Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Clin Chem Lab Med ; 61(1): 78-85, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36279170

RESUMO

OBJECTIVES: Vitamin D-binding protein (VDBP), a serum transport protein for 25-hydroxyvitamin D [25(OH)D], has three common proteoforms which have co-localized amino acid variations and glycosylation. A monoclonal immunoassay was found to differentially detect VDBP proteoforms and methods using liquid chromatography-tandem mass spectrometry (LC-MS/MS) might be able to overcome this limitation. Previously developed multiple reaction monitoring LC-MS/MS methods for total VDBP quantification represent an opportunity to probe the potential effects of proteoforms on proteolysis, instrument response and quantification accuracy. METHODS: VDBP was purified from homozygous human donors and quantified using proteolysis or acid hydrolysis and LC-MS/MS. An interlaboratory comparison was performed using pooled human plasma [Standard Reference Material® 1950 (SRM 1950) Metabolites in Frozen Human Plasma] and analyses with different LC-MS/MS methods in two laboratories. RESULTS: Several shared peptides from purified proteoforms were found to give reproducible concentrations [≤2.7% coefficient of variation (CV)] and linear instrument responses (R2≥0.9971) when added to human serum. Total VDBP concentrations from proteolysis or amino acid analysis (AAA) of purified proteoforms had ≤1.92% CV. SRM 1950, containing multiple proteoforms, quantified in two laboratories resulted in total VDBP concentrations with 7.05% CV. CONCLUSIONS: VDBP proteoforms were not found to cause bias during quantification by LC-MS/MS, thus demonstrating that a family of proteins can be accurately quantified using shared peptides. A reference value was assigned for total VDBP in SRM 1950, which may be used to standardize methods and improve the accuracy of VDBP quantification in research and clinical samples.


Assuntos
Espectrometria de Massas em Tandem , Proteína de Ligação a Vitamina D , Humanos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Proteólise , Vitamina D , Proteínas Sanguíneas/metabolismo , Aminoácidos/metabolismo
2.
Eur J Clin Microbiol Infect Dis ; 37(8): 1503-1510, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29770901

RESUMO

Vancomycin pharmacokinetic (PK) and pharmacodynamic (PD) data in neonates are based on total concentrations. However, only unbound vancomycin is pharmacologically active. The objective was to determine vancomycin protein binding and the covariates impacting unbound vancomycin concentration in neonates and young infants. In neonates and young infants to whom vancomycin was administered intermittently for medical indications, total and unbound vancomycin plasma concentrations were determined using LC-MS/MS. Sampling occurred randomly during vancomycin exposure, covering a broad range of concentrations. Impact of covariates on unbound vancomycin concentration was determined using linear regression. Significant results of the univariate regressions were entered in a stepwise multiple regression. Passing-Bablok regression and Bland-Altman were used to assess the difference between measured and calculated unbound vancomycin concentration. Thirty-seven samples in 33 patients (median (interquartile range) gestational age 35 (29-39) weeks) were collected. Median total and unbound vancomycin concentrations were 14.2 (7.4-20.6) and 13.6 (7.2-22.5) mg/L, respectively. Median unbound fraction was 0.90 (0.77-0.98). Multiple regression revealed total vancomycin concentration (ß = 0.884, p < 0.001) and albumin (ß = - 0.323, p = 0.007) as most important covariates of unbound vancomycin concentrations, with an R2 adjusted of 0.953 (p < 0.0001). Mean absolute difference between calculated and measured unbound vancomycin was - 0.008 (95% CI - 0.92-0.91) mg/L. The unbound vancomycin fraction in neonates is higher compared to that in children and adults, and total vancomycin concentration and albumin were the most important covariates of unbound vancomycin concentration. Integration of protein binding in future PK/PD analyses is appropriate to optimize vancomycin dosing and to determine population-specific vancomycin PD targets for neonates.


Assuntos
Antibacterianos/farmacocinética , Vancomicina/farmacocinética , Fatores Etários , Antibacterianos/administração & dosagem , Biomarcadores , Cromatografia Líquida , Monitoramento de Medicamentos , Feminino , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Masculino , Ligação Proteica , Fatores de Risco , Espectrometria de Massas em Tandem , Vancomicina/administração & dosagem
3.
Nephrol Dial Transplant ; 32(3): 497-507, 2017 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28089986

RESUMO

Background: We recently published and validated the new serum creatinine (Scr)-based full-age-spectrum equation (FAS crea ) for estimating the glomerular filtration rate (GFR) for healthy and kidney-diseased subjects of all ages. The equation was based on the concept of normalized Scr and shows equivalent to superior prediction performance to the currently recommended equations for children, adolescents, adults and older adults. Methods: Based on an evaluation of the serum cystatin C (ScysC) distribution, we defined normalization constants for ScysC ( Q cysC = 0.82 mg/L for ages <70 years and Q cysC = 0.95 mg/L for ages ≥70 years). By replacing Scr/ Q crea in the FAS crea equation with ScysC/ Q cysC , or with the average of both normalized biomarkers, we obtained new ScysC-based (FAS cysC ) and combined Scr-/ScysC-based FAS equations (FAS combi ). To validate the new FAS cysC and FAS combi we collected data on measured GFR, Scr, ScysC, age, gender, height and weight from 11 different cohorts including n = 6132 unique white subjects (368 children, aged ≤18 years, 4295 adults and 1469 older adults, aged ≥70 years). Results: In children and adolescents, the new FAS cysC equation showed significantly better performance [percentage of patients within 30% of mGFR (P30) = 86.1%] than the Caucasian Asian Paediatric Adult Cohort equation (P30 = 76.6%; P < 0.0001), or the ScysC-based Schwartz equation (P30 = 68.8%; P < 0.0001) and the FAS combi equation outperformed all equations with P30 = 92.1% (P < 0.0001). In adults, the FAS cysC equation (P30 = 82.6%) performed equally as well as the Chronic Kidney Disease Epidemiology Collaboration equation (CKD-EPI cysC ) (P30 = 80.4%) and the FAS combi equation (P30 = 89.9%) was also equal to the combined CKD-EPI equation (P30 = 88.2%). In older adults, FAS cysC was superior (P30 = 88.2%) to CKD-EPI cysC (P30 = 84.4%; P < 0.0001) and the FAS combi equation (P30 = 91.2%) showed significantly higher performance than the combined CKD-EPI equation (P30 = 85.6%) (P < 0.0001). Conclusion: The FAS equation is not only applicable to all ages, but also for all recommended renal biomarkers and their combinations.


Assuntos
Creatinina/sangue , Cistatina C/sangue , Taxa de Filtração Glomerular , Insuficiência Renal Crônica/sangue , Adolescente , Adulto , Idoso , Biomarcadores/sangue , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Testes de Função Renal , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/diagnóstico , População Branca , Adulto Jovem
4.
Antimicrob Agents Chemother ; 59(11): 7073-9, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26349820

RESUMO

The unbound drug hypothesis states that only unbound drug concentrations are active and available for clearance, and highly variable results regarding unbound vancomycin fractions have been reported in the literature. We have determined the unbound vancomycin fractions in four different patient groups by a liquid chromatography tandem mass spectrometry (LC-MS/MS) method and identified factors that modulate vancomycin binding. We have further developed and validated a prediction model to estimate unbound vancomycin concentrations. Vancomycin (unbound and total) concentrations were measured in 90 patients in four different hospital wards (hematology [n = 33 samples], intensive care unit [ICU] [n = 51], orthopedics [n = 44], and pediatrics [age range, 6 months to 14 years; n = 18]) by a validated LC-MS/MS method. Multiple linear mixed model analysis was performed to identify patient variables that were predictive of unbound vancomycin fractions and concentrations. The variables included in the model were patient age, ward, number of coadministered drugs with high protein binding, kidney function (estimated glomerular filtration rate [determined by Chronic Kidney Disease Epidemiology Collaboration formula]), alpha-1-acid glycoprotein, albumin, total bilirubin, IgA, IgM, urea, and total vancomycin concentrations. In the pediatric cohort, the median unbound vancomycin fraction was 81.3% (range, 61.9 to 95.9%), which was significantly higher (P < 0.01) than the unbound fraction found in the three adult patient cohorts (hematology, 60.6% [48.7 to 90.6%]; ICU, 61.7% [47.0 to 87.6%]; orthopedics, 56.4% [45.9 to 78.0%]). The strongest significant predictor of the unbound vancomycin concentration was the total drug concentration, completed by albumin in the pediatric cohort and albumin and IgA in the adult cohorts. Validation of our model was performed with data from 13 adult patients. A mean difference of 0.3 mg/liter (95% confidence interval [CI], -1.3 to 0.7 mg/liter; R(2) = 0.99 [95% CI, 0.95 to 0.99]) between measured and calculated unbound vancomycin concentrations demonstrated that the predictive performance of our model was favorable. Unbound vancomycin fractions vary significantly between pediatric and adult patients. We developed a formula to estimate the unbound fraction derived from total vancomycin, albumin, and IgA concentrations in adult patients.


Assuntos
Vancomicina/sangue , Vancomicina/metabolismo , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Albuminas/metabolismo , Bilirrubina/sangue , Bilirrubina/metabolismo , Cromatografia Líquida , Feminino , Humanos , Imunoglobulina A/sangue , Imunoglobulina A/metabolismo , Imunoglobulina M/sangue , Imunoglobulina M/metabolismo , Masculino , Pessoa de Meia-Idade , Ligação Proteica , Espectrometria de Massas em Tandem , Adulto Jovem
5.
Anal Bioanal Chem ; 407(20): 6191-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26072209

RESUMO

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is the method of choice for quantifying small molecules in research and clinical setting. Although there is a large toolkit to increase quantification levels for LC-MS/MS, these techniques are sometimes insufficient to attain the needed limits of quantification (LOQs) or the method becomes too impractical for routine use. We examined the possibilities and limitations of signal summing, an under-utilized, easy-to-apply practice to increase LOQs for an immunosuppressant LC-MS/MS method. The limits of signal summing for everolimus were tested by running samples of everolimus at three concentrations in triplicate programming, increasing amounts of identical transitions in a constant cycle time up to the maximum number the software permitted to sum. The increase in peak area and the signal-to-noise ratio were determined. The effect on imprecision of peak areas and response ratios was evaluated by injection of a low concentration of everolimus tenfold using respectively one and five identical transitions, retaining an identical ion counting time. We compared the imprecision, LOQ, and recovery for our routine everolimus method (using one transition for everolimus and one for d3-everolimus) and an adapted method summing three identical transitions for everolimus (and one for d3-everolimus). The increase in signal was close to the theoretically expected one with a larger experimental spread for everolimus once more than five transitions were used. There was no clear beneficial effect of summing on imprecision. The adapted everolimus method showed a lower LOQ, but comparable imprecision and recovery as the routine method. Quantification levels can be improved by signal summing. No clear effect on imprecision was observed.


Assuntos
Cromatografia Líquida/métodos , Everolimo/sangue , Imunossupressores/sangue , Espectrometria de Massas em Tandem/métodos , Monitoramento de Medicamentos/métodos , Everolimo/análise , Humanos , Imunossupressores/análise , Limite de Detecção , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Software
7.
BMC Nephrol ; 15: 62, 2014 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-24731305

RESUMO

BACKGROUND: Urinary creatinine can be quantified by Jaffe or enzymatic assays and is commonly used as denominator of urinary excretion of electrolytes or protein. Paired analysis in pediatric and adult samples documented inter-assay differences (up to 80%). We verified the interchangeability of two IDMS-traceable assays (Jaffe and enzymatic) for neonatal urine and report on neonatal urinary creatinine values using these IDMS-traceable methods. METHODS: Creatinine was measured in 84 neonatal urine samples from 46 neonates by an IDMS traceable Jaffe and enzymatic assay (Roche Diagnostics, Cobas c702 module). Creatinine values, differences in urinary creatinine and clinical characteristics were described and covariates of between assay difference were explored (Wilcoxon, Bland-Altman, correlation, multiple regression). RESULTS: Median Jaffe and enzymatic urinary creatinine concentrations were 9.25 (range 3.7-42.2) and 9.15 (range 3.8-42.9) mg/dL respectively, resulting in a median difference of 0.08 (SD 0.6, range -2.4 to 0.96) mg/dL. In a multiple regression model, urinary enzymatic creatinine concentration (r = 0.45) and postnatal age (r = -0.59) remained independent variables of the difference between both assays (r2 adj = 0.45). CONCLUSIONS: The tested IDMS-traceable assays showed interchangeable in heterogeneous neonatal urine samples. Using these assays, neonatal urinary creatinine showed 5-20 fold lower values than those observed in children or adults with a significant negative correlation with postnatal age.


Assuntos
Algoritmos , Creatinina/urina , Diagnóstico por Computador/métodos , Ensaios Enzimáticos/métodos , Ensaios Enzimáticos/normas , Testes de Função Renal/métodos , Testes de Função Renal/normas , Bélgica , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
AAPS J ; 26(1): 23, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-38302833

RESUMO

Special populations, like geriatric patients, experience altered paracetamol pharmacokinetics (PK), complicating pain management. More PK research is essential to optimize paracetamol (acetaminophen) dosing. Yet, the reference method ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) is not readily available. Therefore, we aimed to evaluate the agreement between UPLC-MS/MS and the more accessible colorimetric Roche acetaminophen (ACETA) assay in quantifying paracetamol plasma concentrations, to facilitate PK studies and therapeutic drug monitoring for pain management. Patient data and plasma samples were obtained from a prospective study including geriatric patients admitted to the geriatric wards. ACETA and UPLC-MS/MS assays were performed in two separate laboratories. Bland-Altman plot and Passing-Bablok regression were used to assess agreement. Accuracy was evaluated using the McNemar test for a threshold value of 10 mg/L. Population PK modeling was employed to bridge PK data obtained from both methods (NONMEM 7.5). A total of 242 plasma sample pairs were available from 40 geriatric patients (age range, 80-95 years). Paracetamol plasma concentrations from ACETA (median 9.8 [interquartile range 6.1-14.4] mg/L) and UPLC-MS/MS (9.5 [6.2-14.8] mg/L) did not differ significantly (P > 0.05). No significant proportional nor additive bias was observed between both assay methods. The classification accuracy (at threshold 10 mg/L) was 85% (P = 0.414). The conversion factor between ACETA and UPLC-MS/MS was estimated at 1.06 (relative standard error 5%), yet with a 13.4% (relative standard error 23%) interindividual variability. ACETA assay showed no systematic bias in comparison with the UPLC-MS/MS assay in determining paracetamol exposure in geriatric blood samples despite the imprecision.


Assuntos
Acetaminofen , Colorimetria , Humanos , Idoso , Idoso de 80 Anos ou mais , Cromatografia Líquida/métodos , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Estudos Prospectivos
9.
Anal Bioanal Chem ; 405(26): 8569-77, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23892882

RESUMO

The need for a routinely applicable assay to measure low estradiol levels in adult men, postmenopausal women, and young adolescents was recently discussed in an Endocrine Society position statement. Our aim was to develop a sensitive liquid chromatography-tandem mass spectrometry method for estradiol and estrone in human serum without the need for derivatization or extended extraction protocols. After protein precipitation of serum with a mixture of methanol/acetonitrile (85/15) (v/v) containing isotopic internal standards (17ß-estradiol-16,16,17-d 3 and estrone-2,3,4-(13)C), we quantified estradiol and estrone by two-dimensional liquid chromatography-tandem mass spectrometry with electrospray ionization in the negative mode monitoring 5 × 271.20→145.00 (17ß-estradiol) and 269.20→145.00 (estrone). Sensitivity was increased by using fluoride and summation of 5 identical transitions for estradiol. Our method was analytically validated, compared against direct immunoassays using serum of 25 adult men, and clinically tested by measuring samples of 3 men at baseline and after chemical castration, 30 postmenopausal women and 15 patients receiving aromatase inhibitors. Total imprecision was below 20% for the low quality controls. Limit of quantification was 1.3 ng/L (4.8 pmol/L) for estradiol and 1.2 ng/L (4.4 pmol/L) for estrone. Estradiol in Certified Reference Material BCR-576 was within specified uncertainty limits. No significant ion suppression or interference was observed. Our method showed modest correlation with direct immunoassay for estradiol (r(2) = 0.64) but no correlation for estrone (r(2) = 0.12). Patient sample results were within expected ranges. In conclusion, we developed a routinely applicable liquid chromatography-tandem mass spectrometry method for estradiol and estrone measurement which is sensitive enough for use in men, postmenopausal women, and young adolescents.


Assuntos
Cromatografia Líquida/métodos , Estradiol/sangue , Estrona/sangue , Espectrometria de Massas em Tandem/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Imunoensaio , Limite de Detecção , Masculino , Pessoa de Meia-Idade
10.
Eur J Pediatr ; 172(11): 1547-50, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23828132

RESUMO

In light of the widespread use of ecstasy, it is surprising that only few cases of intoxicated young children have been reported. Patients almost invariably present with convulsions accompanied by sympathetic signs and symptoms such as hyperthermia. Two new cases of toddlers intoxicated with ecstasy are described. The first patient, a 19-month-old boy, presented with convulsions but no sympathetic signs. The pediatrician's suspicion was raised because of the absence of a postictal state. The second patient, a 20-month-old girl, had a more typical presentation with convulsions and hyperthermia. Her story illustrates the fact that immunoassays for toxicological screening can easily miss traces of additional illicit drugs present in the urine such as cocaine. The presence of other illicit drugs provides clues to the child's risky environment and should lead to further investigation. Finally, we review the available literature on ecstasy intoxication to summarize the key presenting manifestations.


Assuntos
Drogas Ilícitas/intoxicação , N-Metil-3,4-Metilenodioxianfetamina/intoxicação , Convulsões/induzido quimicamente , Feminino , Febre/induzido quimicamente , Humanos , Lactente , Masculino
12.
J Anal Toxicol ; 47(1): e10-e13, 2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-35983905

RESUMO

A young woman with a history of several suicide attempts was admitted to the hospital after suspicion of a new intoxication without definite identification of the causing agent. The patient had a high anion gap metabolic acidosis (HAGMA) with respiratory compensation, a lactate gap and an osmolar gap at admission. Initial toxicological screening showed no abnormalities except for a weak positive gamma-hydroxy butyric acid (GHB) enzymatic screen in urine. This finding could not be confirmed using chromatographic analysis nor be explained by the presence of known cross-reacting substances like ethanol. In this case, falsely elevated urinary GHB screening was caused by the ingestion of ethylene glycol. To confirm that the interference was due to ethylene glycol or its metabolites, we performed a spiking experiment. Cross reactivity was linked to ethylene glycol and was low in our experiments (0.1-0.2%). Substantial amounts of ethylene glycol are required to slightly elevated GHB results, depending on the endogenous cutoff used. We can conclude that ethylene glycol can give rise to falsely elevated urinary GHB levels at ethylene glycol concentrations that are typically found in intoxications.


Assuntos
Acidose , Intoxicação , Oxibato de Sódio , Feminino , Humanos , Ácido Butírico , Equilíbrio Ácido-Base , Acidose/metabolismo , Etilenoglicol , Etanol
15.
Biochem Med (Zagreb) ; 30(1): 010802, 2020 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-31839727

RESUMO

INTRODUCTION: Hypoglycaemia has been reported as an unusual complication of tramadol use and in a few cases of tramadol poisoning, but the exact mechanism is not known. CASE DESCRIPTION: An ambulance crew was dispatched to an unconscious 46-year old man. A glucometer point-of-care measurement revealed a profound hypoglycaemia (1.9 mmol/L). Treatment with intravenous glucose was started and the patient was transported to the hospital. The patient had several episodes of pulseless electrical activity requiring cardiopulmonary resuscitation in the ambulance and upon arrival in the hospital. Despite continuous glucose infusion the hypoglycaemia was difficult to correct during the next few hours and the patient developed hypokalaemia. Further investigation to identify the cause of hypoglycaemia revealed that insulin and C-peptide were inappropriately raised. A toxicological investigation revealed the presence of tramadol and its metabolites in lethal concentrations. Also acetaminophen, ibuprofen and lormetazepam were present. Ethanol screening was negative (< 0.1 g/L) and no sulfonylurea were detected. The patient developed multiple organ failure, but eventually recovered. WHAT HAPPENED: The hypoglycaemia was caused by inappropriate stimulation of insulin secretion in a patient intoxicated with tramadol. The sudden hypokalaemia was caused by a massive intracellular shift of potassium in response to the hyperinsulinemia, triggered by the intravenous administration of glucose. MAIN LESSON: To our knowledge, we are the first to document a significant rise in endogenous insulin production in a hypoglycaemic patient presenting with tramadol intoxication. Our observation suggests that hyperinsulinemia could be the cause of the hypoglycaemia associated with tramadol use.


Assuntos
Analgésicos Opioides/efeitos adversos , Hipoglicemia/diagnóstico , Tramadol/efeitos adversos , Analgésicos Opioides/uso terapêutico , Glicemia/análise , Peptídeo C/sangue , Glucose/administração & dosagem , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemia/etiologia , Insulina/sangue , Masculino , Pessoa de Meia-Idade , Dor/tratamento farmacológico , Tramadol/uso terapêutico
16.
Nat Commun ; 11(1): 5997, 2020 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-33244003

RESUMO

The vitamin D receptor is highly expressed in the gastrointestinal tract where it transacts gene expression. With current limited understanding of the interactions between the gut microbiome and vitamin D, we conduct a cross-sectional analysis of 567 older men quantifying serum vitamin D metabolites using LC-MSMS and defining stool sub-Operational Taxonomic Units from16S ribosomal RNA gene sequencing data. Faith's Phylogenetic Diversity and non-redundant covariate analyses reveal that the serum 1,25(OH)2D level explains 5% of variance in α-diversity. In ß-diversity analyses using unweighted UniFrac, 1,25(OH)2D is the strongest factor assessed, explaining 2% of variance. Random forest analyses identify 12 taxa, 11 in the phylum Firmicutes, eight of which are positively associated with either 1,25(OH)2D and/or the hormone-to-prohormone [1,25(OH)2D/25(OH)D] "activation ratio." Men with higher levels of 1,25(OH)2D and higher activation ratios, but not 25(OH)D itself, are more likely to possess butyrate producing bacteria that are associated with better gut microbial health.


Assuntos
Calcifediol/análise , Calcitriol/análise , Microbioma Gastrointestinal/fisiologia , Idoso , Idoso de 80 Anos ou mais , Butiratos/metabolismo , Calcifediol/metabolismo , Calcitriol/metabolismo , Estudos Transversais , DNA Bacteriano/isolamento & purificação , Fezes/química , Fezes/microbiologia , Humanos , Vida Independente , Mucosa Intestinal/metabolismo , Mucosa Intestinal/microbiologia , Masculino , Filogenia , RNA Ribossômico 16S/genética
17.
Afr J Lab Med ; 9(2): 1041, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32934915

RESUMO

BACKGROUND: Past and recent outbreaks have highlighted the vulnerability of humans to infectious diseases, which represent serious economic and health security threats. A paradigm shift in the management of sanitary crises is urgently needed. Based on lessons from the 2014 Ebola outbreak, the Praesens Foundation has developed an all-terrain mobile biosafety laboratory (MBS-Lab) for effective field diagnostics capabilities. OBJECTIVE: The aim of the study was to train African teams and run a field evaluation of the MBS-Lab, including robustness, technical and operational sustainability, biosafety, connectivity, turn-around times for testing and result delivery. METHODS: The MBS-Lab was deployed in Senegal in October 2017 for a six-month field assessment under various ecological conditions and was mobilised during the dengue outbreaks in 2017 and 2018. RESULTS: The MBS-Lab can be considered an off-grid solution that addresses field challenges with regard to working conditions, mobility, deployment, environment and personnel safety. Blood (n = 398) and nasal swab (n = 113) samples were collected from 460 study participants for molecular screening for acute febrile illnesses and respiratory infections. The results showed that malaria (particularly in Kédougou) and upper respiratory tract infections remain problematic. Suspected dengue samples were tested on board during the dengue outbreaks in 2017 (882 tests; 128 confirmed cases) and 2018 (1736 tests; 202 confirmed cases). CONCLUSION: The MBS-Lab is an innovative solution for outbreak response, even in remote areas. The study demonstrated successful local ownership and community engagement. The MBS-Lab can also be considered an open mobile healthcare platform that offers various opportunities for field-deployable, point-of-care technologies for surveillance programmes.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa