Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Glob Heart ; 16(1): 1, 2021 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-33598381

RESUMO

Background: Until recently, Russia did not utilize noninvasive fractional flow reserve (FFR) assessment. We developed an automated algorithm for noninvasive assessment of FFR based on a one-dimensional (1D) mathematical modeling. Objective: The research aims to evaluate the diagnostic accuracy of this algorithm. Methods: The study enrolled 80 patients: 16 of them underwent 64-slice computed tomography - included retrospectively, 64 - prospectively, with a 640-slice CT scan. Specialists processed CT images and evaluated noninvasive FFR. Ischemia was confirmed if FFR < 0.80 and disproved if FFR ≥ 0.80. The prospective group of patients was hospitalized for invasive FFR assessment as a reference standard. If ischemic, patients underwent stent implantation. In the retrospective group, patients already had invasive FFR values.Statistical analysis was performed using GraphPad Prism 8. We compared two methods using a Bland-Altman plot and per-vessel ROC curve analysis. Considering the abnormality of distribution by the Kolmogorov-Smirnov test, we have used Spearman's rank correlation coefficient. Results: During data processing, three patients of the retrospective and 46 patients of the prospective group were excluded. The sensitivity of our method was 66.67% (95% CI: 46.71-82.03); the specificity was 78.95% (95% CI: 56.67-91.49), p = 0.0052, in the per-vessel analysis. In per-patient analysis, the sensitivity was 69.57% (95% CI: 49.13-84.40); the specificity was 87.50% (95% CI: 52.91-99.36), p = 0.0109. The area under the ROC curve in the per-vessel analysis was 77.52% (95% CI: 66.97-88.08), p < 0.0001. Conclusion: The obtained indices of sensitivity, specificity, PPV, and NPV are, in general, comparable to those in other studies. Moreover, the noninvasive values of FFR yielded a high correlation coefficient with the invasive values. However, the AUC was not high enough, 77.52 (95% CI: 66.97-88.08), p < 0.0001. The discrepancy is probably attributed to the initial data heterogeneity and low statistical power.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Humanos , Projetos Piloto , Estudos Prospectivos , Estudos Retrospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
2.
Sci Rep ; 9(1): 721, 2019 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-30679527

RESUMO

Since the 1970s fluorescence imaging has become a leading tool in the discovery of mechanisms of cardiac function and arrhythmias. Gradual improvements in fluorescent probes and multi-camera technology have increased the power of optical mapping and made a major impact on the field of cardiac electrophysiology. Tandem-lens optical mapping systems facilitated simultaneous recording of multiple parameters characterizing cardiac function. However, high cost and technological complexity restricted its proliferation to the wider biological community. We present here, an open-source solution for multiple-camera tandem-lens optical systems for multiparametric mapping of transmembrane potential, intracellular calcium dynamics and other parameters in intact mouse hearts and in rat heart slices. This 3D-printable hardware and Matlab-based RHYTHM 1.2 analysis software are distributed under an MIT open-source license. Rapid prototyping permits the development of inexpensive, customized systems with broad functionality, allowing wider application of this technology outside biomedical engineering laboratories.


Assuntos
Cálcio/metabolismo , Mapeamento Epicárdico/métodos , Coração/fisiologia , Software , Imagens com Corantes Sensíveis à Voltagem/métodos , Animais , Corantes Fluorescentes/química , Camundongos , Perfusão , Ratos , Imagens com Corantes Sensíveis à Voltagem/instrumentação
3.
Int J Numer Method Biomed Eng ; 35(10): e3235, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31315158

RESUMO

Non-invasive coronary computed tomography (CT) angiography-derived fractional flow reserve (cFFR) is an emergent approach to determine the functional relevance of obstructive coronary lesions. Its feasibility and diagnostic performance has been reported in several studies. It is unclear if differences in sensitivity and specificity between these studies are due to study design, population, or "computational methodology." We evaluate the diagnostic performance of four different computational workflows for the prediction of cFFR using a limited data set of 10 patients, three based on reduced-order modelling and one based on a 3D rigid-wall model. The results for three of these methodologies yield similar accuracy of 6.5% to 10.5% mean absolute difference between computed and measured FFR. The main aspects of modelling which affected cFFR estimation were choice of inlet and outlet boundary conditions and estimation of flow distribution in the coronary network. One of the reduced-order models showed the lowest overall deviation from the clinical FFR measurements, indicating that reduced-order models are capable of a similar level of accuracy to a 3D model. In addition, this reduced-order model did not include a lumped pressure-drop model for a stenosis, which implies that the additional effort of isolating a stenosis and inserting a pressure-drop element in the spatial mesh may not be required for FFR estimation. The present benchmark study is the first of this kind, in which we attempt to homogenize the data required to compute FFR using mathematical models. The clinical data utilised in the cFFR workflows are made publicly available online.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Coração/fisiopatologia , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade
4.
Sci Rep ; 8(1): 2921, 2018 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-29440763

RESUMO

Fluorescence optical imaging techniques have revolutionized the field of cardiac electrophysiology and advanced our understanding of complex electrical activities such as arrhythmias. However, traditional monocular optical mapping systems, despite having high spatial resolution, are restricted to a two-dimensional (2D) field of view. Consequently, tracking complex three-dimensional (3D) electrical waves such as during ventricular fibrillation is challenging as the waves rapidly move in and out of the field of view. This problem has been solved by panoramic imaging which uses multiple cameras to measure the electrical activity from the entire epicardial surface. However, the diverse engineering skill set and substantial resource cost required to design and implement this solution have made it largely inaccessible to the biomedical research community at large. To address this barrier to entry, we present an open source toolkit for building panoramic optical mapping systems which includes the 3D printing of perfusion and imaging hardware, as well as software for data processing and analysis. In this paper, we describe the toolkit and demonstrate it on different mammalian hearts: mouse, rat, and rabbit.


Assuntos
Coração/diagnóstico por imagem , Imagem Óptica/métodos , Software , Animais , Imageamento Tridimensional , Camundongos , Coelhos , Ratos
5.
Am J Case Rep ; 19: 724-728, 2018 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-29921835

RESUMO

BACKGROUND Noninvasive assessment of the fractional flow reserve (FFR) in patients with coronary artery disease plays an important role in determining the need for revascularization. It is particularly relevant for patients with a borderline stenoses and painless myocardial ischemia. Our article describes the first clinical experience in the Russian Federation of using an automated method of noninvasive assessment of the fractional flow reserve (FFRct) with a one-dimensional (1-D) mathematical model in a patient with painless myocardial ischemia. CASE REPORT A 58-year-old male patient who underwent stent implantation in the left circumflex coronary artery (LCX) due to an acute non-ST-elevation posterior myocardial infarction had borderline stenoses of the left anterior descending artery (LAD). After stent implantation, there were no relapse angina symptoms on drug treatment, and according to our examination guideline for patients with borderline stenoses, a treadmill test was performed. The test was positive; therefore, FFR assessment was recommended, with coronary multi-slice CT being performed. The following results were obtained: FFRct LAD - 0.57; FFRct LCX - 0.88. An invasive assessment of FFR was also performed as a reference standard and revealed: FFR LAD - 0.6; FFR LCX - 0.88, and simultaneously a LAD percutaneous coronary intervention (PCI) was performed. Three months later, the patient underwent a stress test, which revealed no evidence of induced ischemia. CONCLUSIONS Our method of noninvasive assessment of FFR has shown encouraging results, but we believe that larger-scale studies are needed to establish it as common clinical practice.


Assuntos
Reserva Fracionada de Fluxo Miocárdico , Modelos Teóricos , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatologia , Automação Laboratorial , Implante de Prótese Vascular , Angiografia Coronária , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/terapia , Intervenção Coronária Percutânea , Stents
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa