Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-39413267

RESUMO

Failure to close the side branches of the internal mammary artery can result in ischemia due to coronary steal through a patent mammary artery side branch after coronary artery bypass grafting. The authors present the case of a 56-year-old man with recurrent angina after 6 month surgical myocardial revascularization underwent coronary angiography that showed patent left branch of the internal mammary artery. After demonstration of inducible ischemia, effective percutaneous treatment was performed using coil embolization, improving blood flow and clinical symptoms.

2.
Medicina (Kaunas) ; 60(1)2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38256388

RESUMO

Background and Objectives: Several studies revealed a relation between abnormal cardiac remodeling and glomerular filtration rate (GFR) decline, but there are limited data regarding echocardiographic changes in chronic kidney disease (CKD). This study evaluated the abnormal cardiac structures characterizing patients with CKD, assessing the independent association between echocardiographic parameters and the risk of decline in renal function. Materials and Methods: In total, 160 patients with CKD were studied. All patients underwent an echocardiographic exam and 99mTc-DTPA renal scintigraphy to measure the GFR. After the baseline assessments, patients were followed prospectively for 12 months, or until the endpoint achievement, defined as a worsening in renal function (doubling of baseline serum creatinine, GFR decline ≥25%, the start of dialysis). Results: Patients with GFR values of 34.8 ± 15 mL/min, identifying stages III-IV of CKD, were associated with high levels of left ventricular mass index (LVMi) (101.9 ± 12.2 g/m2), which was related to proteinuria, systolic blood pressure, and pulmonary artery systolic pressure in a multiple regression model. During the observational period, 26% of patients reached the endpoint. Regression analysis revealed LVMi as a predictor of change in renal function after adjusting for kidney and cardiac risk factors. Multiple Cox regression indicated that an increase in LVMi was associated with a 12% increased risk of kidney disease progression (HR: 1.12; 95% CI: 1.04-1.16; p = 0.001). Conclusions: In patients with CKD, high LVMi represents an independent predictor of the progressive decline of the renal function, until the start of renal replacement therapy. Echocardiography can help identify patients at high risk for renal disease worsening in patients with CKD independently of clinical cardiac involvement.


Assuntos
Diálise Renal , Insuficiência Renal Crônica , Humanos , Ecocardiografia , Taxa de Filtração Glomerular , Rim/diagnóstico por imagem , Insuficiência Renal Crônica/complicações
3.
Medicina (Kaunas) ; 59(7)2023 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-37512033

RESUMO

Background and Objectives: Minimally invasive cardiac surgery (MICS) has been developing since 1996. Peripheral cannulation is required to perform MICS, and good venous drainage and a bloodless field are crucial for the success of this procedure. We assessed the benefits of using a virtually wall-less cannula in comparison with the standard thin-wall cannula in clinical practice. Materials and Methods: Between January 2021 and December 2022, we evaluated 65 elective patients, who underwent isolated minimally invasive mitral valve surgery. Both the virtually wall-less and the thin-wall cannulas were placed through a surgical cut-down. Patients' characteristics at baseline were similar in the two groups, except for the body surface area (BSA), which was greater in the virtually wall-less group compared to the thin-wall one. In the standard group, the size of the cannula was chosen depending on the patient's BSA, and the choice of the Smartcannula was based on their height. Results: There were no significant differences between the two groups in terms of negative pressure applied, target flow achieved, hemolysis, the need for blood transfusion, and the post-operative increases in liver and renal enzymes. However, in all the patients, the estimated target flow was achieved, thereby showing the better hemodynamic performance of the virtually wall-less cannula, since, in this group, the patients' BSA was significantly greater compared to the thin-wall group. Ultimately, the mean cross-clamp time, as an indirect index of the effectiveness of the venous drainage, is shorter in the virtually wall-less group compared with the thin-wall group. Conclusions: The virtually wall-less cannula should be preferred in minimally invasive mitral valve surgery due to its superior performance in terms of venous drainage compared with the standard thin-wall cannula.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Valva Mitral , Humanos , Valva Mitral/cirurgia , Cânula , Cateterismo/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos
4.
J Card Surg ; 37(1): 165-173, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34717007

RESUMO

OBJECTIVE: To analyze Italian Cardiac Surgery experience during the pandemic of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) identifying risk factors for overall mortality according to coronavirus disease 2019 (COVID-19) status. METHODS: From February 20 to May 31, 2020, 1354 consecutive adult patients underwent cardiac surgery at 22 Italian Centers; 589 (43.5%), patients came from the red zone. Based on COVID-19 status, 1306 (96.5%) were negative to SARS-CoV-2 (COVID-N), and 48 (3.5%) were positive to SARS-CoV-2 (COVID-P); among the COVID-P 11 (22.9%) and 37 (77.1%) become positive, before and after surgery, respectively. Surgical procedures were as follows: 396 (29.2%) isolated coronary artery bypass grafting (CABG), 714 (52.7%) isolated non-CABG procedures, 207 (15.3%) two associate procedures, and three or more procedures in 37 (2.7%). Heart failure was significantly predominant in group COVID-N (10.4% vs. 2.5%, p = .01). RESULTS: Overall in-hospital mortality was 1.6% (22 cases), being significantly higher in COVID-P group (10 cases, 20.8% vs. 12, 0.9%, p < .001). Multivariable analysis identified COVID-P condition as a predictor of in-hospital mortality together with emergency status. In the COVID-P subgroup, the multivariable analysis identified increasing age and low oxygen saturation at admission as risk factors for in-hospital mortality. CONCLUSION: As expected, SARS-CoV-2 infection, either before or soon after cardiac surgery significantly increases in-hospital mortality. Moreover, among COVID-19-positive patients, older age and poor oxygenation upon admission seem to be associated with worse outcomes.


Assuntos
COVID-19 , SARS-CoV-2 , Adulto , Idoso , Ponte de Artéria Coronária , Humanos , Prognóstico
5.
PLoS Pathog ; 15(3): e1007684, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30883606

RESUMO

Phagocytosis is a complex process that eliminates microbes and is performed by specialised cells such as macrophages. Toll-like receptor 4 (TLR4) is expressed on the surface of macrophages and recognizes Gram-negative bacteria. Moreover, TLR4 has been suggested to play a role in the phagocytosis of Gram-negative bacteria, but the mechanisms remain unclear. Here we have used primary human macrophages and engineered THP-1 monocytes to show that the TLR4 sorting adapter, TRAM, is instrumental for phagocytosis of Escherichia coli as well as Staphylococcus aureus. We find that TRAM forms a complex with Rab11 family interacting protein 2 (FIP2) that is recruited to the phagocytic cups of E. coli. This promotes activation of the actin-regulatory GTPases Rac1 and Cdc42. Our results show that FIP2 guided TRAM recruitment orchestrates actin remodelling and IRF3 activation, two events that are both required for phagocytosis of Gram-negative bacteria.


Assuntos
Proteínas Adaptadoras de Transdução de Sinal/fisiologia , Proteínas de Transporte/metabolismo , Proteínas de Membrana/metabolismo , Fagocitose/fisiologia , Proteínas Adaptadoras de Transdução de Sinal/metabolismo , Animais , Proteínas de Transporte/fisiologia , Endocitose , Endossomos , Escherichia coli/patogenicidade , Células HEK293 , Humanos , Fator Regulador 3 de Interferon , Lipopolissacarídeos , Macrófagos/imunologia , Macrófagos/metabolismo , Proteínas de Membrana/fisiologia , Camundongos , Camundongos Endogâmicos C57BL , Fator 88 de Diferenciação Mieloide , Cultura Primária de Células , Transporte Proteico , Transdução de Sinais , Staphylococcus aureus/patogenicidade , Células THP-1 , Receptor 4 Toll-Like/metabolismo , Proteína cdc42 de Ligação ao GTP , Proteínas rab de Ligação ao GTP , Proteínas rac1 de Ligação ao GTP
6.
J Clin Ultrasound ; 49(2): 167-169, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32333791

RESUMO

Anomalous origin of the right coronary artery (RCA) from the left sinus of Valsalva is a rare but clinically relevant congenital anomaly, since the RCA may be subjected to cyclical compression due to its interarterial course. At least in the past, most patients experienced bad outcomes before being diagnosed with a malignant variant. Chronic (often subclinical) myocardial ischemia and possible arrhythmias are common complications. Once symptoms or electrocardiographic signs of myocardial ischemia become apparent, a quick diagnosis is mandatory. We report the case of a late symptomatic woman in whom RCA originated from the opposite sinus of Valsalva. The malignant variant was confirmed at transesophageal echocardiography directly in the catheterization laboratory, soon after angiographic diagnosis of aberrant origin.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Ecocardiografia Transesofagiana , Laboratórios , Seio Aórtico/diagnóstico por imagem , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Masculino , Isquemia Miocárdica/complicações
7.
J Clin Ultrasound ; 49(7): 690-692, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33634879

RESUMO

We report the case of massive hydatic heart disease in a 50-year-old male patient referred to hospital for recent-onset dyspnea, atypical chest, and hypotension. Right ventricular outflow tract obstruction was demonstrated to be caused by hypoechogenic formations at Doppler-echocardiography and confirmed to be hydatic cysts at cardiac magnetic resonance. These cysts developed within the right ventricular wall and the septum, and caused hemodynamic instability.


Assuntos
Cistos , Cardiopatias Congênitas , Obstrução do Fluxo Ventricular Externo , Ecocardiografia Doppler , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia
8.
Infect Immun ; 82(12): 5013-22, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25225249

RESUMO

Murine Toll-like receptor 13 (TLR13), an endosomal receptor that is not present in humans, is activated by an unmethylated motif present in the large ribosomal subunit of bacterial RNA (23S rRNA). Little is known, however, of the impact of TLR13 on antibacterial host defenses. Here we examined the role of this receptor in the context of infection induced by the model pathogen group B streptococcus (GBS). To this end, we used bacterial strains masked from TLR13 recognition by virtue of constitutive expression of the ErmC methyltransferase, which results in dimethylation of the 23S rRNA motif at a critical adenine residue. We found that TLR13-mediated rRNA recognition was required for optimal induction of tumor necrosis factor alpha and nitrous oxide in dendritic cell and macrophage cultures stimulated with heat-killed bacteria or purified bacterial RNA. However, TLR13-dependent recognition was redundant when live bacteria were used as a stimulus. Moreover, masking bacterial rRNA from TLR13 recognition did not increase the ability of GBS to avoid host defenses and replicate in vivo. In contrast, increased susceptibility to infection was observed under conditions in which signaling by all endosomal TLRs was abolished, i.e., in mice with a loss-of-function mutation in the chaperone protein UNC93B1. Our data lend support to the conclusion that TLR13 participates in GBS recognition, although blockade of the function of this receptor can be compensated for by other endosomal TLRs. Lack of selective pressure by bacterial infections might explain the evolutionary loss of TLR13 in humans. However, further studies using different bacterial species are needed to prove this hypothesis.


Assuntos
Imunidade Inata , Streptococcus agalactiae/imunologia , Receptores Toll-Like/imunologia , Animais , Células Cultivadas , Análise por Conglomerados , DNA Bacteriano/química , DNA Bacteriano/genética , DNA Ribossômico/química , DNA Ribossômico/genética , Células Dendríticas , Macrófagos/imunologia , Camundongos Endogâmicos C57BL , Dados de Sequência Molecular , Filogenia , RNA Ribossômico 23S/imunologia , Análise de Sequência de DNA
10.
Eur Heart J Case Rep ; 8(9): ytae457, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39420959

RESUMO

Background: The sudden onset of heart failure in high-risk transcatheter aortic valve implantation (TAVI) candidates poses significant challenges, necessitating meticulous planning and consideration of mechanical circulatory support options. Nevertheless, existing data on the efficacy and safety of mechanical circulatory support in this context are limited, along with criteria for patient selection. Case summary: An 87-year-old patient, with severe low-flow low-gradient aortic stenosis, presented with acute heart failure and concurrent COVID-19 pneumonia. Despite initial conservative management, her clinical condition deteriorated, requiring inotropic support. The decision was made to perform a rescue TAVI procedure with veno-arterial extracorporeal membrane oxygenation (ECMO) support. The patient underwent successful TAVI while managing complications, including cardiac arrest, with haemodynamic support from veno-arterial ECMO. Post-procedure, the patient showed improved cardiac function and was discharged in stable condition. Discussion: This case underscores the significance of strategic patient selection, proactive haemodynamic management, and the judicious use of veno-arterial ECMO in high-risk TAVI, particularly in complex scenarios involving acute heart failure and respiratory insufficiency, exacerbated by COVID-19. It highlights the challenges and critical decision points in TAVI planning, emphasizing the need for further research and standardized guidelines to refine indications for prophylactic mechanical circulatory support in TAVI procedures.

11.
J Clin Med ; 13(10)2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38792474

RESUMO

Background: Surgical aortic valve replacement (SAVR) is often complicated by acute kidney injury (AKI). Identifying patients at risk of AKI is important to start nephroprotective strategies or renal replacement therapy (RRT). This study investigated the incidence and risk factors of post-operative AKI in SAVR patients. Chronic kidney disease (CKD) developed in the post-cardiac-surgery follow-up period was also assessed. Methods: A total of 462 SAVR patients were retrospectively enrolled. The primary endpoint was the occurrence rate of AKI after surgery. Kidney recovery, during two planned outpatient clinic nephrological visits within 12 months after the surgery, was assessed. Results: A total of 76 patients experienced an AKI event. A Kaplan-Meier analysis revealed that subjects with CKD stage IV had a time to progression of 2.7 days, compared to patients with stages I-II, who were characterized by the slowest progression time, >11.2 days. A Cox regression indicated that CKD stages predicted a higher risk of AKI independently of other variables. During their ICU stay, 23 patients died, representing 5% of the population, most of them requiring RRT during their ICU stay. A severe CKD before the surgery was closely related to perioperative mortality. During the follow-up period, 21 patients with AKI worsened their CKD stage. Conclusions: AKI represents a common complication for SAVR patients in the early post-operative period, prolonging their ICU stay, with negative effects on survival, especially if RRT was required. Pre-operative CKD >3 stage is an independent risk factor for AKI in patients undergoing SAVR.

12.
J Clin Med ; 13(15)2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39124736

RESUMO

Background: The transfemoral (TF) approach is the most common route in TAVI, but it is still associated with a risk of bleeding and vascular complications. The aim of this study was to compare the clinical outcomes between surgical cut-down (SC) and percutaneous (PC) approach. (2) Methods: Between January 2018 and June 2022, 774 patients underwent a transfemoral TAVI procedure. After propensity matching, 323 patients underwent TAVI in each group. (3) Results: In the matched population, 15 patients (4.6%) in the SC group vs. 34 patients in the PC group (11%) experienced minor vascular complications (p = 0.02), while no difference for major vascular complication (1.5% vs. 1.9%) were reported. The rate of minor bleeding events was higher in the percutaneous group (11% vs. 3.1%, p <.001). The SC group experienced a higher rate of non-vascular-related access complications (minor 8% vs. 1.2%; major 2.2% vs. 1.2%; p < 0.001). (4) Conclusions: SC for TF-TAVI did not alter the mortality rate at 30 days and was associated with reduced minor vascular complication and bleeding. PC showed a lower rate of non-vascular-related access complications and a lower length of stay. The specific approach should be tailored to the patient's clinical characteristics.

13.
J Clin Med ; 13(13)2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38999202

RESUMO

Transcatheter aortic valve implantation (TAVI) now represents the mainstay of treatment for severe aortic stenosis. Owing to its exceptional procedural efficacy and safety, TAVI has been extended to include patients at lower surgical risk, thus now encompassing a diverse patient population receiving this treatment. Yet, long-term outcomes also depend on optimal medical therapy for secondary vascular prevention, with antithrombotic therapy serving as the cornerstone. Leveraging data from multiple randomized controlled trials, the current guidelines generally recommend single antithrombotic therapy, with either single antiplatelet therapy (SAPT) or oral anticoagulation (OAC) alone in those patients without or with atrial fibrillation, respectively. Yet, individualization of this pattern, as well as specific case uses, may be needed based on individual patient characteristics and concurrent procedures. This review aims to discuss the evidence supporting antithrombotic treatments in patients treated with TAVI, indications for a standardized treatment, as well as specific considerations for an individualized approach to treatment.

14.
J Clin Med ; 13(19)2024 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-39408046

RESUMO

Background: Balloon aortic valvuloplasty (BAV) is currently used as pre-treatment for patients undergoing trans-catheter aortic valve replacement (TAVR) as well as a stand-alone option for subjects with significant contraindications to TAVR. Mammoth is a newly available non-compliant balloon catheter (BC) included in the balloon-expandable Myval THV system (Meril Life Sciences Pvt. Ltd., India). As limited data on the performance of this BC are available, we here report the results following its use for BAV as pre-dilatation during TAVR or as a stand-alone procedure. Methods: A retrospective, single-center cohort analysis was performed on patients with severe aortic valve stenosis (AS) treated with the Mammoth BC at IRCCS Ospedale Galeazzi Sant'Ambrogio, Milan, Italy. The primary endpoint was technical success defined as successful Mammoth BC advancement across the AS followed by its full and homogeneous inflation without major complications such as aortic root/left ventricular outflow tract injury and/or stroke. Results: A total of 121 patients were treated by BAV with Mammoth BC during the study period. Among these, 105 patients underwent BAV pre-dilatation before TAVR while 16 patients underwent a stand-alone BAV procedure. Mammoth BC was delivered and successfully inflated at the target site in all of the 121 cases without BC-related complications (100% technical success). However, in the BAV "stand-alone group", three patients required two different balloon sizes while in nine patients multiple rounds (two to three) of balloon inflation were needed to significantly lower the transvalvular gradient. No cases of aortic root injury or massive aortic regurgitation due to Mammoth BC-related aortic leaflet injury were reported while one major stroke occurred late after TAVR. No intra-procedural deaths occurred nor bleeding (BARC 3-4) or major vascular complication. Conclusions: Mammoth BC use in patients with severe AS proved safe and effective, either before TAVR or as a stand-alone procedure, expanding the range of available tools for structural operators.

15.
J Clin Med ; 13(12)2024 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-38930050

RESUMO

Background: The optimal timing to perform percutaneous coronary interventions (PCIs) in patients undergoing transcatheter aortic valve replacement (TAVR) is not well established. In this meta-analysis, we aimed to compare the outcomes of patients undergoing PCI before versus after TAVR. Methods: A comprehensive literature search was performed including Medline, Embase, and Cochrane electronic databases up to 5 April 2024 for studies that compared PCI before and after TAVR reporting at least one clinical outcome of interest (PROSPERO ID: CRD42023470417). The analyzed outcomes were mortality, stroke, and myocardial infarction (MI) at follow-up. Results: A total of 3 studies involving 1531 patients (pre-TAVR PCI n = 1240; post-TAVR PCI n = 291) were included in this meta-analysis following our inclusion criteria. Mortality was higher in the pre-TAVR PCI group (OR: 2.48; 95% CI: 1.19-5.20; p = 0.02). No differences were found between PCI before and after TAVR for the risk of stroke (OR: 3.58; 95% CI: 0.70-18.15; p = 0.12) and MI (OR: 0.66; 95% CI: 0.30-1.42; p = 0.29). Conclusions: This meta-analysis showed in patients with stable CAD undergoing TAVR that PCI after TAVR is associated with lower mortality compared with PCI before TAVR.

19.
J Clin Med ; 12(16)2023 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-37629236

RESUMO

BACKGROUND: Identifying a panel of markers detecting kidney injury before the glomerular filtration rate reduction is a challenge to improving the diagnosis and management of acute kidney injury (AKI) in septic patients. This study evaluated the roles of tissue inhibitor metal proteinase-2, insulin growth factor binding protein-7 (TIMP2*IGFBP7), and mid-regional pro-adrenomedullin (MR-proADM) in patients with AKI. PATIENTS AND METHODS: This study was prospectively conducted in an intensive care unit (ICU) enrolling 230 patients who underwent cardiac surgery. Biomarkers were evaluated before and after 4 h of the cardiac surgery. RESULTS: Whereas urine and creatinine alterations appeared at 23.2 (12.7-36.5) hours after cardiac surgery, urinary TIMP2*IGBP7 levels were higher at 4 h in AKI patients (1.1 ± 0.4 mg/L vs. 0.08 ± 0.02 mg/L; p < 0.001). Its concentration > 2 mg/L increases AKI risk within the following 24 h, clearly identifying the population at high risk of renal replacement therapy (RRT). In patients with sepsis, MR-proADM levels were 2.3 nmol/L (0.7-7.8 nmol/L), with the highest values observed in septic shock patients (5.6 nmol/L (3.2-18 nmol/L)) and a better diagnostic profile than procalcitonin and C-reactive protein to identify septic patients. MR-proADM values > 5.1 nmol/L and urine TIMP2*IGBP7 levels > 2 mg/L showed a significantly faster progression to RRT, with a mean follow-up time of 1.1 days. CONCLUSIONS: TIMP2*IGBP7 and MR-proADM precociously diagnose AKI in septic patients after cardiac surgery, giving prognostic information for RRT requirement.

20.
J Cardiovasc Echogr ; 33(1): 40-42, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37426718

RESUMO

A 76-year-old man with history of previous coronary artery bypass grafting, permanent atrial fibrillation in novel oral anticoagulation therapy, and gastrointestinal bleedings underwent percutaneous left atrial appendage closure. The procedure was complicated by intraoperative device embolization, which caused a dynamic obstruction of the left ventricular outflow tract leading to severe hemodynamic instability. Transesophageal echocardiography showed a device in the ventricle site of the mitral anterior leaflet. The coronary angiography showed also patency of both arterial grafts in stable coronary artery disease. After failing the percutaneous retrieval with a snare, emergent surgery was planned. A moderate calcified aortic valve stenosis was also found, but in consideration of the unstable clinical conditions of the patient, we thought of performing a transcatheter aortic valve replacement (TAVR) in a second time. We have carefully planned the surgical retrieval of the device embolized paying attention of his several comorbidities. The strategy to remove the device with cardiopulmonary bypass without cross-clamping the aorta through a right mini-thoracotomy has been preferred.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa