Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Sci Rep ; 14(1): 3522, 2024 02 12.
Artigo em Inglês | MEDLINE | ID: mdl-38347017

RESUMO

In medical imaging, accurate segmentation is crucial to improving diagnosis, treatment, or both. However, navigating the multitude of available architectures for automatic segmentation can be overwhelming, making it challenging to determine the appropriate type of architecture and tune the most crucial parameters during dataset optimisation. To address this problem, we examined and refined seven distinct architectures for segmenting the liver, as well as liver tumours, with a restricted training collection of 60 3D contrast-enhanced magnetic resonance images (CE-MRI) from the ATLAS dataset. Included in these architectures are convolutional neural networks (CNNs), transformers, and hybrid CNN/transformer architectures. Bayesian search techniques were used for hyperparameter tuning to hasten convergence to the optimal parameter mixes while also minimising the number of trained models. It was unexpected that hybrid models, which typically exhibit superior performance on larger datasets, would exhibit comparable performance to CNNs. The optimisation of parameters contributed to better segmentations, resulting in an average increase of 1.7% and 5.0% in liver and tumour segmentation Dice coefficients, respectively. In conclusion, the findings of this study indicate that hybrid CNN/transformer architectures may serve as a practical substitute for CNNs even in small datasets. This underscores the significance of hyperparameter optimisation.


Assuntos
Processamento de Imagem Assistida por Computador , Neoplasias Hepáticas , Humanos , Teorema de Bayes , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias Hepáticas/diagnóstico por imagem
2.
Phys Med ; 115: 103145, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37852020

RESUMO

PURPOSE: The aim of this study was (a) to optimise the99mTc-SPECT reconstruction parameters for the pre-treatment dosimetry of90Y-selective internal radiation therapy (SIRT) and (b) to compare the accuracy of clinical dosimetry methods with full Monte-Carlo dosimetry (fMCD) performed with Gate. METHODS: To optimise the reconstruction parameters, two hundred reconstructions with different parameters were performed on a NEMA phantom, varying the number of iterations, subsets, and post-filtering. The accuracy of the dosimetric methods was then investigated using an anthropomorphic phantom. Absorbed dose maps were generated using (1) the Partition Model (PM), (2) the Dose Voxel Kernel (DVK) convolution, and (3) the Local Deposition Method (LDM) with known activity restricted to the whole phantom (WP) or to the liver and lungs (LL). The dose to the lungs was calculated using the "multiple DVK" and "multiple LDM" methods. RESULTS: Optimal OSEM reconstruction parameters were found to depend on object size and dosimetric criterion chosen (Dmean or DVH-derived metric). The Dmean of all three dosimetric methods was close (≤ 10%) to the Dmean of fMCD simulations when considering large segmented volumes (whole liver, normal liver). In contrast, the Dmean to the small volume (∅=31) was systemically underestimated (12%-25%). For lungs, the "multiple DVK" and "multiple LDM" methods yielded a Dmean within 20% for the WP method and within 10% for the LL method. CONCLUSIONS: All three methods showed a substantial degradation of the dose-volume histograms (DVHs) compared to fMCD simulations. The DVK and LDM methods performed almost equally well, with the "multiple DVK" method being more accurate in the lungs.


Assuntos
Fígado , Radiometria , Método de Monte Carlo , Imagens de Fantasmas , Tomografia Computadorizada de Emissão de Fóton Único , Radioisótopos de Ítrio
3.
Diagnostics (Basel) ; 11(9)2021 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-34573873

RESUMO

The aim of our study was to assess the efficacy of a computed tomography (CT)-Navigation™ electromagnetic system compared to conventional CT methods for percutaneous lung biopsies (PLB). In this single-center retrospective study, data of a CT-Navigation™ system guided PLB (NAV-group) and conventional CT PLB (CT-group) performed between January 2017 and February 2020 were reviewed. The primary endpoint was the diagnostic success. Secondary endpoints were technical success, total procedure duration, number of CT acquisitions and the dose length product (DLP) during step ∆1 (from planning to initial needle placement), step ∆2 (progression to target), and the entire intervention (from planning to final control) and complications. Additional parameters were recorded, such as the lesion's size and trajectory angles. Sixty patients were included in each group. The lesions median size and median values of the two trajectory angles were significantly lower (20 vs. 29.5 mm, p = 0.006) and higher in the NAV-group (15.5° and 10° vs. 6° and 1°; p < 0.01), respectively. Technical and diagnostic success rates were similar in both groups, respectively 95% and 93.3% in the NAV-group, and 93.3% and 91.6% in the CT-group. There was no significant difference in total procedure duration (p = 0.487) and total number of CT acquisitions (p = 0.066), but the DLP was significantly lower in the NAV-group (p < 0.01). There was no significant difference in complication rate. For PLB, CT-Navigation™ system is efficient and safe as compared to the conventional CT method.

4.
Diagnostics (Basel) ; 11(1)2021 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-33466706

RESUMO

Liver tumors are common and may be unamenable to surgery or ablative treatments. Consequently, other treatments have been devised. To assess the safety and efficacy of transarterial radioembolization (TARE) with Yttrium-90 for hepatocellular carcinoma (HCC), liver-dominant hepatic colorectal cancer metastases (mCRC), and cholangiocarcinoma (CCA), performed according to current recommendations, we conducted a single-center retrospective study in 70 patients treated with TARE (HCC, n = 44; mCRC, n = 20; CCA, n = 6). Safety and toxicity were assessed using the National Cancer Institute Common Terminology Criteria. Treatment response was evaluated every 3 months on imaging studies using Response Evaluation Criteria in Solid Tumors (RECIST) or mRECIST criteria. Overall survival and progression-free survival were estimated using the Kaplan-Meier method. The median delivered dose was 1.6 GBq, with SIR-Spheres® or TheraSphere® microspheres. TARE-related grade 3 adverse events affected 17.1% of patients. Median follow-up was 32.1 months. Median progression-free survival was 5.6 months and median overall time from TARE to death was 16.1 months and was significantly shorter in men. Progression-free survival was significantly longer in women (HR, 0.49; 95%CI, 0.26-0.90; p = 0.031). Risk of death or progression increased with the number of systemic chemotherapy lines. TARE can be safe and effective in patients with intermediate- or advanced-stage HCC, CCA, or mCRC refractory or intolerant to appropriate treatments.

5.
EJNMMI Res ; 11(1): 24, 2021 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-33687596

RESUMO

INTRODUCTION: The aim of this study was to evaluate the impact of the contouring methods on dose metrics and their predictive value on tumor control and survival, in both situations of pre-treatment and post-treatment dosimetry, for patients with advanced HCC treated with SIRT. METHODS: Forty-eight patients who underwent SIRT between 2012 and 2020 were retrospectively included in this study. Target volumes were delineated using two methods: MRI-based contours manually drawn by a radiologist and then registered on SPECT/CT and PET/CT via deformable registration (Pre-CMRI and Post-CMRI), 99mTc-MAA-SPECT and 90Y-microspheres-PET 10% threshold contouring (Pre-CSPECT and Post-CPET). The mean absorbed dose (Dm) and the minimal absorbed dose delivered to 70% of the tumor volume (D70) were evaluated with both contouring methods; the tumor-to-normal liver uptake ratio (TNR) was evaluated with MRI-based contours only. Tumor response was assessed using the mRECIST criteria on the follow-up MRIs. RESULTS: No significant differences were found for Dm and TNR between pre- and post-treatment. TNR evaluated with radiologic contours (Pre-CMRI and Post-CMRI) were predictive of tumor control at 6 months on pre- and post-treatment dosimetry (OR 5.9 and 7.1, respectively; p = 0.02 and 0.01). All dose metrics determined with both methods were predictive of overall survival (OS) on pre-treatment dosimetry, but only Dm with MRI-based contours was predictive of OS on post-treatment images with a median of 23 months for patients with a supramedian Dm versus 14 months for the others (p = 0.04). CONCLUSION: In advanced HCC treated with SIRT, Dm and TNR determined with radiologic contours were predictive of tumor control and OS. This study shows that a rigorous clinical workflow (radiologic contours + registration on scintigraphic images) is feasible and should be prospectively considered for improving therapeutic strategy.

6.
Phys Rev E Stat Nonlin Soft Matter Phys ; 78(5 Pt 2): 056405, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19113224

RESUMO

An ion projectile stopping at a velocity smaller than the target electron thermal velocity in a strong magnetic field is investigated within a different diffusion formulation, based on Green-Kubo integrands evaluated in magnetized one component plasma models, respectively framed on target ions and electrons. Analytic expressions are reported for slowing down orthogonal and parallel to an arbitrary large magnetic field, which are free from the usual uncertainties plaguing the standard perturbative derivations. Magnetic and target temperature dependences of the low velocity slowing down are thoroughly detailed for dense plasmas of fast ignition concern and ultracold plasmas envisioned for ion beam cooling, as well.

7.
Eur J Radiol ; 106: 20-25, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30150046

RESUMO

PURPOSE: To evaluate the feasibility, safety and usefulness of 3D CBCT with a new injection protocol for targeting the portal vein during TIPS and to determine if it allows decreasing the duration of the procedure. MATERIALS AND METHODS: 3D CBCT was obtained during creation of TIPS in 15 patients (group 2). Portogram quality score was defined using a 5 points scale. The time required to achieve portal puncture was also recorded and results were compared retrospectively in 15 patients who underwent TIPS without 3D CBCT (group 1). RESULTS: The mean time required to puncture the portal vein was shorter when CBCT was used: 15 min versus 24 min (p = 0.156). We recorded 3 failures requiring a second procedure in group 1. There were no complications and no failure in group 2. We recorded 93% of good portography and 80% of good 3D roadmaps. CONCLUSION: 3D CBCT coupled with this new injection protocol provided high rate of good quality portography allowing to bring positional and directional information to improve the needle pass efficiency and to decrease the duration of the procedure.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Fígado/diagnóstico por imagem , Veia Porta/diagnóstico por imagem , Derivação Portossistêmica Transjugular Intra-Hepática , Portografia , Adulto , Idoso , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Veia Porta/cirurgia , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Punções/métodos , Estudos Retrospectivos , Cirurgia Assistida por Computador
8.
Phys Rev E Stat Nonlin Soft Matter Phys ; 80(4 Pt 2): 046408, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19905462

RESUMO

We extend former investigation to a partially degenerate electron fluid at any temperature of multiple slow ion scattering at T=0. We implement an analytic and mean-field interpolation of the target electron dielectric function between T=0 (Lindhard) and T-->infinity (Fried-Conte). A specific attention is given to multiple scattering of proton projectiles in the keV energy range, stopped in a hot-electron plasma at solid density.


Assuntos
Íons Pesados , Temperatura Alta , Modelos Teóricos , Reologia/métodos , Simulação por Computador , Elétrons , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa