Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Wound Care ; 32(9): 587-596, 2023 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-37682784

RESUMO

OBJECTIVE: To investigate reliability and changes of in-shoe plantar pressure and shear during walking at three cadences with two insole designs. This was a precursor to the investigation of plantar loading in people with diabetes for potential foot ulcer prevention. METHOD: A sensorised insole system, capable of measuring plantar pressure and shear at the heel, fifth metatarsal head (5MH), first metatarsal head (1MH) and hallux, was tested with ten healthy participants during level walking. Reliability was evaluated, using intra-class correlation coefficient (ICC), while varying the cadences and insole types. Percentage changes in pressure and shear relative to values obtained at self-selected cadence with a flat insole design were investigated. RESULTS: Mean±standard deviation of maximum pressure, medial-lateral and anterior-posterior shear of up to 380±24kPa, 46±2kPa and -71±4kPa, respectively, were measured. The ICC in ranges of 0.762-0.973, 0.758-0.987 and 0.800-0.980 were obtained for pressure, anterior-posterior and medial-lateral shear, respectively. Opposite anterior-posterior shear directions between 5MH and 1MH (stretching), and between 1MH and hallux (pinching) were observed for some participants. Increasing cadence increased pressure and anterior-posterior shear (by up to +77%) but reduced medial-lateral shear at the heel and hallux (by up to -34%). Slower cadence increased anterior-posterior shear (+114%) but decreased medial-lateral shear (-46%) at the hallux. The use of a flexible contoured insole resulted in pressure reduction at the heel and 5MH but an increase in anterior-posterior shear at the heel (+69%) and hallux (+75%). CONCLUSION: The insole system demonstrated good reliability and is comparable to reported pressure-only systems. Pressure measurements were sensitive to changes in cadence and insole designs in ways that were consistent with the literature. However, our plantar shear showed localised shear changes with cadences and insoles for the first time, as well as stretching and pinching effects on plantar tissue. This opens new possibilities to investigate plantar tissue viability, loading characteristics and orthotic designs aimed towards foot ulcer prevention.


Assuntos
Diabetes Mellitus , Pé Diabético , Humanos , Pé Diabético/prevenção & controle , Reprodutibilidade dos Testes , Sapatos , Voluntários Saudáveis , Caminhada
2.
Sensors (Basel) ; 23(6)2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36991838

RESUMO

Pressure coupled with shear stresses are the critical external factors for diabetic foot ulceration assessment and prevention. To date, a wearable system capable of measuring in-shoe multi-directional stresses for out-of-lab analysis has been elusive. The lack of an insole system capable of measuring plantar pressure and shear hinders the development of an effective foot ulcer prevention solution that could be potentially used in a daily living environment. This study reports the development of a first-of-its-kind sensorised insole system and its evaluation in laboratory settings and on human participants, indicating its potential as a wearable technology to be used in real-world applications. Laboratory evaluation revealed that the linearity error and accuracy error of the sensorised insole system were up to 3% and 5%, respectively. When evaluated on a healthy participant, change in footwear resulted in approximately 20%, 75% and 82% change in pressure, medial-lateral and anterior-posterior shear stress, respectively. When evaluated on diabetic participants, no notable difference in peak plantar pressure, as a result of wearing the sensorised insole, was measured. The preliminary results showed that the performance of the sensorised insole system is comparable to previously reported research devices. The system has adequate sensitivity to assist footwear assessment relevant to foot ulcer prevention and is safe to use for people with diabetes. The reported insole system presents the potential to help assess diabetic foot ulceration risk in a daily living environment underpinned by wearable pressure and shear sensing technologies.


Assuntos
Diabetes Mellitus , Pé Diabético , Órtoses do Pé , Dispositivos Eletrônicos Vestíveis , Humanos , Pé Diabético/diagnóstico , Pé Diabético/prevenção & controle , , Sapatos , Pressão
3.
Artif Organs ; 42(12): 1224-1233, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29761832

RESUMO

Tactile vision substitution devices present visual images as tactile representations on the skin. In this study we have tested the performance of a prototype 96-tactor vibrotactile using a subset of 64 tactors. We have determined the tactile spatial acuity and intensity discrimination in 14 naïve subjects. Spatial acuity was determined using a grating acuity task. Subjects could successfully identify the orientation of horizontal and vertical gratings with an average psychophysical threshold of 120 mm. When diagonal gratings were included in the analysis, the median performance dropped below psychophysical threshold, but was still significantly above chance at gratings of 142 mm wide. Intensity discrimination yielded an average Weber fraction of 0.44, corresponding to 13 discernable "gray levels" in the available dynamic range. Interleaved stimulation of the motors did not significantly affect spatial acuity or intensity discrimination.


Assuntos
Auxiliares Sensoriais , Detecção de Sinal Psicológico , Tato , Adulto , Feminino , Humanos , Masculino , Vibração , Adulto Jovem
4.
Artif Organs ; 41(11): 1059-1070, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28569046

RESUMO

Tactile vision substitution devices are assistive technologies for the blind that redirect visual information to the tactile sense. They typically include a tactile display that conveys visual information to the skin. Two important parameters that determine the maximum information bandwidth of tactile displays are the spatial acuity of the skin, and the ability of the user to discriminate between stimulus intensities. These two parameters were investigated by determining the two-point discrimination (TPD) threshold and the just-noticeable intensity difference (JND) using coin motors on the lower back. Coin motors are eccentric rotating-mass motors that are affordable, energy-efficient, and easy to implement. The lower back was chosen because it is a discreet place to wear assistive technology. It is generally available for use, as it is usually not critically involved in activities of daily living. Rehabilitation with sensory substitution devices often requires training by professional occupational therapists, because the user needs to extract visual information from sparse information presented through an alternative channel such as the skin. In this study they determined whether short, automated training sessions of 5 min each could improve the TPD threshold and JND. It was found that 10 min of computer-assisted training improved the vibrotactile TPD threshold on the lower back by 36%, and that 18 min of training improved the just-noticeable intensity difference (JND) by 44%. It was concluded that short, automated training sessions could provide a fast and inexpensive means to improve people's basic spatial acuity and intensity discrimination skills with coin motors.


Assuntos
Discriminação Psicológica , Estimulação Física/instrumentação , Limiar Sensorial , Fenômenos Fisiológicos da Pele , Pele/inervação , Percepção Espacial , Percepção do Tato , Vibração , Adulto , Desenho de Equipamento , Feminino , Humanos , Região Lombossacral , Masculino , Pessoa de Meia-Idade , Estimulação Física/métodos , Detecção de Sinal Psicológico , Adulto Jovem
5.
Artif Organs ; 39(6): 480-91, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25586668

RESUMO

We have tested the potential of three types of vibration motors for use in a tactile vision substitution device for the blind. The motors were of the coin type, which are available off-the-shelf, and are characterized by their affordability, energy efficiency, and ease of implementation. The primary limitation of coin motors is the lack of control they offer over stimulus parameters. Specifically, adjusting the input voltage of a coin motor not only changes the vibration intensity, but also the vibration frequency and duration. This characteristic may result in unpredictable perceptions in psychophysical tests. By using standard psychophysical procedures, we were able to show that the tested coin motors evoked predictable magnitude perceptions across their dynamic range, following Fechner's law as if vibration intensity alone were varied. The best-performing motor was able to generate a median number of 15 available just-noticeable differences, meaning that it was potentially capable of conveying 16 gray levels in its dynamic range. We conclude that coin motors are potential candidates for the construction of a tactile display to substitute for lost vision.


Assuntos
Cegueira , Tato/fisiologia , Vibração , Pessoas com Deficiência Visual , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
6.
Materials (Basel) ; 17(14)2024 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-39063875

RESUMO

Al-Zn-Mg-Si alloy coatings have been developed to inhibit the corrosion of cold-rolled steel sheets by offering galvanic and barrier protection to the substrate steel. It is known that Fe deposited from the steel strip modifies the microstructure of the alloy. We cast samples of Al-Zn-Mg-Si coating alloys containing 0.4 wt% Fe and directionally solidified them using a Bridgman furnace to quantify the effect of this Fe addition between 600 °C and 240 °C. By applying a temperature gradient, growth is encouraged, and by then quenching the sample in coolant, the microstructure may be frozen. These samples were analysed using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS) to determine the morphological effects of the Fe distribution across the experimental temperature range. However, due to the sub 1 wt% concentration of Fe, synchrotron X-ray fluorescence microscopy (XFM) was applied to quantitatively confirm the Fe distribution. Directionally solidified samples were scanned at 7.05 keV and 18.5 keV using X-ray fluorescence at the Australian Synchrotron using the Maia array detector. It was found that a mass nucleation event of the Fe-based τ6 phase occurred at 495 °C following the nucleation of the primary α-Al phase as a result of a peritectic reaction with remaining liquid.

7.
Trials ; 23(1): 286, 2022 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-35410282

RESUMO

BACKGROUND: Children with symptomatic flat feet (pes planus) frequently present for care but there remains uncertainty about how best to manage their condition. There is considerable variation in practice between and within professions. We intend to conduct a three-arm trial to evaluate three frequently used interventions for pes planus (exercise and advice, exercise and advice plus prefabricated orthoses, and exercise and advice plus custom made orthoses). Each of these interventions are complex and required developing prior to starting the trial. This paper focusses on the development process undertaken to develop the interventions. METHODS: We used a modified Nominal Group Technique combining an electronic survey with two face-to-face meetings to achieve consensus on the final logic model and menu of options for each intervention. Using the Nominal Group Technique across consecutive meetings in combination with a questionnaire is novel, and enabled us to develop complex interventions that reflect contemporary clinical practice. RESULTS: In total 16 healthcare professionals took part in the consensus. These consisted of 11 podiatrists, two orthotists, two physiotherapists, and one orthopaedic surgeon. Both meetings endorsed the logic model with amendments to reflect the wider psychosocial impact of pes planus and its treatment, as well as the increasing use of shared decision making in practice. Short lists of options were agreed for prefabricated and custom made orthoses, structures to target in stretching and strengthening exercises, and elements of health education and advice. CONCLUSIONS: Our novel modification of the nominal group technique produced a coherent logic model and shortlist of options for each of the interventions that explicitly enable adaptability. We formed a consensus on the range of what is permissible within each intervention so that their integrity is kept intact and they can be adapted and pragmatically applied. The process of combining survey data with face-to-face meetings has ensured the interventions mirror contemporary practice and may provide a template for other trials.


Assuntos
Pé Chato , Fisioterapeutas , Criança , Terapia por Exercício/métodos , Pé Chato/terapia , Humanos , Aparelhos Ortopédicos , Inquéritos e Questionários
9.
IEEE Trans Haptics ; 9(4): 446-454, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27214917

RESUMO

Tactile vision substitution devices are assistive devices for the blind that redirect visual information to the skin. The amount of visual information that can be presented on a tactile display is limited mainly by the spatial resolution of the skin and the ability to distinguish between various vibration intensities. In this study, we have determined the two-point discrimination (TPD) threshold and intensity-discrimination threshold (just-noticeable difference, or JND) on the lower back using coin motors. Given the importance of stimulus timing, we have determined TPD threshold and JND at different stimulus onset asynchronies (SOAs). The JND was determined between two coin motors with a distance equal to the TPD threshold. In this way, we could establish the contrast sensitivity at the maximal theoretical resolution. TPD thresholds tended to decrease at longer SOAs, from 52 mm edge-to-edge at an SOA of 0 ms, to 28 mm at 200 ms. The JND did not depend on SOA, and the average Weber fraction was 0.14. A median of 5 JNDs was available across the available dynamic range. Together, these data provide the predicted spatial resolution and contrast resolution achievable with a back-worn tactile display based on coin motors.


Assuntos
Discriminação Psicológica/fisiologia , Limiar Sensorial/fisiologia , Percepção Espacial/fisiologia , Percepção do Tato/fisiologia , Vibração , Adulto , Limiar Diferencial/fisiologia , Humanos , Região Lombossacral/fisiologia , Estimulação Física
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa