RESUMO
We have built and characterized, to our knowledge, the first six-telescope discrete beam combiner (DBC) for stellar interferometry in the astronomical J-band. It is the DBC with the largest number of beam combinations and was manufactured using ultrafast laser inscription in borosilicate glass, with a throughput of ≈56%. For calibration of the visibility-to-pixel matrix, we use a two-input Michelson interferometer and extract the complex visibility. A visibility amplitude of 1.05 and relative precision of 2.9% and 3.8% are extracted for 1328 nm and 1380 nm, respectively. Broadband (≤40n m) characterization is affected by dispersion but shows similar performance.
RESUMO
We present the first on-sky results of a four-telescope integrated optics discrete beam combiner (DBC) tested at the 4.2 m William Herschel Telescope. The device consists of a four-input pupil remapper followed by a DBC and a 23-output reformatter. The whole device was written monolithically in a single alumino-borosilicate substrate using ultrafast laser inscription. The device was operated at astronomical H-band (1.6 µm), and a deformable mirror along with a microlens array was used to inject stellar photons into the device. We report the measured visibility amplitudes and closure phases obtained on Vega and Altair that are retrieved using the calibrated transfer matrix of the device. While the coherence function can be reconstructed, the on-sky results show significant dispersion from the expected values. Based on the analysis of comparable simulations, we find that such dispersion is largely caused by the limited signal-to-noise ratio of our observations. This constitutes a first step toward an improved validation of the DBC as a possible beam combination scheme for long-baseline interferometry.
RESUMO
We show the results of simulation and experimental study of a 4-telescope zig-zag discrete beam combiner (DBC) for long-baseline stellar interferometry working at the astronomical L band (3 - 4â µm) under the influence of a narrow bandwidth light source. Following Saviauk et al. (2013), we used a quasi-monochromatic visibility-to-pixel matrix (V2PM) for retrieving the complex coherence functions from simulated and experimentally measured power at the output of the device. Simulation and coefficient of determination (R2) measurements show that we are able to retrieve the visibility amplitudes with >95 % accuracy of our chromatic model source up to a bandwidth of 100 nm centred at 3.5â µm. We characterized a DBC manufactured by 3D ultra-fast laser inscription (ULI) written on gallium lanthanum sulphate (GLS). Experimental results showed retrieval of visibility amplitude with an accuracy of 80-90 % at 69 nm bandwidth, validating our simulation. The standard deviation of experimental phase residuals are between 0.1-0.4 rad, which shows that the retrieval procedure is sufficient to get good quality images, where phase perturbations of less than 1 rad are expected under good seeing conditions for astronomical applications.
RESUMO
Epsilon Aurigae (epsilon Aur) is a visually bright, eclipsing binary star system with a period of 27.1 years. The cause of each 18-month-long eclipse has been a subject of controversy for nearly 190 years because the companion has hitherto been undetectable. The orbital elements imply that the opaque object has roughly the same mass as the visible component, which for much of the last century was thought to be an F-type supergiant star with a mass of approximately 15M[symbol:see text] (M[symbol:see text], mass of the Sun). The high mass-to-luminosity ratio of the hidden object was originally explained by supposing it to be a hyperextended infrared star or, later, a black hole with an accretion disk, although the preferred interpretation was as a disk of opaque material at a temperature of approximately 500 K, tilted to the line of sight and with a central opening. Recent work implies that the system consists of a low-mass (2.2M[symbol:see text]-3.3M[symbol:see text]) visible F-type star, with a disk at 550 K that enshrouds a single B5V-type star. Here we report interferometric images that show the eclipsing body moving in front of the F star. The body is an opaque disk and appears tilted as predicted. Adopting a mass of 5.9M[symbol:see text] for the B star, we derive a mass of approximately (3.6 +/- 0.7)M[symbol:see text] for the F star. The disk mass is dynamically negligible; we estimate it to contain approximately 0.07M[symbol:see text] (M[symbol:see text], mass of the Earth) if it consists purely of dust.
RESUMO
We present a dual-color laser scanning endomicroscope capable of fluorescence lifetime endomicroscopy at one frame per second (FPS). The scanning system uses a coherent imaging fiber with 30,000 cores. High-speed lifetime imaging is achieved by distributing the signal over an array of 1024 parallel single-photon avalanche diode detectors (SPADs), minimizing detection dead-time maximizing the number of photons detected per excitation pulse without photon pile-up to achieve the high frame rate. This also enables dual color fluorescence imaging by temporally shifting the dual excitation lasers, with respect to each other, to separate the two spectrally distinct fluorescent decays in time. Combining the temporal encoding, to provide spectral separation, with lifetime measurements we show a one FPS, multi-channel endomicroscopy platform for clinical applications and diagnosis. We demonstrate the potential of the system by imaging SmartProbe labeled bacteria in ex vivo samples of human lung using lifetime to differentiate bacterial fluorescence from the strong background lung autofluorescence which was used to provide structural information.
RESUMO
BACKGROUND: Unilateral absence of the pulmonary artery (UAPA) is a rare congenital malformation often associated with other cardiac anomalies; however it may occur as an isolated lesion. Isolated absence of the right pulmonary artery is twice more frequent than that of the left pulmonary artery. Patients with isolated UAPA are usually asymptomatic at birth; thereafter they may develop a progression of symptoms such as exercise intolerance, dyspnea, chest pain, hemoptysis and recurrent pulmonary infections. As patients may remain asymptomatic or have vague symptoms, the diagnosis of isolated UAPA can be difficult to make in infancy. Indeed, most cases described in literature are adults. Due to the rarity of neonatal presentation, there is no consensus regarding the treatment of this malformation. CASE PRESENTATION: Herein, the case of a two-day-old term female infant, born after uneventful pregnancy, who required a cardiological assessment for a light murmur, is reported; an echocardiogram demonstrated an isolated unilateral absence of the right pulmonary artery, confirmed by means of magnetic resonance imaging (MRI) performed 1 month after child's birth. Besides this finding, MRI showed a slightly increased lumen and size of the main and left pulmonary arteries. The right lung was shown to be perfused by some systemic collateral arteries. In the absence of any other cardiovascular malformation, our patient did not need any treatment. As symptoms may occur later in life, a thorough clinical and cardiological follow up was immediately started. Three years later, she is still asymptomatic, showing adequate growth, without any sign of pulmonary hypertension. CONCLUSIONS: Isolated UAPA is a very rare malformation with a diverse clinical presentation. To the best of our knowledge, this is the second case of neonatal presentation of UAPA reported in literature to date. We believe that our case report supports the opinion that a prompt cardiological evaluation is needed whenever a newborn shows signs and/or symptoms of cardiorespiratory concern. Any missed neonatal diagnosis of UAPA may contribute to the later age at presentation, with resultant higher risk of morbidity and mortality and greater therapeutical difficulties.
Assuntos
Ecocardiografia Doppler em Cores/métodos , Imagem Cinética por Ressonância Magnética/métodos , Artéria Pulmonar/diagnóstico por imagem , Atresia Pulmonar/diagnóstico , Diagnóstico Diferencial , Feminino , Humanos , Recém-Nascido , Artéria Pulmonar/anormalidadesRESUMO
We demonstrate a fast two-color widefield fluorescence microendoscopy system capable of simultaneously detecting several disease targets in intact human ex vivo lung tissue. We characterize the system for light throughput from the excitation light emitting diodes, fluorescence collection efficiency, and chromatic focal shifts. We demonstrate the effectiveness of the instrument by imaging bacteria (Pseudomonas aeruginosa) in ex vivo human lung tissue. We describe a mechanism of bacterial detection through the fiber bundle that uses blinking effects of bacteria as they move in front of the fiber core providing detection of objects smaller than the fiber core and cladding (â¼3 µm â¼3 µm ). This effectively increases the measured spatial resolution of 4 µm 4 µm . We show simultaneous imaging of neutrophils, monocytes, and fungus (Aspergillus fumigatus) in ex vivo human lung tissue. The instrument has 10 nM and 50 nM sensitivity for fluorescein and Cy5 solutions, respectively. Lung tissue autofluorescence remains visible at up to 200 fps camera acquisition rate. The optical system lends itself to clinical translation due to high-fluorescence sensitivity, simplicity, and the ability to multiplex several pathological molecular imaging targets simultaneously.
Assuntos
Processamento de Imagem Assistida por Computador/métodos , Pulmão/citologia , Pulmão/microbiologia , Microscopia de Fluorescência/métodos , Imagem Molecular/métodos , Aspergillus fumigatus/química , Líquido da Lavagem Broncoalveolar/microbiologia , Desenho de Equipamento , Humanos , Monócitos/citologia , Neutrófilos/citologia , Pseudomonas aeruginosa/químicaRESUMO
We describe the fringe-packet tracking system used to equalize the optical path lengths at the Infrared Optical Telescope Array interferometer. The measurement of closure phases requires obtaining fringes on three baselines simultaneously. This is accomplished by use of an algorithm based on double Fourier interferometry for obtaining the wavelength-dependent phase of the fringes and a group-delay tracking algorithm for determining the position of the fringe packet. A comparison of data acquired with and without the fringe-packet tracker shows a factor of approximately 3 reduction of the error in the closure-phase measurement. The fringe-packet tracker has been able so far to track fringes with signal-to-noise ratios as low as 1.8 for stars as faint as mH = 7.0.