Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Imaging ; 8(2)2022 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-35200724

RESUMO

The TRIMAGE project aims to develop a brain-dedicated PET/MR/EEG (Positron Emission Tomography/Magnetic Resonance/Electroencephalogram) system that is able to perform simultaneous PET, MR and EEG acquisitions. The PET component consists of a full ring with 18 sectors. Each sector includes three square detector modules based on dual sstaggered LYSO:Ce matrices read out by SiPMs. Using Monte Carlo simulations and following NEMA (National Electrical Manufacturers Association) guidelines, image quality procedures have been applied to evaluate the performance of the PET component of the system. The performance are reported in terms of spatial resolution, uniformity, recovery coefficient, spill over ratio, noise equivalent count rate (NECR) and scatter fraction. The results show that the TRIMAGE system is at the top of the current brain PET technologies.

2.
EJNMMI Phys ; 9(1): 10, 2022 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-35122556

RESUMO

BACKGROUND: Non-human primates (NHP) are critical in biomedical research to better understand the pathophysiology of diseases and develop new therapies. Based on its translational and longitudinal abilities along with its non-invasiveness, PET/CT systems dedicated to non-human primates can play an important role for future discoveries in medical research. The aim of this study was to evaluate the performance of a new PET/CT system dedicated to NHP imaging, the IRIS XL-220 developed by Inviscan SAS. This was performed based on the National Electrical Manufacturers Association (NEMA) NU 4-2008 standard recommendations (NEMA) to characterize the spatial resolution, the scatter fraction, the sensitivity, the count rate, and the image quality of the system. Besides, the system was evaluated in real conditions with two NHP with 18F-FDG and (-)-[18F]FEOBV which targets the vesicular acetylcholine transporter, and one rat using 18F-FDG. RESULTS: The full width at half maximum obtained with the 3D OSEM algorithm ranged between 0.89 and 2.11 mm in the field of view. Maximum sensitivity in the 400-620 keV and 250-750 keV energy windows were 2.37% (22 cps/kBq) and 2.81% (25 cps/kBq), respectively. The maximum noise equivalent count rate (NEC) for a rat phantom was 82 kcps at 75 MBq and 88 kcps at 75 MBq for energy window of 250-750 and 400-620 keV, respectively. For the monkey phantom, the maximum NEC was 18 kcps at 126 MBq and 19 kcps at 126 MBq for energy window of 250-750 and 400-620 keV, respectively. The IRIS XL provided an excellent quality of images in non-human primates and rats using 18F-FDG. The images acquired using (-)-[18F]FEOBV were consistent with those previously reported in non-human primates. CONCLUSIONS: Taken together, these results showed that the IRIS XL-220 is a high-resolution system well suited for PET/CT imaging in non-human primates.

3.
Phys Med ; 57: 107-114, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30738514

RESUMO

PET preclinical studies require high spatial resolution due to the limited size of the animal under investigation. To achieve this target, iterative image reconstruction algorithms are commonly preferred over the analytical methods because they offer the possibility of accurately modeling the whole imaging process. In this work, we propose an accurate factorized system matrix for the INVISCAN IRIS preclinical PET scanner to be used with an iterative algorithm. The model includes two components: the geometric component and the detector response of the system. The main innovative aspect of the work is the creation of the detector matrix using a Monte Carlo simulation, with a particular focus on the optimization of the simulation process to reduce the calculation time. The new system model is compared with the current IRIS model to evaluate the image quality, following the NEMA Standards NU 4-2008. The comparison showed an enhancement of the image quality, in terms of uniformity and recovery coefficients. This work confirms that the inclusion of the detector response into the system model leads to improved reconstruction results.


Assuntos
Modelos Teóricos , Método de Monte Carlo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/instrumentação , Algoritmos , Animais , Processamento de Imagem Assistida por Computador
4.
ACS Nano ; 4(2): 841-8, 2010 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-20112970

RESUMO

The temperature and thickness dependence of the thermal expansivity of ultrathin thin films of poly(tert-butylstyrene) capped between aluminum layers revealed an unusual and intriguing confinement scenario. Below 50 nm, both the glass transition temperature and the thermal expansion coefficients decreased. Such a mixed behavior implies an enhancement of the molecular mobility, without the presence of any free surface, but dead layers. On the basis of a careful analysis of averaged quantities measured by capacitive dilatometry, we deduced a profile of thermal expansivity that explains our experimental data and previous observations in polymer nanocomposites. The effect of density-conformation coupling in proximity of a nonattractive interface allows the coexistence of an immobilized fraction in direct contact with the metal and an excess of thermal expansivity, arising from the long-range effects of packing frustration penetrating inside the bulk-like core of the film.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa