Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Surg Technol Int ; 26: 261-8, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-26055018

RESUMO

The eLibra® Dynamic Knee Balancing System (Synvasive Technology, Zimmer, Warsaw, IN) is an instrument designed to address the flexion stability during a TKA. It provides an objective measurement of the soft-tissue forces in the two compartments before the final cuts are made, allowing to obtain patient-specific rotational orientation of the femoral component. Between March 2010 and March 2012, the eLibra® system was used during the implantation of 75 TKAs in 75 patients at the author's institution. Preoperative and postoperative clinical assessment were evaluated using the Knee Society Score (KSS) and the Visual Analogical Scale (VAS). Radiographic evaluation was performed with weight-bearing radiographs in antero-posterior and lateral views in order to study the presence of radiolucencies. In a sample of 20 patients, representative of the population studied, the rotation of the femoral component was measured by two independent observers using the C-arm Cone Beam CT scan (XperCT/Allura FD20 angiography system; Philips, Best, Netherlands). At a mean follow-up of 42.3 months (29-54 months), three patients died from causes not related to the surgery. We had one case of aseptic loosening three years after surgery. None of the patients reported complications peri- or postoperatively. Clinical evaluation showed an improvement in KSS scoring, from preoperative means of 48.35 and 47.53 points for clinical and functional aspects, respectively, to postoperative means of 88.03 and 91.2 points, respectively (p<0.001 for both aspects). The current study demonstrates that the use of the eLibra® device is simple and reproducible. It could help surgeons objectively quantify ligament balance and perform soft tissue-guided resection in a reproducible way, resulting in better post-operative stability and reduced complications. The use of the postoperative cone beam computed tomography (CBCT), in a representative sample of patients, revealed a specific and optimal orientation of the femoral component with a mean of 2.18° of external rotation.


Assuntos
Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Articulação do Joelho/fisiologia , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Radiografia
2.
Open Orthop J ; 7: 190-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23898351

RESUMO

Infection is a frequent cause of failure after joint replacement surgery. The infection rate after total hip arthroplasty (THA) has been reduced to 1-2% in the last years. However, it still represents a challenging problem for the orthopedic surgeon. Difficulty of therapeutic approach, and poor functional outcomes together with length of treatment and overall cost are the main burden of this issue. Even the diagnosis of an infected hip could be challenging although it is the first step of an accurate treatment. At the end, many cases require removing the implants. Afterwards, the treatment strategy varies according to authors with three different procedures: no re-implantation, immediate placement of new implants or a two-stage surgery re-implantation. Based on the most recently systematic review there is no suggestion that one- or two-stage revision methods have different re-infection outcomes. The two-stage implant-exchange protocol remains the gold standard. It is considered as the most efficacious clinical approach for the treatment of periprosthetic infection, especially in patients with sinus tracts, swelling, extended abscess formation in depth and infection of Methicillin Resistant Staphylococcus Aureus (MRSA), and other multidrug-resistant bacteria as reported in recent consensus documents.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa