Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Int J Mol Sci ; 24(19)2023 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-37833866

RESUMO

The infection of implanted biomaterial scaffolds presents a major challenge. Existing therapeutic solutions, such as antibiotic treatment and silver nanoparticle-containing scaffolds are becoming increasingly impractical because of the growth of antibiotic resistance and the toxicity of silver nanoparticles. We present here a novel concept to overcome these limitations, an electrospun polycaprolactone (PCL) scaffold functionalised with zinc oxide nanowires (ZnO NWs). This study assessed the antibacterial capabilities and biocompatibility of PCL/ZnO scaffolds. The fabricated scaffolds were characterised by SEM and EDX, which showed that the ZnO NWs were successfully incorporated and distributed in the electrospun PCL scaffolds. The antibacterial properties were investigated by co-culturing PCL/ZnO scaffolds with Staphylococcus aureus. Bacterial colonisation was reduced to 51.3% compared to a PCL-only scaffold. The biocompatibility of the PCL/ZnO scaffolds was assessed by culturing them with HaCaT cells. The PCL scaffolds exhibited no changes in cell metabolic activity with the addition of the ZnO nanowires. The antibacterial and biocompatibility properties make PCL/ZnO a good choice for implanted scaffolds, and this work lays a foundation for ZnO NWs-infused PCL scaffolds in the potential clinical application of tissue engineering.


Assuntos
Nanopartículas Metálicas , Nanofios , Óxido de Zinco , Alicerces Teciduais , Óxido de Zinco/farmacologia , Prata , Engenharia Tecidual , Antibacterianos/farmacologia , Poliésteres
2.
Bioengineering (Basel) ; 9(4)2022 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-35447723

RESUMO

Healthcare applications are known to have a considerable environmental impact and the use of bio-based polymers has emerged as a powerful approach to reduce the carbon footprint in the sector. This research aims to explore the suitability of using a new sustainable polyester blend (Floreon™) as a scaffold directed to aid in musculoskeletal applications. Musculoskeletal problems arise from a wide range of diseases and injuries related to bones and joints. Specifically, bone injuries may result from trauma, cancer, or long-term infections and they are currently considered a major global problem in both developed and developing countries. In this work we have manufactured a series of 3D-printed constructs from a novel biopolymer blend using fused deposition modelling (FDM), and we have modified these materials using a bioceramic (wollastonite, 15% w/w). We have evaluated their performance in vitro using human dermal fibroblasts and rat mesenchymal stromal cells. The new sustainable blend is biocompatible, showing no differences in cell metabolic activity when compared to PLA controls for periods 1-18 days. FloreonTM blend has proven to be a promising material to be used in bone tissue regeneration as it shows an impact strength in the same range of that shown by native bone (just under 10 kJ/m2) and supports an improvement in osteogenic activity when modified with wollastonite.

3.
ACS Appl Bio Mater ; 4(7): 5638-5649, 2021 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-35006734

RESUMO

Corneal blindness is the fourth most common cause of vision impairment worldwide with a high incidence in global south countries. A recently developed surgical technique for treating corneal blindness is simple limbal epithelial transplantation (SLET), which uses small pieces of healthy limbal tissue (limbal explants) delivered to the damaged eye using the human amniotic membrane (AM) as a carrier. SLET relies on the use of tissue banks for the AM that reduces the availability of the technique. Replacing the AM with a synthetic membrane is key to making SLET more accessible to those who need it. Previous research has demonstrated the suitability of electrospun poly(lactide-co-glycolide) (PLGA) scaffolds as AM substitutes, and here, we report how these membranes can be tailored to mimic fundamental AM mechanical properties. To modify the stiffness of PLGA electrospun membranes, we explored different electrospinning solvent systems (1,1,1,3,3,3,-hexafluoroisopropanol (HFIP), dichloromethane (DCM), chloroform, and N,N-dimethylformamide (DMF)) and the use of plasticizers (PEG400 and glycerol). PEG400 was found to reduce stiffness from 60 MPa to around 4 MPa, approaching the values shown by the native AM. The biocompatibility of membranes with and without PEG400 was found to be comparable, and cell outgrowth from rabbit/porcine explants was successfully observed on the materials after 3 weeks. This research underpins the manufacture of next-generation fibrous biomimetic membranes that will ultimately be used as amniotic membrane substitutes for biomedical applications including SLET.


Assuntos
Âmnio , Biomimética , Âmnio/transplante , Animais , Cegueira , Córnea , Coelhos , Suínos , Cicatrização
4.
Sci Rep ; 10(1): 892, 2020 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-31964969

RESUMO

Infectious diseases (exacerbated by antimicrobial resistance) cause death, loss of quality of life and economic burden globally. Materials with inherent antimicrobial properties offer the potential to reduce the spread of infection through transfer via surfaces or solutions, or to directly reduce microbial numbers in a host if used as implants. Additive Manufacturing (AM) techniques offer shorter supply chains, faster delivery, mass customisation and reduced unit costs, as well as highly complicated part geometries which are potentially harder to clean and sterilise. Here, we present a new approach to introducing antibacterial properties into AM, using Laser Sintering, by combining antimicrobial and base polymer powders prior to processing. We demonstrate that the mechanical properties of the resultant composite parts are similar to standard polymer parts and reveal the mode of the antibacterial activity. We show that antibacterial activity is modulated by the presence of obstructing compounds in different experimental media, which will inform appropriate use cases. We show that the material is not toxic to mammalian cells. This material could be quickly used for commercial products, and our approach could be adopted more generally to add new functionality to Laser Sintered parts.


Assuntos
Antibacterianos/química , Antibacterianos/farmacologia , Teste de Materiais/métodos , Nylons/química , Prata/química , Células Cultivadas , Liberação Controlada de Fármacos , Fibroblastos/efeitos dos fármacos , Vidro , Humanos , Lasers , Testes de Sensibilidade Microbiana , Microscopia Eletrônica de Varredura , Nylons/farmacologia , Fosfatos/química , Pós , Próteses e Implantes , Pseudomonas aeruginosa/efeitos dos fármacos , Prata/farmacocinética , Compostos de Prata/química , Espectrometria por Raios X , Staphylococcus aureus/efeitos dos fármacos , Resistência à Tração , Microtomografia por Raio-X
5.
J Funct Biomater ; 11(3)2020 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-32824017

RESUMO

Preventing the development of osteomyelitis while enhancing bone regeneration is challenging, with relatively little progress to date in translating promising technologies to the clinic. Nanoscale hydroxyapatite (nHA) has been employed as a bone graft substitute, and recent work has shown that it may be modified with silver to introduce antimicrobial activity against known pathogens. The aim of this study was to incorporate silver-doped nHA into electrospun scaffolds for applications in bone repair. Silver-doped nHA was produced using a modified, rapid mixing, wet precipitation method at 2, 5, 10 mol.% silver. The silver-doped nHA was added at 20 wt.% to a polycaprolactone solution for electrospinning. Bacteria studies demonstrated reduced bacterial presence, with Escherichia coli and Staphylococcus aureus undetectable after 96 h of exposure. Mesenchymal stem cells (MSCs) were used to study both toxicity and osteogenicity of the scaffolds using PrestoBlue® and alkaline phosphatase (ALP) assays. Innovative silver nHA scaffolds significantly reduced E. coli and S. aureus bacterial populations while maintaining cytocompatibility with mammalian cells and enhancing the differentiation of MSCs into osteoblasts. It was concluded that silver-doped nHA containing scaffolds have the potential to act as an antimicrobial device while supporting bone tissue healing for applications in orthopedic and dental bone surgery.

6.
Artigo em Inglês | MEDLINE | ID: mdl-32296691

RESUMO

The physiological wound healing process involves a cascade of events which could be affected by several factors resulting in chronic, non-healing wounds. The latter represent a great burden especially when bacterial biofilms are formed. The rise in antibiotic resistance amongst infectious microorganisms leads to the need of novel approaches to treat this clinical issue. In this context, the use of advanced biomaterials, which can enhance the physiological expression and secretion of the growth factors involved in the wound healing process, is gaining increasing attention as a robust and appealing alternative approach. Among them, mesoporous glasses are of particular interest due to their excellent textural properties and to the possibility of incorporating and releasing specific therapeutic species, such as metallic ions. One of the most attractive therapeutic ions is copper thanks to its proangiogenic and antibacterial effects. In this contribution, copper containing mesoporous glass nanoparticles were proposed as a multifunctional device to treat chronic wounds. The developed nanoparticles evidenced a very high specific surface area (740 m2/g), uniform pores of 4 nm and an almost total release of the therapeutic ion within 72 h of soaking. The produced nanoparticles were biocompatible and, when tested against Gram positive and Gram negative bacterial species, demonstrated antibacterial activity against both planktonic and biofilm bacteria in 2D cell monolayers, and in a 3D human model of infected skin. Their proangiogenic effect was tested with both the aortic ring and the chick chorioallantoic membrane assays and an increase in endothelial cell outgrowth at a concentration range between 30 and 300 ng/mL was shown. Overall, in this study biocompatible, multifunctional Cu-containing mesoporous glass nanoparticles were successfully produced and demonstrated to exert both antibacterial and proangiogenic effects.

7.
Mater Sci Eng C Mater Biol Appl ; 103: 109764, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31349470

RESUMO

Bioactive glasses (BG) are versatile materials for various biomedical applications, including bone regeneration and wound healing, due to their bone bonding, antibacterial, osteogenic, and angiogenic properties. In this study, we aimed to enhance the antibacterial activity of SiO2-CaO mesoporous bioactive glass nanoparticles (MBGN) by incorporating silver (Ag) through a surface modification approach. The modified Ag-containing nanoparticles (Ag-MBGN) maintained spherical shape, mesoporous structure, high dispersity, and apatite-forming ability after the surface functionalization. The antibacterial activity of Ag-MBGN was assessed firstly using a planktonic bacteria model. Moreover, a 3D tissue-engineered infected skin model was used for the first time to evaluate the antibacterial activity of Ag-MBGN at the usage dose of 1 mg/mL. In the planktonic bacteria model, Ag-MBGN exhibited a significant antibacterial effect against both Pseudomonas aeruginosa and Staphylococcus aureus in comparison to non-engineered (Ag-free) MBGN and the blank control. Moreover, Ag-MBGN did not show cytotoxicity towards fibroblasts at the usage dose. However, in the 3D infected skin model, Ag-MBGN only demonstrated antibacterial activity against S. aureus whereas their antibacterial action against P. aeruginosa was inhibited. In conclusion, surface modification by Ag incorporation is a feasible approach to enhance the antibacterial activity of MBGN without significantly impacting their morphology, polydispersity, and apatite-forming ability. The prepared Ag-MBGN are attractive building blocks for the development of 3D antibacterial scaffolds for tissue engineering.


Assuntos
Antibacterianos , Vidro/química , Modelos Biológicos , Nanopartículas/química , Infecções por Pseudomonas/tratamento farmacológico , Pseudomonas aeruginosa/crescimento & desenvolvimento , Prata , Pele/microbiologia , Infecções Cutâneas Estafilocócicas/tratamento farmacológico , Staphylococcus aureus/crescimento & desenvolvimento , Células 3T3 , Animais , Antibacterianos/química , Antibacterianos/farmacologia , Humanos , Camundongos , Prata/química , Prata/farmacologia
8.
APL Bioeng ; 2(2): 026103, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31069300

RESUMO

Porous microspheres have the potential for use as injectable bone fillers to obviate the need for open surgery. Successful bone fillers must be able to support vascularisation since tissue engineering scaffolds often cease functioning soon after implantation due to a failure to vascularise rapidly. Here, we test the angiogenic potential of a tissue engineered bone filler based on a photocurable acrylate-based high internal phase emulsion (HIPE). Highly porous microspheres were fabricated via two processes, which were compared. One was taken forward and investigated for its ability to support human mesenchymal progenitor cells and angiogenesis in a chorioallantoic membrane (CAM) assay. Porous microspheres with either a narrow or broad size distribution were prepared via a T-junction microfluidic device or by a controlled stirred-tank reactor of the HIPE water in oil in water (w/o/w), respectively. Culture of human embryonic stem cell-derived mesenchymal progenitor (hES-MP) cells showed proliferation over 11 days and formation of cell-microsphere aggregates. In-vitro, hES-MP cells were found to migrate into microspheres through their surface pores over time. The presence of osteoblasts, differentiated from the hES-MP cells, was evidenced through the presence of collagen and calcium after 30 days. Microspheres pre-cultured with cells were implanted into CAM for 7 days and compared with control microspheres without pre-cultured cells. The hES-MP seeded microspheres supported greater angiogenesis, as measured by the number of blood vessels and bifurcations, while the empty scaffolds attracted host chick cell ingrowth. This investigation shows that controlled fabrication of porous microspheres has the potential to create an angiogenic, bone filling material for use as a cell delivery vehicle.

9.
Proc Inst Mech Eng H ; 231(6): 565-574, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28639518

RESUMO

Additive manufacturing technologies enable the creation of very precise and well-defined structures that can mimic hierarchical features of natural tissues. In this article, we describe the development of a manufacturing technology platform to produce innovative biodegradable membranes that are enhanced with controlled microenvironments produced via a combination of selective laser melting techniques and conventional electrospinning. This work underpins the manufacture of a new generation of biomaterial devices that have significant potential for use as both basic research tools and components of therapeutic implants. The membranes were successfully manufactured and a total of three microenvironment designs (niches) were chosen for thorough characterisation. Scanning electron microscopy analysis demonstrated differences in fibre diameters within different areas of the niche structures as well as differences in fibre density. We also showed the potential of using the microfabricated membranes for supporting mesenchymal stromal cell culture and proliferation. We demonstrated that mesenchymal stromal cells grow and populate the membranes penetrating within the niche-like structures. These findings demonstrate the creation of a very versatile tool that can be used in a variety of tissue regeneration applications including bone healing.


Assuntos
Materiais Biocompatíveis , Eletricidade , Lasers , Membranas Artificiais , Microtecnologia , Animais , Materiais Biocompatíveis/farmacologia , Masculino , Teste de Materiais , Células-Tronco Mesenquimais/citologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Ratos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa