Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Circulation ; 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38940005

RESUMO

BACKGROUND: Current estimates of atrial fibrillation (AF)-associated mortality rely on claims- or clinical-derived diagnoses of AF, limit AF to a binary entity, or are confounded by comorbidities. The objective of the present study is to assess the association between device-recognized AF and mortality among patients with cardiac implantable electronic devices capable of sensitive and continuous atrial arrhythmia detection. Secondary outcomes include relative mortality among cohorts with no AF, paroxysmal AF, persistent AF, and permanent AF. METHODS: Using the deidentified Optum Clinformatics US claims database (2015 to 2020) linked to the Medtronic CareLink database, we identified individuals with a cardiac implantable electronic device who transmitted data ≥6 months after implantation. AF burden was assessed during the first 6 months after implantation (baseline period). Subsequent mortality, assessed from claims data, was compared between patients with and those without AF, with adjustment for age, geographic region, insurance type, Charlson Comorbidity Index, and implantation year. RESULTS: Of 21 391 patients (age, 72.9±10.9 years; 56.3% male) analyzed, 7798 (36.5%) had device-recognized AF. During a mean of 22.4±12.9 months (median, 20.1 [12.8-29.7] months) of follow-up, the overall incidence of mortality was 13.5%. Patients with AF had higher adjusted all-cause mortality than patients without AF (hazard ratio, 1.29 [95% CI, 1.20-1.39]; P<0.001). Among those with AF, patients with nonparoxysmal AF had the greatest risk of mortality (persistent AF versus paroxysmal AF: hazard ratio, 1.36 [95% CI, 1.18-1.58]; P<.001; permanent AF versus paroxysmal AF: hazard ratio, 1.23 [95% CI, 1.14-1.34]; P<.001). CONCLUSIONS: After adjustment for potential confounding factors, presence of AF was associated with higher mortality than no AF in our cohort of patients with cardiac implantable electronic devices. Among those with AF, nonparoxysmal AF was associated with the greatest risk of mortality.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38965878

RESUMO

BACKGROUND: Success of atypical atrial flutter (AAFL) ablation has historically been limited by difficulty mapping the complex re-entrant circuits involved. While high-density (HD) mapping has become commonplace in clinical practice, there are limited data on outcomes of HD versus non-HD mapping for AAFL ablation. OBJECTIVE: To compare clinical outcomes and healthcare utilization using HD mapping versus non-HD mapping for AAFL ablation. METHODS: Retrospective analysis of all AAFL procedures between 2005 and 2022 at an academic medical center was conducted. Procedures utilizing a 16-electrode HD Grid catheter and Precision mapping system were compared to procedures using prior generation 10-20 electrode spiral catheters and the Velocity system (Abbott, IL). Cox regression models and Poisson regression models were utilized to examine procedural and healthcare utilization outcomes. Models were adjusted for left ventricular ejection fraction, CHA2DS2-VASc, and history of prior ablation. RESULTS: There were 108 patients (62% HD mapping) included in the analysis. Baseline clinical characteristics were similar between groups. Use of HD mapping was associated with a higher rate of AAFL circuit delineation (92.5% vs. 76%; p = .014) and a greater adjusted procedure success rate, defined as non-inducibility at procedure end, (aRR (95% CI) 1.26 (1.02-1.55) p = .035) than non-HD mapping. HD mapping was also associated with a lower rate of ED visits (aIRR (95% CI) 0.32 (0.14-0.71); p = .007) and hospitalizations (aIRR (95% CI) 0.32 (0.14-0.68); p = .004) for AF/AFL/HF through 1 year. While there was a lower rate of recurrent AFL through 1 year among HD mapping cases (aHR (95% CI) 0.60 (0.31-1.16) p = .13), statistical significance was not met likely due to the low sample size and higher rate of ambulatory rhythm monitoring in the HD group (61% vs. 39%, p = .025). CONCLUSION: Compared to non-HD mapping, AAFL ablation with HD mapping is associated with improvements in the ability to define the AAFL circuit, greater procedural success, and a reduction in the number of ED visits and hospitalization for AF/AFL/HF.

3.
J Cardiovasc Electrophysiol ; 34(10): 2152-2157, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36806796

RESUMO

Uninterrupted anticoagulation for atrial fibrillation (AF), regardless of AF burden, is deeply rooted in practice since the early anticoagulation trials. However, uninterrupted anticoagulation is not without risks, and may not be beneficial for allcomers with a history of AF. Indeed, contemporary data that support a critical duration threshold of AF that benefits from anticoagulation, and a temporal association between stroke and multihour AF episodes, compel the study of a more targeted approach to AF anticoagulation. In this review, we discuss data that support further investigation of "pill in the pocket" anticoagulation for AF, and introduce the pivotal Rhythm Evaluation for Anticoagulation Therapy for Atrial Fibrillation (REACT-AF) trial that will robustly evaluate this strategy.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Anticoagulantes/efeitos adversos
4.
Heart Fail Clin ; 19(3): 285-296, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37230644

RESUMO

This review discusses the contemporary clinical evaluation and management of patients with comorbid aortic regurgitation (AR) and heart failure (HF) (AR-HF). Importantly, as clinical HF exists along the spectrum of AR severity, the present review also details novel strategies to detect early signs of HF before the clinical syndrome ensues. Indeed, there may be a vulnerable cohort of AR patients who benefit from early detection and management of HF. Additionally, while the mainstay of operative management for AR has historically been surgical aortic valve replacement, this review discusses alternate procedures that may be beneficial in high-risk cohorts.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Humanos , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 32(8): 2097-2104, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34191371

RESUMO

INTRODUCTION: Obesity is an established risk factor for recurrent atrial fibrillation (AF) after ablation. The impact of pre-procedure weight changes on freedom from AF (FFAF) after ablation in obese and nonobese patients is unknown. METHODS: A single-center retrospective cohort study of patients undergoing pulmonary vein isolation was performed. Before ablation, all candidates were encouraged to adopt healthy lifestyle habits according to American Heart Association guidelines, including weight loss, by their physician. The primary endpoint was FFAF through 1-year after completion of the 3-month blanking period. RESULTS: Of the 601 patients (68% male; average age 62.1 ± 10.3 years) included in analysis, 234 patients (38.9%) were obese (body mass index ≥ 30) and 315 (52.4%) had paroxysmal AF. FFAF was observed in 420 patients (69.9%) at 15 months. Percent change in weight that occurred during the year before ablation independently predicted FFAF through 15-months in all patients (adjusted odds ratio = 1.17, 95% confidence interval: 1.11-1.23). Subgroup analyses based on paroxysmal vs persistent AF, presence of obesity, and history of prior ablation were performed. Percent change in weight over the year before ablation was independently associated with FFAF in all subgroups except nonobese patients with persistent AF. CONCLUSION: Pre-ablation weight loss was associated with FFAF in both obese and nonobese patients. Further studies are needed to define the optimal approach to weight loss before AF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento , Redução de Peso
6.
Curr Heart Fail Rep ; 18(3): 85-98, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33864224

RESUMO

PURPOSE OF REVIEW: This review discusses the mechanisms, clinical implications, and treatments of left atrial (LA) myopathy in comorbid atrial fibrillation (AF) and heart failure (HF) across the spectrum of ejection fraction. RECENT FINDINGS: AF and HF are highly comorbid conditions. Left atrial (LA) myopathy, characterized by impairments in LA structure, function, or electrical conduction, plays a fundamental role in the development of both AF and HF with preserved ejection fraction (AF-HFpEF) along with AF and HF with reduced ejection fraction (AF-HFrEF). While the nature of LA myopathy in AF-HFpEF is unique from that of AF-HFrEF, LA myopathy also leads to progression of both of these conditions. There may be a vulnerable cohort of AF-HF patients who have a disproportionate degree of LA myopathy compared with left ventricular (LV) dysfunction. Further investigations are required to identify therapies to improve LA function in this cohort.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Doenças Musculares , Disfunção Ventricular Esquerda , Fibrilação Atrial/complicações , Fibrilação Atrial/epidemiologia , Insuficiência Cardíaca/epidemiologia , Humanos , Volume Sistólico
7.
J Cardiovasc Electrophysiol ; 31(5): 1031-1037, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32115794

RESUMO

INTRODUCTION: Focal impulse and rotor modulation (FIRM) ablation can be used to target nonpulmonary vein (PV) sources of atrial fibrillation (AF). No published studies have compared freedom from atrial fibrillation (FFAF) after pulmonary vein reisolation (PVRI) plus FIRM to PVRI alone in patients with reconnected PVs undergoing repeat ablation. METHODS: A 3:1 matched retrospective cohort study was performed on 21 patients with recurrent AF and PV reconnection who underwent PVRI plus FIRM-guided ablation and 63 patients with recurrent AF treated with PVRI alone at a single institution. All patients in the PVRI-alone cohort had cryoballoon PVRI at the time of repeat ablation without additional lesion sets for AF. Cases were matched based on the type of AF (paroxysmal vs nonparoxysmal), left atrial diameter (±4 mm), left ventricular ejection fraction (±10%), duration of AF (±18 months), and age (±5 years). The primary endpoint was FFAF after a 3-month blanking period. RESULTS: Out of 53 total FIRM cases performed at Northwestern Memorial Hospital between 2015 and 2017, 21 patients had PVRI plus FIRM for recurrent AF with PV reconnection. These patients had an average of 3.3 ± 2.1 rotors (60% left atrial) ablated. Over a median follow-up time of 24.7 months (interquartile range, 13-36 months), patients in the PVRI-alone cohort demonstrated a higher rate of FFAF (n = 35; 55.6%) than patients in the PVRI plus FIRM-guided ablation cohort (n = 7; 33.3%) (logrank P = .049). CONCLUSION: In patients undergoing repeat ablation for AF with PV reconnection, PVRI plus FIRM did not increase FFAF compared to PVRI alone.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Técnicas Eletrofisiológicas Cardíacas , Procedimento do Labirinto , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Bases de Dados Factuais , Feminino , Frequência Cardíaca , Humanos , Masculino , Procedimento do Labirinto/efeitos adversos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
8.
Pacing Clin Electrophysiol ; 42(12): 1589-1593, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31677170

RESUMO

New atrial flutter (AFL) that arises after pulmonary vein isolation (PVI) by catheter or surgical ablation can originate from reconnection of a pulmonary vein (PV). Reisolation of PVs with cryoballoon ablation (CBA) for treatment of peri-PV AFL after Maze or PVI has not previously been reported. The present case series describes use of CBA to treat post-PVI and post-Maze PV-dependent AFL. In these cases, CBA was used to reisolate the PVs and terminate AFL without requiring additional lesion sets for treatment of AFL.


Assuntos
Flutter Atrial/cirurgia , Ablação por Cateter/instrumentação , Criocirurgia/instrumentação , Veias Pulmonares/cirurgia , Adulto , Idoso , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
Pacing Clin Electrophysiol ; 42(6): 694-704, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30912155

RESUMO

BACKGROUND: While several studies have evaluated predictors for atrial fibrillation (AF) recurrence following catheter ablation, there are limited data specific to cryoballoon ablation (CBA). METHODS: We analyzed a prospective registry of patients at a single institution who underwent CBA. Recurrence of AF (RAF) was defined as recurrence of AF by 12-month follow-up, excluding the 3-month blanking period. Univariate analysis was performed to evaluate predictors of RAF. Receiver operating characteristic analysis was used to compare and evaluate the performance of various risk scores for discriminating risk of RAF. RESULTS: There were 542 patients included in the analysis with mean age 61.3 ± 10.6 years, 67.9% male, and 51.6% paroxysmal AF (PAF). Overall, only left atrial diameter (LAD) > 40 mm and ERAF (early recurrence of AF within 0-3 month blanking period) were significant predictors of RAF. In the PAF specific subgroup, LAD > 40 mm, AF duration > 12 months, prior stroke or transient ischemic attack, ERAF, and having previously failed an antiarrhythmic drug were significant predictors of RAF. In persistent AF (PeAF) subgroup, obstructive sleep apnea (OSA) and ERAF were significant predictors of RAF. Out of clinical risk scores tested, BASEAF2 had the highest performance with area under the curve of 0.646 (95% confidence interval [0.548, 0.708]; P < .01). CONCLUSIONS: In this single-center retrospective study of CBA, we found only LAD > 40 mm and ERAF to be predictors of RAF. We identified OSA as a potential targetable risk factor in PeAF patients undergoing CBA. Out of risk scores tested for discriminating risk of RAF, BASEAF2 had the best performance.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Idoso , Antiarrítmicos/administração & dosagem , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Ataque Isquêmico Transitório/complicações , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Apneia Obstrutiva do Sono/complicações , Acidente Vascular Cerebral/complicações , Fatores de Tempo
10.
Heart Surg Forum ; 20(4): E164-E169, 2017 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-28846532

RESUMO

BACKGROUND: A previous retrospective analysis of our cardiac surgery patients showed shortened ventilation time and hospital stay among patients receiving rigid sternal fixation compared to sternal wire fixation. We performed a prospective randomized study to further investigate these outcomes and determine if rigid closure can provide reduced pain after cardiac surgery. METHODS: Patients undergoing cardiac surgery between July 2011 and May 2014 were prospectively randomized into wire closure (Group C) or rigid fixation using sternal plates (Group R) groups. Age above 80, emergency surgery, redo sternotomy, and immunosuppression were among major exclusion criteria precluding randomization.  Intubation time was recorded for all patients. Pain scores were determined daily from postoperative day 1 until day 5 at 6 a.m. using a numeric rating scale. Narcotic pain medication requirements from day 1 to 5 were collected and converted into intravenous morphine equivalents. RESULTS: Of 80 patients, 39 patients were in Group R (average age 65 ± 8; 31 male and 8 female) and 41 patients were in Group C (average age 66 ± 9; 34 male and 7 female).  Group R patients had a higher body mass index than patients in Group C (Group R: 31 ± 5; Group C: 29 ± 5; P = .04). No significant differences in the end points of intubation time and postoperative pain were observed. Conclusion: This randomized study of cardiac surgery patients showed no significant benefits of rigid fixation over conventional sternal wire closure with regard to intubation time, postoperative pain, or length of hospital stay.


Assuntos
Placas Ósseas , Fios Ortopédicos , Cardiopatias/cirurgia , Esternotomia/métodos , Esterno/cirurgia , Deiscência da Ferida Operatória/prevenção & controle , Idoso , Procedimentos Cirúrgicos Cardíacos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo
11.
J Surg Res ; 198(2): 273-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25990694

RESUMO

BACKGROUND: Although the use of cardiac extracorporeal membrane oxygenation (ECMO) is increasing in adult patients, the field lacks understanding of associated risk factors. While standard intensive care unit risk scores such as SAPS II (simplified acute physiology score II), SOFA (sequential organ failure assessment), and APACHE II (acute physiology and chronic health evaluation II), or disease-specific scores such as MELD (model for end-stage liver disease) and RIFLE (kidney risk, injury, failure, loss of function, ESRD) exist, they may not apply to adult cardiac ECMO patients as their risk factors differ from variables used in these scores. METHODS: Between 2010 and 2014, 73 ECMOs were performed for cardiac support at our institution. Patient demographics and survival were retrospectively analyzed. A new easily calculated score for predicting ECMO mortality was created using identified risk factors from univariate and multivariate analyses, and model discrimination was compared with other scoring systems. RESULTS: Cardiac ECMO was performed on 73 patients (47 males and 26 females) with a mean age of 48 ± 14 y. Sixty-four percent of patients (47/73) survived ECMO support. Pre-ECMO SAPS II, SOFA, APACHE II, MELD, RIFLE, PRESERVE, and ECMOnet scores, were not correlated with survival. Univariate analysis of pre-ECMO risk factors demonstrated that increased lactate, renal dysfunction, and postcardiotomy cardiogenic shock were risk factors for death. Applying these data into a new simplified cardiac ECMO score (minimal risk = 0, maximal = 5) predicted patient survival. Survivors had a lower risk score (1.8 ± 1.2) versus the nonsurvivors (3.0 ± 0.99), P < 0.0001. CONCLUSIONS: Common intensive care unit or disease-specific risk scores calculated for cardiac ECMO patients did not correlate with ECMO survival, whereas a new simplified cardiac ECMO score provides survival predictability.


Assuntos
Oxigenação por Membrana Extracorpórea/mortalidade , Cardiopatias/terapia , APACHE , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Philadelphia/epidemiologia , Estudos Retrospectivos , Medição de Risco/métodos
12.
JACC Clin Electrophysiol ; 10(4): 718-730, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38430088

RESUMO

BACKGROUND: Integrating patient-specific cardiac implantable electronic device (CIED)-detected atrial fibrillation (AF) burden with measures of health care cost and utilization allows for an accurate assessment of the AF-related impact on health care use. OBJECTIVES: The goal of this study was to assess the incremental cost of device-recognized AF vs no AF; compare relative costs of paroxysmal atrial fibrillation (pAF), persistent atrial fibrillation (PeAF), and permanent atrial fibrillation (PermAF) AF; and evaluate rates and sources of health care utilization between cohorts. METHODS: Using the de-identified Optum Clinformatics U.S. claims database (2015-2020) linked with the Medtronic CareLink database, CIED patients were identified who transmitted data ≥6 months postimplantation. Annualized per-patient costs in follow-up were analyzed from insurance claims and adjusted to 2020 U.S. dollars. Costs and rates of health care utilization were compared between patients with no AF and those with device-recognized pAF, PeAF, and PermAF. Analyses were adjusted for geographical region, insurance type, CHA2DS2-VASc score, and implantation year. RESULTS: Of 21,391 patients (mean age 72.9 ± 10.9 years; 56.3% male) analyzed, 7,798 (36.5%) had device-recognized AF. The incremental annualized increased cost in those with AF was $12,789 ± $161,749 per patient, driven by increased rates of health care encounters, adverse clinical events associated with AF, and AF-specific interventions. Among those with AF, PeAF was associated with the highest cost, driven by increased rates of inpatient and outpatient hospitalization encounters, heart failure hospitalizations, and AF-specific interventions. CONCLUSIONS: Presence of device-recognized AF was associated with increased health care cost. Among those with AF, patients with PeAF had the highest health care costs. Mechanisms for cost differentials include both disease-specific consequences and physician-directed interventions.


Assuntos
Fibrilação Atrial , Custos de Cuidados de Saúde , Aceitação pelo Paciente de Cuidados de Saúde , Humanos , Fibrilação Atrial/economia , Fibrilação Atrial/terapia , Masculino , Custos de Cuidados de Saúde/estatística & dados numéricos , Feminino , Idoso , Pessoa de Meia-Idade , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Estados Unidos , Desfibriladores Implantáveis/economia , Desfibriladores Implantáveis/estatística & dados numéricos , Hospitalização/economia , Hospitalização/estatística & dados numéricos , Efeitos Psicossociais da Doença , Idoso de 80 Anos ou mais
13.
J Am Heart Assoc ; 13(6): e032213, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38497480

RESUMO

BACKGROUND: Although VCAM-1 (vascular cell adhesion molecule-1) and ICAM-1 (intercellular adhesion molecule-1) have been associated with incident heart failure with preserved ejection fraction (HFpEF) and atrial fibrillation (AF), the associations of VCAM-1 and ICAM-1 with sensitive measures of cardiac structure/function are unclear. The objective of this study is to evaluate associations between VCAM-1, ICAM-1, and measures of cardiac structure and function as potential pathways through which cellular adhesion molecules promote HFpEF and AF risk. METHODS AND RESULTS: In MESA (Multi-Ethnic Study of Atherosclerosis), we evaluated the associations of circulating VCAM-1 and ICAM-1 at examination 2 (2002-2004) with measures of cardiac structure/function on cardiac magnetic resonance imaging at examination 5 (2010-2011) after multivariable adjustment. Mediation analysis of left atrial (LA) strain on the association between VCAM-1 or ICAM-1 and AF or HFpEF was also performed. Overall, 2304 individuals (63±10 years; 47% men) with VCAM-1 or ICAM-1, cardiac magnetic resonance imaging, and covariate data were included in analysis. Higher VCAM-1 and ICAM-1 were associated with lower LA peak longitudinal strain and worse global circumferential left ventricular strain but were not associated with left ventricular myocardial scar or interstitial fibrosis. Lower LA peak longitudinal strain mediated 8% (95% CI, 2-30) of the relationship between VCAM-1 and HFpEF and 9% (95% CI, 2-21) of the relationship between VCAM-1 and AF. CONCLUSIONS: Higher VCAM-1 and ICAM-1 were associated with lower LA function and left ventricular systolic function but were not associated with myocardial scar or interstitial fibrosis. VCAM-1 and ICAM-1 may promote HFpEF and AF risk through impaired LA reservoir function.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Feminino , Humanos , Masculino , Cicatriz , Molécula 1 de Adesão Intercelular , Volume Sistólico , Molécula 1 de Adesão de Célula Vascular , Pessoa de Meia-Idade , Idoso
14.
Artigo em Inglês | MEDLINE | ID: mdl-38761294

RESUMO

BACKGROUND: The use of intravenous (IV) sotalol loading following recent U.S. Food and Drug Administration (FDA) approval of a 1-day loading protocol has reduced the obligatory 3-day hospital stay for sotalol initiation when given orally. Several studies have recently demonstrated the safety and feasibility of IV loading for patients with atrial arrhythmias. However, there is a paucity of data on the feasibility and safety of IV sotalol loading for patients with ventricular arrhythmias. This study aims to assess the safety, feasibility, and length of stay (LOS) outcomes of IV sotalol loading for the prevention of ventricular arrhythmias. METHODS: A retrospective analysis was performed of all patients undergoing IV sotalol loading and oral sotalol initiation for ventricular arrhythmias, or IV sotalol loading for atrial arrhythmias between August 2021 and December 2023 at Northwestern University. Baseline characteristics, success of sotalol initiation/loading, changes in heart rate (HR) and QT/QTc, safety, and LOS were compared between patients undergoing sotalol loading/initiation for ventricular arrhythmias (IV vs. PO) and between patients undergoing IV sotalol loading for ventricular arrhythmias vs. for atrial arrhythmias. RESULTS: A total of 28 patients underwent sotalol loading/initiation for ventricular arrhythmias (N = 15 IV and N = 13 PO) and 41 patients underwent IV sotalol loading for atrial arrhythmias. Baseline characteristics of congestive heart failure history and left ventricular ejection fraction were worse in the ventricular arrhythmias group. There was no significant difference in the successful completion of IV sotalol loading for ventricular arrhythmias compared to oral sotalol initiation for ventricular arrhythmias or IV sotalol loading for atrial arrhythmias (86.7% vs. 92.3% vs. 90.2%, p = 0.88). There was a significant increase in ΔQTc following IV sotalol infusion for ventricular arrhythmias compared to following PO sotalol initiation for ventricular arrhythmias (46.4 ± 29.2 ms vs. 8.9 ± 32.6 ms, p = 0.004) and following IV sotalol infusion for atrial arrhythmias (46.4 ± 29.2 ms vs. 24.0 ± 25.1 ms, p = 0.018). ΔHR following IV sotalol infusion for ventricular arrhythmias was similar to ΔHR following PO sotalol initiation for ventricular arrhythmias and ΔHR following IV sotalol infusion for atrial arrhythmias (- 7.5 ± 8.7 bpm vs. - 8.5 ± 13.9 bpm vs. - 8.3 ± 13.2 bpm, p = 0.87). There were no significant differences in discontinuation for QTc prolongation (6.7% vs. 1.7% vs. 2.4%, p = 0.64) and bradycardia (13.3% vs. 7.7% vs. 9.8%, p = 0.88) between IV sotalol loading for ventricular arrhythmias, PO sotalol initiation for ventricular arrhythmias, and IV sotalol loading for atrial arrhythmias. There were no instances of hypotension, life-threatening ventricular arrhythmias, heart failure, or death. Length of stay was significantly shorter for IV sotalol loading compared to PO sotalol initiation for ventricular arrhythmias (1.1 ± 0.36 days vs. 4.2 ± 1.0 days, p < 0.0001). CONCLUSION: IV sotalol loading appears feasible and safe for use in ventricular arrhythmias and results in a decreased length of stay. Despite increased comorbidities and greater increase in QTc interval following IV sotalol infusion in the ventricular arrhythmias group, there were no significant differences in successful completion of loading or adverse outcomes when compared to PO sotalol initiation for ventricular arrhythmias and IV loading for atrial arrhythmias.

15.
Artigo em Inglês | MEDLINE | ID: mdl-38819347

RESUMO

BACKGROUND: Catheter ablation for atrial fibrillation (AF) including pulmonary vein isolation and possibly further substrate ablation is the most common electrophysiological procedure. Severe complications are uncommon, but their detailed assessment in a large worldwide cohort is lacking. OBJECTIVES: The aim of this study was to determine the incidence of periprocedural severe complications and to provide a detailed characterization of the diagnostic evaluation and management of these complications in patients undergoing AF ablation. METHODS: Individual patient data were collected from 23 centers worldwide. Limited data were collected for all patients who underwent catheter ablation, and an expanded series of data points were collected for patients who experienced severe complications during periprocedural follow-up. Incidence, predictors, patient characteristics, management details, and overall outcomes of patients who experienced ablation-related complications were investigated. RESULTS: Data were collected from 23 participating centers at which 33,879 procedures were performed (median age 63 years, 30% women, 71% radiofrequency ablations). The incidence of severe complications (n = 271) was low (tamponade 6.8‰, stroke 0.97‰, cardiac arrest 0.41‰, esophageal fistula 0.21‰, and death 0.21‰). Age, female sex, a dilated left atrium, procedure duration, and the use of radiofrequency energy were independently associated with the composite endpoint of all severe complications. Among patients experiencing tamponade, 13% required cardiac surgery. Ninety-three percent of patients with complications were discharged directly home after a median length of stay of 5 days (Q1-Q3: 3-7 days). CONCLUSIONS: This large worldwide collaborative study highlighted that tamponade, stroke, cardiac arrest, esophageal fistula, and death are rare after AF ablation. Older age, female sex, procedure duration, a dilated left atrium, and the use of radiofrequency energy were associated with severe complications in this multinational cohort. One in 8 patients with tamponade required cardiac surgery.

16.
Heart Rhythm ; 20(3): 407-413, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36464126

RESUMO

BACKGROUND: Since the onset of the coronavirus disease 2019 (COVID-19) pandemic, direct-to-patient, self-applied ECG patch use has substantially increased. There are limited data comparing clinic with self-applied electrocardiogram (ECG) patches. OBJECTIVE: The purpose of this study was to compare rates of ECG patch return, percentages of time patches yielded analyzable data (analyzable time), and percentages of prescribed time ECG patches were worn between clinic and self-applied ECG patches before and during COVID-19. METHODS: A retrospective analysis of patients prescribed an ECG patch during "pre-COVID" (March 1, 2019, through March 1, 2020) and "COVID" (April 4, 2020, through April 1, 2021) years was performed. ECG patch return rates, mean percentages of analyzable time, and mean percentages of prescribed wear time were compared between clinic and self-applied groups. RESULTS: Among the 29,093 ECG patch prescriptions (19% COVID self-applied), the COVID self-applied group had a lower return rate (90.8%) than did both clinic-applied groups (COVID: 97.1%; pre-COVID: 98.1%; P < .001). Among the 28,048 ECG patches (17.5% self-applied) returned for analysis, the COVID self-applied group demonstrated a lower mean percentage of analyzable time (95.9% ± 8.2%) than did both clinic-applied groups (COVID: 96.6% ± 6.6%; pre-COVID 96.6% ± 7.4%; P < .001). There were no differences in the mean percentage of prescribed wear time between groups (pre-COVID clinic-applied: 96.7% ± 34.3%; COVID clinic-applied: 97.4% ± 39.8%; COVID self-applied: 98.1% ± 52.1%; P = .09). CONCLUSION: Self-applied ECG patches were returned at a lower rate and had a statistically lower percentage of analyzable time than clinic-applied patches. However, there were no differences between groups in mean percentages of prescribed wear time, and mean percentages of analyzable time were >95% in all groups.


Assuntos
COVID-19 , Confiabilidade dos Dados , Humanos , Estudos Retrospectivos , Eletrocardiografia
17.
J Interv Card Electrophysiol ; 66(8): 1859-1865, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36754907

RESUMO

BACKGROUND: To date, few risk models have been validated to predict recurrent atrial fibrillation (AF) >1 year after ablation. The SCALE-CryoAF score was previously derived to predict very late return of AF (VLRAF) >1 year following cryoballoon ablation (CBA), with strong predictive ability. In this study, we aim to validate the SCALE-CryoAF score for VLRAF after CBA in a novel patient cohort. METHODS: Retrospective analysis of a prospectively maintained single-center database was performed. Inclusion criteria were pulmonary vein isolation using CBA 2017-2020. Exclusion criteria included prior ablation, <1-year follow-up, lack of pre-CBA echocardiogram, additional ablation lesion sets, and documented AF recurrence 90-365 days post-CBA. The area under the curve (AUC) of SCALE-CryoAF was compared to the derivation value and other established risk models. RESULTS: Among 469 CBA performed, 241 (61% male, 62.8 ±11.7 years old) cases were included in analysis. There were 37 (15.4%) patients who developed VLRAF. Patients with VLRAF had a higher SCALE-CryoAF score (VLRAF 5.4 ± 2.7; no VLRAF 3.1 ± 2.9; p<0.001). SCALE-CryoAF was linearly associated with VLRAF (y=14.35x-11.72, R2=0.99), and a score > 5 had a 32.7% risk of VLRAF. The SCALE-CryoAF risk model predicted VLRAF with an AUC of 0.74, which was similar to the derivation value (AUCderivation: 0.73) and statistically superior to MB-LATER, CHA2DS2-VASc, and CHADS2 scores. CONCLUSIONS: The current analysis validates the ability of SCALE-CryoAF to predict VLRAF after CBA in a novel patient cohort. Patients with a high SCALE-CryoAF score should be monitored closely for recurrent AF >1 year following CBA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Fatores de Risco , Ecocardiografia , Recidiva , Veias Pulmonares/cirurgia
18.
Artigo em Inglês | MEDLINE | ID: mdl-36596954

RESUMO

BACKGROUND: Subcutaneous implantable cardioverter-defibrillators (S-ICD) are an alternative to transvenous ICDs for patients without a need for cardiac pacing. Obese patients have been proposed to be at higher risk for conversion failure with S-ICDs due to subcutaneous fat underneath the device. Optimal device positioning may promote equivalent outcomes between obese and non-obese patients by minimizing the effects of excess adipose tissue. METHODS: A retrospective analysis of patients undergoing defibrillation testing at the time of S-ICD implantation was performed. The primary endpoint was the rate of successful conversion of ventricular fibrillation (VF) at the time of implant. The secondary endpoint was shock impedance. RESULTS: A total of 184 patients were included in the study. The rate of successful conversion of VF was 90.3% for obese patients (n = 72) and 96.4% for non-obese patients (n = 112) (p = 0.086). Compared to non-obese patients, obese patients had a higher mean PRAETORIAN score (78.5 ± 58.1 vs. 48.8 ± 35.5, p < 0.001) and higher measured mean impedance (82.0 ohms ± 26.5 vs. 69.8 ohms ± 19.3, p < 0.001). Patients with a PRAETORIAN score < 90 all had successful defibrillation testing regardless of BMI. CONCLUSIONS: In this study, a PRAETORIAN score < 90 was associated with a 100% success rate of defibrillation testing following S-ICD implantation regardless of patient body mass index (BMI). Thus, the impact of obesity on impedance and the risk of failed shocks may be minimized with close attention to implantation technique to achieve a low PRAETORIAN score.

19.
Heart Rhythm ; 19(9): 1405-1411, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35716857

RESUMO

BACKGROUND: Impaired quality of life due to atrial fibrillation (AF), which often includes decreased activity level, is an indication for ablation. However, the impact of ablation for AF on activity is poorly understood. OBJECTIVE: The purpose of this study was to assess the impact of ablation on activity minutes per day using continuous accelerometer data from cardiac implantable electronic devices (CIEDs). METHODS: Using the Optum® Health Record dataset (2007-2019) linked with the Medtronic CareLink® database, we identified patients who had a CIED with AF detection and accelerometer capabilities. Patients with a device that transmitted heart rhythm and activity data ≥3 months before and ≥12 months after ablation were included in analysis. The associations between ablation and activity minutes were assessed for each CIED type. RESULTS: Of 4297 eligible patients who underwent AF ablation, 409 (9.5%) (65% male; age 67.3 ± 9.8 years; 64% paroxysmal AF) were included in analysis. The average AF burden and activity minutes per day preablation were 30.9% ± 37.4% and 175 ± 99 minutes, respectively. After ablation, relative AF burden decreased by 75.1% ± 53.2% (P <.001). There was no change in activity minutes per day after ablation in the entire cohort (average change -0.10 ± 36.2 minutes; P = .96). There were also no clinically significant changes in activity minutes postablation in subgroups based on CIED, season of ablation, quartile of AF burden change, and quartile of age at the time of ablation. CONCLUSION: There were no clinically significant changes in activity minutes per day in patients with CIEDs after ablation for AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Ablação por Cateter/efeitos adversos , Eletrônica , Feminino , Coração , Humanos , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Resultado do Tratamento
20.
Diagn Microbiol Infect Dis ; 99(4): 115272, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33388572

RESUMO

Tocilizumab, an interleukin-6 receptor antagonist, has been used to treat critically ill patients with coronavirus disease-2019. We present the case of a previously immunocompetent man with coronavirus disease-2019 who developed invasive pulmonary aspergillosis after treatment with tocilizumab, illustrating the importance of considering opportunistic infections when providing immune modulating therapy.


Assuntos
Anticorpos Monoclonais Humanizados/efeitos adversos , Antivirais/efeitos adversos , Tratamento Farmacológico da COVID-19 , Aspergilose Pulmonar Invasiva/diagnóstico , Idoso , Anticorpos Monoclonais Humanizados/uso terapêutico , Antivirais/uso terapêutico , Aspergillus/isolamento & purificação , Humanos , Imunomodulação , Aspergilose Pulmonar Invasiva/tratamento farmacológico , Masculino , Micafungina/uso terapêutico , Infecções Oportunistas/induzido quimicamente , Receptores de Interleucina-6/antagonistas & inibidores , SARS-CoV-2/efeitos dos fármacos , Voriconazol/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa