Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
J Digit Imaging ; 32(1): 6-18, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30076490

RESUMO

In today's radiology workflow, free-text reporting is established as the most common medium to capture, store, and communicate clinical information. Radiologists routinely refer to prior radiology reports of a patient to recall critical information for new diagnosis, which is quite tedious, time consuming, and prone to human error. Automatic structuring of report content is desired to facilitate such inquiry of information. In this work, we propose an unsupervised machine learning approach to automatically structure radiology reports by detecting and normalizing anatomical phrases based on the Systematized Nomenclature of Medicine-Clinical Terms (SNOMED CT) ontology. The proposed approach combines word embedding-based semantic learning with ontology-based concept mapping to derive the desired concept normalization. The word embedding model was trained using a large corpus of unlabeled radiology reports. Fifty-six anatomical labels were extracted from SNOMED CT as class labels of the whole human anatomy. The proposed framework was compared against a number of state-of-the-art supervised and unsupervised approaches. Radiology reports from three different clinical sites were manually labeled for testing. The proposed approach outperformed other techniques yielding an average precision of 82.6%. The proposed framework boosts the coverage and performance of conventional approaches for concept normalization, by applying word embedding techniques in semantic learning, while avoiding the challenge of having access to a large amount of annotated data, which is typically required for training classifiers.


Assuntos
Registros Eletrônicos de Saúde , Radiologia/métodos , Terminologia como Assunto , Aprendizado de Máquina não Supervisionado , Humanos , Fluxo de Trabalho
2.
AJR Am J Roentgenol ; 208(3): 585-594, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28095022

RESUMO

OBJECTIVE: The purpose of this study is to determine the conversion factors that enable accurate estimation of the effective dose (ED) used for cardiac 64-MDCT angiography performed for children. MATERIALS AND METHODS: Anthropomorphic phantoms representative of 1- and 10-year-old children, with 50 metal oxide semiconductor field-effect transistor dosimeters placed in organs, underwent scanning performed using a 64-MDCT scanner with different routine clinical cardiac scan modes and x-ray tube potentials. Organ doses were used to calculate the ED on the basis of weighting factors published in 1991 in International Commission on Radiological Protection (ICRP) publication 60 and in 2007 in ICRP publication 103. The EDs and the scanner-reported dose-length products were used to determine conversion factors for each scan mode. The effect of infant heart rate on the ED and the conversion factors was also assessed. RESULTS: The mean conversion factors calculated using the current definition of ED that appeared in ICRP publication 103 were as follows: 0.099 mSv · mGy-1 · cm-1, for the 1-year-old phantom, and 0.049 mSv · mGy-1 · cm-1, for the 10-year-old phantom. These conversion factors were a mean of 37% higher than the corresponding conversion factors calculated using the older definition of ED that appeared in ICRP publication 60. Varying the heart rate did not influence the ED or the conversion factors. CONCLUSION: Conversion factors determined using the definition of ED in ICRP publication 103 and cardiac, rather than chest, scan coverage suggest that the radiation doses that children receive from cardiac CT performed using a contemporary 64-MDCT scanner are higher than the radiation doses previously reported when older chest conversion factors were used. Additional up-to-date pediatric cardiac CT conversion factors are required for use with other contemporary CT scanners and patients of different age ranges.


Assuntos
Algoritmos , Angiografia por Tomografia Computadorizada/instrumentação , Modelos Biológicos , Tomografia Computadorizada Multidetectores/instrumentação , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Criança , Angiografia por Tomografia Computadorizada/métodos , Simulação por Computador , Feminino , Humanos , Lactente , Masculino , Tomografia Computadorizada Multidetectores/métodos , Imagens de Fantasmas , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
JCO Clin Cancer Inform ; 8: e2300186, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38753347

RESUMO

PURPOSE: Real-world evidence (RWE)-derived from analysis of real-world data (RWD)-has the potential to guide personalized treatment decisions. However, because of potential confounding, generating valid RWE is challenging. This study demonstrates how to responsibly generate RWE for treatment decisions. We validate our approach by demonstrating that we can uncover an existing adjuvant chemotherapy (ACT) guideline for stage II and III colon cancer (CC)-which came about using both data from randomized controlled trials and expert consensus-solely using RWD. METHODS: Data from the population-based Netherlands Cancer Registry from a total of 27,056 patients with stage II and III CC who underwent curative surgery were analyzed to estimate the overall survival (OS) benefit of ACT. Focusing on 5-year OS, the benefit of ACT was estimated for each patient using G-computation methods by adjusting for patient and tumor characteristics and estimated propensity score. Subsequently, on the basis of these estimates, an ACT decision tree was constructed. RESULTS: The constructed decision tree corresponds to the current Dutch guideline: patients with stage III or stage II with T stage 4 should receive surgery and ACT, whereas patients with stage II with T stage 3 should only receive surgery. Interestingly, we do not find sufficient RWE to conclude against ACT for stage II with T stage 4 and microsatellite instability-high (MSI-H), a recent addition to the current guideline. CONCLUSION: RWE, if used carefully, can provide a valuable addition to our construction of evidence on clinical decision making and therefore ultimately affect treatment guidelines. Next to validating the ACT decisions advised in the current Dutch guideline, this paper suggests additional attention should be paid to MSI-H in future iterations of the guideline.


Assuntos
Neoplasias do Colo , Estadiamento de Neoplasias , Humanos , Neoplasias do Colo/patologia , Neoplasias do Colo/tratamento farmacológico , Neoplasias do Colo/terapia , Neoplasias do Colo/mortalidade , Feminino , Países Baixos/epidemiologia , Masculino , Idoso , Pessoa de Meia-Idade , Quimioterapia Adjuvante/métodos , Sistema de Registros , Tomada de Decisão Clínica , Seleção de Pacientes
4.
Eur Urol Open Sci ; 63: 81-88, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38572301

RESUMO

Combination therapies in metastatic hormone-sensitive prostate cancer (mHSPC), which include the addition of an androgen receptor signaling inhibitor and/or docetaxel to androgen deprivation therapy, have been a game changer in the management of this disease stage. However, these therapies come with their fair share of toxicities and side effects. The goal of this observational study is to report drug-related adverse events (AEs), which are correlated with systemic combination therapies for mHSPC. Determining the optimal treatment option requires large cohorts to estimate the tolerability and AEs of these combination therapies in "real-life" patients with mHSPC, as provided in this study. We use a network of databases that includes population-based registries, electronic health records, and insurance claims, containing the overall target population and subgroups of patients defined by unique certain characteristics, demographics, and comorbidities, to compute the incidence of common AEs associated with systemic therapies in the setting of mHSPC. These data sources are standardised using the Observational Medical Outcomes Partnership Common Data Model. We perform the descriptive statistics as well as calculate the AE incidence rate separately for each treatment group, stratified by age groups and index year. The time until the first event is estimated using the Kaplan-Meier method within each age group. In the case of episodic events, the anticipated mean cumulative counts of events are calculated. Our study will allow clinicians to tailor optimal therapies for mHSPC patients, and they will serve as a basis for comparative method studies.

5.
Eur Urol ; 85(5): 457-465, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37414703

RESUMO

BACKGROUND: Conservative management is an option for prostate cancer (PCa) patients either with the objective of delaying or even avoiding curative therapy, or to wait until palliative treatment is needed. PIONEER, funded by the European Commission Innovative Medicines Initiative, aims at improving PCa care across Europe through the application of big data analytics. OBJECTIVE: To describe the clinical characteristics and long-term outcomes of PCa patients on conservative management by using an international large network of real-world data. DESIGN, SETTING, AND PARTICIPANTS: From an initial cohort of >100 000 000 adult individuals included in eight databases evaluated during a virtual study-a-thon hosted by PIONEER, we identified newly diagnosed PCa cases (n = 527 311). Among those, we selected patients who did not receive curative or palliative treatment within 6 mo from diagnosis (n = 123 146). OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Patient and disease characteristics were reported. The number of patients who experienced the main study outcomes was quantified for each stratum and the overall cohort. Kaplan-Meier analyses were used to estimate the distribution of time to event data. RESULTS AND LIMITATIONS: The most common comorbidities were hypertension (35-73%), obesity (9.2-54%), and type 2 diabetes (11-28%). The rate of PCa-related symptomatic progression ranged between 2.6% and 6.2%. Hospitalization (12-25%) and emergency department visits (10-14%) were common events during the 1st year of follow-up. The probability of being free from both palliative and curative treatments decreased during follow-up. Limitations include a lack of information on patients and disease characteristics and on treatment intent. CONCLUSIONS: Our results allow us to better understand the current landscape of patients with PCa managed with conservative treatment. PIONEER offers a unique opportunity to characterize the baseline features and outcomes of PCa patients managed conservatively using real-world data. PATIENT SUMMARY: Up to 25% of men with prostate cancer (PCa) managed conservatively experienced hospitalization and emergency department visits within the 1st year after diagnosis; 6% experienced PCa-related symptoms. The probability of receiving therapies for PCa decreased according to time elapsed after the diagnosis.


Assuntos
Diabetes Mellitus Tipo 2 , Neoplasias da Próstata , Masculino , Adulto , Humanos , Big Data , Neoplasias da Próstata/terapia , Neoplasias da Próstata/diagnóstico , Intervalo Livre de Doença , Europa (Continente)
6.
Nucleic Acids Res ; 39(1): 292-9, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20810537

RESUMO

We show on general theoretical grounds that the two ends of single-stranded (ss) RNA molecules (consisting of roughly equal proportions of A, C, G and U) are necessarily close together, largely independent of their length and sequence. This is demonstrated to be a direct consequence of two generic properties of the equilibrium secondary structures, namely that the average proportion of bases in pairs is ∼60% and that the average duplex length is ∼4. Based on mfold and Vienna computations on large numbers of ssRNAs of various lengths (1000-10 000 nt) and sequences (both random and biological), we find that the 5'-3' distance-defined as the sum of H-bond and covalent (ss) links separating the ends of the RNA chain-is small, averaging 15-20 for each set of viral sequences tested. For random sequences this distance is ∼12, consistent with the theory. We discuss the relevance of these results to evolved sequence complementarity and specific protein binding effects that are known to be important for keeping the two ends of viral and messenger RNAs in close proximity. Finally we speculate on how our conclusions imply indistinguishability in size and shape of equilibrated forms of linear and covalently circularized ssRNA molecules.


Assuntos
RNA/química , Modelos Moleculares , Conformação de Ácido Nucleico , RNA Circular , RNA Viral/química
7.
Proc Natl Acad Sci U S A ; 105(42): 16153-8, 2008 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-18845685

RESUMO

We present a theory of the dependence on sequence of the three-dimensional size of large single-stranded (ss) RNA molecules. The work is motivated by the fact that the genomes of many viruses are large ssRNA molecules-often several thousand nucleotides long-and that these RNAs are spontaneously packaged into small rigid protein shells. We argue that there has been evolutionary pressure for the genome to have overall spatial properties-including an appropriate radius of gyration, R(g)-that facilitate this assembly process. For an arbitrary RNA sequence, we introduce the (thermal) average maximum ladder distance (MLD) and use it as a measure of the "extendedness" of the RNA secondary structure. The MLD values of viral ssRNAs that package into capsids of fixed size are shown to be consistently smaller than those for randomly permuted sequences of the same length and base composition, and also smaller than those of natural ssRNAs that are not under evolutionary pressure to have a compact native form. By mapping these secondary structures onto a linear polymer model and by using MLD as a measure of effective contour length, we predict the R(g) values of viral ssRNAs are smaller than those of nonviral sequences. More generally, we predict the average MLD values of large nonviral ssRNAs scale as N(0.67+/-0.01), where N is the number of nucleotides, and that their R(g) values vary as MLD(0.5) in an ideal solvent, and hence as N(0.34). An alternative analysis, which explicitly includes all branches, is introduced and shown to yield consistent results.


Assuntos
Conformação de Ácido Nucleico , RNA/química , Sequência de Bases , Modelos Moleculares , Dados de Sequência Molecular
8.
JCO Clin Cancer Inform ; 4: 865-874, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33006906

RESUMO

PURPOSE: Literature on clinical note mining has highlighted the superiority of machine learning (ML) over hand-crafted rules. Nevertheless, most studies assume the availability of large training sets, which is rarely the case. For this reason, in the clinical setting, rules are still common. We suggest 2 methods to leverage the knowledge encoded in pre-existing rules to inform ML decisions and obtain high performance, even with scarce annotations. METHODS: We collected 501 prostate pathology reports from 6 American hospitals. Reports were split into 2,711 core segments, annotated with 20 attributes describing the histology, grade, extension, and location of tumors. The data set was split by institutions to generate a cross-institutional evaluation setting. We assessed 4 systems, namely a rule-based approach, an ML model, and 2 hybrid systems integrating the previous methods: a Rule as Feature model and a Classifier Confidence model. Several ML algorithms were tested, including logistic regression (LR), support vector machine (SVM), and eXtreme gradient boosting (XGB). RESULTS: When training on data from a single institution, LR lags behind the rules by 3.5% (F1 score: 92.2% v 95.7%). Hybrid models, instead, obtain competitive results, with Classifier Confidence outperforming the rules by +0.5% (96.2%). When a larger amount of data from multiple institutions is used, LR improves by +1.5% over the rules (97.2%), whereas hybrid systems obtain +2.2% for Rule as Feature (97.7%) and +2.6% for Classifier Confidence (98.3%). Replacing LR with SVM or XGB yielded similar performance gains. CONCLUSION: We developed methods to use pre-existing handcrafted rules to inform ML algorithms. These hybrid systems obtain better performance than either rules or ML models alone, even when training data are limited.


Assuntos
Aprendizado de Máquina , Próstata , Algoritmos , Humanos , Modelos Logísticos , Masculino , Máquina de Vetores de Suporte , Estados Unidos
9.
J Phys Chem B ; 113(12): 3873-9, 2009 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-19296704

RESUMO

We consider the force acting on a polymer part of whose length is configurationally confined in a tube and the rest of which is free. This situation arises in many different physical contexts, including a flexible synthetic polymer partially confined in a nanopore and a stiff viral genome partially ejected from its capsid. In both cases the force acting to pull the chain molecule out of its confinement is argued to be constant once a few persistence lengths are "free"/"outside". We present Brownian dynamics simulations that confirm the constancy of the force for different chain lengths and illustrate the dependence of the force on the strength of tube confinement. Experimental results are reported for genome ejection from viral capsids, from which we estimate the pulling force to be a few tenths of a piconewton.


Assuntos
Polímeros/química , Simulação por Computador , Modelos Químicos
10.
AMIA Jt Summits Transl Sci Proc ; 2019: 212-221, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31258973

RESUMO

Electronic Health Records contain a wealth of clinical information that can potentially be used for a variety of clinical tasks. Clinical narratives contain information about the existence or absence of medical conditions as well as clinical findings. It is essential to be able to distinguish between the two since the negated events and the non-negated events often have very different prognostic value. In this paper, we present a feature-enriched neural network-based model for negation scope detection in biomedical texts. The system achieves a robust high performance on two different types of texts, scientific abstracts, and radiology reports, achieving the new state-of-the-art result without requiring the availability of gold cue information for negation scope detection task on the scientific abstracts part of BioScope1 corpus and competitive result on the radiology report corpus.

11.
Healthcare (Basel) ; 7(4)2019 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-31810236

RESUMO

In prostate cancer external beam radiation therapy (EBRT), intra-fraction prostate drifts may compromise the treatment efficacy by underdosing the target and/or overdosing the organs at risk. In this study, a recently developed real-time adaptive planning strategy for intensity-modulated radiation therapy (IMRT) for prostate cancer was evaluated in hypofractionated regimes against traditional treatment planning based on a treatment volume margin expansion. The proposed workflow makes use of a "library of plans" corresponding to possible intra-fraction prostate positions. During delivery, at each beam end, the plan prepared for the position of the prostate closest to the current one is selected and the corresponding beam delivered. This adaptive planning strategy was compared with the traditional approach on a clinical prostate cancer case where different prostate shift magnitudes were considered. Five, six and fifteen fraction hypofractionated schemes were considered for each of these scenarios. When shifts larger than the treatment margin were present, using the traditional approach the seminal vesicles were underdosed by 3-4% of the prescribed dose. The adaptive approach instead allowed for correct target dose coverage and lowered the dose on the rectum for each dosimetric endpoint on average by 3-4% in all the fractionation schemes. Standard intensity-modulated radiation therapy planning did not always guarantee a correct dose distribution on the seminal vesicles and the rectum. The adaptive planning strategy proposed resulted insensitive to the intra-fraction prostate drifts, produced a dose distribution in agreement with the dosimetric requirements in every case analysed and significantly lowered the dose on the rectum.

12.
PLoS One ; 14(2): e0213002, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30818345

RESUMO

BACKGROUND AND PURPOSE: In prostate cancer treatment with external beam radiation therapy (EBRT), prostate motion and internal changes in tissue distribution can lead to a decrease in plan quality. In most currently used planning methods, the uncertainties due to prostate motion are compensated by irradiating a larger treatment volume. However, this could cause underdosage of the treatment volume and overdosage of the organs at risk (OARs). To reduce this problem, in this proof of principle study we developed and evaluated a novel adaptive planning method. The strategy proposed corrects the dose delivered by each beam according to the actual position of the target in order to produce a final dose distribution dosimetrically as similar as possible to the prescribed one. MATERIAL AND METHODS: Our adaptive planning method was tested on a phantom case and on a clinical case. For the first, a pilot study was performed on an in-silico pelvic phantom. A "library" of intensity modulated RT (IMRT) plans corresponding to possible positions of the prostate during a treatment fraction was generated at planning stage. Then a 3D random walk model was used to simulate possible displacements of the prostate during the treatment fraction. At treatment stage, at the end of each beam, based on the current position of the target, the beam from the library of plans, which could reproduce the best approximation of the prescribed dose distribution, was selected and delivered. In the clinical case, the same approach was used on two prostate cancer patients: for the first a tissue deformation was simulated in-silico and for the second a cone beam CT (CBCT) taken during the treatment was used to simulate an intra-fraction change. Then, dosimetric comparisons with the standard treatment plan and, for the second patient, also with an isocenter shift correction, were performed. RESULTS: For the phantom case, the plan generated using the adaptive planning method was able to meet all the dosimetric requirements and to correct for a misdosage of 13% of the dose prescription on the prostate. For the first clinical case, the standard planning method caused underdosage of the seminal vesicles, respectively by 5% and 4% of the prescribed dose, when the position changes for the target were correctly taken into account. The proposed adaptive planning method corrected any possible missed target coverage, reducing at the same time the dose on the OARs. For the second clinical case, both with the standard planning strategy and with the isocenter shift correction target coverage was significantly worsened (in particular uniformity) and some organs exceeded some toxicity objectives. While with our approach, the most uniform coverage for the target was produced and systematically the lowest toxicity values for the organs at risk were achieved. CONCLUSIONS: In our proof of principle study, the adaptive planning method performed better than the standard planning and the isocenter shift methods for prostate EBRT. It improved the coverage of the treatment volumes and lowered the dose to the OARs. This planning method is particularly promising for hypofractionated IMRT treatments in which a higher precision and control on dose deposition are needed. Further studies will be performed to test more extensively the proposed adaptive planning method and to evaluate it at a full clinical level.


Assuntos
Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Simulação por Computador , Sistemas Computacionais , Tomografia Computadorizada de Feixe Cônico , Humanos , Masculino , Movimento (Física) , Órgãos em Risco , Imagens de Fantasmas , Estudo de Prova de Conceito , Próstata/diagnóstico por imagem , Próstata/patologia , Próstata/efeitos da radiação , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/estatística & dados numéricos , Radioterapia de Intensidade Modulada/métodos , Radioterapia de Intensidade Modulada/estatística & dados numéricos
13.
Med Phys ; 46(11): 5216-5226, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31442300

RESUMO

PURPOSE: Accurate, patient-specific radiation dosimetry for CT scanning is critical to optimize radiation doses and balance dose against image quality. While Monte Carlo (MC) simulation is often used to estimate doses from CT, comparison of estimates to experimentally measured values is lacking for advanced CT scanners incorporating novel design features. We aimed to compare radiation dose estimates from MC simulation to doses measured in physical anthropomorphic phantoms using metal-oxide semiconductor field-effect transistors (MOSFETs) in a 256-slice CT scanner. METHODS: Fifty MOSFETs were placed in organs within tissue-equivalent anthropomorphic adult and pediatric radiographic phantoms, which were scanned using a variety of chest, cardiac, abdomen, brain, and whole-body protocols on a 256-slice system. MC computations were performed on voxelized CT reconstructions of the phantoms using a highly parallel MC tool developed specifically for diagnostic X-ray energies and rapid computation. Doses were compared between MC estimates and physical measurements. RESULTS: The average ratio of MOSFET to MC dose in the in-field region was close to 1 (range, 0.96-1.12; mean ± SD, 1.01 ± 0.04), indicating outstanding agreement between measured and simulated doses. The difference between measured and simulated doses tended to increase with distance from the in-field region. The error in the MC simulations due to the limited number of simulated photons was less than 1%. The errors in the MOSFET dose determinations in the in-field region for a single scan were mainly due to the calibration method and were typically about 6% (8% if the error in the reading of the ionization chamber that was used for the MOSFET calibration was included). CONCLUSIONS: Radiation dose estimation using a highly parallelized MC method is strongly correlated with experimental measurements in physical adult and infant anthropomorphic phantoms for a wide range of scans performed on a 256-slice CT scanner. Incorporation into CT scanners of radiation-dose distribution estimation, employing the scanner's reconstructed images of the patient, may offer the potential for accurate patient-specific CT dosimetry.


Assuntos
Metais/química , Método de Monte Carlo , Óxidos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/instrumentação , Transistores Eletrônicos , Adulto , Calibragem , Humanos , Radiometria , Imagem Corporal Total
14.
Med Phys ; 44(12): 6589-6602, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28940306

RESUMO

PURPOSE: Metal-oxide-semiconductor field-effect transistors (MOSFETs) serve as a helpful tool for organ radiation dosimetry and their use has grown in computed tomography (CT). While different approaches have been used for MOSFET calibration, those using the commonly available 100 mm pencil ionization chamber have not incorporated measurements performed throughout its length, and moreover, no previous work has rigorously evaluated the multiple sources of error involved in MOSFET calibration. In this paper, we propose a new MOSFET calibration approach to translate MOSFET voltage measurements into absorbed dose from CT, based on serial measurements performed throughout the length of a 100-mm ionization chamber, and perform an analysis of the errors of MOSFET voltage measurements and four sources of error in calibration. METHODS: MOSFET calibration was performed at two sites, to determine single calibration factors for tube potentials of 80, 100, and 120 kVp, using a 100-mm-long pencil ion chamber and a cylindrical computed tomography dose index (CTDI) phantom of 32 cm diameter. The dose profile along the 100-mm ion chamber axis was sampled in 5 mm intervals by nine MOSFETs in the nine holes of the CTDI phantom. Variance of the absorbed dose was modeled as a sum of the MOSFET voltage measurement variance and the calibration factor variance, the latter being comprised of three main subcomponents: ionization chamber reading variance, MOSFET-to-MOSFET variation and a contribution related to the fact that the average calibration factor of a few MOSFETs was used as an estimate for the average value of all MOSFETs. MOSFET voltage measurement error was estimated based on sets of repeated measurements. The calibration factor overall voltage measurement error was calculated from the above analysis. RESULTS: Calibration factors determined were close to those reported in the literature and by the manufacturer (~3 mV/mGy), ranging from 2.87 to 3.13 mV/mGy. The error σV of a MOSFET voltage measurement was shown to be proportional to the square root of the voltage V: σV=cV where c = 0.11 mV. A main contributor to the error in the calibration factor was the ionization chamber reading error with 5% error. The usage of a single calibration factor for all MOSFETs introduced an additional error of about 5-7%, depending on the number of MOSFETs that were used to determine the single calibration factor. The expected overall error in a high-dose region (~30 mGy) was estimated to be about 8%, compared to 6% when an individual MOSFET calibration was performed. For a low-dose region (~3 mGy), these values were 13% and 12%. CONCLUSIONS: A MOSFET calibration method was developed using a 100-mm pencil ion chamber and a CTDI phantom, accompanied by an absorbed dose error analysis reflecting multiple sources of measurement error. When using a single calibration factor, per tube potential, for different MOSFETs, only a small error was introduced into absorbed dose determinations, thus supporting the use of a single calibration factor for experiments involving many MOSFETs, such as those required to accurately estimate radiation effective dose.


Assuntos
Metais/química , Óxidos/química , Radiometria/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Transistores Eletrônicos , Calibragem , Projetos de Pesquisa
15.
J Phys Condens Matter ; 27(6): 064104, 2015 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-25564291

RESUMO

Fluorescence resonance energy transfer (FRET) measurements allow one to observe site exposure in nucleosomes, i.e. the transient unwrapping of a part of the wrapped DNA from the histone octamer. In such experiments one can typically distinguish between a closed state and an open state but in principle one might hope to detect several states, each corresponding to a certain number of open binding sites. Here we show that even in an ideal FRET setup it would be hard to detect unwrapping states with intermediate levels of FRET efficiencies. As the unwrapped DNA molecule, modelled here as a wormlike chain, has a finite stiffness, shape fluctuations smear out FRET signals completely from such intermediate states.


Assuntos
DNA/química , Transferência Ressonante de Energia de Fluorescência , Nucleossomos/química , DNA/metabolismo , Conformação de Ácido Nucleico , Nucleossomos/metabolismo
16.
Phys Rev E Stat Nonlin Soft Matter Phys ; 68(2 Pt 1): 021701, 2003 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-14524987

RESUMO

Tactoids are droplets of a nematic phase that under suitable conditions form in dispersions of elongated colloidal particles. We theoretically study the shape and the director-field configuration of such droplets for the case where a planar anchoring of the director field to the interface is favored. A minimum of four regimes can be identified in which the droplets have a different structure. Large droplets tend to be nearly spherical with a director field that is bipolar if the surface tension is strongly anisotropic and homogeneous if this is not so. Small droplets can become very elongated and spindlelike if the surface tension is sufficiently anisotropic. Depending on the anchoring strength, the director field is then either homogeneous or bipolar. We find that the more elongated the tactoid, the more strongly it resists the crossing over from a homogeneous to a bipolar structure. This should have implications for the nucleation rate of the nematic phase. Our calculations qualitatively describe the size dependence of the aspect ratio of tactoids found in recent experiments.

17.
Biochimie ; 92(12): 1722-8, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20709141

RESUMO

In this paper we present a theoretical description of the accessibility of nucleosomal DNA to proteins. We reassess the classical analysis of Polach and Widom (1995) who demonstrated that proteins (in their case restriction enzymes) gain access to buried binding sites inside a nucleosome through spontaneous unwrapping of DNA from the protein spool. We introduce a straightforward nucleosome model the predictions of which show good agreement with experimental data. By fitting the model to the data we obtain the values of two quantities: the adsorption energy to the histone octamer per length of DNA and the extra length that the DNA needs to unwrap beyond the binding site of an enzyme before the enzyme can act as effectively as on bare DNA. Our results indicate that the effective binding energy is surprisingly low which suggests that the nucleosomal parameters are tuned such that two large energies, the DNA bending energy and the pure adsorption energy, nearly cancel. This paper is based on a lecture presented at the summer school "DNA and Chromosomes 2009: Physical and Biological Applications". We follow the lecture as closely as possible which is why we spend more time than usual on issues that are already well-known in the field, and why we discuss some well-known results from a different perspective.


Assuntos
Algoritmos , DNA/metabolismo , Modelos Biológicos , Nucleossomos/metabolismo , Proteínas/metabolismo , Sítios de Ligação , DNA/química , Enzimas de Restrição do DNA/química , Enzimas de Restrição do DNA/metabolismo , Histonas/química , Histonas/metabolismo , Cinética , Nucleossomos/química , Ligação Proteica , Proteínas/química , Termodinâmica
18.
J Phys Chem B ; 114(16): 5522-33, 2010 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-20369869

RESUMO

Under conditions of low ionic strength and a pH ranging between about 3.7 and 5.0, solutions of purified coat proteins of cowpea chlorotic mottle virus (CCMV) form spherical multishell structures in the absence of viral RNA. The outer surfaces of the shells in these structures are negatively charged, whereas the inner surfaces are positively charged due to a disordered cationic N-terminal domain of the capsid protein, the arginine-rich RNA-binding motif that protrudes into the interior. We show that the main forces stabilizing these multishells are counterion release combined with a lower charge density in the RNA-binding motif region of the outer shells due to their larger radii of curvature, arguing that these compensate for the outer shells not being able to adopt the smaller, optimal, radius of curvature of the inner shell. This explains why the structures are only stable at low ionic strengths at pHs for which the outer surface is negatively charged and why the larger outer shells are not observed separately in solution. We show how to calculate the free energy of shells of nonoptimal radius of curvature from the elastic properties of the native shell. The spacing between shells is determined mainly by the entropic elasticity of the RNA-binding motifs. Although we focus on CCMV multishells, we also predict the solution conditions under which multishells formed by CCMV coat protein mutants with a lower RNA-binding motif charge are stable, and we examine other viruses as well. We conclude that at a given surface charge density, the boundaries separating regions of stable multishells with different numbers of shells shift to lower ionic strengths upon either increasing the length of the RNA-binding motif, increasing the stiffness of the shells, or decreasing the charge per RNA-binding motif.


Assuntos
Proteínas do Capsídeo/química , Motivos de Aminoácidos , Bromovirus/genética , Proteínas do Capsídeo/genética , Concentração de Íons de Hidrogênio , Modelos Moleculares , Mutação , Concentração Osmolar , Conformação Proteica , Eletricidade Estática , Termodinâmica
19.
J Chem Phys ; 127(11): 115102, 2007 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-17887883

RESUMO

A theory is presented for lambdaC, the coefficient of the first-order correction in the density of the collective diffusion coefficient, for protein spheres interacting by electrostatic and adhesive forces. An extensive numerical analysis of the Stokesian hydrodynamics of two moving spheres is given so as to gauge the precise impact of lubrication forces. An effective stickiness is introduced and a simple formula for lambdaC in terms of this variable is put forward. A precise though more elaborate approximation for lambdaC is also developed. These and numerically exact expressions for lambdaC are compared with experimental data on lysozyme at pH 4.5 and a range of ionic strengths between 0.05M and 2M.


Assuntos
Físico-Química/métodos , Eletricidade Estática , Algoritmos , Biofísica/métodos , Adesão Celular , Difusão , Concentração de Íons de Hidrogênio , Íons , Modelos Estatísticos , Modelos Teóricos , Ligação Proteica , Proteínas/química , Água/química
20.
J Chem Phys ; 125(7): 074903, 2006 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-16942376

RESUMO

We investigate theoretically the fluid-crystal coexistence of solutions of globular charged nanoparticles such as proteins and inorganic colloids. The thermodynamic properties of the fluid phase are computed via the optimized Baxter model P. Prinsen and T. Odijk [J. Chem. Phys. 121, 6525 (2004)]. This is done specifically for lysozyme and silicotungstates for which the bare adhesion parameters are evaluated via the experimental second virial coefficients. The electrostatic free energy of the crystal is approximated by supposing the cavities in the interstitial phase between the particles are spherical in form. In the salt-free case a Poisson-Boltzmann equation is solved to calculate the effective charge on a particle and a Donnan approximation is used to derive the chemical potential and osmotic pressure in the presence of salt. The coexistence data of lysozyme and silicotungstates are analyzed within this scheme, especially with regard to the ionic-strength dependence of the chemical potentials. The latter agree within the two phases provided some upward adjustment of the effective charge is allowed for.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa