Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Brain ; 146(4): 1243-1266, 2023 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-36408715

RESUMO

Myelin is the protective sheath wrapped around axons, consisting of a phospholipid bilayer with water between the wraps. The measurement of damage to the myelin sheaths, the evaluation of the efficacy of therapies aiming to promote remyelination and monitoring the degree of brain maturation in children all require non-invasive quantitative myelin imaging methods. To date, various myelin imaging techniques have been developed. Five different MRI approaches can be distinguished based on their biophysical principles: (i) imaging of the water between the lipid bilayers directly (e.g. myelin water imaging); (ii) imaging the non-aqueous protons of the phospholipid bilayer directly with ultra-short echo-time techniques; (iii) indirect imaging of the macromolecular content (e.g. magnetization transfer; inhomogeneous magnetization transfer); (iv) mapping of the effects of the myelin sheath's magnetic susceptibility on the MRI signal (e.g. quantitative susceptibility mapping); and (v) mapping of the effects of the myelin sheath on water diffusion. Myelin imaging with PET uses radioactive molecules with high affinity to specific myelin components, in particular myelin basic protein. This review aims to give an overview of the various myelin imaging techniques, their biophysical principles, image acquisition, data analysis and their validation status.


Assuntos
Doenças Desmielinizantes , Bainha de Mielina , Criança , Humanos , Bainha de Mielina/metabolismo , Doenças Desmielinizantes/metabolismo , Imageamento por Ressonância Magnética/métodos , Axônios , Tomografia por Emissão de Pósitrons , Encéfalo
2.
Neuroimage ; 265: 119785, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36464096

RESUMO

BACKGROUND: To investigate the association of ihMT (inhom signals with the demyelination and remyelination phases of the acute cuprizone mouse model in comparison with histology, and to assess the extent of tissue damage and repair from MRI data. METHODS: Acute demyelination by feeding 0.2% cuprizone for five weeks, followed by a four-week remyelination period was applied on genetically modified plp-GFP mice. Animals were scanned at different time points of the demyelination and remyelination phases of the cuprizone model using a multimodal MRI protocol, including ihMT T1D-filters, MPF (Macromolecular Proton Fraction) and R1 (longitudinal relaxation rate). For histology, plp-GFP (proteolipid protein - Green Fluorescent Protein) microscopy and LFB (Luxol Fast Blue) staining were employed as references for the myelin content. Comparison of MRI with histology was performed in the medial corpus callosum (mCC) and cerebral cortex (CTX) at two brain levels whereas ROI-wise and voxel-based analyses of the MRI metrics allowed investigating in vivo the spatial extent of myelin alterations. RESULTS: IhMT high-pass T1D-filters, targeted toward long T1D components, showed significant temporal variations in the mCC consistent with the effects induced by the cuprizone toxin. In addition, the corresponding signals correlated strongly and significantly with the myelin content assessed by GFP fluorescence and LFB staining over the demyelination and the remyelination phases. The signal of the band-pass T1D-filter, which isolates short T1D components, showed changes over time that were poorly correlated with histology, hence suggesting a sensitivity to pathological processes possibly not related to myelin. Although MPF was also highly correlated to histology, ihMT high-pass T1D-filters showed better capability to characterize the spatial-temporal patterns during the demyelination and remyelination phases of the acute cuprizone model (e.g., rostro-caudal gradient of demyelination in the mCC previously described in the literature). CONCLUSIONS: IhMT sequences selective for long T1D components are specific and sensitive in vivo markers of demyelination and remyelination and have successfully captured the spatially heterogeneous pattern of the demyelination and remyelination mechanisms in the cuprizone model. Interestingly, differences in signal variations between the ihMT high-pass and band-pass T1D-filter, suggest a sensitivity of the ihMT sequences targeted to short T1Ds to alterations other than those of myelin. Future studies will need to further address these differences by examining more closely the origin of the short T1D components and the variation of each T1D component in pathology.


Assuntos
Doenças Desmielinizantes , Remielinização , Animais , Camundongos , Cuprizona/toxicidade , Doenças Desmielinizantes/induzido quimicamente , Doenças Desmielinizantes/diagnóstico por imagem , Doenças Desmielinizantes/metabolismo , Imageamento por Ressonância Magnética/métodos , Bainha de Mielina/metabolismo , Camundongos Endogâmicos C57BL , Modelos Animais de Doenças
3.
Neuroimage ; 236: 118046, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33848620

RESUMO

PURPOSE: The promise of inhomogeneous magnetization transfer (ihMT) as a new myelin imaging method was studied in ex vivo human brain tissue and in relation to myelin water fraction (MWF). The temperature dependence of both methods was characterized, as well as their correspondence with a histological measure of myelin content. Unfiltered and filtered ihMT protocols were studied by adjusting the saturation scheme to preserve or attenuate signal from tissue with short dipolar relaxation time T1D. METHODS: ihMT ratio (ihMTR) and MWF maps were acquired at 7 T from formalin-fixed human brain samples at 22.5 °C, 30 °C and 37 °C. The impact of temperature on unfiltered ihMTR, filtered ihMTR and MWF was investigated and compared to myelin basic protein staining. RESULTS: Unfiltered ihMTR exhibited no temperature dependence, whereas filtered ihMTR increased with increasing temperature. MWF decreased at higher temperature, with an increasing prevalence of areas where the myelin water signal was unreliably determined, likely related to a reduction in T2 peak separability at higher temperatures ex vivo. MWF and ihMTR showed similar per-sample correlation with myelin staining at room temperature. At 37 °C, filtered ihMTR was more strongly correlated with myelin staining and had increased dynamic range compared to unfiltered ihMTR. CONCLUSIONS: Given the temperature dependence of filtered ihMT, increased dynamic range, and strong myelin specificity that persists at higher temperatures, we recommend carefully controlled temperatures close to 37 °C for filtered ihMT acquisitions. Unfiltered ihMT may also be useful, due to its independence from temperature, higher amplitude values, and sensitivity to short T1D components. Ex vivo myelin water imaging should be performed at room temperature, to avoid fitting issues found at higher temperatures.


Assuntos
Água Corporal/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Bainha de Mielina , Neuroimagem/métodos , Substância Branca/anatomia & histologia , Substância Branca/diagnóstico por imagem , Idoso , Biomarcadores , Feminino , Formaldeído , Humanos , Temperatura , Fixação de Tecidos
4.
Magn Reson Med ; 79(5): 2607-2619, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28940355

RESUMO

PURPOSE: To implement, characterize, and optimize an interleaved inhomogeneous magnetization transfer (ihMT) gradient echo sequence allowing for whole-brain imaging within a clinically compatible scan time. THEORY AND METHODS: A general framework for ihMT modelling was developed based on the Provotorov theory of radiofrequency saturation, which accounts for the dipolar order underpinning the ihMT effect. Experimental studies and numerical simulations were performed to characterize and optimize the ihMT-gradient echo dependency with sequence timings, saturation power, and offset frequency. The protocol was optimized in terms of maximum signal intensity and the reproducibility assessed for a nominal resolution of 1.5 mm isotropic. All experiments were performed on healthy volunteers at 1.5T. RESULTS: An important mechanism driving signal optimization and leading to strong ihMT signal enhancement that relies on the dynamics of radiofrequency energy deposition has been identified. By taking advantage of the delay allowed for readout between ihMT pulse bursts, it was possible to boost the ihMT signal by almost 2-fold compared to previous implementation. Reproducibility of the optimal protocol was very good, with an intra-individual error < 2%. CONCLUSION: The proposed sensitivity-boosted and time-efficient steady-state ihMT-gradient echo sequence, implemented and optimized at 1.5T, allowed robust high-resolution 3D ihMT imaging of the whole brain within a clinically compatible scan time. Magn Reson Med 79:2607-2619, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Encéfalo/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Simulação por Computador , Feminino , Análise de Fourier , Humanos , Masculino , Adulto Jovem
5.
Magn Reson Med ; 78(4): 1362-1372, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-27859618

RESUMO

PURPOSE: This paper describes a technique that can be used in vivo to measure the dipolar relaxation time, T1D , of macromolecular protons contributing to magnetization transfer (MT) in tissues and to produce quantitative T1D maps. THEORY AND METHODS: The technique builds upon the inhomogeneous MT (ihMT) technique that is particularly sensitive to tissue components with long T1D . A standard ihMT experiment was altered to introduce a variable time for switching between positive and negative offset frequencies for RF saturation. A model for the dependence of ihMT was developed and used to fit data acquired in vivo. RESULTS: Application of the method to images from brains of healthy volunteers produced values of T1D = (5.9 ± 1.2) ms in gray matter and T1D = (6.2 ± 0.4) ms in white matter regions and provided maps of the T1D parameter. CONCLUSION: The model and experiments described provide access to a new relaxation characteristic of tissue with potentially unique diagnostic information. Magn Reson Med 78:1362-1372, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Mapeamento Encefálico/métodos , Substância Cinzenta/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Humanos , Bainha de Mielina/química , Imagens de Fantasmas , Adulto Jovem
6.
Magn Reson Med ; 77(2): 581-591, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-26959278

RESUMO

PURPOSE: Inhomogeneous magnetization transfer (ihMT) shows great promise for specific imaging of myelinated tissues. Whereas the ihMT technique has been previously applied in brain applications, the current report presents a strategy for cervical spinal cord (SC) imaging free of cerebrospinal fluid (CSF) pulsatility artifacts. METHODS: A pulsed ihMT preparation was combined with a single-shot HASTE readout. Electrocardiogram (ECG) synchronization was used to acquire all images during the quiescent phase of SC motion. However ihMT signal quantification errors may occur when a variable recovery delay is introduced in the sequence as a consequence of variable cardiac cycle. A semiautomatic retrospective correction algorithm, based on repetition time (TR) -matching, is proposed to correct for signal variations of long T1 -components (e.g., CSF). RESULTS: The proposed strategy combining ECG synchronization and retrospective data pairing led to clean SC images free of CSF artifacts. Lower variability of the ihMT metrics were obtained with the correction algorithm, and allowed for shorter TR to be used, hence improving signal-to-noise ratio efficiency. CONCLUSION: The proposed methodology enabled faster acquisitions, while offering robust ihMT quantification and exquisite SC image quality. This opens great perspectives for widening the in vivo characterization of SC physiopathology using MRI, such as studying white matter tracts microstructure or impairment in degenerative pathologies. Magn Reson Med 77:581-591, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Algoritmos , Artefatos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Líquido Cefalorraquidiano/citologia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Medula Espinal/anatomia & histologia , Adulto , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Movimento (Física) , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
MAGMA ; 29(4): 699-709, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26762244

RESUMO

OBJECTIVES: The recently reported inhomogeneous magnetization transfer technique (ihMT) has been proposed for specific imaging of inhomogeneously broadened lines, and has shown great promise for characterizing myelinated tissues. The ihMT contrast is obtained by subtracting magnetization transfer images obtained with simultaneous saturation at positive and negative frequency offsets (dual frequency saturation experiment, MT (+/-)) from those obtained with single frequency saturation (MT (+)) at the same total power. Hence, ihMT may be biased by MT-asymmetry, especially at ultra-high magnetic field. Use of the average of single positive and negative frequency offset saturation MT images, i.e., (MT (+)+MT (-)) has been proposed to correct the ihMT signal from MT-asymmetry signal. MATERIALS AND METHODS: The efficiency of this correction method was experimentally assessed in this study, performed at 11.75 T on mice. Quantitative corrected ihMT and MT-asymmetry ratios (ihMTR and MTRasym) were measured in mouse brain structures for several MT-asymmetry magnitudes and different saturation parameter sets. RESULTS: Our results indicated a "safe" range of magnitudes (/MTRasym/<4 %) for which MT-asymmetry signal did not bias the corrected ihMT signal. Moreover, experimental evidence of the different natures of both MT-asymmetry and inhomogeneous MT contrasts were provided. In particular, non-zero ihMT ratios were obtained at zero MTRasym values. CONCLUSION: MTRasym is not a confounding factor for ihMT quantification, even at ultra-high field, as long as MTRasym is restricted to ±4 %.


Assuntos
Campos Magnéticos , Imageamento por Ressonância Magnética , Magnetismo , Bainha de Mielina/química , Algoritmos , Animais , Encéfalo/diagnóstico por imagem , Feminino , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Camundongos , Camundongos Endogâmicos C57BL
8.
Magn Reson Med ; 73(6): 2111-21, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24962257

RESUMO

PURPOSE: Recently a new MR endogenous contrast mechanism was reported. It allows specifically imaging the magnetization transfer (MT) effect arising from inhomogeneously broadened components of the NMR spectrum, and was hence dubbed ihMT. Such unique NMR lineshape properties are presumably occurring in myelin because of its specifically ordered, multilayered sheath structure. Here, optimization of a pulsed ihMT preparation module is presented to provide guidance for future studies and improve the understanding of underlying contrast mechanisms. METHODS: This study was performed at 1.5 Tesla on healthy volunteers. A pulsed ihMT preparation was implemented in combination with a HASTE readout module. The pulse width, interpulse repetition time, total saturation duration and RF saturation power were considered for optimization of the ihMT sensitivity and contrast. RESULTS: An optimal configuration of the preparation module was derived, leading to 10% ihMT signal in internal capsule (relative to unsaturated data) and around 200% signal increase relative to gray matter, i.e., approximately 10-fold superior contrast compared with conventional MT ratios, measured under similar experimental conditions. CONCLUSION: Overall the ihMT sequence was robust, sensitive and very specific for white matter. These findings suggest great potential for assessing brain myelination and for better characterization of myelin related disorders.


Assuntos
Mapeamento Encefálico/métodos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Substância Branca/anatomia & histologia , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador/métodos , Sensibilidade e Especificidade
9.
J Magn Reson Imaging ; 42(4): 999-1008, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25712197

RESUMO

BACKGROUND: To derive an adapted protocol at ultra high magnetic field for mouse kidney perfusion measurements using pCASL in combination with three widely available fast imaging readouts: segmented SE EPI (sSE EPI), RARE, and TrueFISP. METHODS: pCASL sSE EPI, pCASL RARE, and pCASL TrueFISP were used for the acquisition of mouse kidney perfusion images in the axial and coronal planes at 11.75T. Results were compared in terms of perfusion sensitivity, signal-to-noise ratio (SNR), blood flow values, intrasession and intersession repeatability, and image quality (subjectively classified into three grades: good, satisfactory, and unacceptable). RESULTS: Renal cortex perfusion measurements were performed within 2 min with pCASL RARE/pCASL TrueFISP and 4 min with pCASL sSE EPI. In an axial direction, SNR values of 6.6/5.6/2.8, perfusion sensitivity values of 16.1 ± 3.7/13.6 ± 2.4/13.4 ± 1.0 %, blood flow values of 679 ± 149/466 ± 111/572 ± 46 mL/100 g/min and in-ROI variations values of 192/161/181 mL/100 g/min were obtained with pCASL sSE EPI/pCASL RARE/pCASL TrueFISP. Highest SNR per unit of time (1.8) and highest intra/intersession reliability (92.9% and 95.1%) were obtained with pCASL RARE, which additionally presented highly reproducible satisfactory image quality. In coronal plane, significantly lower SNR, perfusion sensitivity and perfusion values were obtained for all techniques compared with that in the axial plane (P < 0.05) due to magnetization saturation effects. CONCLUSION: pCASL RARE demonstrated more advantages for longitudinal preclinical kidney perfusion studies at ultra high magnetic field.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Rim/fisiologia , Angiografia por Ressonância Magnética/métodos , Artéria Renal/fisiologia , Circulação Renal/fisiologia , Animais , Sistemas Computacionais , Feminino , Aumento da Imagem/métodos , Rim/irrigação sanguínea , Campos Magnéticos , Camundongos , Camundongos Endogâmicos C57BL , Artéria Renal/anatomia & histologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa