Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Dairy Sci ; 101(11): 10116-10125, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30146281

RESUMO

The emergence of antimicrobial resistance to commonly used antibiotics has necessitated the development of new antimicrobial products. Crude extracts produced by actinomycetes contain antimicrobial metabolites that can inhibit bacterial growth. The objective of our study was to evaluate the antimicrobial activity of crude extracts (Caat1-54 and CaatP5-8) produced by actinomycetes against isolates of Staphylococcus aureus, Staphylococcus chromogenes, Streptococcus dysgalactiae, and Streptococcus uberis, which were obtained from the milk of cows affected by mastitis in 23 dairy herds. Twenty isolates of each bacterial species were used to define minimum inhibitory concentrations (MIC) of both crude extracts and ceftiofur (positive control). The MIC50 and MIC90 were defined at the concentration required to inhibit the growth of 50 and 90% of bacterial isolates tested, respectively. The MIC results were evaluated by survival analysis. Staphylococcus aureus isolates presented MIC90 of Caat 1-54 ≥6.25 µg/mL, ceftiofur ≥12.5 µg/mL, and Caat P5-8 ≥100 µg/mL. Streptococcus uberis presented MIC90 of ceftiofur ≥0.39 µg/mL, Caat 1-54 ≥50 µg/mL, and Caat P5-8 ≥100 µg/mL. Staphylococcus chromogenes isolated from subclinical mastitis presented MIC90 of Caat 1-54 ≥0.78 µg/mL and ceftiofur and Caat P5-8 of ≥6.25 and ≥100 µg/mL, respectively. Streptococcus dysgalactiae isolated from clinical mastitis presented similar MIC90 values between antimicrobials tested (ceftiofur, Caat 1-54, and Caat P-58), but these values (≥100 µg/mL) were higher than the values obtained from other pathogens evaluated in the present study. Our results indicate that Caat 1-54 and Caat P5-8 crude extracts present in vitro antimicrobial activity against isolates of Staph. aureus, Staph. chromogenes, Strep. dysgalactiae, and Strep. uberis isolated from clinical and subclinical mastitis.


Assuntos
Actinobacteria/química , Anti-Infecciosos/farmacologia , Misturas Complexas/farmacologia , Mastite Bovina/tratamento farmacológico , Infecções Estafilocócicas/veterinária , Infecções Estreptocócicas/veterinária , Animais , Anti-Infecciosos/química , Anti-Infecciosos/isolamento & purificação , Bovinos , Cefalosporinas/química , Cefalosporinas/isolamento & purificação , Cefalosporinas/farmacologia , Misturas Complexas/química , Misturas Complexas/isolamento & purificação , Feminino , Mastite Bovina/microbiologia , Testes de Sensibilidade Microbiana/veterinária , Leite/microbiologia , Infecções Estafilocócicas/tratamento farmacológico , Infecções Estafilocócicas/microbiologia , Staphylococcus/efeitos dos fármacos , Infecções Estreptocócicas/tratamento farmacológico , Infecções Estreptocócicas/microbiologia , Streptococcus/efeitos dos fármacos
2.
Pharmazie ; 65(1): 9-14, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20187572

RESUMO

UV-VIS-Spectrophotometric and spectrofluorimetric methods have been developed and validated allowing the quantification of chloroaluminum phthalocyanine (CIAIPc) in nanocarriers. In order to validate the methods, the linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, and selectivity were examined according to USP 30 and ICH guidelines. Linearities range were found between 0.50-3.00 microg x mL(-1) (Y = 0.3829 X [CIAIPc, microg x mL(-1)] + 0.0126; r = 0.9992) for spectrophotometry, and 0.05-1.00 microg x mL(-1) (Y = 2.24 x 10(6) X [CIAIPc, microg x mL(-1)] + 9.74 x 10(4); r = 0.9978) for spectrofluorimetry. In addition, ANOVA and Lack-of-fit tests demonstrated that the regression equations were statistically significant (p<0.05), and the resulting linear model is fully adequate for both analytical methods. The LOD values were 0.09 and 0.01 microg x mL(-1), while the LOQ were 0.27 and 0.04 microg x mL(-1) for spectrophotometric and spectrofluorimetric methods, respectively. Repeatability and intermediate precision for proposed methods showed relative standard deviation (RSD) between 0.58% to 4.80%. The percent recovery ranged from 98.9% to 102.7% for spectrophotometric analyses and from 94.2% to 101.2% for spectrofluorimetry. No interferences from common excipients were detected and both methods were considered specific. Therefore, the methods are accurate, precise, specific, and reproducible and hence can be applied for quantification of CIAIPc in nanoemulsions (NE) and nanocapsules (NC).


Assuntos
Portadores de Fármacos/análise , Indóis/análise , Nanopartículas/análise , Compostos Organometálicos/análise , Radiossensibilizantes/análise , Algoritmos , Análise de Variância , Cromatografia Líquida de Alta Pressão , Indicadores e Reagentes , Padrões de Referência , Reprodutibilidade dos Testes , Solubilidade , Espectrometria de Fluorescência , Espectrofotometria Ultravioleta
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa