stability) 79.7% ± 12.7% of the time. When investigators stayed within the CF range ≥80% vs. <80% of the time, ablation success was 69.2% vs. 58.5%, respectively (P=0.285). QoL improved significantly at 6 months and was sustained through the 12-month follow-up (P<0.0001). CONCLUSIONS: Symptom control in a real-world setting of persAF ablation using the THERMOCOOL SMARTTOUCH® catheter was 63.1%, with significant improvements in QoL, and trended non-significantly towards increased success in patients receiving isoproterenol/adenosine challenge and when investigators stayed within their pre-selected CF range ≥80% of the time.

6.
J Interv Card Electrophysiol ; 51(3): 245-252, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29502194

RESUMO

PURPOSE: Latency during left ventricle (LV) pacing has been suggested as a potential cause of ineffectual biventricular pacing. We assessed the incidence, predictors, and impact on outcome of increased LV latency in 274 patients undergoing cardiac resynchronization therapy (CRT). METHODS: On implantation, the latency interval was defined as the shortest stimulus-to-QRS onset interval in any lead of the 12-lead ECG. A stimulus-to-QRS onset interval ≥ 40 ms was used to define the presence of increased LV latency. RESULTS: Increased LV latency was observed in 55 patients (20%). On multivariate analysis, only ischemic etiology proved to be a predictor of increased LV latency. On 12-month echocardiographic evaluation, 68% patients showed a ≥ 15% decrease in LV end systolic volume (74% patients with increased LV latency, 67% patients without increased LV latency (p = 0.58). The presence of increased LV latency was not associated with a different clinical response to CRT. CONCLUSIONS: Increased LV latency occurred in almost 20% of patients undergoing CRT and was more frequent in patients with ischemic heart disease. The presence of increased LV latency does not seem to have an impact on echocardiographic or clinical response to CRT.


Assuntos
Estimulação Cardíaca Artificial/métodos , Eletrocardiografia , Insuficiência Cardíaca/terapia , Isquemia Miocárdica/terapia , Idoso , Análise de Variância , Estimulação Cardíaca Artificial/mortalidade , Terapia de Ressincronização Cardíaca/métodos , Terapia de Ressincronização Cardíaca/mortalidade , Estudos de Coortes , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/mortalidade , Prognóstico , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/terapia
7.
Circ Arrhythm Electrophysiol ; 11(3): e005592, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29874166

RESUMO

BACKGROUND: This multicenter, prospective study evaluated the determinants of zero-fluoroscopy (ZFL) ablation of supraventricular tachycardias. METHODS AND RESULTS: Four hundred thirty patients (215 male, 55.4±22.1 years) with indication to electrophysiological study or ablation of supraventricular tachycardias were enrolled. All participating physicians agreed to follow the as low as reasonably achievable policy. A procedure was defined as ZFL when no fluoroscopy was used. The total fluoroscopy time inversely correlated to the number of procedures previously performed by each operator since study start (r=-0.112; P=0.02). Two hundred eighty-nine procedures (67.2%) were ZFL; multivariable analysis identified as predictors of ZFL: procedure after the 30th for each operator, compared with procedures up to the ninth (P=0.011; hazard ratio, 3.49; 95% confidence interval [CI], 1.79-6.80); the type of arrhythmia (P=0.031; electrophysiological study and atrioventricular nodal reentry tachycardia ablation having the highest probability of ZFL; hazard ratio, 6.87; 95% CI, 2.08-22.7 and hazard ratio, 2.02; 95% CI, 1.04-3.91, respectively); the operator's (P=0.002) and patient's age (P=0.009). Among operators, achievement of ZFL varied from 0% to 100%; 8 (22.8%) operators achieved ZFL in <25% of their procedures; 17 (48.6%) operators achieved ZFL in >75% of their procedures. The probability of ZFL increased by 2.8% (hazard ratio, 0.98; 95% CI, 0.97-0.99) as patient's age decreased by 1 year. Acute procedural success was obtained in all cases. CONCLUSIONS: The use of 3-dimensional mapping system completely avoided the use of fluoroscopy in most cases, with very low fluoroscopy time in the remaining and high safety and effectiveness profiles. Achievement of ZFL was predicted by the type of arrhythmia, operator's experience, and patient's age.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Fluoroscopia/métodos , Cirurgia Assistida por Computador/métodos , Taquicardia Supraventricular/cirurgia , Feminino , Seguimentos , Humanos , Imageamento Tridimensional , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento