Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Eixos temáticos
Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 25(Pt 2): 580-591, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29488940

RESUMO

An end-station for resonant inelastic X-ray scattering and (resonant) X-ray emission spectroscopy at beamline ID20 of ESRF - The European Synchrotron is presented. The spectrometer hosts five crystal analysers in Rowland geometry for large solid angle collection and is mounted on a rotatable arm for scattering in both the horizontal and vertical planes. The spectrometer is optimized for high-energy-resolution applications, including partial fluorescence yield or high-energy-resolution fluorescence detected X-ray absorption spectroscopy and the study of elementary electronic excitations in solids. In addition, it can be used for non-resonant inelastic X-ray scattering measurements of valence electron excitations.

2.
J Synchrotron Radiat ; 24(Pt 2): 521-530, 2017 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28244449

RESUMO

An end-station for X-ray Raman scattering spectroscopy at beamline ID20 of the European Synchrotron Radiation Facility is described. This end-station is dedicated to the study of shallow core electronic excitations using non-resonant inelastic X-ray scattering. The spectrometer has 72 spherically bent analyzer crystals arranged in six modular groups of 12 analyzer crystals each for a combined maximum flexibility and large solid angle of detection. Each of the six analyzer modules houses one pixelated area detector allowing for X-ray Raman scattering based imaging and efficient separation of the desired signal from the sample and spurious scattering from the often used complicated sample environments. This new end-station provides an unprecedented instrument for X-ray Raman scattering, which is a spectroscopic tool of great interest for the study of low-energy X-ray absorption spectra in materials under in situ conditions, such as in operando batteries and fuel cells, in situ catalytic reactions, and extreme pressure and temperature conditions.

3.
Phys Med Biol ; 39(3): 583-95, 1994 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15551600

RESUMO

A new system has been designed and built to validate the concept of 3D computerized angiography (CA). This system can acquire a set of 2D digital subtracted angiography images while rotating around a patient and then, using these images, reconstruct a 3D representation of the opacified vasculature. The design principles and main characteristics of the system are described, with special attention paid to data processing aspects. An initial in vivo evaluation of this system performed on anaesthetized animals and human volunteers is presented. The influence on the quality of the 3D reconstruction of different factors such as volume resolution, estimation method, source trajectory and number of projections is discussed.


Assuntos
Angiografia/instrumentação , Angiografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Animais , Aorta/patologia , Calibragem , Artérias Carótidas/patologia , Cães , Estudos de Avaliação como Assunto , Humanos , Software , Fatores de Tempo
4.
Comput Med Imaging Graph ; 17(4-5): 295-300, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8306301

RESUMO

Reconstructing a three-dimensional (3D) object from a set of its two-dimensional (2D) X-ray projections requires that the source position and image plane orientation in 3D space be obtained with high accuracy. We present a method for estimating the geometrical parameters of an X-ray imaging chain, based on the minimization of the reprojection mean quadratic error measured on reference points of a calibration phantom. This error is explicitly calculated with respect to the geometrical parameters of the conic projection, and a conjugate gradient technique is used for its minimization. By comparison to the classical unconstrained method, better results were obtained in simulation with our method, specially when only a few reference points are available. This method may be adapted to different X-ray systems and may also be extended to the estimation of the geometrical parameters of the imaging chain trajectory in the case of dynamic acquisitions.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Radiografia Intervencionista , Calibragem , Humanos , Modelos Estruturais
5.
J Synchrotron Radiat ; 14(Pt 5): 409-15, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17717382

RESUMO

The present paper demonstrates the feasibility of X-ray absorption spectroscopy (XAS) and X-ray magnetic circular dichroism (XMCD) under high magnetic fields up to 26 T and low temperatures down to 5 K on the ID24 energy-dispersive XAS beamline of the ESRF. The pulsed magnetic field set-up, entirely developed at the ESRF, is described as well as the beamline set-up, the synchronization and the measurement procedure. It allows field strengths up to 30 T. Finally, as an example, we report a recent XMCD study at the Re L2 and L3 absorption edges of the double perovskite Sr2CrReO(6).

6.
J Synchrotron Radiat ; 12(Pt 4): 467-72, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15968123

RESUMO

A dispersion-compensation method to remove the cube-size effect from the resolution function of diced analyzer crystals using a position-sensitive two-dimensional pixel detector is presented. For demonstration, a resolution of 23 meV was achieved with a spectrometer based on a 1 m Rowland circle and a diced Si(555) analyzer crystal in a near-backscattering geometry, with a Bragg angle of 88.5 degrees . In this geometry the spectrometer equipped with a traditional position-insensitive detector provides a resolution of 190 meV. The dispersion-compensation method thus allows a substantial increase in the resolving power without any loss of signal intensity.


Assuntos
Processamento de Sinais Assistido por Computador/instrumentação , Espectrometria por Raios X/instrumentação , Transdutores , Difração de Raios X/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Espectrometria por Raios X/métodos , Difração de Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa