Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38302192

RESUMO

AIMS: In patients with atrial flutter (AFL), ablation of the cavotricuspid isthmus (CTI) is a highly effective procedure to prevent AFL recurrence, but atrial fibrillation (AF) may occur during follow-up. The presented FLUTFIB study was designed to identify the exact incidence, duration, timely occurrence, and associated symptoms of AF after CTI ablation using continuous cardiac monitoring via implantable loop recorders. METHODS AND RESULTS: One hundred patients with AFL without prior AF diagnosis were included after CTI ablation (mean age 69.7 ± 9.7 years, 18% female) and received an implantable loop recorder for AF detection. After a median follow-up of 24 months 77 patients (77%) were diagnosed with AF episodes. Median time to first AF occurrence was 180 (43-298) days. Episodes lasted longer than 1 h in most patients (45/77, 58%). Forty patients (52%) had AF-associated symptoms.Patients with and without AF development showed similar baseline characteristics and neither HATCH- nor CHA2DS2-VASc scores were predictive of future AF episodes. Oral anticoagulation (OAC) was stopped during FU in 32 patients (32%) and was re-initiated after AF detection in 15 patients (15%). No strokes or transient ischaemic attack episodes were observed during follow-up. CONCLUSION: This study represents the largest investigation using implantable loop recorders (ILRs) to detect AF after AFL ablation and shows a high incidence of AF episodes, most of them being asymptomatic and lasting longer than 1 h. In anticipation of trials determining the duration of AF episodes that should trigger OAC initiation, these results will help to guide anticoagulation management after CTI ablation.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico , Flutter Atrial/epidemiologia , Flutter Atrial/cirurgia , Incidência , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Anticoagulantes/uso terapêutico , Resultado do Tratamento
2.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38591838

RESUMO

AIMS: Recent trial data demonstrate beneficial effects of active rhythm management in patients with atrial fibrillation (AF) and support the concept that a low arrhythmia burden is associated with a low risk of AF-related complications. The aim of this document is to summarize the key outcomes of the 9th AFNET/EHRA Consensus Conference of the Atrial Fibrillation NETwork (AFNET) and the European Heart Rhythm Association (EHRA). METHODS AND RESULTS: Eighty-three international experts met in Münster for 2 days in September 2023. Key findings are as follows: (i) Active rhythm management should be part of the default initial treatment for all suitable patients with AF. (ii) Patients with device-detected AF have a low burden of AF and a low risk of stroke. Anticoagulation prevents some strokes and also increases major but non-lethal bleeding. (iii) More research is needed to improve stroke risk prediction in patients with AF, especially in those with a low AF burden. Biomolecules, genetics, and imaging can support this. (iv) The presence of AF should trigger systematic workup and comprehensive treatment of concomitant cardiovascular conditions. (v) Machine learning algorithms have been used to improve detection or likely development of AF. Cooperation between clinicians and data scientists is needed to leverage the potential of data science applications for patients with AF. CONCLUSIONS: Patients with AF and a low arrhythmia burden have a lower risk of stroke and other cardiovascular events than those with a high arrhythmia burden. Combining active rhythm control, anticoagulation, rate control, and therapy of concomitant cardiovascular conditions can improve the lives of patients with AF.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Risco , Hemorragia , Anticoagulantes/uso terapêutico
3.
Strahlenther Onkol ; 199(5): 511-519, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36750509

RESUMO

PURPOSE: Cardiac radioablation (cRA) using a stereotactic single-session radioablative approach has recently been described as a possible treatment option for patients with otherwise untreatable recurrent ventricular tachycardia (VT). There is very limited experience in cRA for patients undergoing left ventricular assist device (LVAD) therapy. We present clinical experiences of two patients treated with cRA for incessant VT under long-term LVAD therapy. METHODS: Two male patients (54 and 61 years old) with terminal heart failure under LVAD therapy (both patients for 8 years) showed incessant VT despite extensive antiarrhythmic drug therapy and repeated catheter ablation. cRA with a single dose of 25 Gy was applied as a last resort strategy under compassionate use in both patients following an electroanatomical mapping procedure. RESULTS: Both patients displayed ongoing VT during and after the cRA procedure. Repeated attempts at post-procedural rhythm conversion failed in both patients; however, one patient was hemodynamically stabilized and could be discharged home for several months before falling prey to a fatal bleeding complication. The second patient initially stabilized for a few days following cRA before renewed acceleration of running VT required bilateral ablation of the stellate ganglion; the patient died 50 days later. No immediate side effects of cRA were detected in either patient. CONCLUSION: cRA might serve as a last resort strategy for patients with terminal heart failure undergoing LVAD therapy and displaying incessant VT. Intermediate- and long-term outcomes of these seriously ill patients often remain poor; therefore, best supportive care strategies should also be evaluated as long as no clear beneficial effects of cRA procedures can be shown. For patients treated with cRA under running ventricular rhythm abnormality, strategies for post-procedural generation of stabilized rhythm have to be established.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Coração Auxiliar/efeitos adversos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
4.
Pacing Clin Electrophysiol ; 44(1): 93-100, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33140439

RESUMO

BACKGROUND: Implantable cardioverter defibrillators use low-voltage shock impedance measurements to monitor the lead integrity. However, previous case reports suggest that low-voltage shock impedance measurements may fail to detect insulation breaches that can cause life-threatening electrical short circuits. METHODS AND RESULTS: We report six cases of insulation breaches in transvenous defibrillation leads that were not obvious during standard interrogations and testing of the lead beforehand. In two cases, an electrical short circuit during commanded shock delivery for internal electrical cardioversion resulted in a total damage of the ICD generator. In one of these cases, commanded shock delivery induced ventricular fibrillation, which required external defibrillation. In two cases, a shock due to ventricular tachycardia was aborted as the shock impedance was less than 20 Ω. However, in both cases the tiny residual shock energy terminated the ventricular tachycardia. In contrast, in one case the residual energy of the aborted shock did not end ventricular fibrillation induced at defibrillator threshold testing. In one case, the ICD indicated an error code for a short circuit condition detected during an adequate shock delivery. CONCLUSIONS: This case series illustrates that low-voltage shock impedance measurements can fail to detect insulation breaches. These data suggest that in patients without a contraindication, traditional defibrillator threshold testing or high voltage synchronized shock at the time of device replacement should be considered.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Idoso , Idoso de 80 Anos ou mais , Impedância Elétrica , Eletrocardiografia , Análise de Falha de Equipamento , Humanos , Masculino , Pessoa de Meia-Idade
5.
Echocardiography ; 38(1): 147-148, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33280163

RESUMO

We report a 55-year-old male patient with lone paroxysmal atrial fibrillation who underwent routine transesophageal echocardiography (TOE) at our institution. In a mid-esophageal 125° three-chamber angulation, a distinct thinning of the left atrial (LA) wall was observed, forming a 7 × 4 mm canal with only a small membrane separating the LA from the pericardial space. Cardiac magnetic resonance imaging diagnosed a small LA diverticulum. To the best of our knowledge, this is the first manuscript describing detection of a small LA diverticulum via TOE.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Divertículo , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Divertículo/diagnóstico por imagem , Ecocardiografia Transesofagiana , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
6.
J Electrocardiol ; 66: 102-107, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33906056

RESUMO

BACKGROUND: Patients with COVID-19 seem to be prone to the development of arrhythmias. The objective of this trial was to determine the characteristics, clinical significance and therapeutic consequences of these arrhythmias in COVID-19 patients requiring intensive care unit (ICU) treatment. METHODS AND RESULTS: A total of 113 consecutive patients (mean age 64.1 ± 14.3 years, 30 (26.5%) female) with positive PCR testing for SARS-CoV2 as well as radiographically confirmed pulmonary involvement admitted to the ICU from March to May 2020 were included and observed for a cumulative time of 2321 days. Fifty episodes of sustained atrial tachycardias, five episodes of sustained ventricular arrhythmias and thirty bradycardic events were documented. Sustained new onset atrial arrhythmias were associated with hemodynamic deterioration in 13 cases (35.1%). Patients with new onset atrial arrhythmias were older, showed higher levels of Hs-Troponin and NT-proBNP, and a more severe course of disease. The 5 ventricular arrhythmias (two ventricular tachycardias, two episodes of ventricular fibrillation, and one torsade de pointes tachycardia) were observed in 4 patients. All episodes could be terminated by immediate defibrillation/cardioversion. Five bradycardic events were associated with hemodynamic deterioration. Precipitating factors could be identified in 19 of 30 episodes (63.3%), no patient required cardiac pacing. Baseline characteristics were not significantly different between patients with or without bradycardic events. CONCLUSION: Relevant arrhythmias are common in severely ill ICU patients with COVID-19. They are associated with worse courses of disease and require specific treatment. This makes daily close monitoring of telemetric data mandatory in this patient group.


Assuntos
COVID-19 , Idoso , Arritmias Cardíacas/diagnóstico , Eletrocardiografia , Feminino , Humanos , Unidades de Terapia Intensiva , Pessoa de Meia-Idade , RNA Viral , SARS-CoV-2
7.
J Cardiovasc Electrophysiol ; 31(6): 1527-1535, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32173957

RESUMO

INTRODUCTION: Catecholaminergic polymorphic ventricular tachycardia (CPVT) is an inherited arrhythmia syndrome characterized by adrenergically stimulated ventricular tachycardia. The most common form of CPVT is due to autosomal dominant variants in the cardiac ryanodine-receptor gene (RYR2). However, trans-2,3-enoyl-CoA reductase-like (TECRL) was recently suggested to be a novel candidate gene for life-threatening inherited arrhythmias. Patients previously reported with pathogenic changes in TECRL showed a special mixed phenotype of CPVT and long-QT-syndrome (LQTS) termed CPVT type 3 (CPVT3), an autosomal recessive disorder. METHODS AND RESULTS: We implemented TECRL into our NGS panel diagnostics for CPVT and LQTS in April 2017. By December 2018, 631 index patients with suspected CPVT or LQTS had been referred to our laboratory for genetic testing. Molecular analysis identified four Caucasian families carrying novel variants in TECRL. One patient was homozygous for Gln139* resulting in a premature stop codon and loss-of-function of the TECRL protein. Another patient was homozygous for Pro290His, probably leading to an altered folding of the 3-oxo-5-alpha steroid 4-dehydrogenase domain of the TECRL protein. The LOF-variant Ser309* and the missense-variant Val298Ala have been shown to be compound heterozygous in another individual. NGS-based copy number variation analysis and quantitative PCR revealed a quadruplication of TECRL in the last individual, which is likely to be a homozygous duplication. CONCLUSION: The data from our patient collective indicate that CPVT3 occurs much more frequently than previously expected. Variants in TECRL may be causative in up to 5% of all CPVT cases. According to these findings, the default analysis of this gene is recommended if CPVT is suspected.


Assuntos
Códon sem Sentido , Variações do Número de Cópias de DNA , Amplificação de Genes , Mutação com Perda de Função , Oxirredutases/genética , Taquicardia Ventricular/genética , Potenciais de Ação , Adolescente , Criança , Feminino , Predisposição Genética para Doença , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Hereditariedade , Heterozigoto , Homozigoto , Humanos , Masculino , Pessoa de Meia-Idade , Oxirredutases/metabolismo , Linhagem , Fenótipo , Dobramento de Proteína , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/enzimologia , Taquicardia Ventricular/fisiopatologia
8.
Pacing Clin Electrophysiol ; 43(3): 327-331, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32091133

RESUMO

INTRODUCTION: Radiofrequency (RF) ablation is a commonly used tool in the invasive electrophysiology laboratory to treat a variety of rhythm disorders. Reliable creation of transmural ablation lesions is crucial for long-term success. Lesion size index (LSI) is a multiparametric index that incorporates time, power, contact force (CF), and impedance data recorded during RF ablation in a weighted formula and has been shown to predict the extent of myocardial tissue lesions. Whether the force stability of contact influences lesion size in LSI-guided ablations is unknown. OBJECTIVES: The aim of this study was to analyze the influence of the force stability of contact on lesion size during LSI-guided ablations in an ex-vivo model. METHODS AND RESULTS: A total of 267 RF lesions (n = 6 hearts) were created on porcine myocardial slabs by using an open-tip irrigated ablation catheter with the following settings: 35 W with either intermittent (varied between 0 and up to 20 g), variable (10 to 20 g), or constant tissue contact (15 g) in a perpendicular or parallel fashion (applied manually) up to a target LSI of either 5 or 6. Subsequently, lesion width and depth were determined. Lesion width was mainly influenced by catheter tip orientation and LSI, whereas lesion depth was mainly influenced by LSI alone. The force stability of catheter contact had no relevant impact on lesion width or depth. CONCLUSION: The force stability of catheter contact has only little effect on lesion depth or width in LSI-guided catheter ablation while the catheter orientation primarily affects lesion width.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Ablação por Radiofrequência/métodos , Animais , Procedimentos Cirúrgicos Cardíacos/instrumentação , Técnicas In Vitro , Modelos Animais , Ablação por Radiofrequência/instrumentação , Suínos
9.
J Electrocardiol ; 63: 110-114, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33181453

RESUMO

BACKGROUND: Atrial and ventricular arrhythmias significantly contribute to morbidity and mortality of patients with cardiac disease. Ablation of these arrhythmias has shown to improve clinical outcomes, yet targeted ablation strategies rely on proper mapping capabilities. In the present study, we compare different modes of high-resolution mapping in clinically relevant arrhythmias using HD grid. METHODS AND RESULTS: Using the Advisor™ HD Grid Mapping Catheter in either the standard, the wave (bipolar along spline and bipolar orthogonal) or the wave diagonal setting, low-voltage areas were determined. Low-voltage was defined as local electrograms with an amplitude <0.5 mV (bipolar; atria/ventricle) or <4 mV (unipolar; ventricle). Ultra high-density mapping in 47 patients with ventricular tachycardia, ventricular premature beats, atrial fibrillation and atrial tachycardia provided reliable information for the understanding of the arrhythmia mechanism resulting in safe ablation procedures. Regions of low voltage were significantly decreased by 14 ± 2% and 31 ± 3% with wave and wave diagonal settings as compared to standard settings, respectively. CONCLUSION: Substrate mapping and risk stratification relies on proper low voltage discrimination. Even though the Advisor™ HD Grid Mapping Catheter was safely used in all cases, the extent of low voltage areas was mapping-mode dependent.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Catéteres , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Humanos , Taquicardia Ventricular/cirurgia
10.
Circulation ; 137(25): 2730-2740, 2018 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-29915100

RESUMO

BACKGROUND: Postmortem interrogations of cardiac implantable electronic devices (CIEDs), recommended at autopsy in suspected cases of sudden cardiac death, are rarely performed, and data on systematic postmortem CIED analysis in the forensic pathology are missing. The aim of the study was to determine whether nonselective postmortem CIED interrogations and data analysis are useful to the forensic pathologist to determine the cause, mechanism, and time of death and to detect potential CIED-related safety issues. METHODS: From February 2012 to April 2017, all autopsy subjects in the department of forensic medicine at the University Hospital Charité who had a CIED underwent device removal and interrogation. Over the study period, 5368 autopsies were performed. One hundred fifty subjects had in total 151 CIEDs, including 109 pacemakers, 35 defibrillators, and 7 implantable loop recorders. RESULTS: In 40 cases (26.7%) time of death and in 51 cases (34.0%) cause of death could not be determined by forensic autopsy. Of these, CIED interrogation facilitated the determination of time of death in 70.0% of the cases and clarified the cause of death in 60.8%. Device concerns were identified in 9 cases (6.0%), including 3 hardware, 4 programming, and 2 algorithm issues. One CIED was submitted to the manufacturer for a detailed technical analysis. CONCLUSIONS: Our data demonstrate the necessity of systematic postmortem CIED interrogation in forensic medicine to determine the cause and timing of death more accurately. In addition, CIED analysis is an important tool to detect potential CIED-related safety issues.


Assuntos
Autopsia/métodos , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis , Remoção de Dispositivo , Medicina Legal/métodos , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Fatores de Tempo
11.
J Electrocardiol ; 51(2): 170-174, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29174097

RESUMO

BACKGROUND: Propofol is commonly used for procedural sedation in interventional electrophysiology. However, ventricular arrhythmias under Propofol have been reported. Our aim was to investigate ventricular repolarization and incidence of ventricular arrhythmias under Propofol infusion in adults with cardiac arrhythmias. METHODS: QRS, QTcB (Bazett), QTcFri (Fridericia), JTc, measurement of T peak to Tend time (Tp-e) at baseline and under Propofol infusion was performed in 235 patients. Screening for unexpected ventricular arrhythmias was performed in 1165 patients undergoing EP procedures under Propofol. RESULTS: A significant prolongation of Tp-e under Propofol infusion (79.7±17.3 vs. 86.4±22.5ms, p<0.001) and of QTcFri (429.3±35.8 vs. 435.5±36.5, p=0.033) was detected. No significant change of the QTcB interval, JTc interval or QRS duration was observed. One case (0.09%) of ventricular fibrillation during rapid ventricular pacing under Propofol occurred. CONCLUSION: Although transmural dispersion of ventricular repolarisation is increased under Propofol, incidence of malignant ventricular arrhythmias is low. For evaluation of QT interval under Propofol, Fridericia's correction formula should be used rather than Bazett's formula.


Assuntos
Arritmias Cardíacas/induzido quimicamente , Arritmias Cardíacas/diagnóstico , Hipnóticos e Sedativos/efeitos adversos , Propofol/efeitos adversos , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
12.
Europace ; 19(8): 1293-1301, 2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27738066

RESUMO

AIMS: In persistent atrial fibrillation (AF), left atrial low-voltage areas and complex fractionated atrial electrograms (CFAEs) have been thoroughly discussed as critical substrate points for AF perpetuation. Thus, in patients undergoing pulmonary vein isolation, these sites are often considered additional ablation targets. Currently, mapping techniques for these substrate indicators are still under discussion. The aim of this study was to evaluate the impact of different mapping catheters on the detection of low-voltage areas and CFAE. METHODS AND RESULTS: Two bipolar voltage maps and two CFAE left atrial maps were obtained each in 30 patients undergoing catheter ablation of AF using the following two different catheters: A four-pole ablation catheter (MAP, mapping and ablation catheter) (electrode size: tip: 4 mm, band: 1 mm; inter-electrode spacing: 0.5-5-2 mm) and a 10-pole circular pulmonary vein mapping catheter (CMC) (electrode size: 1 mm; inter-electrode spacing: 7-7-7 mm). Successively, low-voltage and CFAE area sizes were then compared between the two catheters. Areas with a bipolar voltage of <0.5 mV were significantly smaller when obtained with the CMC compared with the MAP (8.9 ± 8.9 vs. 17.4 ± 11.7 cm², P < 0.001). This was also significantly different for a bipolar voltage of <0.2 mV (2.3 ± 4.6 vs. 6.2 ± 9.6 cm², P < 0.001). Complex fractionated atrial electrogram area sizes were significantly larger when obtained with the CMC compared with the MAP group (14.6 ± 10.9 vs. 19.4 ± 9.4 cm², P = 0.011). CONCLUSION: Low-voltage and CFAE area size varies significantly between different mapping catheters. Mapping electrode settings have to be taken into consideration for the assessment of electroanatomical substrate of AF.


Assuntos
Fibrilação Atrial/diagnóstico , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Desenho de Equipamento , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador
13.
Pacing Clin Electrophysiol ; 40(5): 585-590, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28240366

RESUMO

BACKGROUND: Patients' satisfaction with invasive procedures largely relies on periprocedural perception of pain and discomfort. The necessity for intraprocedural sedation during catheter ablation of cardiac arrhythmias for technical reasons is widely accepted, but data on patients' experience of pain and satisfaction with the procedural sedation are scarce. We have assessed patients' pain and discomfort during and after the procedure using a standardized questionnaire. METHODS: One hundred seventeen patients who underwent catheter ablation answered a standardized questionnaire on periprocedural perception of pain and discomfort after different anesthetic protocols with propofol/midazolam with and without additional piritramide and ketamine/midazolam. RESULTS: Patients report a high level of satisfaction with periprocedural sedation with 83% judging sedation as good or very good. The majority of patients was unconscious of the whole procedure and did not recollect experiencing pain. Procedural pain was reported by 7.7% of the patients and 16% reported adverse effects, e.g., postprocedural nausea and episodes of headache. CONCLUSION: The results of our study show that deep sedation during catheter ablation of cardiac arrhythmias is generally well tolerated and patients are satisfied with the procedure. Yet, a number of patients reports pain or adverse events. Therefore, studies comparing different sedation strategies should be conducted in order to optimize sedation and analgesia.


Assuntos
Arritmias Cardíacas/psicologia , Arritmias Cardíacas/cirurgia , Catastrofização/psicologia , Ablação por Cateter/psicologia , Sedação Profunda/psicologia , Dor Pós-Operatória/prevenção & controle , Dor Pós-Operatória/psicologia , Catastrofização/etiologia , Catastrofização/prevenção & controle , Ablação por Cateter/efeitos adversos , Sedação Profunda/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Dor Pós-Operatória/etiologia , Satisfação do Paciente , Resultado do Tratamento
14.
Pacing Clin Electrophysiol ; 40(12): 1380-1383, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29090490

RESUMO

BACKGROUND AND AIMS: Antiscatter grids improve image contrast by absorbing scattered x-ray beams, although by removing the antiscatter grid patient dose can be reduced as more x-ray beams reach the image receptor. Additionally, there is a trend toward ultra-low frame rates for radiation dose reduction during various electrophysiology procedures. As for most cardiac device implantations (CIED) image quality demands are usually modest, the purpose of this study was to assess the safety and efficacy of an ultra-low frame rate and scatter grid-less radiation protocol. METHODS/RESULTS: A total of 140 patients undergoing CIED implantation between 2014 and 2017 were included in the study. Seventy patients (50%) implanted after implementation of the antiscatter grid-less and ultra-low frame rate protocol were matched to controls before the dose-reduction protocol was established. Forty patients (28.6%) had a one-chamber pacemaker or one-chamber implantable cardioverter defibrillator (ICD) implantation/revision, 60 (42.9%) had a two-chamber pacemaker or two-chamber ICD implantation/revision, and 40 (28.6%) patients had a cardiac resynchronization therapy device implantation/revision. Removing the antiscatter-grid and lowering the frame rate led to a 73% reduction of the overall dose area product (1,206 ± 2,015 vs 324 ± 422 µGym, P < 0.001). Procedural duration (95 ± 51 minutes vs 82 ± 44 minutes, P  =  0.053) and rate of complications were not significantly different between the two groups. CONCLUSION: The use of an ultra-low frame rate and antiscatter grid-less radiation protocol significantly reduced radiation dose for implantation of CIED and led to very low average patient doses, while procedural duration and complication rates did not increase.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Implantação de Prótese/métodos , Doses de Radiação , Idoso , Protocolos Clínicos , Feminino , Humanos , Masculino , Estudos Retrospectivos , Espalhamento de Radiação , Cirurgia Assistida por Computador
15.
Pacing Clin Electrophysiol ; 40(7): 788-793, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28548234

RESUMO

BACKGROUND: A considerable amount of patients with typical atrial flutter develop atrial fibrillation after cavotricuspid isthmus (CTI) ablation. No uniform recommendations are available to guide anticoagulation regimes or electrocardiogram (ECG) monitoring strategies after this procedure. METHODS: We conducted a web-based survey in electrophysiology (EP) centers in Germany, Switzerland, and Austria. Responses were received from 47 centers. The survey was designed to investigate variations in management of the following: ablation strategy, oral anticoagulation (OAC) management, and ECG monitoring after successful CTI ablation. RESULTS: More than 55% of the participating centers assume that at least every third patient will develop atrial fibrillation during follow-up. Despite this assumption, most EP experts (81%) would still stop OAC after CTI ablation even in patients with higher CHADS2-VA2SC-score, or even perform CTI in asymptomatic patients with the purpose to stop OAC (52%). Most experts agree that ECG monitoring is necessary during follow-up. A majority still rely on short-term monitoring tools like resting ECGs (7%) or Holter ECGs (43%), while continuous monitoring by implantable loop recorders (10%) are rarely used for postablation OAC management. CONCLUSION: A majority of the centers stop OAC in patients with higher CHADS2-VA2SC-score after CTI ablation. There is evidence that this practice might not be safe and lead to an increased number of ischemic strokes during follow-up. This reflects the need for prospective studies to allow for clear guidelines regarding these issues.


Assuntos
Anticoagulantes/administração & dosagem , Fibrilação Atrial/etiologia , Flutter Atrial/fisiopatologia , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Eletrocardiografia , Padrões de Prática Médica/estatística & dados numéricos , Administração Oral , Áustria , Feminino , Alemanha , Humanos , Masculino , Veias Pulmonares/cirurgia , Inquéritos e Questionários , Suíça
16.
Pacing Clin Electrophysiol ; 40(5): 516-526, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28220938

RESUMO

BACKGROUND: Implantable loop recorders (ILR) are valuable tools for the investigation of patients with suspected arrhythmias. The BioMonitor 2-AF is a novel insertable ILR with enhanced atrial fibrillation (AF) detection algorithm and remote monitoring capability. OBJECTIVE: The objective of this first-in-human study with the BioMonitor 2-AF was to analyze course of P-wave sensing performance and R-wave amplitude, prevalence of false and correctly sensed and classified episodes, and effectiveness of remote monitoring. METHODS: All 19 patients who underwent ILR insertion were included in the BIOTRONIK Home Monitoring® system (BIOTRONIK GmbH, Berlin, Germany). Daily changes in P-wave and R-wave sensing were analyzed over 6 weeks. A breathing test (in- and expiration) was performed in two different body positions at baseline and during a 6-week in-house follow-up to investigate alterations of P-wave and R-wave sensing. RESULTS: R-wave amplitude and the high P-wave visibility (94.4%) remained unchanged during the follow-up period. In most patients both an increase and decrease of R-wave amplitude, and in some cases a complete R-wave vector change (31.6%), was documented during the "breathing test." Change of body position did not alter R-wave sensing amplitude mostly. "Breathing test" and change of body position had no effect on P-wave sensing performance. In 15.8% of the patients, misclassification of episodes as AF or high ventricular rates due to P-wave oversensing occurred. No ILR-related complication occurred. Automatic transmission via BIOTRONIK Home Monitoring® was successful 100% of the time. CONCLUSION: This study demonstrates that the BioMonitor 2-AF is a safe and effective tool for continuous cardiac monitoring.


Assuntos
Fibrilação Atrial/diagnóstico , Diagnóstico por Computador/instrumentação , Eletrocardiografia Ambulatorial/instrumentação , Eletrodos Implantados , Próteses e Implantes , Diagnóstico por Computador/métodos , Eletrocardiografia Ambulatorial/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Armazenamento e Recuperação da Informação/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Pacing Clin Electrophysiol ; 39(5): 452-7, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26926665

RESUMO

BACKGROUND: Left atrial ablation can be accompanied by discomfort or pain. The purpose of this study was to systematically compare pain reactions during ablation of atrial fibrillation under deep sedation with cryothermal and radiofrequency energy. METHODS AND RESULTS: Circumferential ablation was performed in patients with atrial fibrillation using either radiofrequency (RF) or cryoenergy. Deep sedation was achieved with a combination of propofol and midazolam. Pain reactions were counted and painful ablation sites located. To determine the severity of the pain reactions a Face, Legs, Activity, Cry, Consolability (FLACC) Behavioral Pain Assessment Scale was used: 79 patients (53 RF- vs 26 Cryoablations) were included. A total of 92% of patients treated with RF energy showed ≥1 pain reaction during the procedure compared to only 13% in the cryoenergy group (<0.001). The total number of pain reactions was significantly higher in the RF energy group (3.6 ± 4.7 vs1.3 ± 0.6, P = 0.005). Determination of painful sites was performed in the RF group only. Pain reactions were significantly more often observed during RF application left superior pulmonary vein (LSPV) ostium compared to other left atrial ablation sites (Total FLACC Score 2.8 ± 0.6 LSPV, 1.4 ± 0.4 left inferior pulmonary vein [P = 0.009], 1.4 ± 0.3 right superior pulmonary vein [P = 0.044], 1.1 ± 0.3 right inferior pulmonary vein [P = 0.032]). CONCLUSIONS: Our results show that despite deep sedation pain reactions often occur during RF ablation. Knowledge of areas with more frequent pain reactions may help electrophysiologists to reduce pain reactions and related patient movements. Ablation with cryoenergy was significantly less painful compared to ablation with RF energy. Cryoablation therefore may be considered for patients at a higher risk for anesthesia-related complications.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Sedação Profunda , Complicações Intraoperatórias/etiologia , Dor/etiologia , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Criocirurgia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
18.
Heart Vessels ; 31(9): 1544-52, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26498938

RESUMO

Catheter tissue contact force (CF) is an important factor for durable lesion formation during radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF). Since CF varies in the beating heart, atrial rhythm during RFCA may influence CF. A high-density map and RFCA points were obtained in 25 patients undergoing RFCA of AF using a CF-sensing catheter (Tacticath, St. Jude Medical). The operators were blinded to the CF information. Contact type was classified into three categories: constant, variable, and intermittent contact. Average CF and contact type were analyzed according to atrial rhythm (SR vs. AF) and anatomical location. A total of 1364 points (891 points during SR and 473 points during AF) were analyzed. Average CFs showed no significant difference between SR (17.2 ± 11.3 g) and AF (17.2 ± 13.3 g; p = 0.99). The distribution of points with an average CF of ≥20 and <10 g also showed no significant difference. However, the distribution of excessive CF (CF ≥40 g) was significantly higher during AF (7.4 %) in comparison with SR (4.2 %; p < 0.05). At the anterior area of the right inferior pulmonary vein (RIPV), the average CF during AF was significantly higher than during SR (p < 0.05). Constant contact was significantly higher during AF (32.2 %) when compared to SR (9.9 %; p < 0.01). Although the average CF was not different between atrial rhythms, constant contact was more often achievable during AF than it was during SR. However, excessive CF also seems to occur more frequently during AF especially at the anterior part of RIPV.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Frequência Cardíaca , Veias Pulmonares/cirurgia , Transdutores de Pressão , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Resultado do Tratamento
19.
Ann Noninvasive Electrocardiol ; 21(3): 319-324, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26701418

RESUMO

BACKGROUND: Implantable loop recorders (ILRs) allow continuous cardiac monitoring for 3-6 years and are a valuable tool for the investigation of syncopal episodes, palpitations, and atrial fibrillations as well as risk stratification after myocardial infarction. Although magnetic resonance imaging (MRI) in patients with ILRs has been shown to be safe, the impact of ILRs on cardiac MRI image quality has not been investigated yet. Thus, we tested the diagnostic value of cardiac MRI in patients with various types of ILRs. METHODS: Two patients with an ILR and a clinical indication to assess myocardial burden of scarring and fibrosis or stress-induced myocardial ischemia underwent cardiac MRI. Device interrogation was performed prior to, immediately after, and 3 months after cardiac MRI. RESULTS: The post-MRI follow-ups revealed no change in programmed ILR parameters, sensing fidelity, and battery parameters. However, ILRs caused significant, uninterpretable hyperintensity artifacts in cardiac MRI. CONCLUSIONS: Further clinical studies are warranted to investigate whether modified MRI techniques are helpful to eliminate imaging artifacts.

20.
Echocardiography ; 33(5): 724-33, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26857344

RESUMO

BACKGROUND: The purpose of this meta-analysis was to analyze the clinical relevance of left atrial (LA) strain to predict recurrence of atrial fibrillation (AF) after catheter ablation (CA). METHODS AND RESULTS: We searched in different databases (Medline, EMBASE, and Cochrane) prospective studies that analyzed LA strain before CA. Eight studies (2 with only paroxysmal AF and 6 with mixed population of paroxysmal and persistent AF) were included in the final analysis (total patient number = 686). Patients with recurrence of AF were principally characterized by lower LA strain in comparison with those without AF recurrence (mean 18.4% [range 8.8-24.5%] versus 25.3% [13.6-32.7%], weighted mean difference -4.89% [95% CI -5.83% to -3.95%], P < 0.001). In addition, receiver operating curves shown that LA strain was strongly associated with recurrence of AF after CA (weighted mean: AUC 0.798 [95% CI 0.700-0.943], cutoff 22.8% [18.8-30%], sensitivity 78% [65-86%], and specificity 75% [66-100%]). In line, these results were similar using LA strain with QRS-analysis and P-analysis as well as using different software package such as Echo-Pac, QLab, TomTec, and VVI. CONCLUSION: In patients with AF candidate for CA, the analysis of the LA using LA strain could be of great usefulness to identify patients with high risk of AF recurrence. Nonetheless, further studies are needed to establish the clinical relevance of LA strain in patients with persistent AF.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/estatística & dados numéricos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Fibrilação Atrial/epidemiologia , Progressão da Doença , Módulo de Elasticidade , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde/métodos , Prognóstico , Recidiva , Reprodutibilidade dos Testes , Medição de Risco/métodos , Sensibilidade e Especificidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa