Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Braz J Cardiovasc Surg ; 33(1): 1-7, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29617494

RESUMO

OBJECTIVE: Transcatheter aortic valve replacement has been an alternative to invasive treatment for symptomatic severe aortic stenosis in high risk patients. The primary endpoint was 30-day and 1-year mortality from any cause. Secondary endpoints were to compare the clinical and echocardiographic variation pre-and post- transcatheter aortic valve replacement, and the occurrence of complications throughout a 4-year follow-up period. METHODS: This prospective cohort, nestled to a multicenter study (Registro Brasileiro de Implante de Bioprótese por Cateter), describes the experience of a public tertiary center in transcatheter aortic valve replacement. All patients who underwent this procedure between October 2011 and February 2016 were included. RESULTS: Fifty-eight patients underwent transcatheter aortic valve replacement. The 30-day all-cause mortality was 5.2% (n=3) and after 1 year was 17.2% (n=10). A significant improvement in New York Heart Association functional classification was observed when comparing pre-and post- transcatheter aortic valve replacement (III or IV 84.4% versus 5.8%; P<0.001). A decline in peak was observed (P<0.001) and mean (P<0.001) systolic transaortic gradient. The results of peak and mean post-implant transaortic gradient were sustained after one year (P=0.29 and P=0.36, respectively). Left ventricular ejection fraction did not change significantly during follow-up (P=0.41). The most frequent complications were bleeding (28.9%), the need for permanent pacemaker (27.6%) and acute renal injury (20.6%). CONCLUSION: Mortality and complications in this study were consistent with worldwide experience. Transcatheter aortic valve replacement had positive clinical and hemodynamic results, when comparing pre-and post-procedure, and the hemodynamic profile of the prosthesis was sustained throughout follow-up.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Brasil , Ecocardiografia , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Rev. bras. cir. cardiovasc ; 33(1): 1-7, Jan.-Feb. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-897979

RESUMO

Abstract Objective: Transcatheter aortic valve replacement has been an alternative to invasive treatment for symptomatic severe aortic stenosis in high risk patients. The primary endpoint was 30-day and 1-year mortality from any cause. Secondary endpoints were to compare the clinical and echocardiographic variation pre-and post- transcatheter aortic valve replacement, and the occurrence of complications throughout a 4-year follow-up period. Methods: This prospective cohort, nestled to a multicenter study (Registro Brasileiro de Implante de Bioprótese por Cateter), describes the experience of a public tertiary center in transcatheter aortic valve replacement. All patients who underwent this procedure between October 2011 and February 2016 were included. Results: Fifty-eight patients underwent transcatheter aortic valve replacement. The 30-day all-cause mortality was 5.2% (n=3) and after 1 year was 17.2% (n=10). A significant improvement in New York Heart Association functional classification was observed when comparing pre-and post- transcatheter aortic valve replacement (III or IV 84.4% versus 5.8%; P<0.001). A decline in peak was observed (P<0.001) and mean (P<0.001) systolic transaortic gradient. The results of peak and mean post-implant transaortic gradient were sustained after one year (P=0.29 and P=0.36, respectively). Left ventricular ejection fraction did not change significantly during follow-up (P=0.41). The most frequent complications were bleeding (28.9%), the need for permanent pacemaker (27.6%) and acute renal injury (20.6%). Conclusion: Mortality and complications in this study were consistent with worldwide experience. Transcatheter aortic valve replacement had positive clinical and hemodynamic results, when comparing pre-and post-procedure, and the hemodynamic profile of the prosthesis was sustained throughout follow-up.


Assuntos
Humanos , Masculino , Feminino , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Índice de Gravidade de Doença , Brasil , Próteses Valvulares Cardíacas/efeitos adversos , Ecocardiografia , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos
3.
BMJ Open ; 2(5)2012.
Artigo em Inglês | MEDLINE | ID: mdl-23103604

RESUMO

OBJECTIVE: The goal of this prospective observational study was to identify adverse events (AEs) related to the use of intravenous access sites used for infective endocarditis (IE) treatment in a tertiary care hospital. DESIGN: This is an observational, analytical and prospective study on AEs resulting from the use of intravenous access sites in patients under antimicrobial treatment for IE. Patients enrolled in the International Collaboration on Endocarditis (ICE) study had their peripheral, short-term central catheters (CVC) and peripherally inserted central catheters (PICC) monitored for AEs. SETTING: Tertiary care hospital for cardiac surgery in Rio de Janeiro, Brazil. PATIENTS: Patients over 14 years of age, hospitalised in 2009 and 2010 with possible or definite criteria for IE by the modified Duke criteria were included. MAIN OUTCOME MEASURES: AEs related to intravenous catheters: erythema and infiltration, fever, obstruction, externalisation and blood stream infection. RESULTS: Thirty-seven episodes of IE in 35 patients were studied. Mean patient age was 44.32±15.2 years; 22 (63%) were men. The number of vascular catheters studied were 253, 148 of which were peripheral, 85 CVC (21 of which for haemodialysis) and 20 PICC. The most frequent AEs were 'erythema' and 'infiltration' for peripheral catheters, 'fever' for CVCs and 'obstruction' and 'externalisation' for PICCs. The number of catheter-days was 360 for peripheral catheters, 1.156 for CVC and 420 for PICC. Kaplan-Meier curves for CVC and PICC showed statistical difference for obstruction (p<0.001) in PICCs. More bacteraemia occurred in CVC compared with PICC. CONCLUSIONS: The choice of intravenous access sites is critical in the treatment of IE. Close observation for AEs and stricter implementation of infection control measures and better manipulation of catheters are suggested.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa