Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Molecules ; 28(4)2023 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-36838750

RESUMO

The increasing interest in stretchable conductive composite materials, that can be versatile and suitable for wide-ranging application, has sparked a growing demand for studies of scalable fabrication techniques and specifically tailored geometries. Thanks to the combination of the conductivity and robustness of carbon nanotube (CNT) materials with the viscoelastic properties of polymer films, in particular their stretchability, "surface composites" made of a CNT on polymeric films are a promising way to obtain a low-cost, conductive, elastic, moldable, and patternable material. The use of polymers selected for specific applications, however, requires targeted studies to deeply understand the interface interactions between a CNT and the surface of such polymer films, and in particular the stability and durability of a CNT grafting onto the polymer itself. Here, we present an investigation of the interface properties for a selected group of polymer film substrates with different viscoelastic properties by means of a series of different and complementary experimental techniques. Specifically, we studied the interaction of a single-wall carbon nanotube (SWCNT) deposited on two couples of different polymeric substrates, each one chosen as representative of thermoplastic polymers (i.e., low-density polyethylene (LDPE) and polypropylene (PP)) and thermosetting elastomers (i.e., polyisoprene (PI) and polydimethylsiloxane (PDMS)), respectively. Our results demonstrate that the characteristics of the interface significantly differ for the two classes of polymers with a deeper penetration (up to about 100 µm) into the polymer bulk for the thermosetting substrates. Consequently, the resistance per unit length varies in different ranges, from 1-10 kΩ/cm for typical thermoplastic composite devices (30 µm thick and 2 mm wide) to 0.5-3 MΩ/cm for typical thermosetting elastomer devices (150 µm thick and 2 mm wide). For these reasons, the composites show the different mechanical and electrical responses, therefore suggesting different areas of application of the devices based on such materials.


Assuntos
Nanotubos de Carbono , Dispositivos Eletrônicos Vestíveis , Polímeros/química , Nanotubos de Carbono/química , Elastômeros/química , Transdutores
2.
J Chem Phys ; 157(9): 094501, 2022 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-36075726

RESUMO

We present an experimental investigation of methylammonium lead tribromide single crystals in the orthorhombic, tetragonal, and cubic phases based on inelastic and deep inelastic neutron scattering experiments. We show how the average hydrogen nuclear kinetic energy, mainly affected by zero-point vibrational energies, shows differences larger compared to the changes simply related to temperature effects when moving from one phase to another. In particular, the Gaussian contribution to the average nuclear kinetic energy is larger in the tetragonal phase compared to the cubic and orthorhombic ones. Moreover, we find that the vibrational densities of states of MAPbBr3 single crystals in the orthorhombic phase are compatible with previously reported results on powder samples, and that the only vibrational modes that show slightly different frequencies compared to MAPbI3 are those in the energy range between 100 and 300 cm-1, related to librational/rotational modes. As these shifts are of about 10 cm-1 and do not affect any higher-energy vibrational mode, we conclude that the zero-point energies and average nuclear kinetic energies in the two-hybrid organic/inorganic perovskites are expected to be approximately the same within a harmonic framework.

3.
Int J Mol Sci ; 20(17)2019 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-31450543

RESUMO

Aggregation states of amyloid beta peptides for amyloid beta A ß 1 - 40 to A ß 1 - 42 and A ß p 3 - 42 are investigated through small angle neutron scattering (SANS). The knowledge of these small peptides and their aggregation state are of key importance for the comprehension of neurodegenerative diseases (e.g., Alzheimer's disease). The SANS technique allows to study the size and fractal nature of the monomers, oligomers and fibrils of the three different peptides. Results show that all the investigated peptides have monomers with a radius of gyration of the order of 10 Å, while the oligomers and fibrils display differences in size and aggregation ability, with A ß p 3 - 42 showing larger oligomers. These properties are strictly related to the toxicity of the corresponding amyloid peptide and indeed to the development of the associated disease.


Assuntos
Peptídeos beta-Amiloides/química , Amiloide/química , Agregados Proteicos , Fragmentos de Peptídeos/química , Agregação Patológica de Proteínas , Ligação Proteica , Conformação Proteica , Multimerização Proteica , Análise Espectral
4.
Med Phys ; 51(1): 439-446, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37956252

RESUMO

BACKGROUND: Boron-containing compounds, such as 4-borono-phenylalanine (BPA) are used as drugs for cancer treatment in the framework of Boron Neutron Capture Therapy (BNCT). Neutron irradiation of boron-rich compounds delivered to cancer cells triggers nuclear reactions that destroy cancer cells. PURPOSE: We provide a modeling of the thermal neutron cross section of BPA, a drug used in Boron Neutron Capture Therapy (BNCT), to quantify the competing contributions of boron absorption against hydrogen scattering, for optimizing BNCT by minimizing the latter. METHODS: We perform the experimental determination of the total neutron scattering cross section of BPA at thermal and epithermal neutron energies using neutron transmission measurements. We isolate the contribution related to the incoherent scattering by hydrogen atoms as a function of the neutron energy by means of the Average Functional Group Approximation, and we calculate the probability for a neutron of being absorbed as a function of the neutron energy both for BPA and for its variants where either one or all four aromatic hydrogen atoms are substituted by 19 F, and both for the samples with natural occurrence or enriched concentration of 10 B. RESULTS: While referring to the already available literature for in vivo use of fluorinated BPA, we show that fluorine-rich variants of BPA increase the probability of neutrons being captured by the molecule. As the higher absorption efficiency of fluorinated BPA does not depend on whether the molecule is used in vivo or not, our results are promising for the higher efficiency of the boron neutron capture treatment. CONCLUSIONS: Our results suggest a new advantage using fluorinated compounds for BNCT, in their optimized interaction with neutrons, in addition to their already known capability to be used for monitoring and pharmacokinetics studies using 19 F-Nuclear Magnetic Resonance or in 18 F-Positron Emission Tomography.


Assuntos
Terapia por Captura de Nêutron de Boro , Boro , Terapia por Captura de Nêutron de Boro/métodos , Fenilalanina/farmacocinética , Fenilalanina/uso terapêutico , Tomografia Computadorizada por Raios X , Nêutrons , Compostos de Boro/uso terapêutico , Compostos de Boro/farmacocinética
5.
Antioxidants (Basel) ; 10(5)2021 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-33922163

RESUMO

Extra virgin olive oil (EVOO) is defined as a functional food as it contains numerous phenolic components with well-recognized health-beneficial properties, such as high antioxidant and anti-inflammatory capacity. These characteristics depend on their structural/conformational behavior, which is largely determined by intra- and intermolecular H-bond interactions. While the vibrational dynamics of isolated compounds have been studied in a number of recent investigations, their signal in a real-life sample of EVOO is overwhelmed by the major constituent acids. Here, we provide a full characterization of the vibrational spectroscopic signal from commercially available EVOO samples using Inelastic Neutron Scattering (INS) and Raman spectroscopies. The spectra are dominated by CH2 vibrations, especially at about 750 cm-1 and 1300 cm-1. By comparison with the spectra from hydroxytyrosol and other minor phenolic compounds, we show that the best regions in which to look for the structure-activity information related to the minor polar compounds is at 675 and 1200 cm-1 for hydroxytyrosol, and around 450 cm-1 for all minor polar compounds used as reference, especially if a selectively deuterated sample is available. The regional origin of the EVOO samples investigated appears to be related to the different amount of phenolic esters versus acids as reflected by the relative intensities of the peaks at 1655 and 1747 cm-1.

6.
J Chem Theory Comput ; 16(12): 7671-7680, 2020 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-33198462

RESUMO

This paper presents a Python-based algorithm, named INSCorNorm, to correct the inelastic neutron scattering (INS) spectra for both sample and container self-shielding and to normalize the experimental spectral intensity to an absolute physical scale (barn/energy unit) facilitating the comparison with computer simulations and interpretation. The algorithm is benchmarked against INS measurements of ZrH2 performed on the TOSCA spectrometer at the ISIS Facility. We also apply the algorithm to the INS spectra from l-lysine, a system of broad interest in biology and medicine, and we discuss how corrected INS data provide an experimental benchmark for theoretical calculations of nuclear anisotropic displacement parameters in molecular systems. The total neutron sample cross section to use for the self-shielding corrections is discussed, as well as the best approach to derive experimentally the cross section at the VESUVIO spectrometer, together with the experimental value of the hydrogen nuclear mean kinetic energy, ⟨Ek⟩. The algorithm is made available to the neutron user community within the MANTID software.

7.
Phys Med Biol ; 64(4): 04NT06, 2019 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-30625450

RESUMO

Magnetic resonance imaging is effective for non-invasive detection of myocardial diseases by extracellular volume fraction (ECV) estimation. A new methodology for T1 and ECV mapping is tested in this work, comparing results with other well-consolidated methods. The associated level of uncertainty for data was also estimated, to assess the reliability of the technique. A phantom with known T1 values was used for reference, and 60 subjects (40 controls, 20 diseased patients) were examined, using the modified look-locker inversion-recovery (MOLLI) method. Obtained T1 data were studied in terms of accuracy (difference with reference T1), paired comparisons with other methods, and Gamma-tool analysis with tolerances criteria of 4.21 mm for distance-to-agreement, and between 2%-5% for T1 difference. Accuracy and precision of the T1 mapping was analysed by phantom measurements, and the uncertainty of the ECV was estimated by T1 error propagation. Differences (in paired comparisons) of T1 datasets were not significant neither for statistical tests, nor for Bland-Altman analysis. T1 accuracy was between -12% and -1% across methods, slightly better for the tested method (mean accuracy in the T1 range of interest better than 2%). The Gamma analysis confirm slightly better results for the tested method than other methodologies. The new method improves the computational efficiency by a factor of 25 (at least), revealing to be also more suitable for Big Data-related applications.


Assuntos
Algoritmos , Doenças Cardiovasculares/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/normas , Miocárdio/patologia , Imagens de Fantasmas , Estudos de Casos e Controles , Humanos , Reprodutibilidade dos Testes
8.
Phys Med Biol ; 63(3): 035008, 2018 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-29256434

RESUMO

Dynamic contrast-enhanced cardiovascular magnetic resonance imaging can be used to quantitatively assess the myocardial blood flow (MBF), recovering the tissue impulse response function for the transit of a gadolinium bolus through the myocardium. Several deconvolution techniques are available, using various models for the impulse response. The method of choice may influence the results, producing differences that have not been deeply investigated yet. Three methods for quantifying myocardial perfusion have been compared: Fermi function modelling (FFM), the Tofts model (TM) and the gamma function model (GF), with the latter traditionally used in brain perfusion MRI. Thirty human subjects were studied at rest as well as under cold pressor test stress (submerging hands in ice-cold water), and a single bolus of gadolinium weighing 0.1 ± 0.05 mmol kg-1 was injected. Perfusion estimate differences between the methods were analysed by paired comparisons with Student's t-test, linear regression analysis, and Bland-Altman plots, as well as also using the two-way ANOVA, considering the MBF values of all patients grouped according to two categories: calculation method and rest/stress conditions. Perfusion estimates obtained by various methods in both rest and stress conditions were not significantly different, and were in good agreement with the literature. The results obtained during the first-pass transit time (20 s) yielded p-values in the range 0.20-0.28 for Student's t-test, linear regression analysis slopes between 0.98-1.03, and R values between 0.92-1.01. From the Bland-Altman plots, the paired comparisons yielded a bias (and a 95% CI)-expressed as ml/min/g-for FFM versus TM, -0.01 (-0.20, 0.17) or 0.02 (-0.49, 0.52) at rest or under stress respectively, for FFM versus GF, -0.05 (-0.29, 0.20) or -0.07 (-0.55, 0.41) at rest or under stress, and for TM versus GF, -0.03 (-0.30, 0.24) or -0.09 (-0.43, 0.26) at rest or under stress. With the two-way ANOVA, the results were p = 0.20 for the method effect (not significant), p < 0.0001 for the rest/stress condition effect (highly significant, as expected), whereas no interaction resulted between the rest/stress condition and method (p = 0.70, not significant). Considering a wider time-frame (60 s), the estimates for both rest and stress conditions were 25%-30% higher (p in the range 0.016-0.025) than those obtained in the 20 s time-frame. MBF estimates obtained by various methods under rest/stress conditions were not significantly different in the first-pass transit time, encouraging quantitative perfusion estimates in DCE-CMRI with the used methods.


Assuntos
Meios de Contraste , Circulação Coronária , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Miocárdio/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/metabolismo , Perfusão
9.
Eur Psychiatry ; 50: 21-27, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29398564

RESUMO

We present the first results of the MINDVIEW project. An innovative imaging system for the human brain examination, allowing simultaneous acquisition of PET/MRI images, has been designed and constructed. It consists of a high sensitivity and high resolution PET scanner integrated in a novel, head-dedicated, radio frequency coil for a 3T MRI scanner. Preliminary measurements from the PET scanner show sensitivity 3 times higher than state-of-the-art PET systems that will allow safe repeated studies on the same patient. The achieved spatial resolution, close to 1 mm, will enable differentiation of relevant brain structures for schizophrenia. A cost-effective and simple method of radiopharmaceutical production from 11C-carbon monoxide and a mini-clean room has been demonstrated. It has been shown that 11C-raclopride has higher binding potential in a new VAAT null mutant mouse model of schizophrenia compared to wild type control animals. A significant reduction in TSPO binding has been found in gray matter in a small sample of drug-naïve, first episode psychosis patients, suggesting a reduced number or an altered function of immune cells in brain at early stage schizophrenia.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Transtornos Psicóticos/diagnóstico por imagem , Esquizofrenia/diagnóstico por imagem , Substância Cinzenta/diagnóstico por imagem , Humanos , Imagem Multimodal/métodos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa