Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Arthroplasty ; 35(8): 2249-2253, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32279944

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) with posterior-stabilized (PS) or posterior cruciate-retaining (CR) implants has high success rates and survivorship. However, it is uncertain how laxity and constraint are associated with long-term polyethylene wear under physiological conditions. METHODS: To answer this question, we measured the laxity patterns of 47 harvested cadaver specimens with primary TKAs in a custom knee-testing machine at full extension and at 30°, 60°, and 90° of flexion. The wear patterns of the tibial inserts were assessed using a semiquantitative method which is a modified approach of that proposed by Hood et al in 1983. RESULTS: Statistical analysis found that the PS TKA cohort had a statistically significant increase in varus laxity at 60° and 90° of flexion, as well as total coronal laxity at 60° of flexion when compared to the CR cohort. Furthermore, analysis demonstrated a significant correlation between increased PS coronal laxity and increased tibial wear, a trend that was not seen in the CR specimens. CONCLUSION: Our findings suggest that greater laxity in flexion after primary TKA may increase the wear realized over time and that PS TKAs may be more susceptible due to the loss of support the PCL affords to the flexion space. Whether a CR or PS TKA is used, surgeons need to avoid the pitfalls that may create greater flexion laxity during the procedure to optimize long-term polyethylene wear.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Ligamento Cruzado Posterior , Fenômenos Biomecânicos , Estudos de Coortes , Humanos , Articulação do Joelho/cirurgia , Ligamento Cruzado Posterior/cirurgia , Amplitude de Movimento Articular , Tíbia/cirurgia
2.
J Arthroplasty ; 35(2): 569-578, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31699531

RESUMO

BACKGROUND: The purpose of this study is to determine the preferred sampling location for tissue analysis in total knee arthroplasty (TKA) and to evaluate metal concentrations, inflammatory cytokines, component damage, and tissue metallosis. METHODS: Twenty TKA systems were collected at necropsy along with tissue samples from 5 distinct locations. Inductively coupled plasma mass spectrometry (ICP-MS) analysis was performed to determine cobalt (Co), chromium (Cr), and titanium (Ti) concentrations. Synovial fluid cytokine analysis was preformed using a Magnetic Luminex Screening Assay. Femoral components were assesed for damage and tissues were visually scored for metallosis. RESULTS: The median metal concentrations were 16 ppb for Co, 46 ppb for Cr, and 9.8 ppb for Ti. There was no association between the tissue collection site and the metal concentration for Co (P = .979), Cr (P = .712), or Ti (P = .854). Twelve of 20 of the necropsy-retrieved TKAs had metallosis, but there was no correlation between Co (P = .48), Cr (P = .89), or Ti (P = .60) concentration and metallosis. Increased Co was associated with decreased tumor necrosis factor alpha (ρ = -0.56, P = .01) and interleukin 1 beta (ρ = -0.48, P = .03). Increased Cr was associated with decreased tumor necrosis factor alpha (ρ= -0.47, P = .03), interleukin 6 (ρ= -0.43, P = .04), and macrophage inflammatory protein 3 alpha (ρ= -0.47, P = .03). CONCLUSION: We observed elevated Co, Cr, and Ti concentrations in tissue from necropsy-retrieved TKA. Our findings did not support the hypothesis that tissue metal concentrations were associated with inflammatory cytokines. The results of this research will be useful for the design of future prospective studies.


Assuntos
Artroplastia do Joelho , Artroplastia do Joelho/efeitos adversos , Cromo , Cobalto , Humanos , Metais , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa