Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Surg Today ; 53(6): 709-717, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36266480

RESUMO

PURPOSE: To define the impact of the COVID-19 outbreak on hospital surgical activity and assess the incidence of perioperative COVID-19 within two protocolized screening pathways for elective and non-elective surgery. METHODS: We conducted a prospective cohort study of adults undergoing surgery during the COVID-19 outbreak. The elective pathway included telephone surveys and a quantitative polymerase-chain-reaction test (RT-PCR) only for patients who were asymptomatic and at low risk of infection. Only patients with negative screening underwent surgery. In the non-elective pathway, preoperative screening was performed during the hospital admission. RESULTS: Among 835 patients considered for the elective pathway, 725 had negative RT-PCR results and underwent surgery. This reflects an 83% reduction in surgical activity from 2019. Moreover, 596 patients underwent non-elective surgery, representing a 28% reduction. Preoperatively, 39 patients (6.5%) tested positive for SARS-CoV-2 and underwent surgery through the non-elective pathway, vs. none in the elective pathway (p < 0.001). Postoperatively, 1.4% of elective surgery patients and 2.2% of non-elective surgery patients tested positive (p > 0.05). Mortality was higher in non-elective surgery (0.6% vs. 2.9%, p < 0.001) and in patients with COVID-19 (0% vs. 14%, p < 0.001). CONCLUSIONS: The low incidence of COVID-19 in elective surgeries during the outbreak demonstrates the importance and effectiveness of preoperative screening, combining surveys and RT-PCR.


Assuntos
COVID-19 , Adulto , Humanos , COVID-19/diagnóstico , COVID-19/epidemiologia , SARS-CoV-2 , Estudos Prospectivos , Triagem , Procedimentos Cirúrgicos Eletivos
2.
Sensors (Basel) ; 16(11)2016 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-27801796

RESUMO

Cava is a quality sparkling wine produced in Spain. As a product with a designation of origin, Cava wine has to meet certain quality requirements throughout its production process; therefore, the analysis of several parameters is of great interest. In this work, a portable electronic tongue for the analysis of Cava wine is described. The system is comprised of compact and low-power-consumption electronic equipment and an array of microsensors formed by six ion-selective field effect transistors sensitive to pH, Na⁺, K⁺, Ca2+, Cl-, and CO32-, one conductivity sensor, one redox potential sensor, and two amperometric gold microelectrodes. This system, combined with chemometric tools, has been applied to the analysis of 78 Cava wine samples. Results demonstrate that the electronic tongue is able to classify the samples according to the aging time, with a percentage of correct prediction between 80% and 96%, by using linear discriminant analysis, as well as to quantify the total acidity, pH, volumetric alcoholic degree, potassium, conductivity, glycerol, and methanol parameters, with mean relative errors between 2.3% and 6.0%, by using partial least squares regressions.


Assuntos
Técnicas Eletroquímicas/métodos , Nariz Eletrônico , Vinho/análise , Carbonatos/análise , Cloretos/análise , Análise Discriminante , Técnicas Eletroquímicas/instrumentação , Ouro/química , Concentração de Íons de Hidrogênio , Íons/química , Metais/análise , Microeletrodos , Oxirredução
3.
Neurocirugia (Astur) ; 26(1): 23-31, 2015.
Artigo em Espanhol | MEDLINE | ID: mdl-25547393

RESUMO

OBJECTIVE: To assess the diagnostic yield and the incidence of perioperative complications in patients undergoing an open or closed cerebral biopsy and to determine the length of intensive care monitoring, for early diagnosis and fast management of perioperative complications. MATERIAL AND METHOD: This was a retrospective analysis of all the patients that underwent brain biopsy between January 2006 and July 2012. We recorded demographic data, comorbidities, modality of biopsy, intraoperative clinical data, histological results, computed tomography scanning findings and occurrence, and type of perioperative complications and moment of appearance. RESULTS: Seventy-six brain biopsies in 75 consecutive patients (51 closed and 25 open) were analysed. Diagnostic yield was 98% for closed biopsies and 96% for open biopsies. Mortality related to the procedures was 3.9 and 4%, respectively. The incidence of major complications was 3.9% for closed biopsies and 8% for open biopsies; half of these appeared within the first 24 postoperative hours, during patient stay in the Intensive Care Unit. Age was the only risk factor for complications (P=.04) in our study. No differences in morbimortality were found between the studied groups. CONCLUSIONS: Diagnostic yield was very high in our series. Because the importance of early diagnosis of complications for preventing long-term sequelae, we recommend overnight hospital stay for observation after open or closed brain biopsy.


Assuntos
Encéfalo/patologia , Cuidados Pós-Operatórios , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/terapia , Adolescente , Adulto , Idoso , Biópsia , Feminino , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Adulto Jovem
4.
J Thromb Haemost ; 21(1): 37-46, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36695394

RESUMO

BACKGROUND: A low plasma fibrinogen level influences blood component transfusion. Thromboelastometry provides clinical guidance for fibrinogen replacement in liver transplantation (LT). OBJECTIVES: We hypothesized that infusions of fibrinogen concentrate to reach an A10FibTem value of 11 mm during LT could reduce red blood cell (RBC) and other component and fluid requirements in comparison to standard care. METHODS: This randomized, blinded, multicenter trial in 3 hospitals enrolled 189 LT-scheduled patients allocated to an intervention target (A10FibTem, 11 mm) or a standard target (A10FibTem, 8 mm); 176 patients underwent LT with fibrinogen replacement. Data were analyzed by intention-to-treat (intervention group, 91; control group, 85). Blood was extracted, and fibrinogen kits were prepared to bring each patient's fibrinogen level to the assigned target at the start of LT, after portal vein clamping, and after graft reperfusion. The main outcome was the proportion of patients requiring RBC transfusion during LT or within 24 hours. RESULTS: The proportion of patients requiring RBCs did not differ between the groups: intervention, 74.7% (95% CI, 65.5%-83.3%); control, 72.9% (95% CI, 62.2%-82.0%); absolute difference, 1.8% (95% CI, -11.1% to 14.78%) (P = .922). Thrombotic events occurred in 4% of the patients in both groups; reoperation and retransplantation rates and mortality did not differ. Nearly 70% of the patients in both groups required fibrinogen concentrate to reach the target. Using an 11-mm A10FibTem target increased the maximum clot firmness without affecting safety. However, this change provided no clinical benefits. CONCLUSION: The similar low plasma fibrinogen concentrations could explain the lack of significant between-group outcomes.


Assuntos
Hemostáticos , Transplante de Fígado , Humanos , Fibrinogênio/efeitos adversos , Transplante de Fígado/efeitos adversos , Tromboelastografia , Transfusão de Componentes Sanguíneos
5.
Biosens Bioelectron ; 234: 115342, 2023 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-37141829

RESUMO

The early detection of very low bacterial concentrations is key to minimize the healthcare and safety issues associated with microbial infections, food poisoning or water pollution. In amperometric integrated circuits for electrochemical sensors, flicker noise is still the main bottleneck to achieve ultrasensitive detection with small footprint, cost-effective and ultra-low power instrumentation. Current strategies rely on autozeroing or chopper stabilization causing negative impacts on chip size and power consumption. This work presents a 27-µW potentiostatic-amperometric Delta-Sigma modulator able to cancel its own flicker noise and provide a 4-fold improvement in the limit of detection. The 2.3-mm2 all-in-one CMOS integrated circuit is glued to an inkjet-printed electrochemical sensor. Measurements show that the limit of detection is 15 pArms, the extended dynamic range reaches 110 dB and linearity is R2 = 0.998. The disposable device is able to detect, in less than 1h, live bacterial concentrations as low as 102 CFU/mL from a 50-µL droplet sample, which is equivalent to 5 microorganisms.


Assuntos
Bactérias , Técnicas Biossensoriais , Técnicas Biossensoriais/instrumentação , Bactérias/isolamento & purificação
6.
Lancet Respir Med ; 6(3): 193-203, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29371130

RESUMO

BACKGROUND: The effects of individualised perioperative lung-protective ventilation (based on the open-lung approach [OLA]) on postoperative complications is unknown. We aimed to investigate the effects of intraoperative and postoperative ventilatory management in patients scheduled for abdominal surgery, compared with standard protective ventilation. METHODS: We did this prospective, multicentre, randomised controlled trial in 21 teaching hospitals in Spain. We enrolled patients who were aged 18 years or older, were scheduled to have abdominal surgery with an expected time of longer than 2 h, had intermediate-to-high-risk of developing postoperative pulmonary complications, and who had a body-mass index less than 35 kg/m2. Patients were randomly assigned (1:1:1:1) online to receive one of four lung-protective ventilation strategies using low tidal volume plus positive end-expiratory pressure (PEEP): open-lung approach (OLA)-iCPAP (individualised intraoperative ventilation [individualised PEEP after a lung recruitment manoeuvre] plus individualised postoperative continuous positive airway pressure [CPAP]), OLA-CPAP (intraoperative individualised ventilation plus postoperative CPAP), STD-CPAP (standard intraoperative ventilation plus postoperative CPAP), or STD-O2 (standard intraoperative ventilation plus standard postoperative oxygen therapy). Patients were masked to treatment allocation. Investigators were not masked in the operating and postoperative rooms; after 24 h, data were given to a second investigator who was masked to allocations. The primary outcome was a composite of pulmonary and systemic complications during the first 7 postoperative days. We did the primary analysis using the modified intention-to-treat population. This trial is registered with ClinicalTrials.gov, number NCT02158923. FINDINGS: Between Jan 2, 2015, and May 18, 2016, we enrolled 1012 eligible patients. Data were available for 967 patients, whom we included in the final analysis. Risk of pulmonary and systemic complications did not differ for patients in OLA-iCPAP (110 [46%] of 241, relative risk 0·89 [95% CI 0·74-1·07; p=0·25]), OLA-CPAP (111 [47%] of 238, 0·91 [0·76-1·09; p=0·35]), or STD-CPAP groups (118 [48%] of 244, 0·95 [0·80-1·14; p=0·65]) when compared with patients in the STD-O2 group (125 [51%] of 244). Intraoperatively, PEEP was increased in 69 (14%) of patients in the standard perioperative ventilation groups because of hypoxaemia, and no patients from either of the OLA groups required rescue manoeuvres. INTERPRETATION: In patients who have major abdominal surgery, the different perioperative open lung approaches tested in this study did not reduce the risk of postoperative complications when compared with standard lung-protective mechanical ventilation. FUNDING: Instituto de Salud Carlos III of the Spanish Ministry of Economy and Competitiveness, and Grants Programme of the European Society of Anaesthesiology.


Assuntos
Abdome/cirurgia , Assistência Perioperatória/métodos , Respiração com Pressão Positiva/métodos , Complicações Pós-Operatórias/etiologia , Respiração Artificial/métodos , Idoso , Feminino , Humanos , Pulmão/fisiopatologia , Pulmão/cirurgia , Masculino , Pessoa de Meia-Idade , Respiração com Pressão Positiva/efeitos adversos , Estudos Prospectivos , Respiração Artificial/efeitos adversos , Espanha , Resultado do Tratamento
7.
Neurocir. - Soc. Luso-Esp. Neurocir ; 26(1): 23-31, ene.-feb. 2015. tab
Artigo em Espanhol | IBECS (Espanha) | ID: ibc-133395

RESUMO

Objetivo: Determinar la eficacia diagnóstica y la incidencia de complicaciones perioperatorias en pacientes sometidos a biopsia cerebral cerrada o por craneotomía, y valorar la duración de la vigilancia intensiva, para el diagnóstico precoz y el manejo de las complicaciones posoperatorias. Material y método: Estudio observacional retrospectivo, incluyendo todos los pacientes sometidos a biopsia cerebral entre enero de 2006 y julio de 2012. Se recogieron los datos demográficos, enfermedad asociada, tipo de biopsia, datos relevantes del intraoperatorio, el resultado de la anatomía patológica, la realización de prueba de imagen cerebral y su resultado, y la presencia, tipo y momento de aparición de las complicaciones posoperatorias. Resultados: Se analizaron un total de 76 biopsias (51 «cerradas», 25 «abiertas») en 75 pacientes. La efectividad diagnóstica fue del 98% en las «cerradas» y del 96% en las «abiertas». La mortalidad relacionada con el procedimiento fue de 3,9 y 4%, respectivamente. La incidencia de complicaciones mayores fue del 3,9% en biopsias «cerradas» y del 8% en biopsias «abiertas», apareciendo la mitad de ellas dentro de las primeras 24 h del posoperatorio, durante el ingreso en la Unidad de Cuidados Intensivos. La edad fue el único factor de riesgo para la aparición de complicaciones (p = 0,04). No encontramos diferencias de morbimortalidad entre los 2 grupos analizados. Conclusiones: La eficacia diagnóstica de nuestra serie ha sido muy alta. Dada la importancia del diagnóstico precoz de las complicaciones, recomendamos una vigilancia monitorizada en las primeras 24 h tras la realización de una biopsia cerebral tanto «abierta» como «cerrada»


Objective: To assess the diagnostic yield and the incidence of perioperative complications in patients undergoing an open or closed cerebral biopsy and to determine the length of intensive care monitoring, for early diagnosis and fast management of perioperative complications. Material and method: This was a retrospective analysis of all the patients that underwent brain biopsy between January 2006 and July 2012. We recorded demographic data, comorbidities, modality of biopsy, intraoperative clinical data, histological results, computed tomography scanning findings and occurrence, and type of perioperative complications and moment of appearance. Results: Seventy-six brain biopsies in 75 consecutive patients (51 closed and 25 open) were analysed. Diagnostic yield was 98% for closed biopsies and 96% for open biopsies. Mortality related to the procedures was 3.9 and 4%, respectively. The incidence of major complications was 3.9% for closed biopsies and 8% for open biopsies; half of these appeared within the first 24 postoperative hours, during patient stay in the Intensive Care Unit. Age was the only risk factor for complications (P = .04) in our study. No differences in morbimortality were found between the studied groups. Conclusions: Diagnostic yield was very high in our series. Because the importance of early diagnosis of complications for preventing long-term sequelae, we recommend overnight hospital stay for observation after open or closed brain biopsy


Assuntos
Humanos , Biópsia/métodos , Craniotomia/métodos , Neoplasias Encefálicas/diagnóstico , Estudos Retrospectivos , /métodos , Complicações Pós-Operatórias/prevenção & controle , Monitorização Fisiológica
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa