Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 190
Filtrar
1.
Acta Endocrinol (Buchar) ; 16(2): 256-261, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33029246

RESUMO

INTRODUCTION: Clinical or subclinical hypothyroidism dictates the severity of depressive episodes and more frequently overlaps psychotic phenomenology. There are also major depressive episodes resistant to treatment in patients with euthyroidism, in which supplementation of antidepressant medication with thyroid hormones is beneficial. MATERIAL: Systematization of meta-analyses from perspectives: hypothyroidism and depression, autoimmune and depression pathology, gestational and puerperal pathology in association with hormonal and dispositional changes, presentation of therapeutic schemes. RESULTS: Hypothyroidism is more commonly comorbid with major depression in women. It associates the need for hospitalizations, psychotic phenomenology, resistance to treatment, somatic comorbidities. Autoimmune pathology is associated with depression and requires thorough investigation. A possible genetic candidate for thyroid dysfunction is the DIO1 gene. FT4 may be a predictor, but the combination of FT4 + TBG measured during the prenatal period has a higher prognostic power for a future depressive episode. CONCLUSION: The article presents psychiatric medication schemes that combine antidepressants and antipsychotics of various classes with other enhancers, an important role going back to step three, which includes thyroid hormones, mainly T3. The doses used are smaller than the amount of endogenous production of T3 daily, with a small risk of inducing clinical hyperthyroidism.

2.
Acta Endocrinol (Buchar) ; 15(3): 410-415, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32010366

RESUMO

INTRODUCTION: Ties between the endocrine system and mental health are undeniably a consistent point of interest in modern day medicine. Furthermore, mental disturbances due to hormonal changes following childbirth have been mentioned in medical literature since Hippocrates. Considering the dramatic endocrine, paracrine and autocrine changes that occur during gestation, labour and postnatal phase, hormonal theories are not to be ignored in the treatment of postpartum disorders. RESULTS: Reproductive hormones are known to modulate behavioural, emotional and cognitive response, therefore rapid changes in estradiol and progesterone plasma concentrations during pregnancy and labour create a vulnerable terrain leading towards postpartum disorders. New research shows that women suffering from postpartum disorders have abnormal neural responses, suggesting a neuroendocrine explanation for postpartum syndromes. CONCLUSION: To facilitate further research in this area, we present new information on several hormonal interactions and the psychiatric response involved in pregnancy and labour, offering an interdisciplinary outlook on pregnancy and postpartum disorders. There is enough evidence to suggest that estradiol, progesterone, oxytocin, cortisol and thyroid hormones are some of many hormones involved in postpartum syndromes and tackling their perinatal imbalance with pharmacological substituents or antagonists could be useful as an adjuvant form of treatment in future patients.

3.
Acta Endocrinol (Buchar) ; 14(3): 394-400, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-31149289

RESUMO

CONTEXT: Nonalcoholic fatty liver disease is common in type 2 diabetes mellitus patients, being difficult to diagnose. OBJECTIVE: To find a correlation between elastographic parameters and lab results, for facilitating the diagnosis of nonalcoholic fatty liver disease. DESIGN: This is a cross sectional study, conducted at the Departments of Diabetes, Nutrition and Metabolic Diseases, and Gastroenterology and Hepatology, of the Clinical Emergency Hospital "Pius Brinzeu" Timisoara. SUBJECTS AND METHODS: We included 190 type 2 diabetes mellitus patients, collected data regarding medical history, clinical and biological features and applied the Alcohol Use Disorders Identification Test. We excluded patients with other causes of liver disease. Liver steatosis and fibrosis were evaluated through transient elastography, yielding two parameters: liver stiffness as an indicator of liver fibrosis stage, expressed in kPa, and liver steatosis stage, assessed by controlled attenuation parameter, expressed in dB/m. Data were analyzed using SPSS 15. RESULTS: The analyzed group comprised 113 patients. Elastographic measurements showed that 93.8% of the patients had steatosis (controlled attenuation parameter ≥232.5 dB/m) and 70.8% severe steatosis (controlled attenuation parameter ≥290 dB/m). Severe steatosis was more common in women (75.7%) than in men (68.1%) (p<0.0001). From the patients with steatosis, 47.2% had liver stiffness values suggestive for fibrosis and 19.8% for cirrhosis. Most patients with steatosis and severe fibrosis were obese (66.7%). Triglycerides/HDLc ratio >4 correlated with hepatic steatosis (p=0.04), being more common in patients with severe fibrosis/cirrhosis (58.3%) than in those with absent or mild fibrosis (36.2%). CONCLUSIONS: Our study found a clear correlation between type 2 diabetes mellitus and the presence of liver steatosis. It correlates with body mass index, waist circumference (in men) and triglycerides/HDLc ratio. Controlled attenuation parameter is a useful noninvasive method for detection and quantification of liver steatosis.

4.
Chemistry ; 21(23): 8613-25, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-25926362

RESUMO

Oxidation of the 1,2-(PR2 )2 -1,2-closo-C2 B10 H10 (R=Ph, iPr) platform with hydrogen peroxide in acetone is a two-step procedure in which partial deboronation of the closo cluster and oxidation of the phosphorus atoms occur. Based on NMR spectroscopic and kinetic data, we demonstrate that the phosphorus atoms are oxidized in the first step, followed by cluster deboronation. DFT calculations and natural-bond orbital (NBO) analysis were used to obtain insight into the electronic structures of diphosphane ortho-carborane derivatives.

5.
Ultraschall Med ; 35(3): 259-66, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24563420

RESUMO

PURPOSE: To assess the value of contrast-enhanced ultrasound (CEUS) for differentiating malignant from benign focal liver lesions (FLLs) and for diagnosing different FLL types. MATERIAL AND METHODS: CEUS performed in 14 Romanian centers was prospectively collected between February 2011 and June 2012. The inclusion criteria were: age > 18 years; patients diagnosed with 1 - 3 de novo FLLs on B-mode ultrasound; reference method (computed tomography (CT), magnetic resonance imaging (MRI) or biopsy) available; patient's informed consent. FLL lesions were characterized during CEUS according to the European Federation of Societies for Ultrasound in Medicine and Biology guidelines. For statistical analysis, indeterminate FLLs at CEUS were rated as false classifications. RESULTS: A total number of 536 cases were included in the final analysis, 344 malignant lesions (64.2 %) and 192 benign lesions (35.8 %). The reference method was: CT/MRI - 379 cases (70.7 %), pathological exam - 150 cases (27.9 %) and aspiration of liver abscesses - 7 cases (1.4 %). CEUS was conclusive in 89.3 % and inconclusive in 10.7 % of cases. To differentiate between malignant and benign FLLs, CEUS had 85.7 % sensitivity, 85.9 % specificity, 91.6 % positive predictive value, 77.1 % negative predictive value and 85.8 % accuracy. The CEUS accuracy for differentiation between malignant and benign liver lesions was similar in tumors with diameter ≤ 2 cm and those with diameter > 2 cm. CONCLUSION: CEUS represents a useful method in clinical practice for differentiating between malignant and benign FLLs detected on standard ultrasonography, and the results of this study are in concordance with previous multicenter studies: DEGUM (Germany) and STIC (France).


Assuntos
Meios de Contraste , Aumento da Imagem/métodos , Hepatopatias/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Abscesso Hepático/diagnóstico por imagem , Abscesso Hepático/patologia , Hepatopatias/patologia , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Valores de Referência , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Ultrassonografia , Adulto Jovem
6.
J Mater Sci Mater Med ; 24(12): 2695-707, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23943017

RESUMO

Radio-frequency Plasma Enhanced Chemical Vapour Deposition (in different methane dilutions) was used to synthesize adherent and haemocompatible diamond-like carbon (DLC) films on medical grade titanium substrates. The improvement of the adherence has been achieved by interposing a functional buffer layer with graded composition TixTiC1-x (x = 0-1) synthesized by magnetron co-sputtering. Bonding strength values of up to ~67 MPa have been measured by pull-out tests. Films with different sp(3)/sp(2) ratio have been obtained by changing the methane concentration in the deposition chamber. Raman spectroscopy, X-ray photoelectron spectroscopy and X-ray diffraction were employed for the physical-chemical characterization of the samples. The highest concentration of sp(3)-C (~87 %), corresponding to a lower DLC surface energy (28.7 mJ/m(2) ), was deposited in a pure methane atmosphere. The biological response of the DLC films was assayed by a state-of-the-art biological analysis method (surface enhanced laser desorption/ionization-time of flight mass spectroscopy), in conjunction with other dedicated testing techniques: Western blot and partial thromboplastin time. The data support a cause-effect relationship between sp(3)-C content, surface energy and coagulation time, as well as between platelet-surface adherence properties and protein adsorption profiles.


Assuntos
Carbono/química , Materiais Revestidos Biocompatíveis/química , Diamante/química , Adsorção , Humanos , Espectrometria de Massas , Teste de Materiais , Metano/química , Tempo de Tromboplastina Parcial , Espectroscopia Fotoeletrônica , Adesividade Plaquetária , Análise Espectral Raman , Propriedades de Superfície , Titânio/química , Difração de Raios X
7.
Chirurgia (Bucur) ; 108(1): 86-90, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23464775

RESUMO

UNLABELLED: The aim of the paper was to evaluate the national availability of colonoscopy and the quality parameters of this procedure in our country. MATERIAL AND METHOD: During a 6 months period (01.07- 31.12.2009), we performed a prospective multicenter study in which 76 centers were invited to respond to a questionnaire regarding colonoscopy, 39 centers agreeing to participate. We assessed: the number of colonoscopies, the number of total colonoscopies and the causes of incomplete colonoscopies. RESULTS: During the study period, 16,083 colonoscopies were performed, 12,294 (76.4%) of them total colonoscopies. In 1,191 cases, stenosis was the cause of incomplete colonoscopy. If we consider this an objective reason for an incomplete colonoscopy, there were 12,294 total colonoscopies (82.4%). Comparing university centers with non-university ones, the proportion of total colonoscopies was 10,400/12,475 (83.4%) vs. 1,894/2,417 (78.4%) (p less then 0.0001). However, comparing the present study with previous ones, performed in 2003 and 2007, the proportion of total colonoscopies increased from 70.5% to 76.9% and 82.4% respectively (2003 vs. 2007 p less then 0.0001; 2007 vs. 2009 p less then 0.0001), while the quality difference between university and non-university hospitals persisted. CONCLUSIONS: the quality of colonoscopy in Romania increased in the last 5 years, while the quality difference between university and non-university hospitals persisted.


Assuntos
Neoplasias do Colo/diagnóstico , Colonoscopia/normas , Detecção Precoce de Câncer/normas , Neoplasias do Colo/epidemiologia , Colonoscopia/estatística & dados numéricos , Detecção Precoce de Câncer/estatística & dados numéricos , Hospitais Comunitários/estatística & dados numéricos , Hospitais Universitários/estatística & dados numéricos , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Risco , Romênia/epidemiologia , Sensibilidade e Especificidade , Inquéritos e Questionários
8.
Chirurgia (Bucur) ; 107(3): 352-60, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22844834

RESUMO

Videocapsule endoscopy (VCE) can identify lesions in the small bowel which would otherwise be hard to detect. We have selected 53 patients with digestive symptoms in which upper and lower endoscopy had provided no findings. Patients were classified into three groups, based on their main indication for VCE exploration: group one--obscure gastrointestinal bleeding (OGIB); group two--unspecific abdominal symptoms; group 3--monitoring of a prior known pathology. We found that VCE has high predictive values, sensibility and specificity in the diagnosis of OGIB. VCE was also useful in the detection and extent evaluation of lesions in Crohn's and celiac disease. VCE is also able to detect tumors of the small bowel with sufficient accuracy, and can be used to monitor patients with hereditary pre-malignant diseases such as FAP. There were few light adverse effects and no major complications. We conclude that VCE is a safe and effective procedure for the detection of small bowel lesions.


Assuntos
Endoscopia por Cápsula , Hemorragia Gastrointestinal/patologia , Enteropatias/diagnóstico , Intestino Delgado/patologia , Adolescente , Adulto , Idoso , Endoscopia por Cápsula/efeitos adversos , Doença Celíaca/patologia , Doença de Crohn/patologia , Estudos de Viabilidade , Feminino , Hemorragia Gastrointestinal/etiologia , Humanos , Ileíte/patologia , Enteropatias/complicações , Enteropatias/patologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
10.
Ultraschall Med ; 32 Suppl 1: S46-52, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20603783

RESUMO

PURPOSE: To compare two methods of noninvasive assessment: transient elastography (TE) and acoustic radiation force impulse elastography (ARFI). PATIENTS AND METHODS: Our study included 114 subjects: 38 healthy volunteers, (considered to have no fibrosis - F 0) and 76 patients with chronic liver disease: 53 who had undergone liver biopsy (LB) (7 with F 1, 24 with F 2, 22 with F 3 Metavir) and 23 previously diagnosed with cirrhosis (F4 Metavir). In each patient we performed a liver stiffness measurement by means of TE and ARFI. ARFI (shear wave velocity quantification) was performed at 3 points: at 0 - 1 cm, at 1 - 2 cm and at 2 - 3 cm under the capsule. For each depth, 5 valid measurements were made, and a median value was calculated, measured in m/sec. RESULTS: A direct, strong, linear correlation (Spearman rho = 0.848) was found between TE and the stage of fibrosis (p < 0.001). A significant, direct correlation was found between ARFI measurements made 1 - 2 cm and 2 - 3 cm below the liver capsule and the severity of fibrosis (rho = 0.675 and 0.714 respectively). The subcapsularly measured ARFI values showed a poor correlation with fibrosis (rho = 0.469). The best test for predicting significant fibrosis (F ≥ 2) was TE, with the area under receiver-operating characteristic curve (AUROC) 0.908, significantly larger than the AUROCs for ARFI. If only ARFI is considered, measurements made 1 - 2 and 2 - 3 cm below the capsule have the best predictive value, with AUROCs not significantly different from each other (0.767 and 0.731, respectively). For predicting fibrosis (F > 0), TE had the best predictive value: optimized cut-off 5.65 kPa (AUROC -0.898). For ARFI, the cut-offs were: 1.4 m/sec, AUROC -0.747 (1 - 2 cm), and 1.26 m/sec AUROC -0.721 (2 - 3 cm). For predicting cirrhosis (F = 4 Metavir), the optimized cut-offs were: TE -12.9 kPa (AUROC -0.994); ARFI - 1.78 m/sec for measurements made 2 - 3 cm below the capsule, AUROC - 0.951. CONCLUSION: At present, liver elasticity evaluation by means of ARFI is not superior to TE for the assessment of liver fibrosis. For ARFI, the most reliable results are obtained if measurements are made 1 - 2 and 2 - 3 cm below the liver capsule. ARFI is an accurate test for the diagnosis of cirrhosis.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatite Crônica/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Adulto , Biópsia , Feminino , Hepatite B Crônica/diagnóstico por imagem , Hepatite B Crônica/patologia , Hepatite C Crônica/diagnóstico por imagem , Hepatite C Crônica/patologia , Hepatite Alcoólica/diagnóstico por imagem , Hepatite Alcoólica/patologia , Hepatite Crônica/patologia , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/patologia , Cirrose Hepática Biliar/diagnóstico por imagem , Cirrose Hepática Biliar/patologia , Testes de Função Hepática , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa