Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 160
Filtrar
1.
J Vasc Interv Radiol ; 35(5): 648-657.e1, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38244917

RESUMO

PURPOSE: To investigate effects of baseline and early longitudinal body composition changes on mortality and hepatic encephalopathy (HE) after transjugular intrahepatic portosystemic shunt (TIPS). MATERIALS AND METHODS: This is a case-control study with analysis of a TIPS registry (1995-2020) including data from patients with cirrhosis with computed tomography (CT) scans obtained within 1 month before and 3 months after TIPS. Core muscle area (CMA), macroscopic subcutaneous adipose tissue (mSAT), macroscopic visceral adipose tissue (mVAT) area, and muscle adiposity index (MAI) on CT were obtained. Multipredictor Cox proportional hazards models were used to assess the effect of body composition variables on mortality or HE. RESULTS: In total, 280 patients (158 men; median age, 57.0 years; median Model for End-stage Liver Disease-sodium [MELD-Na] score, 14.0) were included. Thirty-four patients had post-TIPS imaging. Median baseline CMA was 68.3 cm2 (interquartile range, 57.7-83.5 cm2). Patients with higher baseline CMA had decreased risks of mortality (hazard ratio [HR]: 0.82; P = .04) and HE (HR: 0.82; P = .009). It improved prediction of mortality over MELD-Na and post-TIPS right atrial pressure alone (confidence interval = 0.729). An increase in CMA (HR: 0.60; P = .043) and mSAT (HR: 0.86; P = .022) or decrease in MAI (HR: 1.50; P = .049) from before to after TIPS was associated with a decreased risk of mortality. An increase in mSAT was associated with an increased risk of HE (HR: 1.11; P = .04). CONCLUSIONS: CMA on CT scan 1 month before TIPS placement predicts mortality and HE in patients with cirrhosis. Changes in body composition on CT measured 3 months after TIPS placement independently predict mortality and HE.


Assuntos
Encefalopatia Hepática , Cirrose Hepática , Derivação Portossistêmica Transjugular Intra-Hepática , Valor Preditivo dos Testes , Sistema de Registros , Humanos , Derivação Portossistêmica Transjugular Intra-Hepática/efeitos adversos , Derivação Portossistêmica Transjugular Intra-Hepática/mortalidade , Masculino , Feminino , Pessoa de Meia-Idade , Encefalopatia Hepática/etiologia , Encefalopatia Hepática/mortalidade , Encefalopatia Hepática/diagnóstico por imagem , Encefalopatia Hepática/fisiopatologia , Fatores de Risco , Medição de Risco , Idoso , Fatores de Tempo , Cirrose Hepática/mortalidade , Cirrose Hepática/diagnóstico por imagem , Resultado do Tratamento , Adiposidade , Composição Corporal , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Estudos de Casos e Controles
2.
Ann Vasc Surg ; 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38960094

RESUMO

Vascular access for hemodialysis is the lifeline for patients with end-stage renal disease (ESRD); therefore, maintenance of the vascular access is of the utmost importance. The dialysis circuit can be complicated by stenosis or thrombosis. In particular, central venous stenosis is frequently encountered in the vascular access of patients with ESRD, and this complication may require endovascular management. Conventional catheter-based venography may be inadequate for identifying dynamic forms of extrinsic compression and intravascular webs associated with these lesions. For these types of access complications, balloon angioplasty remains the first-line intervention, with stenting reserved for select scenarios. Accurate assessment of the venous configuration is therefore important to ensure an adequate treatment response. Intravascular ultrasound (IVUS) has been shown to be beneficial in lower extremity venous interventions. The use of IVUS in dialysis access interventions is currently limited but may be indicated in select challenging clinical situations. In this article, we discuss the potential uses of IVUS in the ESRD population based on our institutional experience and on the current literature.

3.
BMC Gastroenterol ; 23(1): 241, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37460992

RESUMO

PURPOSE: To evaluate efficacy, safety, and outcomes of endovascular treatment of hepatic vein stenosis post major liver resection. METHODS: A retrospective data analysis was performed including all interventional treatments of hepatic vein stenosis post major liver resection since 2010. Post procedural course and clinical parameters including amount of ascites accumulation and relevant laboratory values were assessed during the follow-up period. Primary and primary assisted hepatic venous patency time were calculated. RESULTS: Twelve patients (median age 55.5, IQR 49.75 to 61.5 years) undergoing a total of 16 interventions were included. Interventions were primary stent placement (n = 3), primary balloon angioplasty (n = 8), three re-interventions and two aborted interventions (no significant pressure gradient). Technical success was 100% (16/16). Permanent reduction and / or complete resolution of ascites was achieved in 72% (8/11). Laboratory parameters related to liver function did not show significant improvement after intervention. Median follow-up period was 6 months (IQR: 1.5 to 18 months). The median primary patency time for patients with balloon angioplasty was 11 months (IQR: 1.375 to 22.25 months) and assisted patency time was 13.25 months (IQR: 4.5 to 22.25 months). The median primary patency time for patients with angioplasty and stent placement was 1 months (IQR: 1.0 to 1.5 months) and assisted patency time was 2.0 months (IQR: 1.5 to 2.5months). CONCLUSION: An endovascular approach for the treatment of hepatic venous stenosis post major liver resection is safe and efficient to reduce and / or resolve refractory ascites. However, liver function parameters seem not to be improved by the procedure. Stent placement can be a reasonable option in patients with significant residual stenotic disease post angioplasty.


Assuntos
Angioplastia com Balão , Síndrome de Budd-Chiari , Procedimentos Endovasculares , Transplante de Fígado , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Ascite/etiologia , Ascite/terapia , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Resultado do Tratamento , Angioplastia com Balão/métodos , Stents
4.
Vasc Med ; 28(6): 592-603, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37792749

RESUMO

The spectrum of venous thromboembolic (VTE) disease encompasses both acute deep venous thrombosis (DVT) and chronic postthrombotic changes (CPC). A large percentage of acute DVT patients experience recurrent VTE despite adequate anticoagulation, and may progress to CPC. Further, the role of iliocaval venous obstruction (ICVO) in lower-extremity VTE has been increasingly recognized in recent years. Imaging continues to play an important role in both acute and chronic venous disease. Venous duplex ultrasound remains the gold standard for diagnosing acute VTE. However, imaging of CPC is more complex and may involve computed tomography, magnetic resonance, contrast-enhanced ultrasound, or intravascular ultrasound. In this narrative review, we aim to discuss the full spectrum of venous disease imaging for both acute and chronic venous thrombotic disease.


Assuntos
Síndrome Pós-Trombótica , Tromboembolia Venosa , Trombose Venosa , Humanos , Tromboembolia Venosa/diagnóstico por imagem , Veias , Trombose Venosa/diagnóstico por imagem , Extremidade Inferior/irrigação sanguínea , Doença Crônica , Doença Aguda
5.
Eur Radiol ; 32(8): 5222-5232, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35267088

RESUMO

OBJECTIVES: To assess diagnostic accuracy of automated 3D volumetry of cardiac chambers based on computed tomography pulmonary angiography (CTPA) for the differentiation of pulmonary hypertension due to left heart disease (group 2 PH) from non-group 2 PH compared to manual diameter measurements. METHODS: Patients with confirmed PH undergoing right heart catheterisation and CTPA within 100 days for diagnostic workup of PH between August 2013 and February 2016 were included in this retrospective, single-centre study. Automated 3D segmentation of left atrium, left ventricle, right atrium and right ventricle (LA/LV/RA/RV) was performed by two independent and blinded radiologists using commercial software. For comparison, axial diameters were manually measured. The ability to differentiate group 2 PH from non-group 2 PH was assessed by means of logistic regression. RESULTS: Ninety-one patients (median 67.5 years, 44 women) were included, thereof 19 patients (20.9%) classified as group 2 PH. After adjustment for age, sex and mean pulmonary arterial pressure, group 2 PH was significantly associated with larger LA volume (p < 0.001), larger LV volume (p = 0.001), lower RV/LV volume ratio (p = 0.04) and lower RV/LA volume ratio (p = 0.003). LA volume demonstrated the highest discriminatory ability to identify group 2 PH (AUC, 0.908; 95% confidence interval, 0.835-0.981) and was significantly superior to LA diameter (p = 0.009). Intraobserver and interobserver agreements were excellent for all volume measurements (intraclass correlation coefficients 0.926-0.999, all p < 0.001). CONCLUSIONS: LA volume quantified by automated, CTPA-based 3D volumetry can differentiate group 2 PH from other PH groups with good diagnostic accuracy and yields significantly higher diagnostic accuracy than left atrial diameter. KEY POINTS: • Automated cardiac chamber volumetry using non-gated CT pulmonary angiography can differentiate pulmonary hypertension due to left heart disease from other causes with good diagnostic accuracy. • Left atrial volume yields significantly higher diagnostic accuracy than left atrial axial diameter for identification of pulmonary hypertension due to left heart disease without time-consuming manual processing.


Assuntos
Cardiopatias , Hipertensão Pulmonar , Angiografia/métodos , Feminino , Átrios do Coração , Ventrículos do Coração/diagnóstico por imagem , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
6.
Vasa ; 50(1): 2-10, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33138741

RESUMO

Intravascular ultrasound (IVUS) has been used extensively in coronary applications. Its use in venous applications has increased as endovascular therapy has increasingly become the mainstay therapy for central venous diseases. IVUS has been used for both diagnostic and therapeutic purposes in managing venous stenotic disease, venous occlusive disease, and IVC filter placement and removal. IVUS has been proven to be effective in providing detailed measurement of the venous anatomy, which aid in determining the appropriate size and the approach for venous stent placement. In IVC filter placement, IVUS can provide detailed measurement and guide IVC filter placement in emergent and critical care settings. It also has certain utility in filter removal. At any rate, to date there are only a few studies examining its impact on patient outcomes. Prospective randomized controlled trials are warranted in the future.


Assuntos
Ultrassonografia de Intervenção/métodos , Filtros de Veia Cava , Veia Cava Inferior/diagnóstico por imagem , Trombose Venosa/terapia , Idoso , Constrição Patológica , Veia Femoral/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Trombose Venosa/diagnóstico por imagem
7.
Vasa ; 49(6): 449-462, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32660360

RESUMO

Inferior vena cava (IVC) filter has been used to manage patients with pulmonary embolism and deep venous thrombosis. Its ease of use and the expansion of relative indications have led to a dramatic increase in IVC filter placement. However, IVC filters have been associated with a platitude of complications. Therefore, there exists a need to examine the current indications and identify the patient population at risk. In this paper, we comprehensively reviewed the current indications and techniques of IVC filter placement. Further, we examined the various complications associated with either permanent or retrievable IVC filters. Lastly, we examined the current data on filter retrieval.


Assuntos
Embolia Pulmonar , Filtros de Veia Cava , Remoção de Dispositivo , Humanos , Embolia Pulmonar/etiologia , Embolia Pulmonar/prevenção & controle , Estudos Retrospectivos , Filtros de Veia Cava/efeitos adversos , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia
8.
Eur Radiol ; 29(11): 6059-6068, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30963276

RESUMO

OBJECTIVES: To assess the diagnostic accuracy of automated 3D volumetry of central pulmonary arteries using computed tomography pulmonary angiography (CTPA) for suspected pulmonary hypertension alone and in combination with echocardiography. METHODS: This retrospective diagnostic accuracy study included 70 patients (mean age 66.7, 48 female) assessed for pulmonary hypertension by CTPA and transthoracic echocardiography with estimation of the pulmonary arterial systolic pressure (PASP). Gold standard right heart catheterisation with measurement of the invasive mean pulmonary arterial pressure (invasive mPAP) served as the reference. Volumes of the main, right and left pulmonary arteries (MPA, RPA and LPA) were computed using automated 3D segmentation. For comparison, axial dimensions were manually measured. A linear regression model was established for prediction of mPAP (predicted mPAP). RESULTS: MPA, RPA and LPA volumes were significantly increased in patients with vs. without pulmonary hypertension (all p < 0.001). Of all measures, MPA volume demonstrated the strongest correlation with invasive mPAP (r = 0.76, p < 0.001). Predicted mPAP using MPA volume and echocardiographic PASP as covariates showed excellent correlation with invasive mPAP (r = 0.89, p < 0.001). Area under the curves for predicting pulmonary hypertension were 0.94 for predicted mPAP, compared to 0.90 for MPA volume and 0.92 for echocardiographic PASP alone. A predicted mPAP > 25.8 mmHg identified pulmonary hypertension with sensitivity, specificity, positive and negative predictive values of 86%, 93%, 95% and 81%, respectively. CONCLUSIONS: Automated 3D volumetry of central pulmonary arteries based on CTPA may be used in conjunction with echocardiographic pressure estimates to noninvasively predict mPAP and pulmonary hypertension as confirmed by gold standard right heart catheterisation with higher diagnostic accuracy than either test alone. KEY POINTS: • This diagnostic accuracy study derived a regression model for noninvasive prediction of invasively measured mean pulmonary arterial pressure as assessed by gold standard right heart catheterisation. • This regression model using automated 3D volumetry of the central pulmonary arteries based on CT pulmonary angiography in conjunction with the echocardiographic pressure estimate predicted pulmonary arterial pressure and the presence of pulmonary hypertension with good diagnostic accuracy. • The combination of automated 3D volumetry and echocardiographic pressure estimate in the regression model provided superior diagnostic accuracy compared to each parameter alone.


Assuntos
Pressão Sanguínea/fisiologia , Angiografia por Tomografia Computadorizada/métodos , Ecocardiografia/métodos , Hipertensão Pulmonar/diagnóstico , Imageamento Tridimensional/métodos , Pulmão/diagnóstico por imagem , Artéria Pulmonar/diagnóstico por imagem , Idoso , Cateterismo Cardíaco , Feminino , Humanos , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sístole
9.
J Vasc Interv Radiol ; 30(3): 380-389.e4, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30819480

RESUMO

PURPOSE: To compare different imaging techniques (volume perfusion CT, cone-beam CT, and dynamic gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced dynamic contrast-enhanced MR imaging with golden-angle radial sparse parallel MR imaging) in evaluation of transarterial chemoembolization of hepatocellular carcinoma (HCC) using radiopaque drug-eluting embolics (DEE). MATERIALS AND METHODS: MR imaging and CT phantom investigation of radiopaque DEE was performed. In the clinical portion of the study, 13 patients (22 HCCs) were prospectively enrolled. All patients underwent cross-sectional imaging before and after transarterial chemoembolization using 100-300 µm radiopaque DEE. Qualitative assessment of images using a Likert scale was performed. RESULTS: In the phantom study, CT-related beam-hardening artifacts were markedly visible at a concentration of 12% (v/v) radiopaque DEE; MR imaging demonstrated no significant detectable signal intensity changes. Imaging obtained before transarterial chemoembolization showed no significant difference regarding tumor depiction. Visualization of tumor feeding arteries was significantly improved with volume perfusion CT (P < .001) and cone-beam CT (P = .002) compared with MR imaging. Radiopaque DEE led to significant decrease in tumor depiction (P = .001) and significant increase of beam-hardening artifacts (P = .012) using volume perfusion CT before versus after transarterial chemoembolization. Greater residual arterial tumor enhancement was detected with MR imaging (10 HCCs) compared with volume perfusion CT (8 HCCs) and cone-beam CT (6 HCCs). CONCLUSIONS: Using radiopaque DEE, the imaging modalities provided comparable early treatment assessment. In HCCs with dense accumulation of radiopaque DEE, treatment assessment using volume perfusion CT or cone-beam CT may be impaired owing to resulting beam-hardening artifacts and contrast stasis. Dynamic contrast-enhanced MR imaging may add value in detection of residual arterial tumor enhancement.


Assuntos
Antibióticos Antineoplásicos/administração & dosagem , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Doxorrubicina/administração & dosagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão/métodos , Álcool de Polivinil/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Antibióticos Antineoplásicos/efeitos adversos , Artefatos , Carcinoma Hepatocelular/patologia , Quimioembolização Terapêutica/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/instrumentação , Meios de Contraste/administração & dosagem , Doxorrubicina/efeitos adversos , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/instrumentação , Masculino , Microesferas , Pessoa de Meia-Idade , Imagem de Perfusão/instrumentação , Imagens de Fantasmas , Álcool de Polivinil/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Resultado do Tratamento
10.
J Ultrasound Med ; 38(10): 2541-2557, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30714653

RESUMO

Since its introduction, contrast-enhanced ultrasound (CEUS) has gained an important role in the diagnosis and management of abdominal and pelvic diseases. Contrast-enhanced ultrasound can improve lesion detection rates as well as success rates of interventional procedures when compared to conventional ultrasound alone. Additionally, CEUS enables the interventionalist to assess the dynamic enhancement of different tissues and lesions, without the adverse effects of contrast-enhanced computed tomography, such as exposure to ionizing radiation and nephrotoxicity from iodinated contrast material. This review article describes the various applications and advantages of the use of CEUS to enhance performance of ultrasound-guided interventions in the abdomen and pelvis.


Assuntos
Meios de Contraste , Doenças do Sistema Digestório/diagnóstico por imagem , Doenças Urogenitais Femininas/diagnóstico por imagem , Aumento da Imagem/métodos , Doenças Urogenitais Masculinas/diagnóstico por imagem , Esplenopatias/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Abdome/diagnóstico por imagem , Feminino , Humanos , Masculino , Pelve/diagnóstico por imagem
11.
Vasa ; 48(2): 115-125, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30324867

RESUMO

Ultrasound has been established as an important diagnostic tool in assessing vascular abnormalities. Standard B-mode and Doppler techniques have inherent limitations with regards to detection of slow flow and small vasculature. Contrast-enhanced ultrasound (CEUS) is a complementary tool and is useful in assessing both the macro- and microvascular anatomy of the aorta. CEUS can also provide valuable physiological information in real-time scanning sessions due to the physical and safety profiles of the administered microbubbles. From a macrovascular perspective, CEUS has been used to characterize aortic aneurysm rupture, dissection and endoleaks post-EVAR repair. With regard to microvasculature CEUS enables imaging of adventitial vasa vasorum thereby assessing aortic inflammation processes, such as monitoring treatment response in chronic periaortitis. CEUS may have additional clinical utility since adventitial vasa vasorum has important implications in the pathogenesis of aortic diseases. In recent years, there have been an increasing number of studies comparing CEUS to cross-sectional imaging for aortic applications. For endoleak surveillance CEUS has been shown to be equal or in certain cases superior in comparison to CT angiography. The recent advancement of CEUS software along with the ongoing development of drug-eluting contrast microbubbles has allowed improved targeted detection and real-time ultrasound guided therapy for aortic vasa vasorum inflammation and neovascularization in animal models. Therefore, CEUS is uniquely suited to comprehensively assess and potentially treat aortic vascular diseases in the future.


Assuntos
Aorta Abdominal , Aneurisma da Aorta Abdominal , Meios de Contraste , Endoleak , Humanos , Ultrassonografia
12.
Skeletal Radiol ; 47(6): 811-819, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29330619

RESUMO

OBJECTIVE: To retrospectively compare the diagnostic performance of isotropic 3D steady-state free precession (3D-SSFP) sequences with 2D turbo spin-echo proton density-weighted fat-saturated (2D-TSE-PD fs) images in hip magnetic resonance arthrography; arthroscopy was a standard of reference. METHODS: Eighty-one patients with suspected labral tears who underwent hip MR arthrography (3-T scanner) were included. 2D-TSE-PD fs sequences were acquired in three planes and a singular sagittal 3D-SSFP. Labral tears, cartilage pathology and bone marrow were independently assessed by two blinded radiologists using a 5-point Likert scale. Accuracy was determined in 39 patients using invasive arthroscopy. RESULTS: Diagnostic confidence of labral and cartilaginous pathologies based on image quality was rated higher for 3D-SSFP (4.5 ± 0.8; 4.35 ± 0.7; p < 0.0001), but inferior for bone marrow pathology (3.9 ± 0.7; 4.0 ± 0.7; p < 0.0001). In the arthroscopy patients, similar sensitivity (85.9%) but higher specificity (74.4vs.42.9%) and higher positive and negative predictive values were found in 3D-SSFP of labral and cartilage pathologies. CONCLUSIONS: 3D-SSFP in hip magnetic resonance arthrography offers increased accuracy in detecting labral and cartilage pathologies compared with 2D-TSE-PD, while reducing the acquisition time. A drawback of 3D-SSFP was the inferior diagnostic confidence for bone marrow evaluation; thus, 3D-SSFP should be combined with conventional 2D-TSE sequences.


Assuntos
Lesões do Quadril/diagnóstico por imagem , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Adulto , Artroscopia , Artefatos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
14.
Vasa ; 47(5): 345-359, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29806797

RESUMO

The pulmonary arteries are affected by a variety of congenital and acquired abnormalities. Multiple state-of-the art imaging modalities are available to evaluate these pulmonary arterial abnormalities, including computed tomography (CT), magnetic resonance imaging (MRI), echocardiography, nuclear medicine imaging and catheter pulmonary angiography. In part one of this two-part series on state-of-the art pulmonary arterial imaging, we review these imaging modalities, focusing particularly on CT and MRI. We also review the utility of these imaging modalities in the evaluation of pulmonary thromboembolism.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia por Ressonância Magnética , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Doença Aguda , Doença Crônica , Ecocardiografia , Humanos , Imagem de Perfusão , Valor Preditivo dos Testes , Prognóstico , Artéria Pulmonar/fisiopatologia , Circulação Pulmonar , Embolia Pulmonar/fisiopatologia , Embolia Pulmonar/terapia , Fluxo Sanguíneo Regional , Tomografia Computadorizada de Emissão
15.
Vasa ; 47(5): 361-375, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29806799

RESUMO

Although pulmonary embolism is the most common abnormality of the pulmonary artery, there is a broad spectrum of other congenital and acquired pulmonary arterial abnormalities. Multiple imaging modalities are now available to evaluate these abnormalities of the pulmonary arteries. CT and MRI are the most commonly used cross-sectional imaging modalities that provide comprehensive information on several aspects of these abnormalities, including morphology, function, risk-stratification and therapy-monitoring. In this article, we review the role of state-of-the-art pulmonary arterial imaging in the evaluation of non-thromboembolic disorders of pulmonary artery.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia por Ressonância Magnética , Artéria Pulmonar/diagnóstico por imagem , Doenças Vasculares/diagnóstico por imagem , Malformações Vasculares/diagnóstico por imagem , Ecocardiografia , Humanos , Valor Preditivo dos Testes , Prognóstico , Artéria Pulmonar/anormalidades , Artéria Pulmonar/fisiopatologia , Circulação Pulmonar , Tomografia Computadorizada de Emissão , Doenças Vasculares/fisiopatologia , Malformações Vasculares/fisiopatologia
17.
Eur Radiol ; 27(10): 4188-4197, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27778090

RESUMO

OBJECTIVE: Despite 90 % of glioblastoma (GBM) recurrences occurring in the peritumoral brain zone (PBZ), its contribution in patient survival is poorly understood. The current study leverages computerized texture (i.e. radiomic) analysis to evaluate the efficacy of PBZ features from pre-operative MRI in predicting long- (>18 months) versus short-term (<7 months) survival in GBM. METHODS: Sixty-five patient examinations (29 short-term, 36 long-term) with gadolinium-contrast T1w, FLAIR and T2w sequences from the Cancer Imaging Archive were employed. An expert manually segmented each study as: enhancing lesion, PBZ and tumour necrosis. 402 radiomic features (capturing co-occurrence, grey-level dependence and directional gradients) were obtained for each region. Evaluation was performed using threefold cross-validation, such that a subset of studies was used to select the most predictive features, and the remaining subset was used to evaluate their efficacy in predicting survival. RESULTS: A subset of ten radiomic 'peritumoral' MRI features, suggestive of intensity heterogeneity and textural patterns, was found to be predictive of survival (p = 1.47 × 10-5) as compared to features from enhancing tumour, necrotic regions and known clinical factors. CONCLUSION: Our preliminary analysis suggests that radiomic features from the PBZ on routine pre-operative MRI may be predictive of long- versus short-term survival in GBM. KEY POINTS: • Radiomic features from peritumoral regions can capture glioblastoma heterogeneity to predict outcome. • Peritumoral radiomics along with clinical factors are highly predictive of glioblastoma outcome. • Identifying prognostic markers can assist in making personalized therapy decisions in glioblastoma.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Glioblastoma/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Encefálicas/mortalidade , Feminino , Glioblastoma/mortalidade , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/epidemiologia , Prognóstico , Reprodutibilidade dos Testes , Medição de Risco , Taxa de Sobrevida , Adulto Jovem
18.
Pediatr Radiol ; 47(6): 755-760, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28213627

RESUMO

Real-time MRI-guided percutaneous sclerotherapy is a novel and evolving treatment for congenital lymphatic malformations in the head and neck. We elaborate on the specific steps necessary to perform an MRI-guided percutaneous sclerotherapy of lymphatic malformations including pre-procedure patient work-up and preparation, stepwise intraprocedural interventional techniques and post-procedure management. Based on our institutional experience, MRI-guided sclerotherapy with a doxycycline-gadolinium-based mixture as a sclerosant for lymphatic malformations of the head and neck region in children is well tolerated and effective.


Assuntos
Anormalidades Linfáticas/terapia , Imagem por Ressonância Magnética Intervencionista , Soluções Esclerosantes/uso terapêutico , Escleroterapia/métodos , Adolescente , Criança , Meios de Contraste/uso terapêutico , Doxiciclina/uso terapêutico , Feminino , Cabeça , Humanos , Masculino , Pescoço , Resultado do Tratamento
19.
Vasa ; 46(2): 121-126, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28247824

RESUMO

BACKGROUND: The long term efficacy of endovascular recanalization for chronic iliocaval occlusion secondary to inferior vena cava (IVC) filters is unknown. The purpose of this study was to evaluate the effectiveness of endovascular recanalization and stent placement across the filter in patients with filter-associated chronic iliocaval occlusion. PATIENTS AND METHODS: Seven patients (mean age 56 ± 15 yrs; seven males) with symptomatic chronic iliocaval occlusion and occluded IVC filter were included. Immediate technical success rate, long term clinical effectiveness of endovascular recanalization and patency rate of the stents were assessed. RESULTS: In all patients, the endovascular treatment consisted of percutaneous venous access, recanalization of the occluded iliac veins and the IVC, transluminal angioplasty and stenting of the infrarenal inferior vena cava and iliac veins with self-expanding stents. The IVC filter was not removed, but rather the stents were extended across the filter. In four of seven patients (57 %), adjunctive pharmaco-mechanical thrombolysis was performed. All patients received anticoagulation post procedure. The mean clinical follow-up was 51.1 ± 27 months. Technical success rate was 100 %. Clinical success rate with symptomatic improvement was 85.7 %; one patient developed post-thrombotic syndrome on long term follow-up despite initial symptomatic improvement. Poststenting, the primary patency rate was 85.7 % (six of seven patients) and the secondary patency rate was 100 % (seven of seven patients). CONCLUSIONS: Endovascular recanalization with balloon angioplasty and placement of a self-expanding stent across a chronically occluded IVC filer can be performed safely and effectively for patients with symptomatic iliocaval thrombosis. An adjunctive pharmacologic-mechanical thrombolysis may be considered for selected patients.


Assuntos
Procedimentos Endovasculares , Filtros de Veia Cava/efeitos adversos , Veia Cava Inferior , Trombose Venosa/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença Crônica , Angiografia por Tomografia Computadorizada , Constrição Patológica , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Flebografia/métodos , Estudos Retrospectivos , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/fisiopatologia , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/etiologia , Trombose Venosa/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa