Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
1.
Europace ; 26(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38530796

RESUMO

AIMS: Slow conduction (SC) anatomical isthmuses (AIs) are the dominant substrate for monomorphic ventricular tachycardia (VT) in patients with repaired tetralogy of Fallot (rTF). This study aimed to evaluate the utility of automated propagational analysis for the identification of SC-AI in patients with rTF. METHODS AND RESULTS: Consecutive rTF patients undergoing VT substrate characterization were included. Automated isochronal late activation maps (ILAM) were obtained with multielectrode HD Grid Catheter. Identified deceleration zones (DZs) were compared with both SC-AI defined by conduction velocity (CV) (<0.5 m/s) and isthmuses of induced VT for mechanistic correlation. Fourteen patients were included (age 48; p25-75 35-52 years; 57% male), 2 with spontaneous VT and 12 for risk stratification. Nine VTs were inducible in seven patients. Procedure time was 140 (p25-75 133-180) min and mapping time 29.5 (p25-75 20-37.7) min, using a median of 2167 points. All the patients had at least one AI by substrate mapping, identifying a total of 27 (11 SC-AIs). Isochronal late activation maps detected 10 DZs mostly in the AI between ventricular septal defect and pulmonary valve (80%). Five patients had no DZs. A significant negative correlation between number of isochrones/cm and CV was observed (rho -0.87; P < 0.001). Deceleration zones correctly identified SC-AI (90% sensitivity; 100% specificity; 0.94 accuracy) and was related to VT inducibility (P = 0.006). Deceleration zones co-localized to the critical isthmus of induced VTs in 88% of cases. No complications were observed. CONCLUSION: Deceleration zones displayed by ILAM during sinus rhythm accurately identify SC-AIs in rTF patients allowing a safe and short-time VT substrate characterization procedure.


Assuntos
Ablação por Cateter , Valva Pulmonar , Taquicardia Ventricular , Tetralogia de Fallot , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Tetralogia de Fallot/cirurgia , Frequência Cardíaca/fisiologia , Arritmias Cardíacas , Ablação por Cateter/efeitos adversos
2.
Eur Heart J ; 42(5): 508-516, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33279955

RESUMO

AIM: The benefit of cardiac pacing in patients with severe recurrent reflex syncope and asystole induced by tilt testing has not been established. The usefulness of tilt-table test to select candidates for cardiac pacing is controversial. METHODS AND RESULTS: We randomly assigned patients aged 40 years or older who had at least two episodes of unpredictable severe reflex syncope during the last year and a tilt-induced syncope with an asystolic pause longer than 3 s, to receive either an active (pacing ON; 63 patients) or an inactive (pacing OFF; 64 patients) dual-chamber pacemaker with closed loop stimulation (CLS). The primary endpoint was the time to first recurrence of syncope. Patients and independent outcome assessors were blinded to the assigned treatment. After a median follow-up of 11.2 months, syncope occurred in significantly fewer patients in the pacing group than in the control group [10 (16%) vs. 34 (53%); hazard ratio, 0.23; P = 0.00005]. The estimated syncope recurrence rate at 1 year was 19% (pacing) and 53% (control) and at 2 years, 22% (pacing) and 68% (control). A combined endpoint of syncope or presyncope occurred in significantly fewer patients in the pacing group [23 (37%) vs. 40 (63%); hazard ratio, 0.44; P = 0.002]. Minor device-related adverse events were reported in five patients (4%). CONCLUSION: In patients aged 40 years or older, affected by severe recurrent reflex syncope and tilt-induced asystole, dual-chamber pacemaker with CLS is highly effective in reducing the recurrences of syncope. Our findings support the inclusion of tilt testing as a useful method to select candidates for cardiac pacing. STUDY REGISTRATION: ClinicalTrials.gov identifier NCT02324920, Eudamed number CIV-05-013546.


Assuntos
Estimulação Cardíaca Artificial , Parada Cardíaca , Adulto , Parada Cardíaca/etiologia , Parada Cardíaca/terapia , Humanos , Reflexo , Síncope/etiologia , Síncope/terapia , Teste da Mesa Inclinada , Resultado do Tratamento
3.
J Cardiovasc Electrophysiol ; 32(10): 2785-2790, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34411358

RESUMO

SCN5A gene variants are associated with both Brugada syndrome and conduction disturbances, sometimes expressing an overlapping phenotype. Functional consequences of SCN5A variants assessed by patch-clamp electrophysiology are particularly beneficial for correct pathogenic classification and are related to disease penetrance and severity. Here, we identify a novel SCN5A loss of function variant, p.1449Y>H, which presented with high penetrance and complete left bundle branch block, totally masking the typical findings on the electrocardiogram. We highlight the possibility of this overlap combination that makes impossible an electrocardiographic diagnosis and, through a functional analysis, associate the p.1449Y>H variant to SCN5A pathogenicity.


Assuntos
Síndrome de Brugada , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/genética , Eletrocardiografia , Humanos , Mutação , Canal de Sódio Disparado por Voltagem NAV1.5/genética
4.
Eur J Clin Invest ; 51(12): e13633, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34148231

RESUMO

BACKGROUND: Several scores to identify patients at high risk of suffering atrial fibrillation have been developed. Their applicability in hypertensive diabetic patients, however, remains uncertain. Our aim is to develop and validate a diagnostic predictive model to calculate the risk of developing atrial fibrillation at five years in a hypertensive diabetic population. METHODS: The derivation cohort consisted of patients with both hypertension and diabetes attended in any of the 52 primary healthcare centres of Barcelona; the validation cohort came from the 11 primary healthcare centres of Terres de l'Ebre (Catalonia South) from January 2013 to December 2017. Multivariable Cox regression identified clinical risk factors associated with the development of atrial fibrillation. The overall performance, discrimination and calibration of the model were carried out. RESULTS: The derivation data set comprised 54 575 patients. The atrial fibrillation rate incidence was 15.3 per 1000 person/year. A 5-year predictive model included age, male gender, overweight, heart failure, valvular heart disease, peripheral vascular disease, chronic kidney disease, number of antihypertensive drugs, systolic and diastolic blood pressure, heart rate, thromboembolism, stroke and previous history of myocardial infarction. The discrimination of the model was good (c-index = 0.692; 95% confidence interval, 0.684-0.700), and calibration was adequate. In the validation cohort, the discrimination was lower (c-index = 0.670). CONCLUSIONS: The model accurately predicts future atrial fibrillation in a population with both diabetes and hypertension. Early detection allows the prevention of possible complications arising from this disease.


Assuntos
Fibrilação Atrial/epidemiologia , Regras de Decisão Clínica , Diabetes Mellitus/epidemiologia , Hipertensão/epidemiologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/uso terapêutico , Feminino , Insuficiência Cardíaca/epidemiologia , Frequência Cardíaca , Doenças das Valvas Cardíacas/epidemiologia , Humanos , Hipertensão/tratamento farmacológico , Masculino , Pessoa de Meia-Idade , Obesidade/epidemiologia , Doenças Vasculares Periféricas/epidemiologia , Modelos de Riscos Proporcionais , Fatores Sexuais , Acidente Vascular Cerebral/epidemiologia
5.
Europace ; 23(8): 1285-1294, 2021 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-33846728

RESUMO

AIMS: To assess potential benefits of a local activation time (LAT) automatic acquisition protocol using wavefront annotation plus an ECG pattern matching algorithm [automatic (AUT)-arm] during premature ventricular complex (PVC) ablation procedures. METHODS AND RESULTS: Prospective, randomized, controlled, and international multicentre study (NCT03340922). One hundred consecutive patients with indication for PVC ablation were enrolled and randomized to AUT (n = 50) or manual (MAN, n = 50) annotation protocols using the CARTO3 navigation system. The primary endpoint was mapping success. Clinical success was defined as a PVC-burden reduction of ≥80% in the 24-h Holter within 6 months after the procedure. Mean age was 56 ± 14 years, 54% men. The mean baseline PVC burden was 25 ± 13%, and mean left ventricular ejection fraction (LVEF) 55 ± 11%. Baseline characteristics were similar between the groups. The most frequent PVC-site of origin were right ventricular outflow tract (41%), LV (25%), and left ventricular outflow tract (17%), without differences between groups. Radiofrequency (RF) time and number of RF applications were similar for both groups. Mapping and procedure times were significantly shorter in the AUT-arm (25.5 ± 14.3 vs. 32.8 ± 12.6 min, P = 0.009; and 54.8 ± 24.8 vs. 67.4 ± 25.2, P = 0.014, respectively), while more mapping points were acquired [136 (94-222) AUT vs. 79 (52-111) MAN; P < 0.001]. Mapping and clinical success were similar in both groups. There were no procedure-related complications. CONCLUSION: The use of a complete automatic protocol for LAT annotation during PVC ablation procedures allows to achieve similar clinical endpoints with higher procedural efficiency when compared with conventional, manual annotation carried out by expert operators.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Adulto , Idoso , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
6.
Pacing Clin Electrophysiol ; 42(6): 678-685, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30912154

RESUMO

BACKGROUND: Interlesion distance and ablation index (AI) have been proposed as parameters of radiofrequency (RF) lesion durability. This study analyzes the relationship between RF parameters of automatically acquired lesion tags and late reconnections in repeat pulmonary vein isolation (PVI) procedures. METHODS: One hundred fifty-seven patients underwent contact force (CF)-guided PVI with automatic acquisition of RF lesions. During follow-up, 21 patients underwent a repeat PVI procedure. The relationship between RF parameters (power, CF, impedance drop, and AI) of the initial PVI procedure and reconnections observed at repeat PVI was analyzed. Visual gap was defined as the existence of a discontinuity between two RF lesions automatically acquired in the initial PVI procedure. Regional values of AI associated with lesion durability were identified. RESULTS: Twenty-one patients were included. Three hundred thirty-six segments and 2507 RF lesions were analyzed. The median interval between the initial and repeat PVI procedures was 17 (11-24) months. All patients showed ≥1 reconnected segment. Sixty-three segments (18.7%) were reconnected. Reconnected segments showed visual gaps more frequently than non-reconnected segments (66.6% vs 17.6%; P < .001; negative predictive value 91.4%). The mean distance of visual gaps was 8 ± 2.8 mm. No differences were observed in power (31.4 ± 4.7 W vs 31 ± 4.1 W; P = .573), CF (14.4 ± 5.3 g vs 15.4 ± 5.4 g; P = .315), and impedance drop (6.9 ± 5.2 ohms vs 6.5 ± 3.8 ohms; P = .576) between reconnected and non-reconnected segments. Among segments without visual gap, the minimum AI value was significantly higher in the non-reconnected segments (325 ± 96.1 vs 204.7 ± 78.5; P < .001). No reconnections were observed in segments without visual gap and minimum AI ≥ 330/220 in anterior/posterior wall, respectively. CONCLUSIONS: Contiguity between automatically acquired RF lesions and minimum AI value are the main determinants of long-term PVI durability.


Assuntos
Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Radiofrequência/métodos , Fibrilação Atrial/fisiopatologia , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Reoperação
7.
Europace ; 20(FI2): f171-f178, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29106546

RESUMO

Aims: Current navigation systems incorporate algorithms for automatic identification of local activation time (LAT). However, data about their utility and accuracy in premature ventricular complex (PVC) ablation procedures are scarce. This study analyses the accuracy of an algorithmic method based on automatic annotation of the maximal negative slope of the unipolar electrogram within the window demarcated by the bipolar electrogram compared with conventional manual annotation during PVC ablation procedures. Methods and results: Forty patients with successful ablation of focal PVC in three centres were included. Electroanatomical activation maps obtained with the automatic system (WF-map) were compared with manual annotation maps (M-map). Correlation and concordance of LAT obtained with both methods were assessed at 3536 points. The distance between the earliest activation site (EAS) and the effective radiofrequency application point (e-RFp) were determined in M-map and WF-map. The distance between WF-EAS and M-EAS was assessed. Successful ablation sites included left ventricular outflow tract (LVOT; 55%), right ventricular outflow tract (40%), and tricuspid annulus (5%). Good correlation was observed between the two annotation approaches (r = 0.655; P < 0.0001). Bland-Altman analysis revealed a systematic delayed detection of LAT by WF-map (bias 33.8 ± 30.9 ms), being higher in LVOT than in the right ventricle (42.6 ± 29.2 vs. 27.2 ± 30.5 ms, respectively; P < 0.0001). No difference in EAS-eRFp distance was observed between M-map and WF-map (1.8 ± 2.8 vs. 1.8 ± 3.4 mm, respectively; P = 0.986). The median (interquartile range) distance between WF-EAS and M-EAS was 2.2(0-6) mm. Conclusion: Good correlation was found between M-map and WF-map. Local activation time detection was systematically delayed in WF-map, especially in LVOT. Accurate identification of e-RFp was achieved with both annotation approaches.


Assuntos
Potenciais de Ação , Algoritmos , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Frequência Cardíaca , Processamento de Sinais Assistido por Computador , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Espanha , Fatores de Tempo , Resultado do Tratamento , Complexos Ventriculares Prematuros/fisiopatologia
8.
Europace ; 19(4): 607-616, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28431051

RESUMO

BACKGROUND: First-line endoepicardial ventricular tachycardia (VT) ablation has been proposed for patients with arrhythmogenic cardiomyopathy (AC). This study reports procedural safety, outcomes, and predictors of recurrence. METHODS AND RESULTS: Forty-one consecutive patients [12 with left ventricle (LV) involvement, 7 left-dominant] underwent first-line endoepicardial VT substrate ablation. Standard bipolar and unipolar thresholds were used to define low-voltage areas (LVA). Arrhythmogenic substrate area (ASA) was defined as the area containing electrograms with delayed components. Implantable cardioverter defibrillator interrogations were evaluated for VT recurrence. Epicardial LVA was larger in all cases (102.5 ± 78.6 vs. 19.3 ± 24.4 cm2; P< 0.001). Consistent with an epicardium-to-endocardium arrhythmogenic substrate progression pattern, epicardial ASA (epi-ASA) was negatively correlated with bipolar endocardial LVA (r = -0.368; P= 0.035) and with endocardial bipolar/unipolar-LVA (Bi/Uni-LVA) ratio (r= -0.38; P= 0.037). A Bi/Uni-LVA ratio >0.23 predicted an epi-ASA ≤10 cm2 (100% sensitivity, 84% specificity). Patients showing an epi-ASA < 10 cm2 required less epicardial (8.4 ± 5.8 vs. 25.3 ± 16; P= 0.045) and more endocardial (16.5 ± 8.6 vs. 7.5 ± 8.2; P= 0.047) radiofrequency applications. One patient with epi-ASA < 10 cm2 died of cardiac tamponade after epicardial puncture. Acute success (no VT inducibility after procedure) was achieved in 36 patients (90%). After 32.2 ± 21.8 months, 11 (26.8%) patients had VT recurrences. Left-dominant AC was associated with an increased risk of recurrence (HR = 3.41 [1.1-11.2], P= 0.044; log-rank P= 0.021). CONCLUSION: First-line endoepicardial VT substrate ablation achieves good long-term results in AC. Left-dominant AC is associated with an increased risk of recurrence. The Bi/Uni-LVA ratio identifies patients with limited epicardial arrhythmogenic substrate in whom the indication of epicardial approach should be more cautiously assessed.


Assuntos
Displasia Arritmogênica Ventricular Direita/mortalidade , Displasia Arritmogênica Ventricular Direita/cirurgia , Ablação por Cateter/mortalidade , Ablação por Cateter/estatística & dados numéricos , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/prevenção & controle , Adulto , Displasia Arritmogênica Ventricular Direita/diagnóstico , Causalidade , Terapia Combinada/mortalidade , Terapia Combinada/estatística & dados numéricos , Comorbidade , Endocárdio/cirurgia , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Pericárdio/cirurgia , Prevalência , Recidiva , Fatores de Risco , Prevenção Secundária/estatística & dados numéricos , Espanha/epidemiologia , Taxa de Sobrevida , Taquicardia Ventricular/diagnóstico , Resultado do Tratamento
10.
Pacing Clin Electrophysiol ; 39(4): 361-9, 2016 04.
Artigo em Inglês | MEDLINE | ID: mdl-26768692

RESUMO

BACKGROUND: The impact of contact force (CF) monitoring in pulmonary vein (PV) isolation after a circumferential anatomic ablation (CAA) is unknown. We analyze the usefulness of CF monitoring in acute PV isolation and procedure parameters using a CAA. METHODS: Fifty patients with paroxysmal atrial fibrillation were randomized into CF-on (CF >10 grams; n = 25) or CF-off (CF blinded; n = 25) groups. We performed a first round of CAA with a ThermoCool(®) SmartTouch(®) catheter blinded to the LASSO(®) catheter (Biosense Webster, Diamond Bar, CA, USA), with radiofrequency (RF) lesions tagged with the VisiTag(™) Module. After the CAA, each PV was reviewed with the LASSO(®) catheter recording the segments with gaps. RESULTS: All the PVs were isolated with a CAA in 20 patients of the CF-on versus eight of the CF-off (P = 0.001). Of the 45 segments with gaps in the left PVs, 38 were from the CF-off (P = 0.0001). Of the eight segments with gaps in the right PVs, seven were from the CF-off (P = 0.06). The CF in the left PVs was higher in the CF-on (16.3 ± 3.2 grams vs 10.5 ± 4.3 grams; P = 0.0001) and similar in the right PVs (17.6 ± 3.6 grams vs 15.2 ± 5.3 grams; P = 0.08). All of the gaps were closed with additional RF LASSO(®) -guided touch-up. Procedure and fluoroscopy times were shorter in the CF-on (139 ± 24 minutes vs 157 ± 32 minutes and 20 ± 6 minutes vs 24 ± 7 minutes; both P = 0.039). At 12 months the patients free of AF recurrence was 84% CF-on versus 75% CF-off (log-rank P = 0.4) [corrected]. CONCLUSIONS: In paroxysmal atrial fibrillation, a CAA guided by CF reduces PV gaps and shortens the procedure parameters at the expense of the left PVs.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/instrumentação , Ablação por Cateter/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Adolescente , Adulto , Idoso , Fibrilação Atrial/patologia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/instrumentação , Desenho de Equipamento , Feminino , Sistema de Condução Cardíaco/patologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Sistemas Homem-Máquina , Pessoa de Meia-Idade , Monitorização Intraoperatória/instrumentação , Monitorização Intraoperatória/métodos , Veias Pulmonares/patologia , Estresse Mecânico , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento , Adulto Jovem
11.
Pacing Clin Electrophysiol ; 38(2): 216-24, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25534124

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) causes a reduction in left atrium size that is attributable to reverse atrial remodeling (RAR). The objective of this study was to identify predictors of RAR and determine its association with other parameters of improvement in cardiac function. METHODS: It is a prospective study with 74 patients (52 ± 9 years old, 81% male), and 51% of patients had paroxysmal atrial fibrillation. Patients were serially assessed with transthoracic echocardiography; plasma N-terminal B-type natriuretic peptide (NT-proBNP); and high-sensitivity C-reactive protein levels at baseline and 3, 6, and 12 months following the PVI. RAR was defined as a reduction in the left atrial volume index (LAV-index) >10% from baseline at the end of follow-up. A multivariate analysis was conducted to identify predictors of RAR. RESULTS: The LAV-index decreased significantly during follow-up in the entire population (P = 0.0005). RAR (experienced by 63.5% of the patients) was more frequent (76% vs. 42%; P = 0.004) and pronounced (reduction 16.65 ± 14% vs. 8 ± 14%; P = 0.015) in patients with a successful ablation (46 of 74 patients, 62.2%). Only patients with RAR showed significant improvement in NT-proBNP levels (P = 0.0001), systolic function (P = 0.035), and diastolic function (P = 0.005). Multivariable analysis revealed that a successful ablation (odds ratio [OR] = 4.6; 95% confidence interval [CI] 1.46-14.68; P = 0.009), LAV-index (OR = 1.15; 95% CI 1.03-1.2; P = 0.021), and patient's body mass index (OR = 0.84; 95% CI 0.74-0.96; P = 0.012) were independent predictors of RAR. CONCLUSIONS: Successful PVI ablation is the main predictor of RAR that is associated with other parameters of improvement in cardiac function. The patient's body mass index may have a negative effect on RAR.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Remodelamento Atrial , Índice de Massa Corporal , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Ablação por Cateter/métodos , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Resultado do Tratamento
12.
Front Physiol ; 15: 1331852, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38818521

RESUMO

Cardiac arrhythmias cause depolarization waves to conduct unevenly on the myocardial surface, potentially delaying local components with respect to a previous beat when stimulated at faster frequencies. Despite the diagnostic value of localizing the distinct local electrocardiogram (EGM) components for identifying regions with decrement-evoked potentials (DEEPs), current software solutions do not perform automatic signal quantification. Electrophysiologists must manually measure distances on the EGM signals to assess the existence of DEEPs during pacing or extra-stimuli protocols. In this work, we present a deep learning (DL)-based algorithm to identify decrement in atrial components (measured in the coronary sinus) with respect to their ventricular counterparts from EGM signals, for disambiguating between accessory pathways (APs) and atrioventricular re-entrant tachycardias (AVRTs). Several U-Net and W-Net neural networks with different configurations were trained on a private dataset of signals from the coronary sinus (312 EGM recordings from 77 patients who underwent AP or AVRT ablation). A second, separate dataset was annotated for clinical validation, with clinical labels associated to EGM fragments in which decremental conduction was elucidated. To alleviate data scarcity, a synthetic data augmentation method was developed for generating EGM recordings. Moreover, two novel loss functions were developed to minimize false negatives and delineation errors. Finally, the addition of self-attention mechanisms and their effect on model performance was explored. The best performing model was a W-Net model with 6 levels, optimized solely with the Dice loss. The model obtained precisions of 91.28%, 77.78% and of 100.0%, and recalls of 94.86%, 95.25% and 100.0% for localizing local field, far field activations, and extra-stimuli, respectively. The clinical validation model demonstrated good overall agreement with respect to the evaluation of decremental properties. When compared to the criteria of electrophysiologists, the automatic exclusion step reached a sensitivity of 87.06% and a specificity of 97.03%. Out of the non-excluded signals, a sensitivity of 96.77% and a specificity of 95.24% was obtained for classifying them into decremental and non-decremental potentials. Current results show great promise while being, to the best of our knowledge, the first tool in the literature allowing the delineation of all local components present in an EGM recording. This is of capital importance at advancing processing for cardiac electrophysiological procedures and reducing intervention times, as many diagnosis procedures are performed by comparing segments or late potentials in subsequent cardiac cycles.

13.
Indian J Thorac Cardiovasc Surg ; 40(Suppl 1): 138-149, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38827540

RESUMO

Introduction: Infections in cardiac implantable electronic devices (CIED) are increasing over time and associated with substantially mortality and healthcare costs. The best approach is the complete removal of the system by transvenous lead extraction (TLE). However, when leads are more than 10 years old, this technique requires considerable expertise and failures with the result of abandoned leads or serious complications may occur. The aim of this study is to describe our experience using virtual and mixed reality in the preoperative planning of complex cases. Patients and methods: Consecutive patients from a referral centre with CIED infections in which TLE was judged difficult. Synchronized computed tomography (CT) scan images were processed and transferred to a fully immersive virtual reality room and also to the operative room (mixed reality) for better guidance during the extracting procedure. Results: Ten patients (seven with local and three with systemic infections) were preoperative evaluated. Processed images and virtual reality showed intense adherences of the leads to the veins, right ventricle, and right atrium endocardium and between them that preclude a difficult extraction and required a carefully planning and sometimes a different technical approach. The anticipated difficulty was confirmed by the higher times of fluoroscopy. All leads were extracted and no complications were registered. Conclusions: Preoperative planning is essential for evaluation of TLE difficulty and prevention of unexpected situations. Virtual reality seems an estimable aid for operators in planning difficult cases and also an excellent tool for teaching. Supplementary information: The online version contains supplementary material available at 10.1007/s12055-023-01663-9.

14.
J Cardiovasc Electrophysiol ; 24(10): 1075-82, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23790041

RESUMO

AIMS: Data on the success rate of ablation in atrial fibrillation (AF) are controversial. Our hypothesis is that the efficacy must be evaluated considering the AF burden (AFB) before the procedure. Moreover, the clinical significance of early recurrence (ERAT) of AF or atrial tachyarrhythmias (AT) is debatable. The aim is to describe the outcome of pulmonary vein isolation in paroxysmal AF through a subcutaneous cardiac monitor (ICM) implanted before the procedure. METHODS: Using CARTO 3, circumferential lesions around the pulmonary veins were placed. The study endpoint was the first documented recurrence of AF/AT by ICM after the blanking period (3 months). AFB (percentage of time in AF/AT) was collected every month before and after the procedure during the 12-month follow-up. RESULTS: The ICM was implanted 94 ± 23 days before the procedure in 35 patients with paroxysmal AF (54 ± 11 years, refractory to 1.8 ± 0.6 antiarrhythmic drugs). Cumulative AFB before the procedure and after the blanking period was 2.5% (1-5%) versus 0% (0-0.25%), P < 0.001. Twenty patients (57.1%) were free of documented AF/AT recurrence, 5 patients (14.2%) reduced the AFB 90%, 6 patients (17.1%) continued the same, and 4 patients (11.4%) increased the AFB 90% for AT. The success rate with second procedure was 71.4%. All 13 patients with ERAT had recurrence after the blanking period. CONCLUSIONS: The outcome of pulmonary vein isolation in patients with paroxysmal AF is well documented by an ICM. The success rate is dependent of the previous AFB that can be randomly variable and lower than expected. ERATs predict late recurrence.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Eletrocardiografia/instrumentação , Frequência Cardíaca , Veias Pulmonares/cirurgia , Telemetria/instrumentação , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Intervalo Livre de Doença , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Risco , Índice de Gravidade de Doença , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
15.
J Interv Card Electrophysiol ; 66(9): 1979-1988, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36877415

RESUMO

BACKGROUND: Catheter ablation is recommended as first-line therapy for patients with symptomatic typical AFl. Although the conventional multi-catheter approach is the standard of care for cavotricuspid isthmus (CTI) ablation, a single-catheter approach was recently described as a feasible alternative. The present study sought to compare safety, efficacy, and efficiency of single vs. multi-catheter approach for atrial flutter (AFl) ablation. METHODS: In this randomized multi-center study, consecutive patients referred for AFl ablation (n = 253) were enrolled and randomized to multiple vs. single-catheter approach for CTI ablation. In the single-catheter arm, PR interval (PRI) on the surface ECG was used to prove CTI block. Procedural and follow-up data were collected and compared between the two arms. RESULTS: 128 and 125 patients were assigned to the single-catheter and to the multi-catheter arms, respectively. In the single-catheter arm, procedure time was significantly shorter (37 ± 25 vs. 48 ± 27 minutes, p = 0.002) and required less fluoroscopy time (430 ± 461 vs. 712 ± 628 seconds, p < 0.001) and less radiofrequency time (428 ± 316 vs. 643 ± 519 seconds, p < 0.001), achieving a higher first-pass CTI block rate (55 (45%) vs. 37 (31%), p = 0.044), compared with the multi-catheter arm. After a median follow-up of 12 months, 11 (4%) patients experienced AFl recurrences (5 (4%) in the single-catheter arm and 6 (5%) in the multi-catheter arm, p = 0.99). No differences were found in arrhythmia-free survival between arms (log-rank = 0.71). CONCLUSIONS: The single-catheter approach for typical AFl ablation is not inferior to the conventional multiple-catheter approach, reducing procedure, fluoroscopy, and radiofrequency time.


Assuntos
Flutter Atrial , Ablação por Cateter , Humanos , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Catéteres
16.
Pacing Clin Electrophysiol ; 35(10): e293-5, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21091748

RESUMO

We describe a case of ablation of atrioventricular nodal reentrant tachycardia in a patient with tricuspid atresia and L-malposition of great vessels using an electroanatomical mapping system integrated with cardiac magnetic resonance imaging. Atrial activation mapping during tachycardia identified the retrograde fast pathway proximal to the His bundle, observed in the left interatrial septum. Ablation was successfully completed below this area. Map integration with the patient's anatomy allowed a safe, individualized procedure.


Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Atresia Tricúspide/cirurgia , Adolescente , Septo Interatrial/fisiopatologia , Septo Interatrial/cirurgia , Fascículo Atrioventricular/fisiopatologia , Fascículo Atrioventricular/cirurgia , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Técnica de Fontan , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Imageamento por Ressonância Magnética , Masculino , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Transposição dos Grandes Vasos/fisiopatologia , Transposição dos Grandes Vasos/cirurgia , Resultado do Tratamento , Atresia Tricúspide/fisiopatologia
17.
PLoS One ; 17(8): e0273571, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35998199

RESUMO

BACKGROUND AND OBJECTIVE: AFRICAT is a prospective cohort study intending to develop an atrial fibrillation (AF) screening program through the combination of blood markers, rhythm detection devices, and long-term monitoring in our community. In particular, we aimed to validate the use of NT-proBNP, and identify new blood biomarkers associated with AF. Also, we aimed to compare AF detection using various wearables and long-term Holter monitoring. METHODS: 359 subjects aged 65-75 years with hypertension and diabetes were included in two phases: Phase I (n = 100) and Phase II (n = 259). AF diagnosis was performed by baseline 12-lead ECG, 4 weeks of Holter monitoring (NuuboTM), and/or medical history. An aptamer array including 1310 proteins was measured in the blood of 26 patients. Candidates were selected according to p-value, logFC and biological function to be tested in verification and validation phases. Several screening devices were tested and compared: AliveCor, Watch BP, MyDiagnostick and Fibricheck. RESULTS: AF was present in 34 subjects (9.47%). The aptamer array revealed 41 proteins with differential expression in AF individuals. TIMP-2 and ST-2 were the most promising candidates in the verification analysis, but none of them was further validated. NT-proBNP (log-transformed) (OR = 1.934; p<0.001) was the only independent biomarker to detect AF in the whole cohort. Compared to an ECG, WatchBP had the highest sensitivity (84.6%) and AUC (0.895 [0.780-1]), while MyDiagnostick showed the highest specificity (97.10%). CONCLUSION: The inclusion and monitoring of a cohort of primary care patients for AF detection, together with the testing of biomarkers and screening devices provided useful lessons about AF screening in our community. An AF screening strategy using rhythm detection devices and short monitoring periods among high-risk patients with high NT-proBNP levels could be feasible.


Assuntos
Fibrilação Atrial , Biomarcadores , Eletrocardiografia Ambulatorial , Humanos , Estudos Prospectivos , Espanha
18.
Front Cardiovasc Med ; 9: 908053, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35859587

RESUMO

Background: Atrial fibrillation (AF) increases the risk of ischemic stroke in asymptomatic individuals and may be the underlying cause of many cryptogenic strokes. We aimed to test the usefulness of candidate blood-biomarkers related to AF pathophysiology in two prospective cohorts representative of those populations. Methods: Two hundred seventy-four subjects aged 65-75 years with hypertension and diabetes from the AFRICAT cohort, and 218 cryptogenic stroke patients aged >55 years from the CRYPTO-AF cohort were analyzed. AF was assessed by 4 weeks of monitoring with a wearable Holter device (NuuboTM™). Blood was collected immediately before monitoring started. 10 candidate biomarkers were measured by automated immunoassays (Roche, Penzberg) in the plasma of all patients. Univariate and logistic regression analyses were performed in each cohort separately. Results: Atrial fibrillation detection rate was 12.4% (AFRICAT cohort) and 22.9% (CRYPTO-AF cohort). 4 biomarkers were significantly increased in asymptomatic individuals with AF [Troponin-T, Angiopoietin-2 (Ang-2), Endocan, and total N-terminal pro-B type natriuretic peptide (NT-proBNP)] and 7 biomarkers showed significantly higher concentrations in cryptogenic stroke patients with AF detection [growth differentiation factor 15, interleukin 6, Troponin-T, Ang-2, Bone morphogenic protein 10, Dickkopf-related protein 3 (DKK-3), and total NT-proBNP]. The models including Ang-2 and total NT-proBNP [AUC 0.764 (0.665-0.863)], and Ang-2 and DKK-3 [AUC = 0.733 (0.654-0.813)], together with age and sex, showed the best performance to detect AF in high-risk asymptomatic individuals, and in cryptogenic stroke patients, respectively. Conclusion: Blood-biomarkers, in particular, total NT-proBNP, DKK-3, and Ang-2, were associated with AF reflecting two mechanistically different pathways involved in AF pathophysiology (AF stretch and vascular changes). The combination of these biomarkers could be useful in AF screening strategies in the primary care setting and also for searching AF after cryptogenic stroke.

19.
Heart Rhythm ; 18(10): 1709-1716, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34029733

RESUMO

BACKGROUND: Pacemapping (PM) is a useful maneuver for aiding premature ventricular complex (PVC) ablation. Its standalone clinical value is still to be defined. OBJECTIVES: The purpose of this study was to analyze the efficacy of a predefined PM protocol for low-burden PVC ablation, regardless of their site of origin (SOO) and the presence of structural heart disease. METHODS: This was a prospective, nonrandomized, multicenter study. The PM protocol was performed when <1 PVC/min was found. The "target area" was delimited by the 3 best matching points >94% correlation, and 3 radiofreqency (RF) applications were delivered. RESULTS: Of 185 patients, 105 (57%) underwent activation mapping, 60 (32%) were PM-guided, and 20 (11%) were canceled due to absence of PVCs. Baseline QRS, PVC burden, and outflow tract origin were independent predictors of PM-guided ablation. A higher proportion of right ventricular outflow tract SOO in the PM group (52% vs 40%; P = .03) was observed. Mean target area was 0.6 ± 0.9 cm2. Mean 10-ms isochronal area in local activation time (LAT)-guided procedures was higher (1.7 ± 2.3 cm2; P <.001). Mean number of PM matching points acquired was 39 ± 21 (range 6-98). Mean mapping and RF times were similar in both groups. However, significantly shorter procedural (53 ± 24 vs 61 ± 26 minutes; P = .04) as well as RF times (111 ± 51 vs 149 ± 149 seconds; P = .05) were needed in the PM group using the proposed protocol. Global clinical success reached 87% for the PM group and 90% (P = .58) the for LAT mapping group. CONCLUSION: When LAT mapping is precluded, application of a PM-guided ablation protocol directed to >94% matching correlation target area is a more efficient alternative with comparable clinical results.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Eletrocardiografia Ambulatorial/métodos , Ventrículos do Coração/fisiopatologia , Volume Sistólico/fisiologia , Complexos Ventriculares Prematuros/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Complexos Ventriculares Prematuros/cirurgia
20.
J Womens Health (Larchmt) ; 30(4): 596-603, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33170080

RESUMO

Background: Whether the sex factor influences the benefit of the implantable cardioverter-defibrillator (ICD) for the prevention of sudden death remains a subject of debate. Using a prospective registry, we sought to analyze the survival and time to first ICD therapy according to sex. Materials and Methods: Retrospective analysis of a prospective cohort of patients undergoing an ICD implant from 2008 to 2019. Data about time to first appropriate therapy, type of therapy administered, and incidence and causes of mortality were collected. Results: Among 756 ICD patients, 150 (19.8%) were women. Women were younger (51 ± 15 years vs. 61 ± 14 years; p < 0.001) and showed a lower rate of ischemic cardiomyopathy (23% vs. 54%; p < 0.001) and atrial fibrillation (12% vs. 19%; p = 0.05). Women had higher left ventricular ejection fraction (39% ± 17% vs. 35% ± 13%) and showed more frequently left bundle branch block (39% vs. 28%, p = 0.027). The rate of primary prevention (68% vs. 59.6%; p = 0.058) and cardiac resynchronization therapy (27% vs. 19%, p = 0.02) were higher in women. After a median follow-up of 46 months (3382 patient-years), the incidence of both the primary combined endpoint of mortality/transplant (20% vs. 29%; logrank = 0.031) and ICD therapies (27% vs. 34%; p = 0.138) were lower in women. According to the propensity score-matching analysis, no differences were observed between both sexes with respect to the incidence of mortality/transplant (24.8% vs. 28.6%; logrank = 0.88), ICD therapies (28% vs. 27%; logrank = 0.17), and main cause of death (heart failure [HF]). Conclusions: The clinical characteristics at the moment of ICD implant are different between sexes. After adjusting them, both sexes equally benefit from the ICD. HF is the main cause of mortality both in men and women.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa