Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Nat Methods ; 18(11): 1294-1303, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34725485

RESUMO

Spheroids are three-dimensional cellular models with widespread basic and translational application across academia and industry. However, methodological transparency and guidelines for spheroid research have not yet been established. The MISpheroID Consortium developed a crowdsourcing knowledgebase that assembles the experimental parameters of 3,058 published spheroid-related experiments. Interrogation of this knowledgebase identified heterogeneity in the methodological setup of spheroids. Empirical evaluation and interlaboratory validation of selected variations in spheroid methodology revealed diverse impacts on spheroid metrics. To facilitate interpretation, stimulate transparency and increase awareness, the Consortium defines the MISpheroID string, a minimum set of experimental parameters required to report spheroid research. Thus, MISpheroID combines a valuable resource and a tool for three-dimensional cellular models to mine experimental parameters and to improve reproducibility.


Assuntos
Biomarcadores Tumorais/genética , Proliferação de Células , Bases de Conhecimento , Neoplasias/patologia , Software , Esferoides Celulares/patologia , Microambiente Tumoral , Técnicas de Cultura de Células/métodos , Regulação Neoplásica da Expressão Gênica , Humanos , Neoplasias/classificação , Neoplasias/metabolismo , RNA-Seq , Reprodutibilidade dos Testes , Esferoides Celulares/imunologia , Esferoides Celulares/metabolismo , Células Tumorais Cultivadas
2.
Sensors (Basel) ; 24(2)2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38257548

RESUMO

Most of the time, the deep analysis of a biological sample requires the acquisition of images at different time points, using different modalities and/or different stainings. This information gives morphological, functional, and physiological insights, but the acquired images must be aligned to be able to proceed with the co-localisation analysis. Practically speaking, according to Aristotle's principle, "The whole is greater than the sum of its parts", multi-modal image registration is a challenging task that involves fusing complementary signals. In the past few years, several methods for image registration have been described in the literature, but unfortunately, there is not one method that works for all applications. In addition, there is currently no user-friendly solution for aligning images that does not require any computer skills. In this work, DS4H Image Alignment (DS4H-IA), an open-source ImageJ/Fiji plugin for aligning multimodality, immunohistochemistry (IHC), and/or immunofluorescence (IF) 2D microscopy images, designed with the goal of being extremely easy to use, is described. All of the available solutions for aligning 2D microscopy images have also been revised. The DS4H-IA source code; standalone applications for MAC, Linux, and Windows; video tutorials; manual documentation; and sample datasets are publicly available.


Assuntos
Ciência de Dados , Documentação , Imuno-Histoquímica , Microscopia de Fluorescência , Imunofluorescência
3.
Int J Mol Sci ; 25(4)2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38396899

RESUMO

The Second International StemNet (Federation of Stem Cell Research Associations) meeting took place on 18-20 October 2023 in Brescia (Italy), with the support of the University of Brescia and the Zooprophylactic Institute of Lombardy and Emilia Romagna. The program of the meeting was articulated in nine sections: (1) Biomedical Communication in Italy: Critical Aspects; (2) StemNet Next Generation Session; (3) Cell-Free Therapies; (4) Tips and Tricks of Research Valorisation; (5) Stem Cells and Cancer; (6) Stem Cells in Veterinary Applications; (7) Stem Cells in Clinical Applications; (8) Organoids and 3D Systems; (9) induced pluripotent stem cells (iPCS) and Gene Therapy. National and International speakers presented their scientific works, inspiring debates and discussions among the attendees. The participation in the meeting was high, especially because of the young researchers who animated all the sessions and the rich poster session.


Assuntos
Células-Tronco Pluripotentes Induzidas , Neoplasias , Humanos , Neoplasias/terapia , Itália , Terapia Genética , Terapia Baseada em Transplante de Células e Tecidos
4.
Int J Mol Sci ; 24(10)2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37240248

RESUMO

The 2022 Italian Mesenchymal Stem Cell Group (Gruppo Italiano Staminali Mesenchimali, GISM) Annual Meeting took place on 20-21 October 2022 in Turin (Italy), with the support of the University of Turin and the City of Health and Science of Turin. The novelty of this year's meeting was its articulation, reflecting the new structure of GISM based on six sections: (1) Bringing advanced therapies to the clinic: trends and strategies, (2) GISM Next Generation, (3) New technologies for 3D culture systems, (4) Therapeutic applications of MSC-EVs in veterinary and human medicine, (5) Advancing MSC therapies in veterinary medicine: present challenges and future perspectives, (6) MSCs: a double-edged sword: friend or foe in oncology. National and international speakers presented their scientific works with the aim of promoting an interactive discussion and training for all attendees. The atmosphere was interactive, where ideas and questions between younger researchers and senior mentors were shared in all moments of the congress.


Assuntos
Oncologia , Células-Tronco Mesenquimais , Humanos , Itália
5.
Int J Mol Sci ; 24(12)2023 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-37373066

RESUMO

The majority of patients with Follicular Lymphoma (FL) experience subsequent phases of remission and relapse, making the disease "virtually" incurable. To predict the outcome of FL patients at diagnosis, various clinical-based prognostic scores have been proposed; nonetheless, they continue to fail for a subset of patients. Gene expression profiling has highlighted the pivotal role of the tumor microenvironment (TME) in the FL prognosis; nevertheless, there is still a need to standardize the assessment of immune-infiltrating cells for the prognostic classification of patients with early or late progressing disease. We studied a retrospective cohort of 49 FL lymph node biopsies at the time of the initial diagnosis using pathologist-guided analysis on whole slide images, and we characterized the immune repertoire for both quantity and distribution (intrafollicular, IF and extrafollicular, EF) of cell subsets in relation to clinical outcome. We looked for the natural killer (CD56), T lymphocyte (CD8, CD4, PD1) and macrophage (CD68, CD163, MA4A4A)-associated markers. High CD163/CD8 EF ratios and high CD56/MS4A4A EF ratios, according to Kaplan-Meier estimates were linked with shorter EFS (event-free survival), with the former being the only one associated with POD24. In contrast to IF CD68+ cells, which represent a more homogeneous population, higher in non-progressing patients, EF CD68+ macrophages did not stratify according to survival. We also identify distinctive MS4A4A+CD163-macrophage populations with different prognostic weights. Enlarging the macrophage characterization and combining it with a lymphoid marker in the rituximab era, in our opinion, may enable prognostic stratification for low-/high-grade FL patients beyond POD24. These findings warrant validation across larger FL cohorts.


Assuntos
Linfoma Folicular , Humanos , Intervalo Livre de Progressão , Linfoma Folicular/genética , Linfoma Folicular/patologia , Estudos Retrospectivos , Recidiva Local de Neoplasia , Rituximab , Microambiente Tumoral
6.
Bioinformatics ; 37(10): 1485-1487, 2021 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-32997742

RESUMO

MOTIVATION: Microscopy images of stained cells and tissues play a central role in most biomedical experiments and routine histopathology. Storing colour histological images digitally opens the possibility to process numerically colour distribution and intensity to extract quantitative data. Among those numerical procedures are colour deconvolution, which enable decomposing an RGB image into channels representing the optical absorbance and transmittance of the dyes when their RGB representation is known. Consequently, a range of new applications become possible for morphological and histochemical segmentation, automated marker localization and image enhancement. AVAILABILITY AND IMPLEMENTATION: Colour deconvolution is presented here in two open-source forms: a MATLAB program/function and an ImageJ plugin written in Java. Both versions run in Windows, Macintosh and UNIX-based systems under the respective platforms. Source code and further documentation are available at: https://blog.bham.ac.uk/intellimic/g-landini-software/colour-deconvolution-2/. SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.


Assuntos
Corantes , Software , Cor , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Microscopia
7.
Bioinformatics ; 36(9): 2948-2949, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31950986

RESUMO

SUMMARY: Segmentation of single cells in microscopy images is one of the major challenges in computational biology. It is the first step of most bioimage analysis tasks, and essential to create training sets for more advanced deep learning approaches. Here, we propose 3D-Cell-Annotator to solve this task using 3D active surfaces together with shape descriptors as prior information in a semi-automated fashion. The software uses the convenient 3D interface of the widely used Medical Imaging Interaction Toolkit (MITK). Results on 3D biological structures (e.g. spheroids, organoids and embryos) show that the precision of the segmentation reaches the level of a human expert. AVAILABILITY AND IMPLEMENTATION: 3D-Cell-Annotator is implemented in CUDA/C++ as a patch for the segmentation module of MITK. The 3D-Cell-Annotator enabled MITK distribution can be downloaded at: www.3D-cell-annotator.org. It works under Windows 64-bit systems and recent Linux distributions even on a consumer level laptop with a CUDA-enabled video card using recent NVIDIA drivers. SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.


Assuntos
Imageamento Tridimensional , Microscopia , Biologia Computacional , Humanos , Software
8.
Sensors (Basel) ; 21(11)2021 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-34070896

RESUMO

During the COVID-19 pandemic, there has been a significant increase in the use of non-contact infrared devices for screening the body temperatures of people at the entrances of hospitals, airports, train stations, churches, schools, shops, sports centres, offices, and public places in general. The strong correlation between a high body temperature and SARS-CoV-2 infection has motivated the governments of several countries to restrict access to public indoor places simply based on a person's body temperature. Negating/allowing entrance to a public place can have a strong impact on people. For example, a cancer patient could be refused access to a cancer centre because of an incorrect high temperature measurement. On the other hand, underestimating an individual's body temperature may allow infected patients to enter indoor public places where it is much easier for the virus to spread to other people. Accordingly, during the COVID-19 pandemic, the reliability of body temperature measurements has become fundamental. In particular, a debated issue is the reliability of remote temperature measurements, especially when these are aimed at identifying in a quick and reliable way infected subjects. Working distance, body-device angle, and light conditions and many other metrological and subjective issues significantly affect the data acquired via common contactless infrared point thermometers, making the acquisition of reliable measurements at the entrance to public places a challenging task. The main objective of this work is to sensitize the community to the typical incorrect uses of infrared point thermometers, as well as the resulting drifts in measurements of body temperature. Using several commercial contactless infrared point thermometers, we performed four different experiments to simulate common scenarios in a triage emergency room. In the first experiment, we acquired several measurements for each thermometer without measuring the working distance or angle of inclination to show that, for some instruments, the values obtained can differ by 1 °C. In the second and third experiments, we analysed the impacts of the working distance and angle of inclination of the thermometers, respectively, to prove that only a few cm/degrees can cause drifts higher than 1 °C. Finally, in the fourth experiment, we showed that the light in the environment can also cause changes in temperature up to 0.5 °C. Ultimately, in this study, we quantitatively demonstrated that the working distance, angle of inclination, and light conditions can strongly impact temperature measurements, which could invalidate the screening results.


Assuntos
COVID-19 , Termômetros , Temperatura Corporal , Humanos , Raios Infravermelhos , Pandemias , Reprodutibilidade dos Testes , SARS-CoV-2
9.
Sensors (Basel) ; 20(21)2020 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-33167361

RESUMO

Fitness sensors and health systems are paving the way toward improving the quality of medical care by exploiting the benefits of new technology. For example, the great amount of patient-generated health data available today gives new opportunities to measure life parameters in real time and create a revolution in communication for professionals and patients. In this work, we concentrated on the basic parameter typically measured by fitness applications and devices-the number of steps taken daily. In particular, the main goal of this study was to compare the accuracy and precision of smartphone applications versus those of wearable devices to give users an idea about what can be expected regarding the relative difference in measurements achieved using different system typologies. In particular, the data obtained showed a difference of approximately 30%, proving that smartphone applications provide inaccurate measurements in long-term analysis, while wearable devices are precise and accurate. Accordingly, we challenge the reliability of previous studies reporting data collected with phone-based applications, and besides discussing the current limitations, we support the use of wearable devices for mHealth.


Assuntos
Exercício Físico , Aplicativos Móveis , Dispositivos Eletrônicos Vestíveis , Humanos , Reprodutibilidade dos Testes , Telemedicina
10.
Nat Methods ; 12(5): 404-6, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25775044

RESUMO

Uneven illumination affects every image acquired by a microscope. It is often overlooked, but it can introduce considerable bias to image measurements. The most reliable correction methods require special reference images, and retrospective alternatives do not fully model the correction process. Our approach overcomes these issues for most optical microscopy applications without the need for reference images.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Luz , Microscopia/métodos , Software
11.
Biol Proced Online ; 19: 8, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28814944

RESUMO

BACKGROUND: Whatever the target of an experiment in cell biology, cell counting and viability assessment are always computed. The Trypan Blue (TB) assay was proposed about a century ago and is still the most widely used method to perform cell viability analysis. Furthermore, the combined use of TB with a haemocytometer is also considered the standard approach to estimate cell population density. There are numerous research articles reporting the use of TB assays to compute cell number and viability of 2D and 3D cultures. However, the literature still lacks studies regarding the reliability of the TB assay in terms of assessment of its repeatability and reproducibility. METHODS: We compared the TB assay's measurements obtained by two biologists who analysed 105 different samples in double-blind for a total of 210 counts performed. We measured: (a) the repeatability of the count performed by the same operator; (b) the reproducibility of counts performed by the two operators. RESULTS: There were no significant differences in the results obtained with 2D and 3D cell cultures: we estimated an approximate variability of 5% when the TB assay was used to assess the viability of the culture, and a variability of around 20% when it was used to determine the cell population density. CONCLUSIONS: The main aim of this study was to make researchers aware of potential measurement errors when TB is used with a haemocytometer for counting and viability measurements in 2D and 3D cultures. We believe that these results can help researchers to determine whether the expected reliability of the TB assay is compliant with their applications.

12.
Bioinformatics ; 32(6): 955-7, 2016 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-26589273

RESUMO

MOTIVATION: Time-lapse experiments play a key role in studying the dynamic behavior of cells. Single-cell tracking is one of the fundamental tools for such analyses. The vast majority of the recently introduced cell tracking methods are limited to fluorescently labeled cells. An equally important limitation is that most software cannot be effectively used by biologists without reasonable expertise in image processing. Here we present CellTracker, a user-friendly open-source software tool for tracking cells imaged with various imaging modalities, including fluorescent, phase contrast and differential interference contrast (DIC) techniques. AVAILABILITY AND IMPLEMENTATION: CellTracker is written in MATLAB (The MathWorks, Inc., USA). It works with Windows, Macintosh and UNIX-based systems. Source code and graphical user interface (GUI) are freely available at: http://celltracker.website/ CONTACT: horvath.peter@brc.mta.hu SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.


Assuntos
Software , Processamento de Imagem Assistida por Computador
13.
J Mater Sci Mater Med ; 25(10): 2395-410, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24863020

RESUMO

The analysis of cell confluence and proliferation is essential to design biomaterials and scaffolds to use as bone substitutes in clinical applications. Accordingly, several approaches have been proposed in the literature to estimate the area of the scaffold covered by cells. Nevertheless, most of the approaches rely on sophisticated equipment not employed for routine analyses, while the rest of them usually do not provide significant statistics about the cell distribution. This research aims at studying confluence and proliferation of mesenchymal stromal cells (MSC) adherent on OSPROLIFE(®), a commercial biomaterial in the form of granules. In particular, we propose a Computer Vision approach that can routinely be employed to monitor the surface of the single granules covered by cells because only a standard widefield fluorescent microscope is required. In order to acquire significant statistics data, we analyse wide-area images built by using MicroMos v2.0, an updated version of a previously published software specific for stitching brightfield and phase-contrast images manually acquired via a widefield microscope. In particular, MicroMos v2.0 permits to build accurate "mosaics" of fluorescent images, after correcting vignetting and photo-bleaching effects, providing a consistent representation of a sample region containing numerous granules. Then, our method allows to make automatically a statistically significant estimate of the percentage of the area of the single granules covered by cells. Finally, by analysing hundreds of granules at different time intervals we also obtained reliable data regarding cell proliferation, confirming that not only MSC adhere onto the OSPROLIFE(®) granules, but even proliferate over time.


Assuntos
Fosfatos de Cálcio/farmacologia , Células-Tronco Mesenquimais/efeitos dos fármacos , Células-Tronco Mesenquimais/fisiologia , Substitutos Ósseos/química , Adesão Celular , Comunicação Celular , Proliferação de Células/efeitos dos fármacos , Células Cultivadas , Humanos , Processamento de Imagem Assistida por Computador , Células-Tronco Mesenquimais/ultraestrutura , Microscopia de Fluorescência/métodos , Tamanho da Partícula , Propriedades de Superfície , Alicerces Teciduais/química
14.
Int J Biol Macromol ; 265(Pt 1): 130854, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38484814

RESUMO

Monocarboxylate transporter-1 (MCT-1) inhibitors were screened from the Fv-antibody library, which contained complementary determining region 3 with randomized amino acid sequences (11 residues) through site-directed mutagenesis. Fv-antibodies against MCT-1 were screened from the autodisplayed Fv-antibody library. Two clones were screened, and the binding affinity (KD) against MCT-1 was estimated using flow cytometry. The screened Fv-antibodies were expressed as soluble fusion proteins (Fv-1 and Fv-2) and the KD for MCT-1 was estimated using the SPR biosensor. The inhibitory activity of the expressed Fv-antibodies was observed in HEK293T and Jurkat cell lines by measuring intracellular pH and lactate accumulation. The level of cell viability in HEK293T and Jurkat cell lines was decreased by the inhibitory activity of the expressed Fv-antibodies. The binding properties of the Fv-antibodies to MCT-1 were analyzed using molecular docking simulations. Overall, the results showed that the screened Fv-antibodies against MCT-1 from the Fv-antibody library had high binding affinity and inhibitory activity against MCT-1, which could be used as potential therapeutic drug candidates for the MCT-1 inhibitor.


Assuntos
Anticorpos , Proteínas de Transporte , Humanos , Simulação de Acoplamento Molecular , Células HEK293 , Sequência de Aminoácidos , Biblioteca Gênica
15.
Front Bioeng Biotechnol ; 12: 1339723, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38357706

RESUMO

Introduction: In several fields, the process of fusing multiple two-dimensional (2D) closed lines is an important step. For instance, this is fundamental in histology and oncology in general. The treatment of a tumor consists of numerous steps and activities. Among them, segmenting the cancer area, that is, the correct identification of its spatial location by the segmentation technique, is one of the most important and at the same time complex and delicate steps. The difficulty in deriving reliable segmentations stems from the lack of a standard for identifying the edges and surrounding tissues of the tumor area. For this reason, the entire process is affected by considerable subjectivity. Given a tumor image, different practitioners can associate different segmentations with it, and the diagnoses produced may differ. Moreover, experimental data show that the analysis of the same area by the same physician at two separate timepoints may result in different lines being produced. Accordingly, it is challenging to establish which contour line is the ground truth. Methods: Starting from multiple segmentations related to the same tumor, statistical metrics and computational procedures could be exploited to combine them for determining the most reliable contour line. In particular, numerous algorithms have been developed over time for this procedure, but none of them is validated yet. Accordingly, in this field, there is no ground truth, and research is still active. Results: In this work, we developed the Two-Dimensional Segmentation Fusion Tool (TDSFT), a user-friendly tool distributed as a free-to-use standalone application for MAC, Linux, and Windows, which offers a simple and extensible interface where numerous algorithms are proposed to "compute the mean" (i.e., the process to fuse, combine, and "average") multiple 2D lines. Conclusions: The TDSFT can support medical specialists, but it can also be used in other fields where it is required to combine 2D close lines. In addition, the TDSFT is designed to be easily extended with new algorithms thanks to a dedicated graphical interface for configuring new parameters. The TDSFT can be downloaded from the following link: https://sourceforge.net/p/tdsft.

16.
Cells ; 12(5)2023 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-36899938

RESUMO

Prostate cancer (PCa) is one of the most common cancers in European males. Although therapeutic approaches have changed in recent years, and several new drugs have been approved by the Food and Drug Administration (FDA), androgen deprivation therapy (ADT) remains the standard of care. Currently, PCa represents a clinical and economic burden due to the development of resistance to ADT, paving the way to cancer progression, metastasis, and to long-term side effects induced by ADT and radio-chemotherapeutic regimens. In light of this, a growing number of studies are focusing on the tumor microenvironment (TME) because of its role in supporting tumor growth. Cancer-associated fibroblasts (CAFs) have a central function in the TME because they communicate with prostate cancer cells, altering their metabolism and sensitivity to drugs; hence, targeted therapy against the TME, and, in particular, CAFs, could represent an alternative therapeutic approach to defeat therapy resistance in PCa. In this review, we focus on different CAF origins, subsets, and functions to highlight their potential in future therapeutic strategies for prostate cancer.


Assuntos
Fibroblastos Associados a Câncer , Neoplasias da Próstata , Estados Unidos , Masculino , Humanos , Neoplasias da Próstata/patologia , Fibroblastos Associados a Câncer/metabolismo , Antagonistas de Androgênios/uso terapêutico , Resistencia a Medicamentos Antineoplásicos , Próstata/patologia , Microambiente Tumoral
17.
Biomater Sci ; 11(22): 7432-7444, 2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-37819086

RESUMO

Developing physiologically relevant in vitro models for studying periodontitis is crucial for understanding its pathogenesis and developing effective therapeutic strategies. In this study, we aimed to integrate the spheroid culture of periodontal ligament stem cells (PDLSCs) within a spheroid-on-chip microfluidic perfusion platform and to investigate the influence of interstitial fluid flow on morphogenesis, cellular viability, and osteogenic differentiation of PDLSC spheroids. PDLSC spheroids were seeded onto the spheroid-on-chip microfluidic device and cultured under static and flow conditions. Computational analysis demonstrated the translation of fluid flow rates of 1.2 µl min-1 (low-flow) and 7.2 µl min-1 (high-flow) to maximum fluid shear stress of 59 µPa and 360 µPa for low and high-flow conditions, respectively. The spheroid-on-chip microfluidic perfusion platform allowed for modulation of flow conditions leading to larger PDLSC spheroids with improved cellular viability under flow compared to static conditions. Modulation of fluid flow enhanced the osteodifferentiation potential of PDLSC spheroids, demonstrated by significantly enhanced alizarin red staining and alkaline phosphatase expression. Additionally, flow conditions, especially high-flow conditions, exhibited extensive calcium staining across both peripheral and central regions of the spheroids, in contrast to the predominantly peripheral staining observed under static conditions. These findings highlight the importance of fluid flow in shaping the morphological and functional properties of PDLSC spheroids. This work paves the way for future investigations exploring the interactions between PDLSC spheroids, microbial pathogens, and biomaterials within a controlled fluidic environment, offering insights for the development of innovative periodontal therapies, tissue engineering strategies, and regenerative approaches.


Assuntos
Osteogênese , Ligamento Periodontal , Osteogênese/fisiologia , Células-Tronco/metabolismo , Diferenciação Celular , Microfluídica , Células Cultivadas
18.
Biosensors (Basel) ; 13(2)2023 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-36831953

RESUMO

Nowadays, morphology and molecular analyses at the single-cell level have a fundamental role in understanding biology better. These methods are utilized for cell phenotyping and in-depth studies of cellular processes, such as mitosis. Fluorescence microscopy and optical spectroscopy techniques, including Raman micro-spectroscopy, allow researchers to examine biological samples at the single-cell level in a non-destructive manner. Fluorescence microscopy can give detailed morphological information about the localization of stained molecules, while Raman microscopy can produce label-free images at the subcellular level; thus, it can reveal the spatial distribution of molecular fingerprints, even in live samples. Accordingly, the combination of correlative fluorescence and Raman microscopy (CFRM) offers a unique approach for studying cellular stages at the single-cell level. However, subcellular spectral maps are complex and challenging to interpret. Artificial intelligence (AI) may serve as a valuable solution to characterize the molecular backgrounds of phenotypes and biological processes by finding the characteristic patterns in spectral maps. The major contributions of the manuscript are: (I) it gives a comprehensive review of the literature focusing on AI techniques in Raman-based cellular phenotyping; (II) via the presentation of a case study, a new neural network-based approach is described, and the opportunities and limitations of AI, specifically deep learning, are discussed regarding the analysis of Raman spectroscopy data to classify mitotic cellular stages based on their spectral maps.


Assuntos
Inteligência Artificial , Análise Espectral Raman , Microscopia de Fluorescência/métodos , Análise Espectral Raman/métodos
19.
Front Oncol ; 13: 1136331, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37287922

RESUMO

Gastro-entero-pancreatic neuroendocrine tumors (GEP-NETs) are rare diseases encompassing pancreatic (PanNETs) and ileal NETs (SINETs), characterized by heterogeneous somatostatin receptors (SSTRs) expression. Treatments for inoperable GEP-NETs are limited, and SSTR-targeted Peptide Receptor Radionuclide Therapy (PRRT) achieves variable responses. Prognostic biomarkers for the management of GEP-NET patients are required. 18F-FDG uptake is a prognostic indicator of aggressiveness in GEP-NETs. This study aims to identify circulating and measurable prognostic miRNAs associated with 18F-FDG-PET/CT status, higher risk and lower response to PRRT. Methods: Whole miRNOme NGS profiling was conducted on plasma samples obtained from well-differentiated advanced, metastatic, inoperable G1, G2 and G3 GEP-NET patients enrolled in the non-randomized LUX (NCT02736500) and LUNET (NCT02489604) clinical trials prior to PRRT (screening set, n= 24). Differential expression analysis was performed between 18F-FDG positive (n=12) and negative (n=12) patients. Validation was conducted by Real Time quantitative PCR in two distinct well-differentiated GEP-NET validation cohorts, considering the primary site of origin (PanNETs n=38 and SINETs n=30). The Cox regression was applied to assess independent clinical parameters and imaging for progression-free survival (PFS) in PanNETs. In situ RNA hybridization combined with immunohistochemistry was performed to simultaneously detect miR and protein expression in the same tissue specimens. This novel semi-automated miR-protein protocol was applied in PanNET FFPE specimens (n=9). In vitro functional experiments were performed in PanNET models. Results: While no miRNAs emerged to be deregulated in SINETs, hsa-miR-5096, hsa-let-7i-3p and hsa-miR-4311 were found to correlate with 18F-FDG-PET/CT in PanNETs (p-value:<0.005). Statistical analysis has shown that, hsa-miR-5096 can predict 6-month PFS (p-value:<0.001) and 12-month Overall Survival upon PRRT treatment (p-value:<0.05), as well as identify 18F-FDG-PET/CT positive PanNETs with worse prognosis after PRRT (p-value:<0.005). In addition, hsa-miR-5096 inversely correlated with both SSTR2 expression in PanNET tissue and with the 68Gallium-DOTATOC captation values (p-value:<0.05), and accordingly it was able to decrease SSTR2 when ectopically expressed in PanNET cells (p-value:<0.01). Conclusions: hsa-miR-5096 well performs as a biomarker for 18F-FDG-PET/CT and as independent predictor of PFS. Moreover, exosome-mediated delivery of hsa-miR-5096 may promote SSTR2 heterogeneity and thus resistance to PRRT.

20.
Sci Data ; 9(1): 412, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-35840608

RESUMO

In a clinical contest, it is common to use dedicated phantoms to perform quality assurance test to check the performance of a SPECT system. Some of these phantoms are also used to calibrate the system for dosimetric evaluation of patients undergoing radiometabolic cancer therapy. In this work, a 3D-OSEM reconstructed 177Lu SPECT dataset of a homogeneous cylindrical phantom is described. This dataset was acquired to investigate the variation of the SPECT calibration factor, counts convergence, noise and uniformity by varying the number of subsets and iterations. In particular, the dataset is composed of images reconstructed using five different numbers of subsets and sixteen different numbers of iterations, for a total of 80 different configurations. The dataset is suitable for comparison with other reconstruction algorithms (e.g. FBP, MLEM, etc.) and radionuclides (e.g. technetium, yttrium). In regards to the uniformity issue, the same dataset allows the user to perform radiomic investigations on the influence of the border effect on the reconstructed images.


Assuntos
Algoritmos , Tomografia Computadorizada de Emissão de Fóton Único , Calibragem , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único/métodos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa