Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Gynecol Endocrinol ; 31(4): 296-300, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25539143

RESUMO

Basal serum 17OHP measurement remains the first screening step for nonclassic congenital adrenal hyperplasia (NCCAH) and the accuracy of the test is of high value. The aim of this study was to compare the accuracy of immunoassays to LC-MS/MS in the assessment of serum 17OHP and androgens concentration in women with hyperandrogenism and controls. 17OHP, total testosterone, androstendione and DHEA-S were measured in 39 women with clinically and/or biochemically evident hyperandrogenism and in 29 age-matched controls without clinical hyperandrogenism. 17OHP and androgens were measured by immunoassays and by LC-MS/MS. In patients group median 17OHP level measured by immunoassays was significantly higher compared to LC-MS/MS (5.49 nmol/l-ELISA NovaTec® and 3.57 nmol/l-ELISA DRG® versus 1.56 nmol/l-LC-MS/MS p < 0.0001) as well as in the control group (2.58 nmol/l-ELISA DRG® versus 1.14 nmol/l-LC-MS/MS p < 0.0001). Additional, unnecessary diagnostic procedures explaining elevated 17OHP level were undertaken in 85% of patients when NovaTec® test was used, in 50% when ELISA DRG® and in none when LC-MS/MS method was applied. Total testosterone, androstendione and DHEA-S concentrations in the patients and the controls assessed by the immunoassays were also significantly higher compared to LC-MS/MS. LC-MS/MS is more reliable diagnostic tool in the measurement of serum 17OHP and androgens concentrations compared to immunoassays in women with hyperandrogenism.


Assuntos
17-alfa-Hidroxiprogesterona/sangue , Hiperplasia Suprarrenal Congênita/diagnóstico , Adolescente , Hiperplasia Suprarrenal Congênita/sangue , Adulto , Androstenodiona/sangue , Cromatografia Líquida de Alta Pressão , Sulfato de Desidroepiandrosterona/sangue , Diagnóstico Diferencial , Reações Falso-Positivas , Feminino , Hospitais Universitários , Humanos , Imunoensaio , Polônia , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem , Testosterona/sangue , Adulto Jovem
2.
Ann Transplant ; 20: 483-92, 2015 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-26313036

RESUMO

BACKGROUND Mycophenolic acid (MPA) prodrugs are anti-proliferative immunosuppressive agents commonly used after organ transplantation. Although they are generally well tolerated by patients, adverse effects may occur. It is postulated that MPA metabolites could also contribute to these adverse effects. MATERIAL AND METHODS The objective of this study was the assessment of concentrations of total MPA and its metabolites, phenyl glucuronide (MPAG), acyl glucuronide (AcMPAG) and glucoside (GluMPA), using liquid chromatography combined with mass spectrometry (LC/MS/MS) in two groups: kidney transplant recipients and liver transplant patients. Associations of MPA and its metabolites with adverse effects were analyzed. RESULTS The study group consisted of 211 recipients of liver or kidney transplants who received immunosuppressive therapy, including MPA prodrugs. Multivariant analysis showed a positive influence of MPA on gastroenterotoxicity in kidney transplant recipients. In liver patients, gastroenterotoxicity was associated with lower MPAG concentrations. A positive influence of AcMPAG on bacterial infections in liver transplant patients was observed. In liver transplant recipients, a positive influence of MPA and a negative influence of GluMPA levels on the PLT count were revealed. MPA and its metabolites did not influence the hemoglobin levels in both groups. There were no significant relationships among MPA, its metabolites and WBC counts. CONCLUSIONS In kidney transplant recipients, total MPA trough concentration is associated with gastroenterotoxicity and its monitoring could have important role in management of gastrointestinal complications. The quantification of AcMPAG in liver recipients receiving MPA may be helpful in avoiding bacterial infections. GluMPA seems to have a toxic effect on thrombopoiesis.


Assuntos
Infecções Bacterianas/etiologia , Glucosídeos/sangue , Glucuronídeos/sangue , Imunossupressores/uso terapêutico , Transplante de Rim/efeitos adversos , Transplante de Fígado/efeitos adversos , Ácido Micofenólico/análogos & derivados , Adulto , Infecções Bacterianas/sangue , Ciclosporina/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ácido Micofenólico/sangue , Tacrolimo/uso terapêutico , Transplantados
3.
Artigo em Inglês | MEDLINE | ID: mdl-23584041

RESUMO

Therapeutic drug monitoring of immunosuppressive agents is a critical and essential part of patient therapy after organ transplantation. We have developed high-throughput, robust, and rapid liquid chromatography-tandem mass spectrometry (UPLC/MS/MS) methods with common pretreatment procedures for simultaneous quantification of four immunosuppressive agents (everolimus, sirolimus, tacrolimus, and cyclosporin A) in whole blood and one immunosuppressant (mycophenolic acid) in plasma. The new approach used in this work is based on improved sample preparation procedures allowing the analysis of five immunosuppressive drugs. Whole blood was prepared by transferring 100µL of blood into a 1.5-mL silanized conical test tube. Zinc sulfate solution (150µL), containing deuterated internal standards, was added to perform hemolysis. The samples were vortexing for 10s, followed by the addition of 250µL acetonitrile, containing internal standard for cyclosporin A, to precipitate proteins. The mixture was vortexed for 1min and centrifuged for 2min at 14,000rpm. The whole supernatant was transferred to a vial. To prepare blood plasma, the hemolysis step involving the addition of zinc sulfate was omitted and, instead of acetonitrile, methanol was used as the solvent for the internal standard (mycophenolic acid-d3). The volumes of chemicals used in this procedure were the same as those used in the procedure for immunosuppressants in whole blood. The basic validation parameters for the analytical methods were limits of detection (0.5ng/mL for everolimus, sirolimus and tacrolimus, 25ng/mL for cyclosporin A and 100ng/mL for mycophenolic acid), precision (<15%), recovery (>84%), repeatability and reproducibility. Possible mutual ion suppression was eliminated in the presence of internal standards. The method developed for the quantitation of immunosuppressants in whole blood was used to analyze 276 patient samples containing tacrolimus and 55 samples containing cyclosporin A. The results from LC/MS/MS were compared to those obtained from immunoassays of the same samples. Immunoassays significantly overestimated the concentrations of immunosuppressants.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Ciclosporina/sangue , Monitoramento de Medicamentos/métodos , Imunossupressores/sangue , Sirolimo/análogos & derivados , Sirolimo/sangue , Tacrolimo/sangue , Everolimo , Feminino , Humanos , Imunoensaio/métodos , Limite de Detecção , Masculino , Espectrometria de Massas em Tandem/métodos
4.
Pol J Radiol ; 76(3): 33-7, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22802839

RESUMO

BACKGROUND: Peyronie's disease (PD) is characterized by the formation of fibrous tissue plaques within the tunica albuginea, usually causing a penile deformity and a subsequent erectile dysfunction. Diagnosis of PD is based on medical and sexual history, physical examination and imaging examinations, i.e.: ultrasound, color Doppler ultrasound, magnetic resonance and X-ray mammography. MATERIAL/METHODS: Ultrasound appears superior to all other methods for depicting calcifications, with the detection rate of 100%. It is safe, non-invasive, repeatable and reliable. It should be a method of choice in most standard cases of Peyronie's disease. With color Doppler ultrasound (CDU), one can find hyperperfusion around the plaques as a sign of inflammation in the active state of the disease. CDU is useful in diagnosing erectile dysfunction which is observed in most cases of PD. RESULTS: MR is superior to US and X-ray as regards the detection of periplaque inflammation, though this information can be obtained from medical history and penile plaque palpation. MR, being an expensive imaging modality, should be reserved for special cases, i.e.: plaques located at the penile basis, a suspicion of malignant disease, and prior penile surgery. CONCLUSIONS: X-ray mammography is the most accurate in showing calcifications as well as the angle of penile curvature. However, the possibility of obtaining this information does not justify the use of ionizing radiation for that purpose.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa