Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 142
Filtrar
1.
Kidney Int ; 104(1): 189-200, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36990214

RESUMO

Use of a covered stent after percutaneous transluminal angioplasty (PTA) was compared to PTA alone for treatment of upper extremity hemodialysis patients with arteriovenous fistula (AVF) stenoses. Patients with AVF stenosis of 50% or more and evidence of AVF dysfunction underwent treatment with PTA followed by randomization of 142 patients to include a covered stent or 138 patients with PTA alone. Primary outcomes were 30-day safety, powered for noninferiority, and six-month target lesion primary patency (TLPP), powered to test whether TLPP after covered-stent placement was superior to PTA alone. Twelve-month TLPP and six-month access circuit primary patency (ACPP) were also hypothesis tested while additional clinical outcomes were observed through two years. Safety was significantly non-inferior while six- and 12-month TLPP were each superior for the covered stent group compared to PTA alone (six months: 78.7% versus 55.8%; 12 months: 47.9% versus 21.2%, respectively). ACPP was not statistically different between groups at six-months. Observed differences at 24 months favored the covered-stent group: 28.4% better TLPP, fewer target-lesion reinterventions (1.6 ± 1.6 versus 2.8 ± 2.0), and a longer mean time between target-lesion reinterventions (380.4 ± 249.5 versus 217.6 ± 158.4 days). Thus, our multicenter, prospective, randomized study of a covered stent used to treat AVF stenosis demonstrated noninferior safety with better TLPP and fewer target-lesion reinterventions than PTA alone through 24 months.


Assuntos
Angioplastia com Balão , Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Humanos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/terapia , Grau de Desobstrução Vascular , Constrição Patológica/etiologia , Angioplastia com Balão/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Angioplastia/efeitos adversos , Stents , Fístula Arteriovenosa/etiologia , Diálise Renal/efeitos adversos
2.
Eur Spine J ; 32(1): 8-19, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35835893

RESUMO

PURPOSE: Abdominal aortic aneurysms (AAAs) affect the vascular perfusion of the lumbar spine. The treatment of AAAs with endovascular aortic aneurysm repair (EVAR) completely occludes the direct vascular supply to the lumbar spine. We hypothesized that patients with AAA who undergo EVAR show a different pattern of spinal degeneration than individuals without AAA. METHODS: In this retrospective institutional review board-approved study, 100 randomly selected patients with AAA who underwent EVAR with computed tomography (CT) scans between 2005 and 2017 were compared with age- and gender-matched controls without AAA. In addition, long-term follow-up CT images (> 6 months before EVAR, at the time of EVAR, and > 12 months after EVAR) of the patients were analysed to compare the progression of degeneration from before to after EVAR. Degeneration scores, lumbar levels with the most severe degeneration, and lumbar levels with progressive degeneration were analysed in all CT images. Fisher's exact test, Wilcoxon signed-rank test, and Mann-Whitney U test were performed for statistical analyses. RESULTS: Compared with the control group (n = 94), the most severe degeneration was more commonly detected in the mid-lumbar area in the patient group (n = 100, p = 0.016), with significantly more endplate erosions being detected in the lumbar spine (p = 0.015). However, EVAR did not result in significant additional acceleration of the degenerative process in the long-term follow-up analysis (n = 51). CONCLUSION: AAA is associated with atypical, more cranially located spinal degradation, particularly in the mid-lumbar segments; however, EVAR does not seem to additionally accelerate the degenerative process. This observation underlines the importance of disc and endplate vascularization in the pathomechanism of spinal degeneration. LEVEL OF EVIDENCE I: Diagnostic: individual cross-sectional studies with consistently applied reference standard and blinding.


Assuntos
Aneurisma da Aorta Abdominal , Procedimentos Endovasculares , Humanos , Estudos Retrospectivos , Estudos Transversais , Procedimentos Cirúrgicos Vasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/epidemiologia , Aneurisma da Aorta Abdominal/cirurgia , Resultado do Tratamento , Procedimentos Endovasculares/métodos , Fatores de Risco
3.
Transfus Med Hemother ; 50(3): 226-233, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37434998

RESUMO

Introduction: Postpartum hemorrhage (PPH) is the leading cause of peripartal maternal mortality and accounts for 25% of all maternal deaths worldwide. The most common reasons of PPH are uterine atony, retained placenta, or placenta accreta spectrum. Treatment of PPH depends on the etiology and corresponds to a stepwise approach, which follows the German, Austrian and Swiss guideline for the diagnosis and therapy of PPH in Switzerland. In severe ongoing PPH, hysterectomy has been the ultima ratio for many decades. Nowadays, interventional embolization of the pelvic arteries (PAE) has become a popular alternative. Besides being a highly effective minimally invasive method, PAE avoids hysterectomy with consecutively reduced morbidity and mortality. However, data on the long-term effects of PAE on fertility and menstrual cycle are scarce. Methods: We performed a monocentric study consisting of a retro- and a prospective part including all women who had undergone a PAE between 2012 and 2016 at University Hospital Zurich. Descriptive characteristics of patients and efficacy of PAE defined as cessation of bleeding were analyzed retrospectively. In the prospective part, all patients were contacted for a follow-up questionnaire regarding menstruation and fertility after embolization. Results: Twenty patients with PAE were evaluated. Our data showed a success rate of PAE in 95% of patients with PPH; only 1 patient needed a second, then successful, PAE. No patient needed a hysterectomy or any other surgical intervention. In our study, an association between mode of delivery and identified etiology of PPH is observed. After spontaneous delivery (n = 6), the main reason of severe PPH was retained placenta (n = 4), while after cesarean section (n = 14), uterine atony was identified in most cases (n = 8). Regarding menstruation after embolization, all women reported regular menstruation after the breastfeeding period (100%). The majority reported a regular pattern with a shorter or similar duration (73%) and lower or similar intensity (64%). Dysmenorrhea decreased in 67% of patients. Four patients planned another pregnancy, of whom only one had become pregnant with assisted reproductive technology and ended up in a miscarriage. Discussion: Our study confirms the efficacy of PAE in PPH, thus obviating complex surgical interventions and associated morbidity. The success of PAE does not depend on the primary cause of PPH. Our results may encourage the prompt decision to perform PAE in the management of severe PPH in case of failure of conservative management and help physicians in the post-interventional counseling regarding menstruation patterns and fertility.

4.
J Vasc Interv Radiol ; 32(9): 1377-1385, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34462082

RESUMO

The purpose of this study was to evaluate the feasibility of recanalization of chronic noncirrhotic, nonmalignant splanchnic thromboses with a transsplenic assisted patient-tailored approach with or without transjugular intrahepatic portosystemic shunt (TIPS) creation. In this retrospective study, 10 patients (median age, 48.4 years; interquartile range, 5.1 years) underwent revascularization between November 2016 and August 2020. Portal cavernoma was present in all patients, with complete splenic vein thrombosis in 70%. The technical success rate was 80%. Additional TIPS creation was performed in 5 (50%) patients. At a median follow-up of 19.3 months (interquartile range, 17.9 months), the primary and secondary patency rate was 70% and 100%, respectively. During follow-up, 1 patient died due to recurrent upper gastrointestinal variceal hemorrhage. In conclusion, percutaneous transsplenic assisted recanalization of chronic noncirrhotic, nonmalignant splanchnic thromboses is feasible. However, multiple access points may still be needed. Additional TIPS creation appears to be necessary only in case of insufficient portal venous flow into the liver.


Assuntos
Varizes Esofágicas e Gástricas , Derivação Portossistêmica Transjugular Intra-Hepática , Trombose , Adulto , Hemorragia Gastrointestinal , Humanos , Pessoa de Meia-Idade , Veia Porta/diagnóstico por imagem , Veia Porta/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
5.
J Vasc Interv Radiol ; 31(5): 754-758, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32359522

RESUMO

This brief report describes 3 patients with infected extrahepatic splanchnic venous stents or stent grafts. These devices had been placed to treat prehepatic portal hypertension 4 wk, 3 mo, and 31 mo, respectively, before readmission for fever. Blood cultures and fluorine-18 fludeoxyglucose positron emission tomography/CT were positive in all. With systemic antibiotic treatment, 2 patients showed a clinical recovery. In the third patient, antibiotic treatment failed. Therefore, the infected stent graft was surgically removed and a splenorenal shunt was created. No recurrent splanchnic venous infection was observed in these 3 patients.


Assuntos
Antibacterianos/administração & dosagem , Implante de Prótese Vascular/instrumentação , Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/instrumentação , Hipertensão Portal/cirurgia , Infecções Relacionadas à Prótese/terapia , Stents/efeitos adversos , Resultado do Tratamento , Adolescente , Idoso , Implante de Prótese Vascular/efeitos adversos , Remoção de Dispositivo , Procedimentos Endovasculares/efeitos adversos , Humanos , Hipertensão Portal/diagnóstico , Hipertensão Portal/fisiopatologia , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente , Pressão na Veia Porta , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/microbiologia , Estudos Retrospectivos , Circulação Esplâncnica
6.
J Vasc Interv Radiol ; 31(4): 551-557, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31882302

RESUMO

PURPOSE: To analyze and correlate preinterventional magnetic resonance (MR) imaging findings with clinical symptoms after percutaneous sclerotherapy of venous malformations (VMs) adjacent to the knee. MATERIALS AND METHODS: Twenty-five patients (mean age, 24 y; range, 7-55 y; 11 female) with 26 VMs adjacent to the knee undergoing sclerotherapy (direct puncture, diagnostic angiography, sclerosant injection) were identified, and MR imaging findings were analyzed. The VM involved the synovium of the knee joint in 19 of 26 cases (76%). These lesions were associated with joint effusion (3 of 19; 16%), hemarthrosis (4 of 19; 21%), or synovial thickening (16 of 19; 84%). Follow-up ended 6-8 weeks after the first or second sclerotherapy session if complete pain relief was achieved or 3 months after the third sclerotherapy session. Treatment outcomes were categorized as symptom improvement (complete or partial pain relief) or poor response (unchanged or increased pain). RESULTS: Forty-nine percutaneous sclerotherapy sessions were performed. Despite the absence of signs of knee osteoarthritis, patients with a VM involving the synovium (8 of 14; 57%) showed a poor response to sclerotherapy (1 of 8 [13%] pain-free after 1 sclerotherapy session). Among patients with VMs with no associated joint alteration and no synovial involvement (6 of 14; 43%), 5 of 6 (83%) showed improvement of symptoms after 1 sclerotherapy session (P < .05). CONCLUSIONS: Juxta-articular VMs of the knee are frequently associated with hemarthrosis and synovial thickening. Patients with signs of osteoarthritis and synovial involvement of the VM on presclerotherapy MR imaging deserve special consideration, as these findings predict worse clinical symptoms after sclerotherapy.


Assuntos
Joelho/irrigação sanguínea , Imageamento por Ressonância Magnética , Soluções Esclerosantes/administração & dosagem , Escleroterapia , Membrana Sinovial/irrigação sanguínea , Malformações Vasculares/terapia , Veias/diagnóstico por imagem , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Soluções Esclerosantes/efeitos adversos , Escleroterapia/efeitos adversos , Resultado do Tratamento , Malformações Vasculares/diagnóstico por imagem , Veias/anormalidades , Adulto Jovem
7.
Ann Plast Surg ; 85(4): 407-412, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32000251

RESUMO

OBJECTIVE: This study aimed to determine the benefits of sclerotherapy with OK-432 for the treatment of postoperative chronic lymphocele. BACKGROUND: Postoperative chronic lymphocele formation is common and accounts for a high postoperative morbidity. Nonsurgical strategies comprise repetitive percutaneous fluid aspiration or percutaneous sclerotherapy. OK-432 has been used to treat congenital lymphatic malformations with several reports of promising results. We hypothesized that it is more beneficial than repetitive percutaneous fluid aspiration for the treatment of symptomatic lymphocele. METHODS: Two cohorts of melanoma patients who developed recurrent lymphocele after lymph node dissection from January 2013 to August 2017 were compared. The first cohort was treated with repetitive percutaneous fluid aspiration (n = 20). The second cohort received OK-432 sclerotherapy (n = 20). Primary end points were overall treatment duration, number of treatment sessions, and the clinical success in both cohorts. Secondary end points were surgical site infection rate, need for additional antibiotic treatment, wound healing disorders, and the need for revision surgery. RESULTS: Mean overall duration of treatment with sclerotherapy was significantly shorter than with repetitive aspiration (9.4 ± 7.2 vs 47.5 ± 31.9 days, P < 0.01). Mean number of sclerotherapy treatment sessions were 2.5 ± 1.2. Clinical success with OK-432 was 19 of 20, and that with repeated aspiration was 7 of 20 (χ = 15.82, P < 0.001). No surgical site infection occurred in the sclerotherapy cohort, which was significantly lower than those treated with repetitive aspiration (P < 0.03). Surgical revision was mandatory in 12 of 20 patients who were treated with repetitive aspiration, and only 1 of 20 patients in the sclerotherapy cohort. CONCLUSION: Sclerotherapy with OK-432 for the treatment of postoperative lymphocele is highly beneficial with a significant reduction of morbidity and the overall treatment time compared with repetitive aspiration.


Assuntos
Linfocele , Picibanil , Escleroterapia , Estudos de Coortes , Humanos , Excisão de Linfonodo , Linfocele/etiologia , Linfocele/terapia , Picibanil/uso terapêutico , Estudos Retrospectivos
8.
Vasa ; 49(1): 39-42, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31549917

RESUMO

Background: To present a technique of sheath supported contralateral limb gate (CLG) cannulation of modular bifurcated stent-graft in endovascular abdominal aortic repair. Materials and methods: After totally percutaneous bilateral femoral access, the 9F introducer sheath is exchanged to a 30 cm 12 fr introducer sheath over a stiff wire contralateral to the intended main stent-graft insertion side and advanced into the aorta below the lowest renal artery. Parallel to the stiff wire within the sheath an additional standard J-tip guidewire with a 5 fr Pigtail angiographic catheter is advanced to the level of the renal arteries. After main body deployment, the 12 fr introducer sheath and J-tip wire with pigtail catheter are retracted until the CLG opening level, maintaining the stiff "buddy" wire in position to support the 12 fr sheath, maintaining its distal opening close to the contralateral gate opening to achieve easy cannulation. Results: Retrospective analysis of video archive from July 2016 to February 2018 evidenced 55 recorded EVAR cases. All CLG cannulations were obtained with Standard J-tip or Terumo Glidewire wires and with Pig-Tail or Berenstein catheters. Technical success was 100 %. Mean fluoroscopy time to accomplish CLG cannulation was 37.6 33 (range 1-105) seconds. The aortic carrefour angulation on coronal axis strongly correlates with cannulation time p = <.001, with longer cannulation time for higher carrefour angulations on coronal axis (Pearson correlation coefficient 0.47). Conclusions: The use of 12 fr sheath with parallel wire introduction technique, appears to be a safe and reliable tool to facilitate CLG cannulation during EVAR procedures.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Prótese Vascular , Humanos , Estudos Retrospectivos , Stents , Resultado do Tratamento
9.
Radiol Med ; 125(10): 971-980, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32270335

RESUMO

PURPOSE: Quantification of post-interventional adverse events of outpatient SIRT leading to hospitalization and quantification of radiation exposure. MATERIALS AND METHODS: In this single-center, retrospective cohort study, we reviewed 212 patients treated with SIRT (90Y-microspheres) for primary and secondary liver malignancies. We searched for adverse events (AEs) and serious adverse events (SAEs), defined as AE's causing hospitalization. Additionally, radiation exposure was measured in 36 patients. RESULTS: Seven patients had an SAE (3.3%), four patients had AE without readmission/hospitalization (1.9%) and 201 patients had no complications (94.8%). The mean ambient dose rate at 1 m distance from the source after administration of 90Y-microspheres was 1.88 µSv/h ± 0.74 (± SD) with a range from 4.3 to 0.2 µSv/h. CONCLUSION: Outpatient radioembolization with 90Y-microspheres is safe and requires hospitalization only in a very small number of patients. The mean dose rate was low and met the national conditions for outpatient treatment (< 5 µSv/h).


Assuntos
Assistência Ambulatorial , Embolização Terapêutica/métodos , Hospitalização , Neoplasias Hepáticas/terapia , Microesferas , Radioisótopos de Ítrio/administração & dosagem , Angiografia , Embolização Terapêutica/efeitos adversos , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/secundário , Masculino , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Exposição à Radiação/análise , Pneumonite por Radiação/prevenção & controle , Estudos Retrospectivos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Radioisótopos de Ítrio/efeitos adversos
10.
Ther Umsch ; 77(2): 53-56, 2020.
Artigo em Alemão | MEDLINE | ID: mdl-32633228

RESUMO

Diagnosis and Minimal Invasive Treatment of Benign Prostatic Hyperplasia Abstract. Benign prostatic hyperplasia (BPH) is a common condition in men aged 50 - 60 years with a prevalence of about 50 %. After failure of conservative treatment, the standard treatment of BPH is transurethral resection of the prostate (TURP). However, over the last years prostatic artery embolization (PAE) emerged as a minimal invasive alternative to treat lower urinary tract symptoms. After patient assessment by MRI and CT of the prostate to rule out possible contraindications of PAE, the procedure can be performed in an outpatient setting under local anesthesia by an interventional radiologist. Especially for frail patients and / or patients with special risks regarding surgery / anesthesia, PAE may be an alternative to TURP with fewer complications.


Assuntos
Embolização Terapêutica , Sintomas do Trato Urinário Inferior/diagnóstico , Sintomas do Trato Urinário Inferior/etiologia , Sintomas do Trato Urinário Inferior/terapia , Hiperplasia Prostática/diagnóstico , Hiperplasia Prostática/cirurgia , Hiperplasia Prostática/terapia , Ressecção Transuretral da Próstata , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
11.
Ther Umsch ; 77(2): 57-61, 2020.
Artigo em Alemão | MEDLINE | ID: mdl-32633227

RESUMO

Endometriosis Abstract. Endometriosis, which is the presence of functional endometrial tissue outside the endometrium, represents one of the most common gynecological diseases. Given the variability of the symptoms depending on the exact localization of the disease, it is not uncommon for a patient to be diagnosed only after approximately 10 years of suffering. Localizations of the disease can include the typical endometrioma of the ovaries and in particular the lesser pelvis (e. g., fallopian tubes, uterine ligaments). It is then termed "deep pelvic endometriosis" and may be the reason for scarring, chronic pelvic pain and infertility. MRI has become increasingly popular in assessing the extent of the disease, due to its increasing availability and excellent soft tissue contrast. Recently, European guidelines have been published to better standardize technical MRI parameters and reporting, in addition to several scoring systems (e. g., the ENZIAN score), which have been established in the past. This allows for a precise localization of the disease and may guide surgical management in advanced cases. Other therapeutic options - depending on the severity of the symptoms - include pain medication or hormonal treatments. In the case of adenomyosis, the embolization of the uterine arteries as a minimally invasive approach has demonstrated excellent results.


Assuntos
Endometriose/diagnóstico , Endometriose/terapia , Feminino , Humanos , Imageamento por Ressonância Magnética , Dor Pélvica/terapia , Pelve
12.
Radiology ; 291(2): 531-538, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30835189

RESUMO

Background Optimal timing of the CT scan relative to the contrast media bolus remains a challenging task given the shorter scan durations of modern CT scanners, as well as interpatient variability. Purpose To compare contrast opacification in CT angiography of the aorta between a cohort with fixed trigger delay and a cohort with patient-specific individualized trigger delay for contrast media timing with bolus tracking. Materials and Methods In this prospective study (January-August 2018), CT angiography of the thoracoabdominal aorta with bolus tracking was performed in two different study cohorts: one with a fixed trigger delay of 4 seconds (fixed cohort) and one with a patient-specific trigger delay (individualized cohort). All CT and contrast media protocol parameters were kept identical among cohorts. Objective image quality was evaluated by one reader; two readers assessed subjective image quality. Student t test was used to test for differences in mean attenuation; the Wilcoxon-Mann-Whitney test was used to test for differences in noise, contrast-to-noise ratio, and subjective image quality. Results The fixed cohort had 108 study participants (16 women; mean age ± standard deviation, 72 years ± 10); the individualized cohort had 108 participants (16 women; mean age, 72 years ± 12). The trigger delay in the individualized cohort ranged from 6.4-11.3 seconds (mean, 9.2 seconds). There was higher overall attenuation in the individualized cohort than in the fixed cohort (486 HU ± 92 for individualized vs 438 HU ± 99 for fixed; P < .001), with increasing differences from the aortic arch (8 HU) to the iliac arteries (95 HU). The regression model indicated uniform attenuation in the individualized cohort and decreasing attenuation in the fixed cohort (decrease of 87 HU by the iliac arteries; P < .001). There was no difference between cohorts for image noise (20 vs 19; P = .41), but contrast-to-noise ratio (21 vs 19; P = .04) and subjective image quality were higher in the individualized cohort than in the fixed cohort (excellent or good image quality, 100% vs 67%; P < .001). Conclusion Compared with a fixed delay time after bolus tracking, a patient-specific individualized trigger delay improves image quality and provides uniform contrast attenuation for CT angiography of the aorta. ©RSNA, 2019.


Assuntos
Aorta/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Aortografia/métodos , Feminino , Humanos , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo
13.
J Endovasc Ther ; 26(6): 871-878, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31478457

RESUMO

Purpose: To evaluate the feasibility of a patient-specific rehearsal (PsR) before emergency endovascular aneurysm repairs (eEVAR) and its influence on the operation. Materials and Methods: From February 2016 to October 2016, 10 consecutive patients (mean age 75±7.4 years; 9 men) presenting with a ruptured abdominal aortic aneurysm (rAAA) suitable for standard EVAR were enrolled in the study. A 3-dimensional (3D) model of the abdominal aorta was generated on a virtual reality simulator based on the patient's computed tomography (CT) images. Following the patient-specific simulation setup, PsR was conducted during patient admission or in parallel with the preoperative eEVAR workup. Measured outcomes were PsR feasibility only in the first 4 patients and impact on operative performance thereafter (changes in device selection, the planning process, clinical outcomes, perioperative mortality, and complication rates). Technical metrics and timing of system setup, rehearsal, interval from patient arrival to the actual procedure, and eEVAR were recorded. Results: Mean time for 3D model creation was 21.3±7.8 minutes (range 13-37); there was a significant positive relationship between aortic neck diameter and segmentation time (p=0.003). The overall mean time for simulator setup and PsR was 54±14 minutes (range 37-80); PsR alone was completed in a mean 31±40 minutes (95% confidence interval -60 to -2.2). The actual eEVAR procedure duration was 69±16 minutes (range 45-90). No delay in the actual eEVAR procedure was registered owing to the PsR pathway. In 6 patients, preprocedure rehearsal induced changes in operative strategy, including device selection, main body introduction side, and/or deployment configuration. In 4 cases, rehearsal was performed twice to achieve optimal performance. Conclusion: PsR before eEVAR was feasible in all cases and caused no time delays in the actual eEVAR procedure. PsR optimized eEVAR planning by identifying optimal strategy for stent-graft component selection and deployment.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Modelagem Computacional Específica para o Paciente , Cirurgia Assistida por Computador , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/mortalidade , Ruptura Aórtica/fisiopatologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Estudos de Viabilidade , Feminino , Humanos , Masculino , Modelos Anatômicos , Modelos Cardiovasculares , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , Impressão Tridimensional , Desenho de Prótese , Fatores de Risco , Stents , Cirurgia Assistida por Computador/efeitos adversos , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/mortalidade , Fatores de Tempo , Resultado do Tratamento
14.
J Vasc Surg ; 68(1): 83-90.e2, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29602473

RESUMO

OBJECTIVE: The objective of this study was to report the 1-year follow-up study results of the new Horizon stent graft (Endospan, Herzliya, Israel) from two different prospective consecutive trials. The Horizon abdominal aortic aneurysm stent graft system is a 14F profile system requiring only a single access site. It consists of three modules, introduced separately: base limb (iliac to iliac limb); distal aortic limb; and proximal aortic limb with a bare suprarenal crown and active fixation. METHODS: Data from the first in man (FIM) clinical study with 10 patients enrolled and the pivotal study with 30 patients were analyzed. Outcomes measured were freedom from major adverse events (MAEs) including all-cause mortality, myocardial infarction, renal failure, respiratory failure, paraplegia, stroke, bowel ischemia, and procedural blood loss ≥1000 mL. Performance end points included successful delivery and deployment of the device, freedom from aneurysm growth ≥5 mm, type I or type III endoleak, stent graft occlusion, conversion to open surgery, rupture, and stent graft migration. RESULTS: In the FIM study, one conversion to open surgery with >1000 mL of blood loss was registered perioperatively. In the pivotal study, no perioperative MAE was registered. Overall, at 1-year follow-up, two deaths and one aneurysm growth unrelated to endoleak were registered. CONCLUSIONS: The results of both the FIM and pivotal studies demonstrated that 39 of 40 procedures were successful for delivery and deployment of the Horizon stent graft. No MAE was registered during the follow-up. The primary safety and performance end points were met in both studies.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
15.
Eur Radiol ; 28(1): 265-273, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28710583

RESUMO

OBJECTIVE: To investigate the effect of an on-site prototype metal artefact reduction (MAR) algorithm in cone-beam CT-catheter-arteriography (CBCT-CA) in patients undergoing transarterial radioembolisation (RE) of hepatic masses. METHODS AND MATERIALS: Ethical board approved retrospective study of 29 patients (mean 63.7±13.7 years, 11 female), including 16 patients with arterial metallic coils, undergoing CBCT-CA (8s scan, 200 degrees rotation, 397 projections). Image reconstructions with and without prototype MAR algorithm were evaluated quantitatively (streak-artefact attenuation changes) and qualitatively (visibility of hepatic parenchyma and vessels) in near- (<1cm) and far-field (>3cm) of artefact sources (metallic coils and catheters). Quantitative and qualitative measurements of uncorrected and MAR corrected images and different artefact sources were compared RESULTS: Quantitative evaluation showed significant reduction of near- and far-field streak-artefacts with MAR for both artefact sources (p<0.001), while remaining stable for unaffected organs (all p>0.05). Inhomogeneities of attenuation values were significantly higher for metallic coils compared to catheters (p<0.001) and decreased significantly for both after MAR (p<0.001). Qualitative image scores were significantly improved after MAR (all p<0.003) with by trend higher artefact degrees for metallic coils compared to catheters. CONCLUSION: In patients undergoing CBCT-CA for transarterial RE, prototype MAR algorithm improves image quality in proximity of metallic coil and catheter artefacts. KEY POINTS: • Metal objects cause artefacts in cone-beam computed tomography (CBCT) imaging. • These artefacts can be corrected by metal artefact reduction (MAR) algorithms. • Corrected images show significantly better visibility of nearby hepatic vessels and tissue. • Better visibility may facilitate image interpretation, save time and radiation exposure.


Assuntos
Algoritmos , Artefatos , Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia/métodos , Feminino , Humanos , Fígado/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Masculino , Metais , Pessoa de Meia-Idade , Estudos Retrospectivos
16.
J Vasc Interv Radiol ; 29(12): 1725-1732, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30396844

RESUMO

PURPOSE: To evaluate outcome of endovascular elective repair and repair of ruptured isolated iliac artery aneurysms (IIAAs) as a primary treatment strategy. MATERIALS AND METHODS: All patients with an IIAA undergoing endovascular treatment were included. Aneurysms were classified according to an anatomic classification and treated with coiling of the internal iliac artery, stent graft placement in the common to external iliac artery, or placement of a bifurcated aortoiliac stent graft. Between November 1996 and November 2015, 72 patients with 85 IIAAs underwent endovascular repair. Mean age was 73.9 years ± 9.2. Common iliac artery was involved in 63 patients (74.1%), internal iliac artery was involved in 21 patients (24.7%), and external iliac artery was involved in 1 patient (1.2%). Mean diameter was 5 cm (range, 2.5-11 cm). Emergency repair was performed in 19 patients owing to rupture (26.4%). RESULTS: Overall primary technical success rate was 95.8% with conversion rate to open surgery of 4.2% (all in the emergency group) and in-hospital mortality rate of 1.4%. During mean follow-up of 4.3 years ± 3.3 (median 3.8 y; range, 0-14.2 y), 17 endoleaks were observed (6 type I, 10 type II, 1 type IIIa). Overall reintervention rate was 16.7%. Primary patency rate was 98.6%. During the follow-up period, 22 deaths occurred (30.6%), including 2 aneurysm-related deaths (2.8%). CONCLUSIONS: Primary endovascular repair of IIAAs shows excellent results and should be considered as first-line therapy. Surgical backup should be available in emergency cases.


Assuntos
Aneurisma Roto/cirurgia , Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Ilíaco/cirurgia , Artéria Ilíaca/cirurgia , Idoso , Idoso de 80 Anos ou mais , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/mortalidade , Aneurisma Roto/fisiopatologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Conversão para Cirurgia Aberta , Procedimentos Cirúrgicos Eletivos , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/mortalidade , Emergências , Endoleak/mortalidade , Endoleak/cirurgia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/mortalidade , Aneurisma Ilíaco/fisiopatologia , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Masculino , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Stents , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
17.
Vasa ; 47(4): 311-317, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29583101

RESUMO

BACKGROUND: The aim of this study was to evaluate the technical success of percutaneous ultrasound-guided access to the infraclavicular axillary artery with a suture-mediated closing device for patients requiring large-sized upper extremity access. PATIENTS AND METHODS: In 18 consecutive patients (17 male, one female, mean age 73.5 ± 9.6 years, range 52-88 years), artery accesses with the preclosing modification for chimney endografts was gained with 20 ultrasound-guided infraclavicular axillary. Retrospectively, the following endpoints were analysed: technical success of percutaneous ultrasound-guided puncture of the infraclavicular axillary artery as well as introduction and deployment, primary successful haemostasis by preclosing, bailout procedures, overall complication rate including local vascular, cerebrovascular, and peripheral neurological complications. RESULTS: Ultrasound-guided puncture and preclosing procedure was successful in all patients. Mean sheath size was 9.4 ± 1.6 French. Ultrasound-guided puncture as well as introduction and deployment were successful in all patients (100 %). Primary successful haemostasis by preclosing was 70 % (14/20). Postclosing with one or two devices enabled successful haemostasis in another 15 %. Bailout stent graft implantation was necessary in three accesses (15 %), either by transfemoral (n = 2) or transbrachial (n = 1) route. Overall complication rate was 16.5 %, all of them were minor haematomas. CONCLUSIONS: Percutaneous ultrasound-guided infraclavicular axillary artery access with preclosing modification seems feasible and safe. The access related complication rate is low and complications can potentially be managed by endovascular means.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Artéria Axilar , Perda Sanguínea Cirúrgica/prevenção & controle , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Cateterismo Periférico , Procedimentos Endovasculares/instrumentação , Técnicas Hemostáticas/instrumentação , Hemorragia Pós-Operatória/prevenção & controle , Técnicas de Sutura , Dispositivos de Oclusão Vascular , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Aneurisma da Aorta Torácica/diagnóstico por imagem , Artéria Axilar/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Cateterismo Periférico/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Feminino , Técnicas Hemostáticas/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Hemorragia Pós-Operatória/etiologia , Desenho de Prótese , Punções , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Ultrassonografia de Intervenção
18.
Eur Radiol ; 27(2): 454-463, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27221562

RESUMO

OBJECTIVES: To investigate radiation dose and diagnostic performance of C-arm flat-panel CT (FPCT) versus standard multi-detector CT (MDCT) shoulder arthrography using MRI-arthrography as reference standard. METHODS: Radiation dose of two different FPCT acquisitions (5 and 20 s) and standard MDCT of the shoulder were assessed using phantoms and thermoluminescence dosimetry. FPCT arthrographies were performed in 34 patients (mean age 44 ± 15 years). Different joint structures were quantitatively and qualitatively assessed by two independent radiologists. Inter-reader agreement and diagnostic performance were calculated. RESULTS: Effective radiation dose was markedly lower in FPCT 5 s (0.6 mSv) compared to MDCT (1.7 mSv) and FPCT 20 s (3.4 mSv). Contrast-to-noise ratios (CNRs) were significantly (p < 0.05) higher in FPCT 20-s versus 5-s protocols. Inter-reader agreements of qualitative ratings ranged between к = 0.47-1.0. Sensitivities for cartilage and rotator cuff pathologies were low for FPCT 5-s (40 % and 20 %) and moderate for FPCT 20-s protocols (75 % and 73 %). FPCT showed high sensitivity (81-86 % and 89-99 %) for bone and acromioclavicular-joint pathologies. CONCLUSION: Using a 5-s protocol FPCT shoulder arthrography provides lower radiation dose compared to MDCT but poor sensitivity for cartilage and rotator cuff pathologies. FPCT 20-s protocol is moderately sensitive for cartilage and rotator cuff tendon pathology with markedly higher radiation dose compared to MDCT. KEY POINTS: • FPCT shoulder arthrography is feasible with fluoroscopy and CT in one workflow. • A 5-s FPCT protocol applies a lower radiation dose than MDCT. • A 20-s FPCT protocol is moderately sensitive for cartilage and tendon pathology.


Assuntos
Artrografia/instrumentação , Articulação do Ombro/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Imagens de Fantasmas , Estudos Prospectivos , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/normas
19.
Respiration ; 93(3): 207-211, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28110338

RESUMO

We report a rare case of Takayasu's arteritis with isolated pulmonary artery stenosis in the presence of active hepatitis B and latent Mycobacterium tuberculosis infection in a middle-aged Asian woman who initially presented with severe dyspnea on exertion and recurrent syncope, occasional burning chest pains, and fatigue. Therapy of the active hepatitis B and latent M. tuberculosis infection together with a course of methotrexate led to a slight reversal of the symptoms, as angioplasty with or without stenting was not an option. The constellation described here hints at the possible link between hepatitis B and M. tuberculosis infection and the development of Takayasu's arteritis. The case also supports the little evidence available indicating that treatment of active hepatitis B infection could positively influence the course of Takayasu's arteritis.


Assuntos
Hepatite B Crônica/complicações , Tuberculose Latente/complicações , Artéria Pulmonar/diagnóstico por imagem , Estenose de Artéria Pulmonar/diagnóstico por imagem , Arterite de Takayasu/diagnóstico por imagem , Angiografia Digital , Antituberculosos/uso terapêutico , Antivirais/uso terapêutico , Azatioprina/uso terapêutico , Feminino , Fluordesoxiglucose F18 , Glucocorticoides/uso terapêutico , Guanina/análogos & derivados , Guanina/uso terapêutico , Hepatite B Crônica/tratamento farmacológico , Humanos , Imunossupressores/uso terapêutico , Isoniazida/uso terapêutico , Tuberculose Latente/tratamento farmacológico , Imageamento por Ressonância Magnética , Metotrexato/uso terapêutico , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons , Artéria Pulmonar/patologia , Compostos Radiofarmacêuticos , Recidiva , Estenose de Artéria Pulmonar/tratamento farmacológico , Estenose de Artéria Pulmonar/etiologia , Estenose de Artéria Pulmonar/patologia , Arterite de Takayasu/complicações , Arterite de Takayasu/tratamento farmacológico , Arterite de Takayasu/patologia
20.
Vascular ; 25(4): 396-401, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28068871

RESUMO

Purpose Percutaneous remote access for endovascular aortic repair is an advantageous alternative to open access. Previous surgery in the femoral region and the presence of synthetic vascular grafts in the femoral/iliac arteries represent major limitations to percutaneous remote access. The aim of this study was to evaluate an original technique used for enabling percutaneous remote access for thoracic or abdominal endovascular aortic repair in patients with scar tissue and/or a vascular graft in the groin. Methods Twenty-five consecutive patients with a thoracic (11/25; 44%) or an aortic aneurysm (14/25; 66%) and with a synthetic vascular graft in the groin (16/25; 64%) or a redo groin access (9/25; 36%) were managed through the percutaneous remote access. In all patients, a percutaneous transluminal angioplasty balloon was used to predilate the scar tissue and the femoral artery or the synthetic vascular graft after preclosing (ProGlide®; Abbott Vascular, Santa Clara, CA, USA). In 10 patients, requiring a 20 Fr sheath, a 6 mm percutaneous transluminal angioplasty balloon was used; and in the remaining 15, requiring a 24 Fr sheath, an 8 mm percutaneous transluminal angioplasty balloon. Preclosing was exclusively performed using ProGlide®. Mean follow-up was 15 months. Results In all cases, stent-graft deployment was successful. There was one surgical conversion (4%; 1/25) due to bleeding from a femoral anastomosis. Two cases required additional percutaneous maneuvers (postclosing with another system in one patient and endoluminal shielding with stent-graft in the other patient). No pseudoaneurysm or access complication occurred during the follow-up. Conclusions Percutaneous access in redo groins with scar tissue and/or synthetic vascular graft using ultrasound-guided punction, preclosing with ProGlide® system and predilation with percutaneous transluminal angioplasty balloon to introduce large size sheath as used for endovascular aortic repair showed to be feasible, safe and with few local complications.


Assuntos
Angioplastia com Balão/instrumentação , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Cateterismo Periférico/instrumentação , Cicatriz/etiologia , Virilha/irrigação sanguínea , Dispositivos de Acesso Vascular , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Cicatriz/diagnóstico por imagem , Desenho de Equipamento , Feminino , Humanos , Masculino , Resultado do Tratamento , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa