Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Bioinformatics ; 18(1): 88, 2017 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-28158972

RESUMO

BACKGROUND: Tracing stable isotopes, such as 13C using various mass spectrometry (MS) methods provides a valuable information necessary for the study of biochemical processes in cells. However, extracting such information requires special care, such as a correction for naturally occurring isotopes, or overlapping mass spectra of various components of the cell culture medium. Developing a method for a correction of overlapping peaks is the primary objective of this study. RESULTS: Our computer program-MIDcor (free at https://github.com/seliv55/mid_correct) written in the R programming language, corrects the raw MS spectra both for the naturally occurring isotopes and for the overlapping of peaks corresponding to various substances. To this end, the mass spectra of unlabeled metabolites measured in two media are necessary: in a minimal medium containing only derivatized metabolites and chemicals for derivatization, and in a complete cell incubated medium. The MIDcor program calculates the difference (D) between the theoretical and experimentally measured spectra of metabolites containing only the naturally occurring isotopes. The result of comparison of D in the two media determines a way of deciphering the true spectra. (1) If D in the complete medium is greater than that in the minimal medium in at least one peak, then unchanged D is subtracted from the raw spectra of the labeled metabolite. (2) If D does not depend on the medium, then the spectrum probably overlaps with a derivatized fragment of the same metabolite, and D is modified proportionally to the metabolite labeling. The program automatically reaches a decision regarding the way of correction. For some metabolites/fragments in the case (2) D was found to decrease when the tested substance was 13C labeled, and this isotopic effect also can be corrected automatically, if the user provides a measured spectrum of the substance in which the 13C labeling is known a priori. CONCLUSION: Using the developed program improves the reliability of stable isotope tracer data analysis.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas , Metaboloma , Interface Usuário-Computador , Isótopos de Carbono/química , Linhagem Celular , Meios de Cultura/análise , Humanos , Internet , Marcação por Isótopo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa