Artigo em Inglês | MEDLINE | ID: mdl-28572719

RESUMO

Model-based image reconstruction (MBIR) techniques have the potential to generate high quality images from noisy measurements and a small number of projections which can reduce the x-ray dose in patients. These MBIR techniques rely on projection and backprojection to refine an image estimate. One of the widely used projectors for these modern MBIR based technique is called branchless distance driven (DD) projection and backprojection. While this method produces superior quality images, the computational cost of iterative updates keeps it from being ubiquitous in clinical applications. In this paper, we provide several new parallelization ideas for concurrent execution of the DD projectors in multi-GPU systems using CUDA programming tools. We have introduced some novel schemes for dividing the projection data and image voxels over multiple GPUs to avoid runtime overhead and inter-device synchronization issues. We have also reduced the complexity of overlap calculation of the algorithm by eliminating the common projection plane and directly projecting the detector boundaries onto image voxel boundaries. To reduce the time required for calculating the overlap between the detector edges and image voxel boundaries, we have proposed a pre-accumulation technique to accumulate image intensities in perpendicular 2D image slabs (from a 3D image) before projection and after backprojection to ensure our DD kernels run faster in parallel GPU threads. For the implementation of our iterative MBIR technique we use a parallel multi-GPU version of the alternating minimization (AM) algorithm with penalized likelihood update. The time performance using our proposed reconstruction method with Siemens Sensation 16 patient scan data shows an average of 24 times speedup using a single TITAN X GPU and 74 times speedup using 3 TITAN X GPUs in parallel for combined projection and backprojection.

2.
J Comput Assist Tomogr ; 40(4): 589-95, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27096403

RESUMO

OBJECTIVE: The aim of this study was to compare the performance of 2- (2D) and 3-dimensional (3D) quantitative computed tomography (CT) methods for classifying lung nodules as lung cancer, metastases, or benign. METHODS: Using semiautomated software and computerized analysis, we analyzed more than 50 quantitative CT features of 96 solid nodules in 94 patients, in 2D from a single slice and in 3D from the entire nodule volume. Multivariable logistic regression was used to classify nodule types. Model performance was assessed by the area under the receiver operating characteristic curve (AUC) using leave-one-out cross-validation. RESULTS: The AUC for distinguishing 53 primary lung cancers from 18 benign nodules and 25 metastases ranged from 0.79 to 0.83 and was not significantly different for 2D and 3D analyses (P = 0.29-0.78). Models distinguishing metastases from benign nodules were statistically significant only by 3D analysis (AUC = 0.84). CONCLUSIONS: Three-dimensional CT methods did not improve discrimination of lung cancer, but may help distinguish benign nodules from metastases.


Assuntos
Imageamento Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga Tumoral
3.
J Opt Soc Am A Opt Image Sci Vis ; 31(7): 1369-94, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-25121423

RESUMO

We investigate new sampling strategies for projection tomography, enabling one to employ fewer measurements than expected from classical sampling theory without significant loss of information. Inspired by compressed sensing, our approach is based on the understanding that many real objects are compressible in some known representation, implying that the number of degrees of freedom defining an object is often much smaller than the number of pixels/voxels. We propose a new approach based on quasi-random detector subsampling, whereas previous approaches only addressed subsampling with respect to source location (view angle). The performance of different sampling strategies is considered using object-independent figures of merit, and also based on reconstructions for specific objects, with synthetic and real data. The proposed approach can be implemented using a structured illumination of the interrogated object or the detector array by placing a coded aperture/mask at the source or detector side, respectively. Advantages of the proposed approach include (i) for structured illumination of the detector array, it leads to fewer detector pixels and allows one to integrate detectors for scattered radiation in the unused space; (ii) for structured illumination of the object, it leads to a reduced radiation dose for patients in medical scans; (iii) in the latter case, the blocking of rays reduces scattered radiation while keeping the same energy in the transmitted rays, resulting in a higher signal-to-noise ratio than that achieved by lowering exposure times or the energy of the source; (iv) compared to view-angle subsampling, it allows one to use fewer measurements for the same image quality, or leads to better image quality for the same number of measurements. The proposed approach can also be combined with view-angle subsampling.

4.
Phys Med Biol ; 68(24)2023 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-37802071

RESUMO

Objective.Over the past several decades, dual-energy CT (DECT) imaging has seen significant advancements due to its ability to distinguish between materials. DECT statistical iterative reconstruction (SIR) has exhibited potential for noise reduction and enhanced accuracy. However, its slow convergence and substantial computational demands render the elapsed time for 3D DECT SIR often clinically unacceptable. The objective of this study is to accelerate 3D DECT SIR while maintaining subpercentage or near-subpercentage accuracy.Approach.We incorporate DECT SIR into a deep-learning model-based unrolling network for 3D DECT reconstruction (MB-DECTNet), which can be trained end-to-end. This deep learning-based approach is designed to learn shortcuts between initial conditions and the stationary points of iterative algorithms while preserving the unbiased estimation property of model-based algorithms. MB-DECTNet comprises multiple stacked update blocks, each containing a data consistency layer (DC) and a spatial mixer layer, with the DC layer functioning as a one-step update from any traditional iterative algorithm.Main results.The quantitative results indicate that our proposed MB-DECTNet surpasses both the traditional image-domain technique (MB-DECTNet reduces average bias by a factor of 10) and a pure deep learning method (MB-DECTNet reduces average bias by a factor of 8.8), offering the potential for accurate attenuation coefficient estimation, akin to traditional statistical algorithms, but with considerably reduced computational costs. This approach achieves 0.13% bias and 1.92% mean absolute error and reconstructs a full image of a head in less than 12 min. Additionally, we show that the MB-DECTNet output can serve as an initializer for DECT SIR, leading to further improvements in results.Significance.This study presents a model-based deep unrolling network for accurate 3D DECT reconstruction, achieving subpercentage error in estimating virtual monoenergetic images for a full head at 60 and 150 keV in 30 min, representing a 40-fold speedup compared to traditional approaches. These findings have significant implications for accelerating DECT SIR and making it more clinically feasible.


Assuntos
Cabeça , Processamento de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Algoritmos
5.
Phys Med Biol ; 68(14)2023 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-37327796

RESUMO

Objective.Dual-energy computed tomography (DECT) has been widely used to reconstruct numerous types of images due its ability to better discriminate tissue properties. Sequential scanning is a popular dual-energy data acquisition method as it requires no specialized hardware. However, patient motion between two sequential scans may lead to severe motion artifacts in DECT statistical iterative reconstructions (SIR) images. The objective is to reduce the motion artifacts in such reconstructions.Approach.We propose a motion-compensation scheme that incorporates a deformation vector field into any DECT SIR. The deformation vector field is estimated via the multi-modality symmetric deformable registration method. The precalculated registration mapping and its inverse or adjoint are then embedded into each iteration of the iterative DECT algorithm.Main results.Results from a simulated and clinical case show that the proposed framework is capable of reducing motion artifacts in DECT SIRs. Percentage mean square errors in regions of interest in the simulated and clinical cases were reduced from 4.6% to 0.5% and 6.8% to 0.8%, respectively. A perturbation analysis was then performed to determine errors in approximating the continuous deformation by using the deformation field and interpolation. Our findings show that errors in our method are mostly propagated through the target image and amplified by the inverse matrix of the combination of the Fisher information and Hessian of the penalty term.Significance.We have proposed a novel motion-compensation scheme to incorporate a 3D registration method into the joint statistical iterative DECT algorithm in order to reduce motion artifacts caused by inter-scan motion, and successfully demonstrate that interscan motion corrections can be integrated into the DECT SIR process, enabling accurate imaging of radiological quantities on conventional SECT scanners, without significant loss of either computational efficiency or accuracy.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Movimento (Física) , Imagens de Fantasmas , Artefatos
6.
Med Phys ; 49(3): 1599-1618, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35029302

RESUMO

PURPOSE: To assess the potential of a joint dual-energy computerized tomography (CT) reconstruction process (statistical image reconstruction method built on a basis vector model (JSIR-BVM)) implemented on a 16-slice commercial CT scanner to measure high spatial resolution stopping-power ratio (SPR) maps with uncertainties of less than 1%. METHODS: JSIR-BVM was used to reconstruct images of effective electron density and mean excitation energy from dual-energy CT (DECT) sinograms for 10 high-purity samples of known density and atomic composition inserted into head and body phantoms. The measured DECT data consisted of 90 and 140 kVp axial sinograms serially acquired on a Philips Brilliance Big Bore CT scanner without beam-hardening corrections. The corresponding SPRs were subsequently measured directly via ion chamber measurements on a MEVION S250 superconducting synchrocyclotron and evaluated theoretically from the known sample compositions and densities. Deviations of JSIR-BVM SPR values from their theoretically calculated and directly measured ground-truth values were evaluated for our JSIR-BVM method and our implementation of the Hünemohr-Saito (H-S) DECT image-domain decomposition technique for SPR imaging. A thorough uncertainty analysis was then performed for five different scenarios (comparison of JSIR-BVM stopping-power ratio/stopping power (SPR/SP) to International Commission on Radiation Measurements and Units benchmarks; comparison of JSIR-BVM SPR to measured benchmarks; and uncertainties in JSIR-BVM SPR/SP maps for patients of unknown composition) per the Joint Committee for Guides in Metrology and the Guide to Expression of Uncertainty in Measurement, including the impact of uncertainties in measured photon spectra, sample composition and density, photon cross section and I-value models, and random measurement uncertainty. Estimated SPR uncertainty for three main tissue groups in patients of unknown composition and the weighted proportion of each tissue type for three proton treatment sites were then used to derive a composite range uncertainty for our method. RESULTS: Mean JSIR-BVM SPR estimates deviated by less than 1% from their theoretical and directly measured ground-truth values for most inserts and phantom geometries except for high-density Delrin and Teflon samples with SPR error relative to proton measurements of 1.1% and -1.0% (head phantom) and 1.1% and -1.1% (body phantom). The overall root-mean-square (RMS) deviations over all samples were 0.39% and 0.52% (head phantom) and 0.43% and 0.57% (body phantom) relative to theoretical and directly measured ground-truth SPRs, respectively. The corresponding RMS (maximum) errors for the image-domain decomposition method were 2.68% and 2.73% (4.68% and 4.99%) for the head phantom and 0.71% and 0.87% (1.37% and 1.66%) for the body phantom. Compared to H-S SPR maps, JSIR-BVM yielded 30% sharper and twofold sharper images for soft tissues and bone-like surrogates, respectively, while reducing noise by factors of 6 and 3, respectively. The uncertainty (coverage factor k = 1) of the DECT-to-benchmark values comparison ranged from 0.5% to 1.5% and is dominated by scanning-beam photon-spectra uncertainties. An analysis of the SPR uncertainty for patients of unknown composition showed a JSIR-BVM uncertainty of 0.65%, 1.21%, and 0.77% for soft-, lung-, and bony-tissue groups which led to a composite range uncertainty of 0.6-0.9%. CONCLUSIONS: Observed JSIR-BVM SPR estimation errors were all less than 50% of the estimated k = 1 total uncertainty of our benchmarking experiment, demonstrating that JSIR-BVM high spatial resolution, low-noise SPR mapping is feasible and is robust to variations in the geometry of the scanned object. In contrast, the much larger H-S SPR estimation errors are dominated by imaging noise and residual beam-hardening artifacts. While the uncertainties characteristic of our current JSIR-BVM implementation can be as large as 1.5%, achieving < 1% total uncertainty is feasible by improving the accuracy of scanner-specific scatter-profile and photon-spectrum estimates. With its robustness to beam-hardening artifact, image noise, and variations in phantom size and geometry, JSIR-BVM has the potential to achieve high spatial-resolution SPR mapping with subpercentage accuracy and estimated uncertainty in the clinical setting.


Assuntos
Prótons , Tomografia Computadorizada por Raios X , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Incerteza
7.
Med Phys ; 38(3): 1444-58, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21520856

RESUMO

PURPOSE: In comparison with conventional filtered backprojection (FBP) algorithms for x-ray computed tomography (CT) image reconstruction, statistical algorithms directly incorporate the random nature of the data and do not assume CT data are linear, noiseless functions of the attenuation line integral. Thus, it has been hypothesized that statistical image reconstruction may support a more favorable tradeoff than FBP between image noise and spatial resolution in dose-limited applications. The purpose of this study is to evaluate the noise-resolution tradeoff for the alternating minimization (AM) algorithm regularized using a nonquadratic penalty function. METHODS: Idealized monoenergetic CT projection data with Poisson noise were simulated for two phantoms with inserts of varying contrast (7%-238%) and distance from the field-of-view (FOV) center (2-6.5 cm). Images were reconstructed for the simulated projection data by the FBP algorithm and two penalty function parameter values of the penalized AM algorithm. Each algorithm was run with a range of smoothing strengths to allow quantification of the noise-resolution tradeoff curve. Image noise is quantified as the standard deviation in the water background around each contrast insert. Modulation transfer functions (MTFs) were calculated from six-parameter model fits to oversampled edge-spread functions defined by the circular contrast-insert edges as a metric of local resolution. The integral of the MTF up to 0.5 1p/mm was adopted as a single-parameter measure of local spatial resolution. RESULTS: The penalized AM algorithm noise-resolution tradeoff curve was always more favorable than that of the FBP algorithm. While resolution and noise are found to vary as a function of distance from the FOV center differently for the two algorithms, the ratio of noises when matching the resolution metric is relatively uniform over the image. The ratio of AM-to-FBP image variances, a predictor of dose-reduction potential, was strongly dependent on the shape of the AM's nonquadratic penalty function and was also strongly influenced by the contrast of the insert for which resolution is quantified. Dose-reduction potential, reported here as the fraction (%) of FBP dose necessary for AM to reconstruct an image with comparable noise and resolution, for one penalty parameter value of the AM algorithm was found to vary from 70% to 50% for low-contrast and high-contrast structures, respectively, and from 70% to 10% for the second AM penalty parameter value. However, the second penalty, AM-700, was found to suffer from poor low-contrast resolution when matching the high-contrast resolution metric with FBP. CONCLUSIONS: The results of this simulation study imply that penalized AM has the potential to reconstruct images with similar noise and resolution using a fraction (10%-70%) of the FBP dose. However, this dose-reduction potential depends strongly on the AM penalty parameter and the contrast magnitude of the structures of interest. In addition, the authors' results imply that the advantage of AM can be maximized by optimizing the nonquadratic penalty function to the specific imaging task of interest. Future work will extend the methods used here to quantify noise and resolution in images reconstructed from real CT data.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Distribuição Normal , Imagens de Fantasmas , Espalhamento de Radiação
8.
Artigo em Inglês | MEDLINE | ID: mdl-32025078

RESUMO

Photon counting CT (PCCT) is an x-ray imaging technique that has undergone great development in the past decade. PCCT has the potential to improve dose efficiency and low-dose performance. In this paper, we propose a statistics-based iterative algorithm to perform a direct reconstruction of material-decomposed images. Compared with the conventional sinogram-based decomposition method which has degraded performance in low-dose scenarios, the multi-energy alternating minimization algorithm for photon counting CT (MEAM-PCCT) can generate accurate material-decomposed image with much smaller biases.

9.
Med Phys ; 46(1): 273-285, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30421790

RESUMO

PURPOSE: To experimentally commission a dual-energy CT (DECT) joint statistical image reconstruction (JSIR) method, which is built on a linear basis vector model (BVM) of material characterization, for proton stopping power ratio (SPR) estimation. METHODS: The JSIR-BVM method builds on the relationship between the energy-dependent photon attenuation coefficients and the proton stopping power via a pair of BVM component weights. The two BVM component images are simultaneously reconstructed from the acquired DECT sinograms and then used to predict the electron density and mean excitation energy (I-value), which are required by the Bethe equation for SPR computation. A post-reconstruction image-based DECT method, which utilizes the two separate CT images reconstructed via the scanner's software, was implemented for comparison. The DECT measurement data were acquired on a Philips Brilliance scanner at 90 and 140 kVp for two phantoms of different sizes. Each phantom contains 12 different soft and bony tissue surrogates with known compositions. The SPR estimation results were compared to the reference values computed from the known compositions. The difference of the computed water equivalent path lengths (WEPL) across the phantoms between the two methods was also compared. RESULTS: The overall root-mean-square (RMS) of SPR estimation error of the JSIR-BVM method are 0.33% and 0.37% for the head- and body-sized phantoms, respectively, and all SPR estimates of the test samples are within 0.7% of the reference ground truth. The image-based method achieves overall RMS errors of 2.35% and 2.50% for the head- and body-sized phantoms, respectively. The JSIR-BVM method also reduces the pixel-wise random variation by 4-fold to 6-fold within homogeneous regions compared to the image-based method. The average differences between the JSIR-BVM method and the image-based method are 0.54% and 1.02% for the head- and body-sized phantoms, respectively. CONCLUSION: By taking advantage of an accurate polychromatic CT data model and a model-based DECT statistical reconstruction algorithm, the JSIR-BVM method accounts for both systematic bias and random noise in the acquired DECT measurement data. Therefore, the JSIR-BVM method achieves good accuracy and precision on proton SPR estimation for various tissue surrogates and object sizes. In contrast, the experimentally achievable accuracy of the image-based method may be limited by the uncertainties in the image formation process. The result suggests that the JSIR-BVM method has the potential for more accurate SPR prediction compared to post-reconstruction image-based methods in clinical settings.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Prótons , Tomografia Computadorizada por Raios X , Imagens de Fantasmas
10.
Med Phys ; 45(5): 2129-2142, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29570809

RESUMO

PURPOSE: The purpose of this study was to assess the performance of a novel dual-energy CT (DECT) approach for proton stopping power ratio (SPR) mapping that integrates image reconstruction and material characterization using a joint statistical image reconstruction (JSIR) method based on a linear basis vector model (BVM). A systematic comparison between the JSIR-BVM method and previously described DECT image- and sinogram-domain decomposition approaches is also carried out on synthetic data. METHODS: The JSIR-BVM method was implemented to estimate the electron densities and mean excitation energies (I-values) required by the Bethe equation for SPR mapping. In addition, image- and sinogram-domain DECT methods based on three available SPR models including BVM were implemented for comparison. The intrinsic SPR modeling accuracy of the three models was first validated. Synthetic DECT transmission sinograms of two 330 mm diameter phantoms each containing 17 soft and bony tissues (for a total of 34) of known composition were then generated with spectra of 90 and 140 kVp. The estimation accuracy of the reconstructed SPR images were evaluated for the seven investigated methods. The impact of phantom size and insert location on SPR estimation accuracy was also investigated. RESULTS: All three selected DECT-SPR models predict the SPR of all tissue types with less than 0.2% RMS errors under idealized conditions with no reconstruction uncertainties. When applied to synthetic sinograms, the JSIR-BVM method achieves the best performance with mean and RMS-average errors of less than 0.05% and 0.3%, respectively, for all noise levels, while the image- and sinogram-domain decomposition methods show increasing mean and RMS-average errors with increasing noise level. The JSIR-BVM method also reduces statistical SPR variation by sixfold compared to other methods. A 25% phantom diameter change causes up to 4% SPR differences for the image-domain decomposition approach, while the JSIR-BVM method and sinogram-domain decomposition methods are insensitive to size change. CONCLUSION: Among all the investigated methods, the JSIR-BVM method achieves the best performance for SPR estimation in our simulation phantom study. This novel method is robust with respect to sinogram noise and residual beam-hardening effects, yielding SPR estimation errors comparable to intrinsic BVM modeling error. In contrast, the achievable SPR estimation accuracy of the image- and sinogram-domain decomposition methods is dominated by the CT image intensity uncertainties introduced by the reconstruction and decomposition processes.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Prótons , Estatística como Assunto , Tomografia Computadorizada por Raios X , Algoritmos , Incerteza
11.
Sci Rep ; 8(1): 9286, 2018 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-29915334

RESUMO

Computed tomography (CT) examinations are commonly used to predict lung nodule malignancy in patients, which are shown to improve noninvasive early diagnosis of lung cancer. It remains challenging for computational approaches to achieve performance comparable to experienced radiologists. Here we present NoduleX, a systematic approach to predict lung nodule malignancy from CT data, based on deep learning convolutional neural networks (CNN). For training and validation, we analyze >1000 lung nodules in images from the LIDC/IDRI cohort. All nodules were identified and classified by four experienced thoracic radiologists who participated in the LIDC project. NoduleX achieves high accuracy for nodule malignancy classification, with an AUC of ~0.99. This is commensurate with the analysis of the dataset by experienced radiologists. Our approach, NoduleX, provides an effective framework for highly accurate nodule malignancy prediction with the model trained on a large patient population. Our results are replicable with software available at http://bioinformatics.astate.edu/NoduleX .


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico , Modelos Biológicos , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Estudos de Coortes , Bases de Dados como Assunto , Humanos , Processamento de Imagem Assistida por Computador , Redes Neurais de Computação , Curva ROC , Software
12.
Med Phys ; 44(6): 2438-2446, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28295418

RESUMO

PURPOSE: To evaluate and compare the theoretically achievable accuracy of two families of two-parameter photon cross-section models: basis vector model (BVM) and modified parametric fit model (mPFM). METHOD: The modified PFM assumes that photoelectric absorption and scattering cross-sections can be accurately represented by power functions in effective atomic number and/or energy plus the Klein-Nishina cross-section, along with empirical corrections that enforce exact prediction of elemental cross-sections. Two mPFM variants were investigated: the widely used Torikoshi model (tPFM) and a more complex "VCU" variant (vPFM). For 43 standard soft and bony tissues and phantom materials, all consisting of elements with atomic number less than 20 (except iodine), we evaluated the theoretically achievable accuracy of tPFM and vPFM for predicting linear attenuation, photoelectric absorption, and energy-absorption coefficients, and we compared it to a previously investigated separable, linear two-parameter model, BVM. RESULTS: For an idealized dual-energy computed tomography (DECT) imaging scenario, the cross-section mapping process demonstrates that BVM more accurately predicts photon cross-sections of biological mixtures than either tPFM or vPFM. Maximum linear attenuation coefficient prediction errors were 15% and 5% for tPFM and BVM, respectively. The root-mean-square (RMS) prediction errors of total linear attenuation over the 20 keV to 1000 keV energy range of tPFM and BVM were 0.93% (tPFM) and 0.1% (BVM) for adipose tissue, 0.8% (tPFM) and 0.2% (BVM) for muscle tissue, and 1.6% (tPFM) and 0.2% (BVM) for cortical bone tissue. With exception of the thyroid and Teflon, the RMS error for photoelectric absorption and scattering coefficient was within 4% for the tPFM and 2% for the BVM. Neither model predicts the photon cross-sections of thyroid tissue accurately, exhibiting relative errors as large as 20%. For the energy-absorption coefficients prediction error, RMS errors for the BVM were less than 1.5%, while for the tPFM, the RMS errors were as large as 16%. CONCLUSION: Compared to modified PFMs, BVM shows superior potential to support dual-energy CT cross-section mapping. In addition, the linear, separable BVM can be more efficiently deployed by iterative model-based DECT image-reconstruction algorithms.


Assuntos
Algoritmos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Humanos , Modelos Estatísticos , Fótons
13.
IEEE Trans Med Imaging ; 25(10): 1392-404, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17024842

RESUMO

We address the problem of image formation in transmission tomography when metal objects of known composition and shape, but unknown pose, are present in the scan subject. Using an alternating minimization (AM) algorithm, derived from a model in which the detected data are viewed as Poisson-distributed photon counts, we seek to eliminate the streaking artifacts commonly seen in filtered back projection images containing high-contrast objects. We show that this algorithm, which minimizes the I-divergence (or equivalently, maximizes the log-likelihood) between the measured data and model-based estimates of the means of the data, converges much faster when knowledge of the high-density materials (such as brachytherapy applicators or prosthetic implants) is exploited. The algorithm incorporates a steepest descent-based method to find the position and orientation (collectively called the pose) of the known objects. This pose is then used to constrain the image pixels to their known attenuation values, or, for example, to form a mask on the "missing" projection data in the shadow of the objects. Results from two-dimensional simulations are shown in this paper. The extension of the model and methods used to three dimensions is outlined.


Assuntos
Artefatos , Inteligência Artificial , Reconhecimento Automatizado de Padrão/métodos , Próteses e Implantes , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Metais , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação
14.
Phys Med Biol ; 51(21): 5603-19, 2006 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-17047273

RESUMO

Two iterative methods are developed for forming a maximum-likelihood estimate of the attenuation density in a patient or object for transmission tomography when projection data are incomplete. The methods converge monotonically to the same limit points. Results of testing the methods with both simulated and real data are given.


Assuntos
Processamento de Imagem Assistida por Computador , Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia por Raios X/instrumentação , Tomografia por Raios X/métodos , Algoritmos , Simulação por Computador , Humanos , Aumento da Imagem , Funções Verossimilhança , Modelos Estatísticos , Método de Monte Carlo , Imagens de Fantasmas
15.
IEEE Trans Med Imaging ; 35(2): 685-98, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26469126

RESUMO

We propose a new algorithm, called line integral alternating minimization (LIAM), for dual-energy X-ray CT image reconstruction. Instead of obtaining component images by minimizing the discrepancy between the data and the mean estimates, LIAM allows for a tunable discrepancy between the basis material projections and the basis sinograms. A parameter is introduced that controls the size of this discrepancy, and with this parameter the new algorithm can continuously go from a two-step approach to the joint estimation approach. LIAM alternates between iteratively updating the line integrals of the component images and reconstruction of the component images using an image iterative deblurring algorithm. An edge-preserving penalty function can be incorporated in the iterative deblurring step to decrease the roughness in component images. Images from both simulated and experimentally acquired sinograms from a clinical scanner were reconstructed by LIAM while varying the regularization parameters to identify good choices. The results from the dual-energy alternating minimization algorithm applied to the same data were used for comparison. Using a small fraction of the computation time of dual-energy alternating minimization, LIAM achieves better accuracy of the component images in the presence of Poisson noise for simulated data reconstruction and achieves the same level of accuracy for real data reconstruction.


Assuntos
Algoritmos , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Absorciometria de Fóton , Humanos , Modelos Biológicos , Imagens de Fantasmas
16.
Med Phys ; 32(11): 3295-304, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16372410

RESUMO

Techniques have been developed for reducing motion blurring artifacts by using respiratory gated computed tomography (CT) in sinogram space and quantitatively evaluating the artifact reduction. A synthetic sinogram was built from multiple scans intercepting a respiratory gating window. A gated CT image was then reconstructed using the filtered back-projection algorithm. Wedge phantoms, developed for quantifying the motion artifact reduction, were scanned while being moved using a computer-controlled linear stage. The resulting artifacts appeared between the high and low density regions as an apparent feature with a Hounsfield value that was the average of the two regions. A CT profile through these regions was fit using two error functions, each modeling the partial-volume averaging characteristics for the unmoving phantom. The motion artifact was quantified by determining the apparent distance between the two functions. The blurring artifact had a linear relationship with both the speed and the tangent of the wedge angles. When gating was employed, the blurring artifact was reduced systematically at the air-phantom interface. The gated image of phantoms moving at 20 mm/s showed similar blurring artifacts as the nongated image of phantoms moving at 10 mm/s. Nine patients were also scanned using the synchronized respiratory motion technique. Image artifacts were evaluated in the diaphragm, where high contrast interfaces intercepted the imaging plane. For patients, this respiratory gating technique reduced the blurring artifacts by 9%-41% at the lung-diaphragm interface.


Assuntos
Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Ar , Algoritmos , Artefatos , Estudos de Avaliação como Assunto , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Pulmão/patologia , Modelos Estatísticos , Movimento (Física) , Movimento , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Assistida por Computador , Radioterapia Conformacional , Reprodutibilidade dos Testes , Fatores de Tempo
17.
Med Phys ; 42(6): 2908-14, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26127044

RESUMO

PURPOSE: To provide a noninvasive technique to measure the intensity profile of the fan beam in a computed tomography (CT) scanner that is cost effective and easily implemented without the need to access proprietary scanner information or service modes. METHODS: The fabrication of an inexpensive aperture is described, which is used to expose radiochromic film in a rotating CT gantry. A series of exposures is made, each of which is digitized on a personal computer document scanner, and the resulting data set is analyzed to produce a self-consistent calibration of relative radiation exposure. The bow tie profiles were analyzed to determine the precision of the process and were compared to two other measurement techniques, direct measurements from CT gantry detectors and a dynamic dosimeter. RESULTS: The radiochromic film method presented here can measure radiation exposures with a precision of ∼ 6% root-mean-square relative error. The intensity profiles have a maximum 25% root-mean-square relative error compared with existing techniques. CONCLUSIONS: The proposed radiochromic film method for measuring bow tie profiles is an inexpensive (∼$100 USD + film costs), noninvasive method to measure the fan beam intensity profile in CT scanners.


Assuntos
Dosimetria Fotográfica/métodos , Tomografia Computadorizada por Raios X/instrumentação , Rotação
18.
Med Phys ; 29(10): 2404-18, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12408315

RESUMO

X-ray computed tomography (CT) images of patients bearing metal intracavitary applicators or other metal foreign objects exhibit severe artifacts including streaks and aliasing. We have systematically evaluated via computer simulations the impact of scattered radiation, the polyenergetic spectrum, and measurement noise on the performance of three reconstruction algorithms: conventional filtered backprojection (FBP), deterministic iterative deblurring, and a new iterative algorithm, alternating minimization (AM), based on a CT detector model that includes noise, scatter, and polyenergetic spectra. Contrary to the dominant view of the literature, FBP streaking artifacts are due mostly to mismatches between FBP's simplified model of CT detector response and the physical process of signal acquisition. Artifacts on AM images are significantly mitigated as this algorithm substantially reduces detector-model mismatches. However, metal artifacts are reduced to acceptable levels only when prior knowledge of the metal object in the patient, including its pose, shape, and attenuation map, are used to constrain AM's iterations. AM image reconstruction, in combination with object-constrained CT to estimate the pose of metal objects in the patient, is a promising approach for effectively mitigating metal artifacts and making quantitative estimation of tissue attenuation coefficients a clinical possibility.


Assuntos
Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Metais , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Braquiterapia/métodos , Simulação por Computador , Humanos , Modelos Estatísticos , Imagens de Fantasmas , Fótons , Espalhamento de Radiação , Raios X
19.
Med Phys ; 30(6): 1254-63, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12852551

RESUMO

Breathing motion is a significant source of error in radiotherapy treatment planning for the thorax and upper abdomen. Accounting for breathing motion has a profound effect on the size of conformal radiation portals employed in these sites. Breathing motion also causes artifacts and distortions in treatment planning computed tomography (CT) scans acquired during free breathing and also causes a breakdown of the assumption of the superposition of radiation portals in intensity-modulated radiation therapy, possibly leading to significant dose delivery errors. Proposed voluntary and involuntary breath-hold techniques have the potential for reducing or eliminating the effects of breathing motion, however, they are limited in practice, by the fact that many lung cancer patients cannot tolerate holding their breath. We present an alternative solution to accounting for breathing motion in radiotherapy treatment planning, where multislice CT scans are collected simultaneously with digital spirometry over many free breathing cycles to create a four-dimensional (4-D) image set, where tidal lung volume is the additional dimension. An analysis of this 4-D data leads to methods for digital-spirometry, based elimination or accounting of breathing motion artifacts in radiotherapy treatment planning for free breathing patients. The 4-D image set is generated by sorting free-breathing multislice CT scans according to user-defined tidal-volume bins. A multislice CT scanner is operated in the ciné mode, acquiring 15 scans per couch position, while the patient undergoes simultaneous digital-spirometry measurements. The spirometry is used to retrospectively sort the CT scans by their correlated tidal lung volume within the patient's normal breathing cycle. This method has been prototyped using data from three lung cancer patients. The actual tidal lung volumes agreed with the specified bin volumes within standard deviations ranging between 22 and 33 cm3. An analysis of sagittal and coronal images demonstrated relatively small (<1 cm) motion artifacts along the diaphragm, even for tidal volumes where the rate of breathing motion is greatest. While still under development, this technology has the potential for revolutionizing the radiotherapy treatment planning for the thorax and upper abdomen.


Assuntos
Artefatos , Imageamento Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Movimento , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiometria/métodos , Respiração , Espirometria/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Retroalimentação , Feminino , Humanos , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Masculino , Postura , Controle de Qualidade , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração
20.
Med Phys ; 41(10): 101915, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25281967

RESUMO

PURPOSE: Several areas of computed tomography (CT) research require knowledge about the intensity profile of the x-ray fan beam that is introduced by a bow tie filter. This information is considered proprietary by CT manufacturers, so noninvasive measurement methods are required. One method using real-time dosimeters has been proposed in the literature. A commercially available dosimeter was used to apply that method, and analysis techniques were developed to extract fan beam profiles from measurements. METHODS: A real-time ion chamber was placed near the periphery of an empty CT gantry and the dose rate versus time waveform was recorded as the x-ray source rotated about the isocenter. In contrast to previously proposed analysis methods that assumed a pointlike detector, the finite-size ion chamber received varying amounts of coverage by the collimated x-ray beam during rotation, precluding a simple relationship between the source intensity as a function of fan beam angle and measured intensity. A two-parameter model for measurement intensity was developed that included both effective collimation width and source-to-detector distance, which then was iteratively solved to minimize the error between duplicate measurements at corresponding fan beam angles, allowing determination of the fan beam profile from measured dose-rate waveforms. Measurements were performed on five different scanner systems while varying parameters such as collimation, kVp, and bow tie filters. On one system, direct measurements of the bow tie profile were collected for comparison with the real-time dosimeter technique. RESULTS: The data analysis method for a finite-size detector was found to produce a fan beam profile estimate with a relative error between duplicate measurement intensities of <5%. It was robust over a wide range of collimation widths (e.g., 1-40 mm), producing fan beam profiles that agreed with a relative error of 1%-5%. Comparison with a direct measurement technique on one system produced agreement with a relative error of 2%-6%. Fan beam profiles were found to differ for different filter types on a given system and between different vendors. CONCLUSIONS: A commercially available real-time dosimeter probe was found to be a convenient and accurate instrument for measuring fan beam profiles. An analysis method was developed that could handle a wide range of collimation widths by explicitly considering the finite width of the ion chamber. Relative errors in the profiles were found to be less than 5%. Measurements of five different clinical scanners demonstrate the variation in bow tie designs, indicating that generic bow tie models will not be adequate for CT system research.


Assuntos
Radiometria/instrumentação , Radiometria/métodos , Tomógrafos Computadorizados , Algoritmos , Modelos Teóricos , Tomografia Computadorizada por Raios X , Raios X