Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
Eur J Clin Invest ; 51(6): e13473, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33326601

RESUMO

BACKGROUND: Percutaneous mitral valve repair (PMVR) is a therapeutic option for severe mitral regurgitation (MR) in patients with heart failure due to differential aetiologies. However, only little is known about the safety and efficacy of this procedure in patients with amyloid cardiomyopathy. METHODS: Five patients with cardiac amyloidosis and moderate to severe or severe MR undergoing PMVR were analysed retrospectively and compared to seven patients with cardiac amyloidosis and severe MR without intervention. Clinical and functional data, renal function and cardiac biomarkers as well as established risk scores for cardiac amyloidosis were assessed. Primary endpoint was the reduction in MR one year after PMVR. Secondary endpoints were safety, overall mortality after 12 months compared with the control group, as well as changes in clinical and functional parameters. RESULTS: Amyloidosis risk assessment documented amyloid cardiomyopathy at an advanced stage in all patients. Procedural, technical and device success of PMVR were all 100% and residual MR remained mild to moderate at 12 months follow-up (P = .038 vs before PMVR). Differences in survival compared with the control (no PMVR) group pointed to a possible survival benefit in the PMVR group (P = .02). CONCLUSION: PMVR is a feasible and safe procedure in patients with cardiac amyloidosis and might carry a possible survival benefit in this patient group.


Assuntos
Amiloidose/fisiopatologia , Cateterismo Cardíaco/métodos , Cardiomiopatias/fisiopatologia , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Amiloidose/complicações , Cardiomiopatias/complicações , Feminino , Humanos , Masculino , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/fisiopatologia , Estudos Retrospectivos , Resultado do Tratamento
2.
Herz ; 46(Suppl 1): 54-60, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31773184

RESUMO

BACKGROUND: Patients with reduced left ventricular (LV) function undergoing coronary artery bypass graft surgery or/and aortic valve replacement occasionally show severe mitral valve (MV) regurgitation and thus also undergo surgical mitral annuloplasty. Over time, further deterioration of LV function and additional ischemic events cause recurrence of severe MV regurgitation due to the Carpentier IIIb morphology of the MV that is not adequately addressed by the previously implanted annuloplasty ring. METHODS: Seven patients (Society of Thoracic Surgeons score: 7.5 ± 1.5%) with Carpentier type-IIIb recurrent severe MV regurgitation, having undergone prior cardiothoracic surgery (median: 40 months) including mitral annuloplasty, were treated with the MitraClip device. RESULTS: MitraClip implantation resulted in significantly reduced MV regurgitation and improved New York Heart Association functional state, translating into an increased exercise capability and improved cardiac biomarkers. The morphology of the MV was adequately addressed without causing relevant MV stenosis, while the MV annulus area remained unaltered. The procedure was safe with a 30-day mortality rate of 0%. CONCLUSION: MitraClip-in-the-ring is feasible and in principle safe for treating Carpentier type IIIb severe MV regurgitation after surgical MV repair using mitral annuloplasty. MitraClip-in-the-ring resulted in immediate amelioration of clinical symptoms and increased physical exercise capacity.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 96(3): 578-585, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31638330

RESUMO

OBJECTIVES: To evaluate myocardial injury and infarction (MI) following elective percutaneous coronary intervention (PCI). BACKGROUND: The substantially higher analytical power of high-sensitivity troponin (hsTn) assays allows detection of minor cardiac troponin (cTn) levels, which may be useful in monitoring myocardial injury and guiding therapies. METHODS: Serial hsTnT measurements were conducted in patients undergoing elective PCI and were related to the extent of coronary artery disease (CAD) as reflected by the SYNTAX score risk categories and American College of Cardiology/American Heart Association classification of coronary lesions. Myocardial injury and MI were diagnosed according to the second and third versions of universal MI definition. RESULTS: The study population consisted of 530 patients, who were grouped into low (41.3%), intermediate (35.4%), and high (23.3%) SYNTAX risk categories. The treated coronary lesions were classified into A 7.8%, B1 24.1%, B2 21.1%, C1 24.6%, and C2 22.4%. Postprocedural hsTnT increases correlated significantly with the complexity of treated coronary lesions (p < .05) and CAD magnitude (p < .05). Rates of MI type 4a according to the second and third MI definition criteria were 98 (27.5%) and 15 (4.2%) cases in patients with normal baseline hsTnT values (N = 357, 67.4%), as well as 137 (79.2%) and 27 (15.6%) cases in those with elevated baseline hsTnT values (N = 173, 32.6%), respectively. CONCLUSIONS: After elective PCI, cTn releases correlate significantly with lesion complexity and CAD extent. Use of hsTnT assay enables precise monitoring of PCI-related myocardial injury and may identify patients at higher risk for ischemic events, who may benefit from potent platelet inhibition, which needs to be investigated in randomized trials.


Assuntos
Doença da Artéria Coronariana/terapia , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Troponina T/sangue
4.
J Interv Cardiol ; 31(1): 76-82, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29027267

RESUMO

OBJECTIVES: The aim of this study was to assess feasibility and clinical effectiveness of the MitraClip device in octogenarians suffering from severe mitral valve regurgitation due to chordae rupture. BACKGROUND: The MitraClip procedure is a suitable technique in high-risk surgical patients to achieve safe and effective percutaneous repair of mitral valve regurgitation. Octogenarians show cumulative risk and social aspects hindering mitral valve surgery. No data exists regarding the use of the MitraClip device in high-risk octogenarians suffering from mitral valve chordae rupture. METHODS: Between October 2009 and March 2017 98 high-risk octogenarians (society of thoracic surgeons score [STS]: 9.7% ± 0.8) with mitral valve prolapse and consecutively chordae rupture were treated with the MitraClip after interdisciplinary discussion. RESULTS: Successful mitral valve repair was achieved in 91% of the octogenarians. Repair of the mitral valve caused immediate and significant reduction of dyspnoea (NYHA class: 3.5 ± 0.4 vs 2.0 ± 0.3; P < 0.001), cardiac reverse remodeling (LVESD: 39 ± 0.8 vs 35 ± 0.8; P < 0.01) and amelioration of cardiac biomarkers (NTproBNP (4884 ± 52 ng/L vs 2473 ± 210 ng/L; P < 0.05,). Effects were stable over the 12 months observation period. None of our patients died intraprocedurally. CONCLUSIONS: Percutaneous repair of chordae rupture is feasible and safe in high-risk octogenarians. The MitraClip should be considered to repair severe mitral valve regurgitation due to mitral valve chordae rupture in high-risk octogenarians after interdisciplinary discussion even facing a challenging anatomy.


Assuntos
Implante de Prótese de Valva Cardíaca , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Risco Ajustado/métodos , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Valva Mitral/patologia , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
5.
Acta Cardiol ; 73(4): 378-386, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29161956

RESUMO

BACKGROUND: Occurrence of severe mitral valve (MV) regurgitation (MR) is an independent negative predictor of mortality in patients with severe systolic heart failure (HF). This study examines clinical effects and cardiac reverse remodelling in patients with severe systolic HF receiving percutaneous mitral valve repair (PMVR) using MitraClip in comparison to patients receiving optimal medical therapy only. METHODS: Between 2010 and 2014, 86 patients (Society of Thoracic Surgeons score: 10.5% ± 1.2%) with severe HF (left ventricular [LV] ejection fraction; LVEF: 25% ± 2%; LV endsystolic diameter [LVESD]: 55 ± 3 mm) and severe MR received PMVR using MitraClip. Cardiac reverse remodelling and clinical parameters were compared to HF patients with severe MR (from our HF outpatient clinic; n = 69; LVEF: 26% ± 1.4%; LVESD: 53 ± 2 mm) receiving optimal medical therapy (OMT) only. All patients received stable OMT and were characterised by echocardiography, 6-minwalk-distance test and cardiac biomarkers within a 24 months observation period. RESULTS: PMVR in patients with end-stage HF and severe MR resulted in reduction of MR and significant additional cardiac reverse remodelling (LVEF: 26 ± 1.4 vs. 33% ± 2%, p < .05; LVESD: 53 ± 2 vs. 47 ± 2 mm, p < .05) over the 24 months observation period as compared to pharmacologically-only managed comparators. CONCLUSIONS: Both OMT and PMVR cause cardiac reverse remodelling and relief of symptoms in patients with HF and severe MR. PMVR results in significant additional cardiac reverse remodelling compared to pharmacologically-only managed patients.


Assuntos
Antagonistas Adrenérgicos beta/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/complicações , Implante de Prótese de Valva Cardíaca/métodos , Antagonistas de Receptores de Mineralocorticoides/uso terapêutico , Insuficiência da Valva Mitral/cirurgia , Idoso , Ecocardiografia , Feminino , Seguimentos , Alemanha/epidemiologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico , Estudos Retrospectivos , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
6.
Psychosom Med ; 78(4): 432-42, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26705072

RESUMO

OBJECTIVES: Heart failure (HF) is a prevalent disease that remains costly and associated with a high mortality rate. HF is also associated with poor neurocognitive functioning. For the treatment for HF patients with severe mitral regurgitation, the MitraClip device has emerged as a promising interventional tool that reduces the mitral valve leakage and thus increases cardiac output. Currently, there is only limited knowledge on changes in cognitive and psychosocial functioning before and after the MitraClip intervention. METHODS: Cognitive function (memory and executive function) and psychosocial measures (depression, anxiety, and quality of life) were assessed before and after the MitraClip intervention in 24 HF patients and 23 healthy participants (comparison group). RESULTS: MitraClip intervention in HF patients was followed by improvements in figural long-term memory (p = .003) and executive function (planning ability, p < .001) relative to the comparison group. In addition, the intervention resulted in a significant improvement in depression (p = .002), anxiety (p = .003) and quality of life scores (physical p = .017, mental p = .013) as well as improved 6-minute walk test results over time (p = .002). CONCLUSIONS: The presented data provide evidence of a significant improvement in memory and executive function as well as in depression, anxiety, and quality of life scores in patients with chronic HF after MitraClip intervention. Further research is needed to shed light on the long-term development of cognitive function, psychosocial well-being, and clinical parameters after MitraClip intervention and how these factors depend on one another.


Assuntos
Ansiedade/psicologia , Depressão/psicologia , Função Executiva/fisiologia , Insuficiência Cardíaca/terapia , Implante de Prótese de Valva Cardíaca/psicologia , Memória de Longo Prazo/fisiologia , Insuficiência da Valva Mitral/terapia , Avaliação de Resultados em Cuidados de Saúde , Qualidade de Vida/psicologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade
7.
Mol Ther ; 23(8): 1320-1330, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26005840

RESUMO

Restoring expression levels of the EF-hand calcium (Ca(2+)) sensor protein S100A1 has emerged as a key factor in reconstituting normal Ca(2+) handling in failing myocardium. Improved sarcoplasmic reticulum (SR) function with enhanced Ca(2+) resequestration appears critical for S100A1's cyclic adenosine monophosphate-independent inotropic effects but raises concerns about potential diastolic SR Ca(2+) leakage that might trigger fatal arrhythmias. This study shows for the first time a diminished interaction between S100A1 and ryanodine receptors (RyR2s) in experimental HF. Restoring this link in failing cardiomyocytes, engineered heart tissue and mouse hearts, respectively, by means of adenoviral and adeno-associated viral S100A1 cDNA delivery normalizes diastolic RyR2 function and protects against Ca(2+)- and ß-adrenergic receptor-triggered proarrhythmogenic SR Ca(2+) leakage in vitro and in vivo. S100A1 inhibits diastolic SR Ca(2+) leakage despite aberrant RyR2 phosphorylation via protein kinase A and calmodulin-dependent kinase II and stoichiometry with accessory modulators such as calmodulin, FKBP12.6 or sorcin. Our findings demonstrate that S100A1 is a regulator of diastolic RyR2 activity and beneficially modulates diastolic RyR2 dysfunction. S100A1 interaction with the RyR2 is sufficient to protect against basal and catecholamine-triggered arrhythmic SR Ca(2+) leak in HF, combining antiarrhythmic potency with chronic inotropic actions.


Assuntos
Insuficiência Cardíaca/genética , Canal de Liberação de Cálcio do Receptor de Rianodina/genética , Proteínas S100/metabolismo , Animais , Cálcio/metabolismo , Proteínas de Ligação ao Cálcio/metabolismo , Calmodulina/metabolismo , DNA Complementar/metabolismo , Eletrocardiografia , Técnicas de Transferência de Genes , Insuficiência Cardíaca/prevenção & controle , Masculino , Camundongos , Microscopia de Fluorescência , Miocárdio/metabolismo , Miócitos Cardíacos/citologia , Fosforilação , Ligação Proteica , Ratos , Ratos Sprague-Dawley , Canal de Liberação de Cálcio do Receptor de Rianodina/metabolismo , Retículo Sarcoplasmático/metabolismo , Proteínas de Ligação a Tacrolimo/metabolismo , Engenharia Tecidual/métodos
8.
Circ Res ; 113(6): 792-809, 2013 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-23989720

RESUMO

Gene therapy, aimed at the correction of key pathologies being out of reach for conventional drugs, bears the potential to alter the treatment of cardiovascular diseases radically and thereby of heart failure. Heart failure gene therapy refers to a therapeutic system of targeted drug delivery to the heart that uses formulations of DNA and RNA, whose products determine the therapeutic classification through their biological actions. Among resident cardiac cells, cardiomyocytes have been the therapeutic target of numerous attempts to regenerate systolic and diastolic performance, to reverse remodeling and restore electric stability and metabolism. Although the concept to intervene directly within the genetic and molecular foundation of cardiac cells is simple and elegant, the path to clinical reality has been arduous because of the challenge on delivery technologies and vectors, expression regulation, and complex mechanisms of action of therapeutic gene products. Nonetheless, since the first demonstration of in vivo gene transfer into myocardium, there have been a series of advancements that have driven the evolution of heart failure gene therapy from an experimental tool to the threshold of becoming a viable clinical option. The objective of this review is to discuss the current state of the art in the field and point out inevitable innovations on which the future evolution of heart failure gene therapy into an effective and safe clinical treatment relies.


Assuntos
Terapia Genética , Insuficiência Cardíaca/terapia , Adenilil Ciclases/genética , Animais , Técnicas de Transferência de Genes , Insuficiência Cardíaca/genética , Humanos , Receptores Adrenérgicos beta/genética , Proteínas S100/genética , ATPases Transportadoras de Cálcio do Retículo Sarcoplasmático/genética
9.
Circ Res ; 112(1): 66-78, 2013 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-23048072

RESUMO

RATIONALE: Mice lacking the EF-hand Ca2+ sensor S100A1 display endothelial dysfunction because of distorted Ca2+ -activated nitric oxide (NO) generation. OBJECTIVE: To determine the pathophysiological role of S100A1 in endothelial cell (EC) function in experimental ischemic revascularization. METHODS AND RESULTS: Patients with chronic critical limb ischemia showed almost complete loss of S100A1 expression in hypoxic tissue. Ensuing studies in S100A1 knockout (SKO) mice subjected to femoral artery resection unveiled insufficient perfusion recovery and high rates of autoamputation. Defective in vivo angiogenesis prompted cellular studies in SKO ECs and human ECs, with small interfering RNA-mediated S100A1 knockdown demonstrating impaired in vitro and in vivo proangiogenic properties (proliferation, migration, tube formation) and attenuated vascular endothelial growth factor (VEGF)-stimulated and hypoxia-stimulated endothelial NO synthase (eNOS) activity. Mechanistically, S100A1 deficiency compromised eNOS activity in ECs by interrupted stimulatory S100A1/eNOS interaction and protein kinase C hyperactivation that resulted in inhibitory eNOS phosphorylation and enhanced VEGF receptor-2 degradation with attenuated VEGF signaling. Ischemic SKO tissue recapitulated the same molecular abnormalities with insufficient in vivo NO generation. Unresolved ischemia entailed excessive VEGF accumulation in SKO mice with aggravated VEGF receptor-2 degradation and blunted in vivo signaling through the proangiogenic phosphoinositide-3-kinase/Akt/eNOS cascade. The NO supplementation strategies rescued defective angiogenesis and salvaged limbs in SKO mice after femoral artery resection. CONCLUSIONS: Our study shows for the first time downregulation of S100A1 expression in patients with critical limb ischemia and identifies S100A1 as critical for EC function in postnatal ischemic angiogenesis. These findings link its pathological plasticity in critical limb ischemia to impaired neovascularization, prompting further studies to probe the microvascular therapeutic potential of S100A1.


Assuntos
Células Endoteliais/enzimologia , Isquemia/enzimologia , Músculo Esquelético/irrigação sanguínea , Neovascularização Fisiológica , Óxido Nítrico Sintase Tipo III/metabolismo , Proteínas S100/deficiência , Idoso , Idoso de 80 Anos ou mais , Animais , Cálcio/metabolismo , Células Cultivadas , Modelos Animais de Doenças , Células Endoteliais/efeitos dos fármacos , Feminino , Membro Posterior , Células Endoteliais da Veia Umbilical Humana/enzimologia , Humanos , Isquemia/tratamento farmacológico , Isquemia/genética , Isquemia/fisiopatologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Pessoa de Meia-Idade , Músculo Esquelético/patologia , Neovascularização Fisiológica/efeitos dos fármacos , Óxido Nítrico/metabolismo , Doadores de Óxido Nítrico/farmacologia , Fosfatidilinositol 3-Quinase/metabolismo , Fosforilação , Proteína Quinase C/metabolismo , Proteínas Proto-Oncogênicas c-akt/metabolismo , Interferência de RNA , Fluxo Sanguíneo Regional , Proteínas S100/genética , Transdução de Sinais , Fatores de Tempo , Transfecção , Fator A de Crescimento do Endotélio Vascular/metabolismo , Receptor 2 de Fatores de Crescimento do Endotélio Vascular/metabolismo
10.
J Interv Cardiol ; 28(2): 190-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25728716

RESUMO

OBJECTIVES: We assessed efficacy and safety of the Gore(®) Septal Occluder (GSO) for patent foramen ovale (PFO) closure focusing on patients with challenging septal anatomies. BACKGROUND: In times of controversial discussion whether percutaneous PFO closure is superior to medical therapy for the prevention of recurrent embolic events after cryptogenic stroke, patient selection should mainly focus on individuals with an increased likelihood that the ischaemic event is related to the PFO. In this context, specific septal anatomies-such as the presence of an atrial septal aneurysm as well as long PFO tunnel anatomy-have been associated with a higher rate of cerebrovascular accidents. METHODS: The GSO was used for PFO closure in 41 patients presenting with either atrial septal aneurysm (ASA; 27/41; 65.9%) or long PFO tunnel (> 10 mm; 32/41; 78%). Seven of these patients even presented with a tunnel length ≥ 20 mm (7/41; 17.1%). Eighteen patients had both, long-tunnel anatomy and ASA (18/41; 43.9%). RESULTS: The GSO was successfully implanted in all cases. No procedural complications occurred and all patients were discharged the day after the procedure. Short-term follow-up, including TEE examination, in all patients was performed 37.6 ± 9.0 days after the procedure. Mid-term follow-up was performed after 192.7 ± 45.3 days. Later complications occurred in 7.3% (2 new onset atrial fibrillation, 1 device thrombus). Only 3 patients (7.3%) had more than trace residual shunts at 6-weeks follow-up. At 6-months follow-up, the complete closure rate was 95.1% (39/41). CONCLUSIONS: The Gore(®) Septal Occluder is an efficient device for patent foramen ovale closure in challenging anatomies, including long-tunnel PFOs and atrial septal aneurysms.


Assuntos
Cateterismo Cardíaco/instrumentação , Forame Oval Patente/cirurgia , Dispositivo para Oclusão Septal , Adulto , Desenho de Equipamento , Feminino , Seguimentos , Forame Oval Patente/complicações , Forame Oval Patente/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
11.
J Interv Cardiol ; 28(1): 109-16, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25689554

RESUMO

BACKGROUND: TAVR has become an established treatment for severe symptomatic aortic stenosis in patients with high surgical risk. The latest generation of the balloon-expandable Edwards Sapien device, the Sapien 3, together with its new transfemoral Commander delivery system has been designed to reduce paravalvular regurgitation and vascular access site complications. OBJECTIVES: To evaluate procedural results and short term outcome with the third generation Sapien 3 device. METHODS: We retrospectively evaluated 125 consecutive TAVR patients and analyzed the first 51 patients in whom we implanted the new Sapien 3 device via transfemoral access. RESULTS: In patients implanted with the Sapien 3 device significant residual paravalvular regurgitation after TAVR was virtually absent with the vast majority having none or trace postinterventional aortic regurgitation on angiography or echocardiography (92.2% and 80.4% respectively). None of the patients had more than mild paravalvular regurgitation. Major vascular access site complications or major bleeding according to the VARC II criteria were not observed in our cohort, minor vascular complications and minor bleeding occurred in 7.8% and 5.9% respectively. If vascular complications occurred, they were related to closure device failure. Thirty day outcome showed a 1.9% major stroke rate and 3.9% death rate. However, we observed a 25.5% permanent pacemaker rate in our Sapien 3 cohort. CONCLUSIONS: Implantation of the new third generation Sapien 3 device resulted in excellent procedural and short term outcome. Significant paravalvular regurgitation was virtually absent. However, the increased rate of postinterventional pacemaker implantations needs to be analyzed in a larger cohort of patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/cirurgia , Aortografia , Feminino , Humanos , Masculino , Marca-Passo Artificial/estatística & dados numéricos , Avaliação de Resultados da Assistência ao Paciente , Ajuste de Prótese , Estudos Retrospectivos
12.
J Interv Cardiol ; 27(2): 191-8, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24433399

RESUMO

BACKGROUND: Transcatheter aortic valve implantation has become an established treatment for severe aortic stenosis in patients with high surgical risk. Due to its specific design, the self-expanding 31 mm CoreValve prosthesis can be technically challenging. This is especially true for patients with large annuli above 27.5 mm for which the CoreValve 31 mm device is the only option. OBJECTIVES: To evaluate procedural results and short-term outcome with the 31 mm CoreValve device in patients with large annuli. METHODS: We retrospectively analyzed 54 patients in whom we implanted a 31 mm self-expanding CoreValve bioprosthesis and compared them to 50 consecutive patients implanted with the smaller 29 mm device within the same period of time. RESULTS: Patients with the 31 mm prosthesis had significantly higher rates of postinterventional pacemaker implantations (35% vs. 20%; P = 0.036) despite similar implantation depths (6.5 ± 4 vs. 7.5 ± 4; P = 0.34). However, the number of deep implantations (>8 mm) was significantly higher (P = 0.045). No significant difference could be observed with respect to cases with ≥Grade 2 postinterventional aortic regurgitation (8% vs. 12.9%; P = 0.5294). Major vascular complications (4% vs. 3.7%; P = ns), 30-day mortality (8% vs. 7.7%; P = ns), and major stroke (3.8% vs. 2%; P = ns) were not different between the 2 groups. CONCLUSION: Despite the technical challenges, procedural results with the 31 mm self-expanding CoreValve prosthesis in large anatomies were similar to those with the smaller sized 29 mm version of the device. However, postinterventional pacemaker rates were significantly higher in the 31 mm cohort despite comparable implantation depths, which might be the result of the specific design of the device.


Assuntos
Valva Aórtica/anatomia & histologia , Bioprótese , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Desenho de Prótese , Implantação de Prótese , Estudos Retrospectivos , Resultado do Tratamento
13.
J Interv Cardiol ; 25(2): 174-9, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22487134

RESUMO

AIMS OF THE STUDY: Transcatheter aortic valve implantation (TAVI) has become an established treatment for severe aortic stenosis in patients with unacceptable high-surgical risk. Recently, the new AccuTrak delivery system for improved deliverability of the CoreValve aortic bioprosthesis was launched. It has not yet been shown if the new delivery catheter leads to optimized positioning and improved procedural outcomes. METHODS AND RESULTS: We conducted a retrospective single-center analysis and evaluated 70 consecutive patients (35 with the original delivery catheter and 35 with the new AccuTrak catheter) for anatomic positioning and related outcome parameters like postinterventional aortic regurgitation (AR) and the need for permanent pacemaker insertion, after CoreValve implantation. The use of the AccuTrak delivery catheter resulted in significantly higher positioning of the CoreValve prosthesis in the left ventricular outflow tract (distance from annulus to lower edge of prosthesis 7.0 mm [5.5 to 9.4 mm] for the AccuTrak group vs. 8.8 mm [7.1 to 11.2 mm] for the original system; median [interquartile range]; P = 0.0068). Moreover, the optimized positioning resulted in reduced rates of significant (≥grade 2) AR assessed by postinterventional aortography and echocardiography (P = 0.044 and P = 0.0275, respectively). Despite improved positioning, no differences in the need for permanent pacemaker implantation were observed. CONCLUSIONS: Our retrospective analysis indicates improved positioning with reduced postinterventional AR with the new CoreValve AccuTrak delivery system. Whether this may also affect the need for permanent pacemaker insertion or long-term outcome after TAVI needs to be evaluated in larger studies.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica , Cateterismo Cardíaco/instrumentação , Catéteres , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Bioprótese , Angiografia Coronária , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Modelos Logísticos , Masculino , Marca-Passo Artificial , Estudos Retrospectivos
15.
J Clin Med ; 10(14)2021 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-34300238

RESUMO

BACKGROUND: Transcatheter aortic valve implantation is a feasible alternative to conventional aortic valve replacement with expanding indication extending to low-risk patients. Sutureless and rapid-deployment aortic valves were developed to decrease procedural risks in conventional treatment. This paired-match analysis aims to compare patients undergoing surgical transcatheter aortic valve implantation to sutureless and rapid-deployment aortic valve implantation. METHODS: Retrospective database analysis between 2010 and 2016 revealed 214 patients undergoing transcatheter aortic valve implantation procedures through surgical access (predominantly transapical) and 62 sutureless and rapid-deployment aortic valve procedures including 26 patients in need of concomitant coronary artery bypass surgery. After matching, 52 pairs of patients were included and analyzed. RESULTS: In-hospital death (5.8% vs. 3.8%; p = 0.308) was comparable between transcatheter aortic valve implantation (mean age 77 ± 4.3 years) and sutureless and rapid-deployment aortic valve implantation groups (mean age 75 ± 4.0 years), including 32 females in each group. The logistic EuroSCORE was similar (19 ± 12 vs. 17 ± 10; p = 0.257). Postoperative renal failure (p = 0.087) and cerebrovascular accidents (p = 0.315) were without significant difference. The incidence of complete heart block requiring permanent pacemaker treatment was relatively low for both groups (1.9% vs. 7.7%; p = 0.169) for TAVI and sutureless and rapid-deployment valves respectively. Intraoperative use of blood transfusion was higher in the sutureless and rapid-deployment aortic valve implantation group (0.72 U vs. 1.46 U, p = 0.014). Estimated survival calculated no significant difference between both groups after 6 months (transcatheter aortic valve implantation: 74 ± 8% vs. sutureless and rapid-deployment aortic valve implantation: 92 ± 5%; log rank p = 0.097). CONCLUSION: Since sutureless and rapid-deployment aortic valve implantation is as safe and effective as transapical transcatheter aortic valve implantation, combining the advantage of standard diseased-valve removal with shorter procedural times, sutureless and rapid-deployment aortic valve replacement may be considered as an alternative for patients with elevated operative risk considered to be in the "gray zone" between transcatheter aortic valve implantation and conventional surgery, especially if concomitant myocardial revascularization is required.

16.
ESC Heart Fail ; 8(6): 4617-4625, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34498422

RESUMO

AIM: Percutaneous mitral valve repair (PMVR) via MitraClip implantation is a therapeutic option for severe mitral regurgitation (MR) in advanced stages of heart failure (HF). However, progressive left ventricular dilation in these patients may lead to recurrent MR after PMVR and consequent re-do MitraClip implantation. Here, we describe the characteristics and outcomes of this clinical scenario. METHODS AND RESULTS: Patients with systolic HF and functional MR undergoing a re-do MitraClip procedure were retrospectively analysed. Inclusion criteria were age ≥18 years, technical, device and procedural success at first MitraClip procedure, functional MR and systolic HF with an ejection fraction (EF) of <45%. Seventeen out of 684 patients undergoing PMVR with the MitraClip device at our institution between September 2009 and July 2019 were included. All patients displayed advanced HF with an EF of 20% (±9.9) and highly elevated N-terminal pro-brain natriuretic peptide. Technical success of the re-do MitraClip procedure was 100%, whereas procedural and device success were only achieved in 11 patients (65%). Unsuccessful re-do procedures were related to lower EF and implantation of more than one clip at initial procedure. However, despite reduction in MR grade and no occurrence of significant mitral stenosis after the procedure, the mortality during 12 months follow-up remained high (8 of 17; 47%). CONCLUSIONS: In a cohort of patients with advanced HF undergoing PMVR, re-do MitraClip procedure was feasible, but procedural success was unsatisfactory and morbidity and mortality remained high, possibly reflecting the advanced stage of HF in these patients.


Assuntos
Insuficiência Cardíaca Sistólica , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Adolescente , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
17.
Clin Res Cardiol ; 110(1): 12-20, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32296971

RESUMO

OBJECTIVES: Chronic kidney disease (CKD) is associated with an increased complication rate after cardiac interventions. Although CKD has a high prevalence among atrial fibrillation patients, the impact of CKD on periprocedural complications and the outcome after an interventional left atrial appendage closure (LAAC) is unclear. The present study, therefore, aimed to investigate whether CKD influences the procedure's effectiveness and safety. METHODS: LAARGE is a prospective, non-randomised registry. LAAC was conducted with different standard commercial devices, and the follow-up period was one year. CKD was defined by an eGFR < 60 mL/min/1.73 m2, and subgroups were further analysed (i.e. eGFR < 15, 15-29, and 30-59 mL/min/1.73 m2, respectively). RESULTS: Two hundred ninety-nine of 623 patients (48.0%) revealed a CKD. The prevalence of cardiovascular comorbidity, CHA2DS2-VASc score (4.9 vs. 4.2), and HAS-BLED score (4.3 vs. 3.5) was significantly higher in CKD patients (each p < 0.001). Implantation success was similarly high across all GFR groups (97.9%). Periprocedural MACCE (0.7 vs. 0.3%), and other major complications (4.7 vs. 3.7%) were comparably infrequent. Survival free of stroke was significantly lower among CKD patients within 1 year (82.0 vs. 93.0%; p < 0.001; consistent after adjustment for confounding factors), without significant accentuation in advanced CKD (i.e. eGFR < 30 mL/min/1.73 m2; p > 0.05 vs. eGFR 30-59 mL/min/1.73 m2). Non-fatal strokes were absolutely infrequent during follow-up (0 vs. 1.1%). Severe non-fatal bleedings were observed only among CKD patients (1.4 vs. 0%; p = 0.021). CONCLUSIONS: Despite an increased cardiovascular risk profile of CKD patients, device implantation was safe, and LAAC was associated with effective stroke prevention across all CKD stages.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Sistema de Registros , Insuficiência Renal Crônica/complicações , Dispositivo para Oclusão Septal , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Feminino , Seguimentos , Alemanha , Taxa de Filtração Glomerular/fisiologia , Humanos , Masculino , Estudos Prospectivos , Insuficiência Renal Crônica/fisiopatologia , Resultado do Tratamento
18.
Basic Res Cardiol ; 105(6): 805-20, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20703492

RESUMO

Diabetes mellitus (DM) is a major independent risk factor for cardiovascular disease, but also leads to cardiomyopathy. However, the etiology of the cardiac disease is unknown. Therefore, the aim of this study was to identify molecular mechanisms underlying diabetic heart disease. High glucose treatment of isolated cardiac fibroblasts, macrophages and cardiomyocytes led to a sustained induction of HMGB1 on the RNA and protein level followed by increased NF-κB binding activity with consecutively sustained TNF-α and IL-6 expression. Short interference (si) RNA knock-down for HMGB1 and RAGE in vitro confirmed the importance of this axis in diabetes-driven chronic inflammation. In a murine model of post-myocardial infarction remodeling in type 1 diabetes, cardiac HMGB1 expression was significantly elevated both on RNA and protein level paralleled by increased expression of pro-inflammatory cytokines up to 10 weeks. HMGB1-specific blockage via box A treatment significantly reduced post-myocardial infarction remodeling and markers of tissue damage in vivo. The protective effects of box A indicated an involvement of the mitogen-activated protein-kinases jun N-terminal kinase and extracellular signal-regulated kinase 1/2, as well as the transcription factor nuclear factor-kappaB. Interestingly, remodeling and tissue damage were not affected by administration of box A in RAGE(-/-) mice. In conclusion, HMGB1 plays a major role in DM and post-I/R remodeling by binding to RAGE, resulting in activation of sustained pro-inflammatory pathways and enhanced myocardial injury. Therefore, blockage of HMGB1 might represent a therapeutic strategy to reduce post-ischemic remodeling in DM.


Assuntos
Diabetes Mellitus Experimental/metabolismo , Diabetes Mellitus Tipo 1/metabolismo , Proteína HMGB1/metabolismo , Insuficiência Cardíaca/etiologia , Infarto do Miocárdio/metabolismo , Traumatismo por Reperfusão Miocárdica/metabolismo , Miócitos Cardíacos/metabolismo , Animais , Células Cultivadas , Diabetes Mellitus Experimental/complicações , Diabetes Mellitus Experimental/fisiopatologia , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/fisiopatologia , MAP Quinases Reguladas por Sinal Extracelular/metabolismo , Fibroblastos/metabolismo , Glucose/metabolismo , Proteína HMGB1/administração & dosagem , Proteína HMGB1/genética , Insuficiência Cardíaca/metabolismo , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/prevenção & controle , Mediadores da Inflamação/metabolismo , Injeções Intraperitoneais , Proteínas Quinases JNK Ativadas por Mitógeno/metabolismo , Macrófagos/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Infarto do Miocárdio/complicações , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/prevenção & controle , Traumatismo por Reperfusão Miocárdica/complicações , Traumatismo por Reperfusão Miocárdica/fisiopatologia , Traumatismo por Reperfusão Miocárdica/prevenção & controle , NF-kappa B/metabolismo , Interferência de RNA , Ratos , Receptor para Produtos Finais de Glicação Avançada , Receptores Imunológicos/deficiência , Receptores Imunológicos/genética , Proteínas Recombinantes/administração & dosagem , Fatores de Tempo , Transfecção , Remodelação Ventricular
19.
BMC Cancer ; 10: 105, 2010 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-20307299

RESUMO

BACKGROUND: Cancer, heart failure and stroke are among the most common causes of death worldwide. Investigation of the prognostic impact of each disease is important, especially for a better understanding of competing risks. Aim of this study is to provide an overview of long term survival of cancer, heart failure and stroke patients based on the results of large population- and hospital-based studies. METHODS: Records for our study were identified by searches of Medline via Pubmed. We focused on observed and relative age- and sex-adjusted 5-year survival rates for cancer in general and for the four most common malignancies in developed countries, i.e. lung, breast, prostate and colorectal cancer, as well as for heart failure and stroke. RESULTS: Twenty studies were identified and included for analysis. Five-year observed survival was about 43% for all cancer entities, 40-68% for stroke and 26-52% for heart failure. Five-year age and sex adjusted relative survival was 50-57% for all cancer entities, about 50% for stroke and about 62% for heart failure. In regard to the four most common malignancies in developed countries 5-year relative survival was 12-18% for lung cancer, 73-89% for breast cancer, 50-99% for prostate cancer and about 43-63% for colorectal cancer. Trend analysis revealed a survival improvement over the last decades. CONCLUSIONS: The results indicate that long term survival and prognosis of cancer is not necessarily worse than that of heart failure and stroke. However, a comparison of the prognostic impact of the different diseases is limited, corroborating the necessity for further systematic investigation of competing risks.


Assuntos
Insuficiência Cardíaca/terapia , Neoplasias/mortalidade , Neoplasias/patologia , Acidente Vascular Cerebral/terapia , Idoso , Causas de Morte , Feminino , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Risco , Acidente Vascular Cerebral/mortalidade , Taxa de Sobrevida , Resultado do Tratamento
20.
Circ Res ; 102(7): 786-94, 2008 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-18292599

RESUMO

S100A1, a Ca(2+)-binding protein of the EF-hand type, is known to modulate sarcoplasmic reticulum Ca(2+) handling in skeletal muscle and cardiomyocytes. Recently, S100A1 has been shown to be expressed in endothelial cells (ECs). Because intracellular Ca(2+) ([Ca(2+)](i)) transients can be involved in important EC functions and endothelial NO synthase activity, we sought to investigate the impact of endothelial S100A1 on the regulation of endothelial and vascular function. Thoracic aortas from S100A1 knockout mice (SKO) showed significantly reduced relaxation in response to acetylcholine compared with wild-type vessels, whereas direct vessel relaxation using sodium nitroprusside was unaltered. Endothelial dysfunction attributable to the lack of S100A1 expression could also be demonstrated in vivo and translated into hypertension of SKO. Mechanistically, both basal and acetylcholine-induced endothelial NO release of SKO aortas was significantly reduced compared with wild type. Impaired endothelial NO production in SKO could be attributed, at least in part, to diminished agonist-induced [Ca(2+)](i) transients in ECs. Consistently, silencing endothelial S100A1 expression in wild type also reduced [Ca(2+)](i) and NO generation. Moreover, S100A1 overexpression in ECs further increased NO generation that was blocked by the inositol-1,4,5-triphosphate receptor blocker 2-aminoethoxydiphenylborate. Finally, cardiac endothelial S100A1 expression was shown to be downregulated in heart failure in vivo. Collectively, endothelial S100A1 critically modulates vascular function because lack of S100A1 expression leads to decreased [Ca(2+)](i) and endothelial NO release, which contributes, at least partially, to impaired endothelium-dependent vascular relaxation and hypertension in SKO mice. Targeting endothelial S100A1 expression may, therefore, be a novel therapeutic means to improve endothelial function in vascular disease or heart failure.


Assuntos
Endotélio Vascular/metabolismo , Óxido Nítrico/metabolismo , Proteínas S100/metabolismo , Vasoconstrição/fisiologia , Vasodilatação/fisiologia , Acetilcolina/farmacologia , Animais , Aorta Torácica/metabolismo , Aorta Torácica/patologia , Aorta Torácica/fisiopatologia , Cálcio/metabolismo , Modelos Animais de Doenças , Endotélio Vascular/patologia , Endotélio Vascular/fisiopatologia , Feminino , Insuficiência Cardíaca/metabolismo , Insuficiência Cardíaca/patologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Hipertensão/metabolismo , Hipertensão/patologia , Hipertensão/fisiopatologia , Receptores de Inositol 1,4,5-Trifosfato/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Nitroprussiato/farmacologia , Ratos , Ratos Wistar , ATPases Transportadoras de Cálcio do Retículo Sarcoplasmático/metabolismo , Vasoconstrição/efeitos dos fármacos , Vasodilatação/efeitos dos fármacos , Vasodilatadores/farmacologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa