Cytometry A ; 97(7): 674-680, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32488957

RESUMO

In response to the recent COVID-19 pandemic, many laboratories are involved in research supporting SARS-CoV-2 vaccine development and clinical trials. Flow cytometry laboratories will be responsible for a large part of this effort by sorting unfixed antigen-specific lymphocytes. Therefore, it is critical and timely that we have an understanding of risk assessment and established procedures of infectious cell sorting. Here we present procedures covering the biosafety aspects of sorting unfixed SARS-CoV-2-infected cells and other infectious agents of similar risk level. These procedures follow the ISAC Biosafety Committee guidelines and were recently approved by the National Institutes of Health Institutional Biosafety Committee for sorting SARS-CoV-2-infected cells. © 2020 International Society for Advancement of Cytometry.


Assuntos
Betacoronavirus/isolamento & purificação , Contenção de Riscos Biológicos/métodos , Infecções por Coronavirus/prevenção & controle , Citometria de Fluxo/métodos , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Manejo de Espécimes/métodos , COVID-19 , Infecções por Coronavirus/diagnóstico , Humanos , Laboratórios/normas , Pessoal de Laboratório Médico/normas , Pneumonia Viral/diagnóstico , Medição de Risco , SARS-CoV-2
2.
Cytometry A ; 95(2): 173-182, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30561906

RESUMO

Today's state-of-the-art cell sorting flow cytometers are equipped with aerosol containment systems designed to evacuate aerosols from the sort chamber during a sort. This biosafety device is especially important when the sort operator is sorting infectious or potentially infections samples. Hence, it is critical to evaluate the performance for this system in normal operation and in "failure" mode to determine the efficacy of containment. In the past decade, the most popular published method for evaluating containment has been the Glo-Germ bead procedure. These highly fluorescent and multisize particles can easily be detected on a microscope slide and enumerated using a fluorescent microscope. Collecting particles on this slide is accomplished using an Aerotech impactor. This sampler collects potentially escaping aerosols from the sort chamber before enumerating any particles. Although the Glo-Germ procedure has been adopted by many labs, there are several drawbacks with the procedure that have limited its adoption by cell sorter laboratories: The Aerotech impactor is a reusable device that requires rigorous cleaning between measurements. The surface area of the collection slide is large and difficult to scan on a fluorescence microscope. These beads produce a wide variation in sizes resulting in inconsistency in flow rates. Here, we describe a novel and replacement method utilizing a Cyclex-d impactor and Dragon Green beads. This method was compared for sensitivity of detection of escaped aerosols with a published method for aerosol detection which utilizes a UV-APS aerodynamic particle sizer and a UV-excitable dye. One of the advantages of the Cyclex-d system is the narrow-defined field of collection as compared to the standard Glo-Germ bead procedure, this means a smaller sampling area is used in the Cyclex-d impactor as compared to the AeroTech impactor. In addition, the sensitivity of detection was found to be better using the Cyclex-d collection device as compared to the standard Glo-Germ bead procedure. © 2018 International Society for Advancement of Cytometry.


Assuntos
Aerossóis/análise , Bioensaio/métodos , Citometria de Fluxo/métodos , Substâncias Perigosas/química , Separação Celular/métodos , Contenção de Riscos Biológicos/métodos , Contaminação de Equipamentos/prevenção & controle , Desenho de Equipamento/métodos , Laboratórios , Microscopia de Fluorescência/métodos , Microesferas , Tamanho da Partícula
3.
Cytometry A ; 93(11): 1087-1091, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30244531

RESUMO

We demonstrate improved methods for making valid and accurate comparisons of fluorescence measurement capabilities among instruments tested at different sites and times. We designed a suite of measurements and automated data processing methods to obtain consistent objective results and applied them to a selection of 23 instruments at nine sites to provide a range of instruments as well as multiple instances of similar instruments. As far as we know, this study represents the most accurate methods and results so far demonstrated for this purpose. The first component of the study reporting improved methods for photoelectron scale (Spe) evaluations, which was published previously (Parks, El Khettabi, Chase, Hoffman, Perfetto, Spidlen, Wood, Moore, and Brinkman: Cytometry A 91 (2017) 232-249). Those results which were within themselves are not sufficient for instrument comparisons, so here, we use the Spe scale results for the 23 cytometers and combine them with additional information from the analysis suite to obtain the metrics actually needed for instrument evaluations and comparisons. We adopted what we call the 2+2SD limit of resolution as a maximally informative metric, for evaluating and comparing dye measurement sensitivity among different instruments and measurement channels. Our results demonstrate substantial differences among different classes of instruments in both dye response and detection sensitivity and some surprisingly large differences among similar instruments, even among instruments with nominally identical configurations. On some instruments, we detected defective measurement channels needing service. The system can be applied in shared resource laboratories and other facilities as an aspect of quality assurance, and accurate instrument comparisons can be valuable for selecting instruments for particular purposes and for making informed instrument acquisition decisions. An institutionally supported program could serve the cytometry community by facilitating access to materials, and analysis and maintaining an archive of results. © 2018 International Society for Advancement of Cytometry.


Assuntos
Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Calibragem , Humanos
4.
Cytometry A ; 91(3): 232-249, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28160404

RESUMO

We developed a fully automated procedure for analyzing data from LED pulses and multilevel bead sets to evaluate backgrounds and photoelectron scales of cytometer fluorescence channels. The method improves on previous formulations by fitting a full quadratic model with appropriate weighting and by providing standard errors and peak residuals as well as the fitted parameters themselves. Here we describe the details of the methods and procedures involved and present a set of illustrations and test cases that demonstrate the consistency and reliability of the results. The automated analysis and fitting procedure is generally quite successful in providing good estimates of the Spe (statistical photoelectron) scales and backgrounds for all the fluorescence channels on instruments with good linearity. The precision of the results obtained from LED data is almost always better than that from multilevel bead data, but the bead procedure is easy to carry out and provides results good enough for most purposes. Including standard errors on the fitted parameters is important for understanding the uncertainty in the values of interest. The weighted residuals give information about how well the data fits the model, and particularly high residuals indicate bad data points. Known photoelectron scales and measurement channel backgrounds make it possible to estimate the precision of measurements at different signal levels and the effects of compensated spectral overlap on measurement quality. Combining this information with measurements of standard samples carrying dyes of biological interest, we can make accurate comparisons of dye sensitivity among different instruments. Our method is freely available through the R/Bioconductor package flowQB. © 2017 International Society for Advancement of Cytometry.


Assuntos
Citometria de Fluxo/métodos , Modelos Teóricos , Imagem Óptica/métodos , Calibragem , Citometria de Fluxo/estatística & dados numéricos , Análise dos Mínimos Quadrados
5.
Cytometry A ; 85(12): 1037-48, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25346474

RESUMO

Much of the complexity of multicolor flow cytometry experiments lies within the development of antibody staining panels and the standardization of instruments. In this article, we propose a theoretical metric and describe how measurements of sensitivity and resolution can be used to predict the success of panels, and ensure that performance across instruments is standardized (i.e., inter-instrument standardization). Sensitivity can be determined by summing two major contributors of background, background originating from the instrument (optical noise and electronic noise) and background due to the experimental conditions (i.e., Raman scatter, and spillover spreading arising from other fluorochromes in the panel). The former we define as Bcal and the latter we define as Bsos . The combination of instrument and experiment background is defined as Btot . Importantly, the Btot will affect the degree of panel separation, therefore the greater the degree of Btot the lower the separation potential. In contrast, resolution is a measure of separation between populations. Resolution is directly proportional to the number of photoelectrons generated per molecule of excited fluorochrome and is known as the "Q" value. Q and Btot values can be used to define the performance of each detector on an instrument and together they can be used to calculate a separation index. Hence, detectors with known Q and Btot values can be used to evaluate panel success based on the detector specific separation index. However, the current technologies do not enable measurements of Q and Btot values for all parameters, but new technology to allow these measurements will likely be introduced in the near future. Nonetheless, Q and Btot measurements can aid in panel development, and reveal sources of instrument-to-instrument variation in panel performance. In addition, Q and B values can form the basis for a comprehensive and versatile quality assurance program.


Assuntos
Citometria de Fluxo/instrumentação , Citometria de Fluxo/normas , Citometria de Fluxo/métodos , Humanos
6.
Cytometry A ; 85(5): 434-53, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24634405

RESUMO

Flow cytometric cell sorting of biological specimens has become prevalent in basic and clinical research laboratories. These specimens may contain known or unknown infectious agents, necessitating precautions to protect instrument operators and the environment from biohazards arising from the use of sorters. To this end the International Society of Analytical Cytology (ISAC) was proactive in establishing biosafety guidelines in 1997 (Schmid et al., Cytometry 1997;28:99-117) and subsequently published revised biosafety standards for cell sorting of unfixed samples in 2007 (Schmid et al., Cytometry Part A J Int Soc Anal Cytol 2007;71A:414-437). Since their publication, these documents have become recognized worldwide as the standard of practice and safety precautions for laboratories performing cell sorting experiments. However, the field of cytometry has progressed since 2007, and the document requires an update. The new Standards provides guidance: (1) for laboratory design for cell sorter laboratories; (2) for the creation of laboratory or instrument specific Standard Operating Procedures (SOP); and (3) on procedures for the safe operation of cell sorters, including personal protective equipment (PPE) and validation of aerosol containment.


Assuntos
Separação Celular/métodos , Citometria de Fluxo , Gestão da Segurança/normas , Sociedades Científicas , Separação Celular/normas , Contaminação de Equipamentos , Citometria de Fluxo/métodos , Citometria de Fluxo/normas , Substâncias Perigosas , Humanos , Laboratórios/normas , Saúde Ocupacional
7.
Nat Med ; 12(8): 972-7, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16862156

RESUMO

Immune responses arise from a wide variety of cells expressing unique combinations of multiple cell-surface proteins. Detailed characterization is hampered, however, by limitations in available probes and instrumentation. Here, we use the unique spectral properties of semiconductor nanocrystals (quantum dots) to extend the capabilities of polychromatic flow cytometry to resolve 17 fluorescence emissions. We show the need for this power by analyzing, in detail, the phenotype of multiple antigen-specific T-cell populations, revealing variations within complex phenotypic patterns that would otherwise remain obscure. For example, T cells specific for distinct epitopes from one pathogen, and even those specific for the same epitope, can have markedly different phenotypes. The technology we describe, encompassing the detection of eight quantum dots in conjunction with conventional fluorophores, should expand the horizons of flow cytometry, as well as our ability to characterize the intricacies of both adaptive and innate cellular immune responses.


Assuntos
Citometria de Fluxo/métodos , Imunofenotipagem/métodos , Nanotecnologia , Pontos Quânticos , Complexo CD3/imunologia , Antígenos CD8/imunologia , Epitopos , Fluoresceína-5-Isotiocianato , Corantes Fluorescentes , Antígenos HLA-DR/imunologia , Humanos , Complexo Principal de Histocompatibilidade , Semicondutores , Linfócitos T/imunologia
8.
J Immunol ; 185(11): 6646-63, 2010 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-20980630

RESUMO

Because T cells act primarily through short-distance interactions, homing receptors can identify colocalizing cells that serve common functions. Expression patterns for multiple chemokine receptors on CD4(+) T cells from human blood suggested a hierarchy of receptors that are induced and accumulate during effector/memory cell differentiation. We characterized CD4(+)CD45RO(+) T cells based on expression of two of these receptors, CCR5 and CCR2, the principal subsets being CCR5(-)CCR2(-) (∼70%), CCR5(+)CCR2(-) (∼25%), and CCR5(+)CCR2(+) (∼5%). Relationships among expression of CCR5 and CCR2 and CD62L, and the subsets' proliferation histories, suggested a pathway of progressive effector/memory differentiation from the CCR5(-)CCR2(-) to CCR5(+)CCR2(-) to CCR5(+)CCR2(+) cells. Sensitivity and rapidity of TCR-mediated activation, TCR signaling, and effector cytokine production by the subsets were consistent with such a pathway. The subsets also showed increasing responsiveness to IL-7, and the CCR5(+)CCR2(+) cells were CD127(bright) and invariably showed the greatest response to tetanus toxoid. CCR5(+)CCR2(+) cells also expressed the largest repertoire of chemokine receptors and migrated to the greatest number of chemokines. By contrast, the CCR5(+)CCR2(-) cells had the greatest percentages of regulatory T cells, activated/cycling cells, and CMV-reactive cells, and were most susceptible to apoptosis. Our results indicate that increasing memory cell differentiation can be uncoupled from susceptibility to death, and is associated with an increase in chemokine responsiveness, suggesting that vaccination (or infection) can produce a stable population of effector-capable memory cells that are highly enriched in the CCR5(+)CCR2(+) subset and ideally equipped for rapid recall responses in tissue.


Assuntos
Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD4-Positivos/metabolismo , Memória Imunológica , Receptores CCR2/fisiologia , Subpopulações de Linfócitos T/imunologia , Subpopulações de Linfócitos T/metabolismo , Linfócitos T CD4-Positivos/citologia , Diferenciação Celular/imunologia , Células Cultivadas , Humanos , Imunofenotipagem , Receptores CCR2/biossíntese , Receptores CCR5/biossíntese , Receptores CCR5/imunologia , Receptores CCR5/metabolismo , Fase de Repouso do Ciclo Celular/imunologia , Subpopulações de Linfócitos T/citologia
9.
Cytometry A ; 79(1): 84-9, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21182185

RESUMO

Quantum dots (QD) are fluorescent nanocrystals that are highly useful in imaging and flow cytometric analyses. During routine use of monoclonal antibody conjugates of QD, we have occasionally seen partial or total loss of fluorescence when using certain lots of fixative solutions. We hypothesized that a low level contamination with heavy metal cations was responsible, since low level metal contaminants are not uncommon in formalin solutions. By titrating known concentrations of heavy metal cations into staining solutions, we found that millimolar concentrations of ferrous and zinc ions, and as low as 50 nanomolar cupric ions, completely eliminated QD fluorescence. By mass spectroscopic quantification of metals in commercial fixative solutions previously shown to perform poorly or well with regard to QD fluorescence, we confirmed that the presence of copper in solution was correlated with poor performance. Notably, prior addition of EDTA to chelate the divalent cations in these solutions prevented the inhibition of QD fluorescence. Finally, the copper-induced loss of QD fluorescence is irreversible: cells labeled with QD are highly fluorescent and can be rendered nonfluorescent by the addition of cupric sulfate, even after washing extensively. Indeed, these cells can then be successfully stained with other QD reagents, providing a method for immunofluorescence restaining of cells without contaminating fluorescence from the first stain.


Assuntos
Cobre/análise , Ferro/análise , Pontos Quânticos , Zinco/análise , Fixadores/química , Citometria de Fluxo/métodos , Fluorescência , Formaldeído , Humanos , Indicadores e Reagentes , Íons , Leucócitos Mononucleares/química