Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
J Occup Environ Hyg ; 21(7): 494-503, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38838303

RESUMO

The objective was to study the interaction of the components of a complex liquid mixture on the permeation parameters of its constituents. A firearm cleaning solvent, Hoppes No. 9 Gun Bore Cleaner, was selected to challenge two varieties of disposable nitrile gloves, the thinnest (Kimberly-Clark Lavender) and thickest (Kimberly-Clark Blue), using the closed-loop ASTM F739 cell without recirculation and n-decane collection followed by quantitation of the permeated compounds using capillary gas chromatography-mass spectrometry. The thicker Blue glove resisted the permeation of Hoppe's relative to the thinner Lavender glove as shown by 3.2 times more mass permeated by the Lavender glove at 60 min despite the same standardized breakthrough times (7.5 ± 2.5 min). The kerosene fraction permeated faster at a much higher rate than expected. The Kimberly-Clark disposable nitrile glove chemical resistance guide lists a breakthrough time for kerosene of 82 min for Sterling disposable nitrile glove material. However, for Hoppe's the kerosene components appeared at the standardized breakthrough time. Mixture components that were reported by the glove manufacturer to quickly permeate the disposable nitrile material, such as ethanol, did not permeate at a rate slower than expected, indicative of a possible carrier function. A semiquantitative risk assessment confirmed the unacceptability of both gloves. Persons using personal protective equipment, such as gloves, may not be afforded the expected resistance to chemical permeation when chemicals are in a suitable mixture, hence enhancing the risk of exposure. More research is needed to produce better glove testing measures to ensure the safety of workers.


Assuntos
Armas de Fogo , Luvas Protetoras , Nitrilas , Permeabilidade , Solventes , Nitrilas/química , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/análise , Humanos , Teste de Materiais , Cromatografia Gasosa-Espectrometria de Massas
2.
J Occup Environ Hyg ; 17(4): 135-164, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32209007

RESUMO

This second part of the review of the 21st century literature on glove permeation is divided into the following major themes; permeation data and mathematical models, exposure/risk assessment, and manufacturer data. The major issues in the literature were the demonstrations that increasing temperature and applying forces increased permeation; and that glove manufacturer data were sometimes not reproducible. Double gloving of disposable gloves was found to be effective in resisting chemical permeation for short periods of time. Harmonization of standards and commercial glove classifications were called for at conditions that were closer to the temperature and applied forces actually present in the workplace, including whole glove testing and quantitative rather than just qualitative criteria. More research was recommended in each section and subsection with particular emphasis on defining the efficiency of solid phase collection devices, and more data in areas like exposure to cosmetics, household products, liquid foods, drinks, and cleaning liquids. More research in exposure assessment for permeated chemicals with sensors on the inner glove surface and on the skin was called for. Finally, it was decided that the state of the art of current practice was in a situation that needed the permeation standards, research, and the permeation charts of glove manufacturers to be at conditions that better reflected those encountered by workers with donned gloves.


Assuntos
Luvas Protetoras , Exposição Ocupacional/prevenção & controle , Humanos , Modelos Teóricos , Permeabilidade , Temperatura de Transição
3.
J Occup Environ Hyg ; 17(7-8): 334-342, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32469690

RESUMO

Double gloving of disposable gloves is now commonplace in healthcare settings when extra protection is needed against aqueous solutions and especially for antineoplastic drugs in isotonic aqueous media. In the present study, an ASTM F739 2.54 cm cell with closed-loop water collection without recirculation at 35 °C in a moving tray water bath was used to test the permeation of diethylene glycol mono-n-butyl ether (DGBE) through four types of disposable nitrile gloves that were singly and doubly layered in the permeation cell. Samples were taken over 8 hr for capillary gas chromatograph-mass spectrometer quantitation. The breakthrough time (tn) at a permeation of 250 ng/cm2 increased as thickness increased for single layers, but the steady-state permeation rates Ps in µg/cm2/min did not always decrease with increasing thickness. The double-layer tn, Ps and thickness were also more variable relative to a single layer. The thinnest glove with 80 [Formula: see text]m thickness showed a tn = 0-5 min whereas its double layer was 15-20 min. The thickest glove of 132 µm exhibited a tn = 10-15 min but its double layer was tn = 45-55 min. The adjusted double-layer average tn divided by the adjusted single-layer average tn was 4.0 ± 0.8. The adjusted average single-layer Ps divided by the adjusted average double-layer Ps was 3.5 ± 0.8. Other results showed that the average glove swelling was <10%; microscopic and leak testing indicated no penetration and reflectance infrared analysis also showed no chemical changes on the inside glove surfaces. Thus, the permeations were adjudged to obey Fick's First Law of Diffusion to allow calculation of diffusion coefficients D in cm2/min. The average single-layer D divided by the average double-layer D was 1.3 ± 0.2. Double gloving in the field is therefore also probably more protective than single gloving against DGBE for the four types of disposable nitrile gloves tested.


Assuntos
Etilenoglicóis/química , Luvas Protetoras , Teste de Materiais , Nitrilas , Permeabilidade
4.
PLoS Genet ; 12(7): e1006223, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27472198

RESUMO

Concerns about the safety of Bisphenol A, a chemical found in plastics, receipts, food packaging and more, have led to its replacement with substitutes now found in a multitude of consumer products. However, several popular BPA-free alternatives, such as Bisphenol S, share a high degree of structural similarity with BPA, suggesting that these substitutes may disrupt similar developmental and reproductive pathways. We compared the effects of BPA and BPS on germline and reproductive functions using the genetic model system Caenorhabditis elegans. We found that, similarly to BPA, BPS caused severe reproductive defects including germline apoptosis and embryonic lethality. However, meiotic recombination, targeted gene expression, whole transcriptome and ontology analyses as well as ToxCast data mining all indicate that these effects are partly achieved via mechanisms distinct from BPAs. These findings therefore raise new concerns about the safety of BPA alternatives and the risk associated with human exposure to mixtures.


Assuntos
Compostos Benzidrílicos/toxicidade , Caenorhabditis elegans/efeitos dos fármacos , Células Germinativas/efeitos dos fármacos , Fenóis/toxicidade , Sulfonas/toxicidade , Animais , Apoptose/efeitos dos fármacos , Caenorhabditis elegans/genética , Caenorhabditis elegans/crescimento & desenvolvimento , Embrião não Mamífero/efeitos dos fármacos , Desenvolvimento Embrionário/genética , Embalagem de Alimentos , Regulação da Expressão Gênica no Desenvolvimento/efeitos dos fármacos , Humanos , Biossíntese de Proteínas/efeitos dos fármacos , Transcriptoma/efeitos dos fármacos
5.
J Occup Environ Hyg ; 14(4): 243-251, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27754775

RESUMO

The aim was to develop a whole glove permeation method for cyclohexanol to generate permeation parameter data for a non-moving dextrous robot hand (normalized breakthrough time tb, standardized breakthrough time ts, steady state permeation rate Ps, and diffusion coefficient D). Four types of disposable powderless, unsupported, and unlined nitrile gloves from the same producer were investigated: Safeskin Blue and Kimtech Science Blue, Purple, and Sterling. The whole glove method developed involved a peristaltic pump for water circulation through chemically resistant Viton tubing to continually wash the inner surface of the test glove via holes in the tubing, a dextrous robot hand operated by a microprocessor, a chemically protective nitrile glove to protect the robot hand, an incubator to maintain 35°C temperature, and a hot plate to maintain 35°C at the sampling point of the circulating water. Aliquots of 1.0 mL were sampled at regular time intervals for the first 60 min followed by removal of 0.5 mL aliquots every hour to 8 hr. Quantification was by the internal standard method after gas chromatography-selective ion electron impact mass spectrometry using a non-polar capillary column. The individual glove values of tb and ts differed for the ASTM closed loop method except for Safeskin Blue, but did not for the whole glove method. Most of the kinetic parameters agreed within an order of magnitude for the two techniques. The order of most protective to least protective glove was Blue and Safeskin, then Purple followed by Sterling for the whole gloves. The analogous order for the modified F739 ASTM closed loop method was: Safeskin, Blue, Purple, and Sterling, almost the same as for the whole glove. The Sterling glove was "not recommended" from the modified ASTM data, and was "poor" from the whole glove data.


Assuntos
Cicloexanóis/química , Luvas Protetoras , Teste de Materiais/métodos , Cicloexanóis/análise , Cromatografia Gasosa-Espectrometria de Massas , Mãos , Humanos , Nitrilas/química , Permeabilidade , Robótica
6.
J Occup Environ Hyg ; 14(4): 252-257, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27754818

RESUMO

The differences in permeation parameters when a gloved dextrous robot hand clenched and did not were investigated with the dynamic permeation system described in the companion paper. Increased permeation through the gloves of the present study for cyclohexanol when the gloved hand clenched depended on glove thickness and porosity for cyclohexanol permeation. The Sterling glove, the thinnest and most porous, was the least protective. Hand clenching promoted more permeation for the Sterling glove in terms of breakthrough times, steady state permeation rate, and diffusion coefficient. The Safeskin glove showed increased permeation only for the steady state permeation rate but not breakthrough times or diffusion coefficient. The Blue and Purple gloves showed no differences when the hand was clenching or not. The correlational analysis supported differences between the clenching and non-clenching situations, and the risk assessment considered the worst and best scenarios relative to one and two hydrated hands that were and were not protected by specific gloves.


Assuntos
Cicloexanóis/química , Luvas Protetoras , Teste de Materiais/métodos , Cicloexanóis/análise , Cromatografia Gasosa-Espectrometria de Massas , Mãos , Humanos , Nitrilas/química , Permeabilidade , Robótica
7.
J Chem Health Saf ; 31(3): 253-258, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38818310

RESUMO

The current technique to assess glove resistance to chemicals for worker protection relies on challenging a flat, 2.54 cm diameter glove piece at or near room temperature. This does not simulate a donned whole glove near the skin temperature subjected to work activity forces. Four different types of disposable nonpowdered unlined/unsupported nitrile gloves in triplicate were measured for thickness, porosity, and for the acrylonitrile content (A) of the challenge and collection sides. Limonene permeation at 35 °C through a whole glove on a clenching and nonclenching dextrous robot hand and with the standard ASTM F739 technique were facilitated by taking samples from the collection sides for GC-MS analysis. The standardized breakthrough time (SBT) when permeation reached 100 ng/cm2/min and the steady state permeation rate (SSPR) depended on A, thickness, and porosity. Only the thinnest glove (Lavender) showed statistically significant (p ≤ 0.05) increased average SSPR for the clenching hand relative to the nonclenching hand and for the ASTM technique. The ASTM test data for the three thickest gloves were not statistically different from those of the robot hand, but differed from the manufacturer's. More research with different chemicals and higher clenching forces is needed. Clenching forces can enhance the permeation. Workers wearing ultrathin disposable nitrile gloves have a higher potential for chemical penetration/permeation. Company glove permeation data obtained near room temperature may have a longer SBT and lower SSPR than in practice. Double gloving may be advisible in emergencies and for unknown chemicals when no appropriate thicker Chemical Protective glove is available.

8.
Proc Natl Acad Sci U S A ; 106(31): 12623-8, 2009 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-19620728

RESUMO

The long-standing controversy regarding the late Pleistocene megafaunal extinctions in North America has been invigorated by a hypothesis implicating a cosmic impact at the Allerød-Younger Dryas boundary or YDB (approximately 12,900 +/- 100 cal BP or 10,900 +/- 100 (14)C years). Abrupt ecosystem disruption caused by this event may have triggered the megafaunal extinctions, along with reductions in other animal populations, including humans. The hypothesis remains controversial due to absence of shocked minerals, tektites, and impact craters. Here, we report the presence of shock-synthesized hexagonal nanodiamonds (lonsdaleite) in YDB sediments dating to approximately 12,950 +/- 50 cal BP at Arlington Canyon, Santa Rosa Island, California. Lonsdaleite is known on Earth only in meteorites and impact craters, and its presence strongly supports a cosmic impact event, further strengthened by its co-occurrence with other nanometer-sized diamond polymorphs (n-diamonds and cubics). These shock-synthesized diamonds are also associated with proxies indicating major biomass burning (charcoal, carbon spherules, and soot). This biomass burning at the Younger Dryas (YD) onset is regional in extent, based on evidence from adjacent Santa Barbara Basin and coeval with broader continent-wide biomass burning. Biomass burning also coincides with abrupt sediment mass wasting and ecological disruption and the last known occurrence of pygmy mammoths (Mammuthus exilis) on the Channel Islands, correlating with broader animal extinctions throughout North America. The only previously known co-occurrence of nanodiamonds, soot, and extinction is the Cretaceous-Tertiary (K/T) impact layer. These data are consistent with abrupt ecosystem change and megafaunal extinction possibly triggered by a cosmic impact over North America at approximately 12,900 +/- 100 cal BP.


Assuntos
Biomassa , Diamante , Extinção Biológica , Sedimentos Geológicos , Ecossistema , Microscopia Eletrônica de Transmissão
9.
Arch Environ Contam Toxicol ; 58(2): 249-54, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19855916

RESUMO

The aim of this study was to measure permeation of the herbicide dichlobenil in Casoron 4G through disposable and chemically protective nitrile gloves using an American Society for Testing and Materials-type permeation cell and a closed-loop system employing two different solvents (hexane and water) and two different challenge situations (aqueous emulsion and solid formulation). Capillary gas chromatography-mass spectrometry was used for quantification purposes. The chemically protective glove did not allow any permeation up to 8 h for the solid-formulation and water-collection challenges, but permeation was detected in all other challenges. The disposable glove allowed the most permeation, and the solid-formulation challenge with water collection necessitated that a dichlobenil equivalent be calculated because of the presence of its hydrolysis degradation product 2,6-dichlorobenzamide. Permeation from the solid formulation was detectable by hexane collection for both the disposable and chemically protective gloves and by water collection for the disposable glove. It was concluded that hexane-solvent collection was not valid for the disposable glove at 4 and 8 h of permeation in the solid Casoron challenge or for the aqueous emulsion challenge at 8 h relative to the water-collection solvent data. The hexane-solvent collection for the chemically protective glove was valid for the 8-h solid-formulation challenge but not for the 8-h aqueous-solution challenge. All water-solvent collections were valid; however, dichlobenil usually permeated the gloves.


Assuntos
Luvas Protetoras , Herbicidas/química , Nitrilas/química , Benzamidas/química , Equipamentos Descartáveis , Estabilidade de Medicamentos , Cromatografia Gasosa-Espectrometria de Massas , Herbicidas/análise , Hexanos/química , Hidrólise , Nitrilas/análise , Permeabilidade , Solubilidade , Solventes/química , Fatores de Tempo , Água/química
10.
Bull Environ Contam Toxicol ; 84(1): 5-7, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19784533

RESUMO

Whole glove testing for a metalworking fluid (MWF) in the field was performed for the first time. Green latex gloves used in a machine shop were exposed for 20 min to MWF. The permeated amount (1.0 +/- 0.5 microg/cm(2)) was higher than the threshold (0.25 microg/cm(2)) for the ASTM F739-99a closed-loop normalized breakthrough time.


Assuntos
Poluentes Ambientais/química , Luvas Protetoras , Metalurgia , Exposição Ocupacional , Análise de Falha de Equipamento , Humanos , Permeabilidade
11.
J Hazard Mater ; 151(2-3): 692-8, 2008 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-17662521

RESUMO

The influence of collection solvents hexane and perfluorohexane on the permeation of the non-polar and non-volatile di-n-octyl disulfide (DOD) through nitrile glove material was investigated using the American Society for Testing and Materials (ASTM) F739-99a method. The weight and the thickness of the nitrile material increased about 6%, statistically significant at p

Assuntos
Ácidos Alcanossulfônicos/química , Fluorocarbonos/química , Luvas Protetoras , Nitrilas/química , Solventes/química , Cromatografia Gasosa/métodos , Desenho de Equipamento , Fluorocarbonos/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Substâncias Perigosas , Espectrometria de Massas/métodos , Teste de Materiais , Modelos Estatísticos , Exposição Ocupacional , Roupa de Proteção , Fatores de Tempo
12.
Appl Spectrosc ; 61(2): 204-11, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17331313

RESUMO

The aim of this study was to investigate the surface variability of 13 powder-free, unlined, and unsupported nitrile rubber gloves using attenuated total reflection Fourier transform infrared (ATR-FT-IR) spectrophotometry at key wavelengths for analysis of captan contamination. The within-glove, within-lot, and between-lot variability was measured at 740, 1124, 1252, and 1735 cm(-1), the characteristic captan reflectance minima wavelengths. Three glove brands were assessed after conditioning overnight at relative humidity (RH) values ranging from 2 +/- 1 to 87 +/- 4% and temperatures ranging from -8.6 +/- 0.7 to 59.2 +/- 0.9 degrees C. For all gloves, 1735 cm(-1) provided the lowest background absorbance and greatest potential sensitivity for captan analysis on the outer glove surface: absorbances ranged from 0.0074 +/- 0.0005 (Microflex) to 0.0195 +/- 0.0024 (SafeSkin); average within-glove coefficients of variation (CV) ranged from 2.7% (Best, range 0.9-5.3%) to 10% (SafeSkin, 1.2-17%); within-glove CVs greater than 10% were for one brand (SafeSkin); within-lot CVs ranged from 2.8% (Best N-Dex) to 28% (SafeSkin Blue); and between-lot variation was statistically significant (p < or = 0.05) for all but two SafeSkin lots. The RH had variable effects dependent on wavelength, being minimal at 1735, 1252, and 1124 cm(-1) and highest at 3430 cm(-1) (O-H stretch region). There was no significant effect of temperature conditioning. Substantial within-glove, within-lot, and between-lot variability was observed. Thus, surface analysis using ATR-FT-IR must treat glove brands and lots as different. ATR-FT-IR proved to be a useful real-time analytical tool for measuring glove variability, detecting surface humidity effects, and choosing selective and sensitive wavelengths for analysis of nonvolatile surface contaminants.


Assuntos
Captana/análise , Elastômeros/química , Fungicidas Industriais/análise , Luvas Protetoras , Nitrilas/química , Umidade , Indicadores e Reagentes , Espectrofotometria Infravermelho , Espectroscopia de Infravermelho com Transformada de Fourier , Temperatura
13.
J Hazard Mater ; 147(3): 923-9, 2007 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-17324502

RESUMO

The aim was to investigate the permeation of a straight oil metalworking fluid (MWF) through four types of glove materials using the gravimetric method and the modified American Society for Testing and Materials (ASTM) F739-99a method with perfluorohexane and hexane as collection solvents. The residual masses on the collection side were determined after solvent evaporation for both MWF and blank (air) challenges. With perfluorohexane, the permeated MWF through gloves after 8h was around the lower quantifiable limit for nitrile, 0.7+/-0.2mg/cm(2) for vinyl, 10.0+/-1.2mg/cm(2) for chloroprene, and 33.0+/-0.7mg/cm(2) for latex. Hexane increased the amounts and rates of MWF permeating all gloves 39-73 times, except for vinyl where extractable mass was so high that the residues for MWF challenges and for hexane blanks were indistinguishable. Hexane as a collection solvent also extracted more glove components than did perfluorohexane, and back-permeated gloves in much larger amounts. Perfluorohexane allows better estimates of the real permeation rates and breakthrough times than does hexane. Recommendations based on breakthrough times and permeation rates with hexane collection are thus too conservative, although the relative ranking of these four types of gloves was the same with either collection solvent.


Assuntos
Cloropreno/química , Luvas Protetoras , Látex/química , Óleo Mineral/química , Nitrilas/química , Exposição Ocupacional , Cloreto de Polivinila/química , Permeabilidade , Solventes/química
14.
J Occup Health ; 59(2): 131-138, 2017 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-28111415

RESUMO

OBJECTIVES: The purpose of this study was to investigate the permeation of the low-volatile solvent limonene through different disposable, unlined, unsupported, nitrile exam whole gloves (blue, purple, sterling, and lavender, from Kimberly-Clark). METHODS: This study utilized a moving and static dextrous robot hand as part of a novel dynamic permeation system that allowed sampling at specific times. Quantitation of limonene in samples was based on capillary gas chromatography-mass spectrometry and the internal standard method (4-bromophenol). RESULTS: The average post-permeation thicknesses (before reconditioning) for all gloves for both the moving and static hand were more than 10% of the pre-permeation ones (P≤0.05), although this was not so on reconditioning. The standardized breakthrough times and steady-state permeation periods were similar for the blue, purple, and sterling gloves. Both methods had similar sensitivity. The lavender glove showed a higher permeation rate (0.490±0.031 µg/cm2/min) for the moving robotic hand compared to the non-moving hand (P≤0.05), this being ascribed to a thickness threshold. CONCLUSIONS: Permeation parameters for the static and dynamic robot hand models indicate that both methods have similar sensitivity in detecting the analyte during permeation and the blue, purple, and sterling gloves behave similarly during the permeation process whether moving or non-moving.


Assuntos
Cicloexenos/química , Luvas Protetoras , Nitrilas/química , Exposição Ocupacional/análise , Terpenos/química , Cicloexenos/análise , Falha de Equipamento , Cromatografia Gasosa-Espectrometria de Massas , Luvas Protetoras/classificação , Mãos , Humanos , Limoneno , Teste de Materiais/métodos , Exposição Ocupacional/prevenção & controle , Permeabilidade , Robótica , Terpenos/análise
15.
J Chromatogr A ; 1101(1-2): 25-31, 2006 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-16233901

RESUMO

The aim of this study was to identify and quantify an unknown peak in the chromatogram of a very complex mixture, a straight oil metalworking fluid (MWF). The fraction that permeated through a thin nitrile polymer membrane had less mineral oil background than the original MWF did at the retention time of the unknown peak, thus facilitating identification by total ion current (TIC) gas chromatography-mass spectrometry (GC-MS). The peak proved to be di-n-octyl disulfide (DOD) through retention time and mass spectral comparisons. Quantitation of DOD was by extracted ion chromatogram analysis of the DOD molecular ion (mass-to-charge ratio (m/z) 290), and of the m/z 71 ion for the internal standard, n-triacontane. Linear models of the area ratio (y) of these two ions versus DOD concentration showed a systematic negative bias at low concentrations, a common occurrence in analysis. The linear model of y(0.8) (from Box-Cox power transformation) versus DOD concentration showed negligible bias from the lowest measured standard of 1.51 mg/L to the highest concentration tested at 75.5 mg/L. The intercept did not differ statistically from zero. The concentration of DOD in the MWF was then calculated to be 0.398+/-0.034% (w/w) by the internal standard method, and 0.387+/-0.036% (w/w) by the method of standard additions. These two results were not significantly different at p < or = 0.05. The Box-Cox transformation is therefore recommended when the data for standards are non-linear.


Assuntos
Ácidos Alcanossulfônicos/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Metalurgia/métodos , Calibragem , Interpretação Estatística de Dados
16.
J Hazard Mater ; 137(1): 165-71, 2006 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-16713085

RESUMO

The goal of the study was to assess how protective disposable (Safeskin) and chemical protective (Sol-Vex) nitrile gloves were against Comite emulsifiable concentrate formulation containing propargite (PROP) as active pesticidal ingredient, because there were no explicit recommendations for the gloves that should be worn for hand protection. The glove material was exposed in ASTM-type I-PTC-600 permeation cells at 30.0+/-0.5 degrees C, and gas chromatography-mass spectrometry used for PROP analysis. Aqueous solutions of Comite at 40.4 mg/mL permeated both Safeskin and Sol-Vex nitrile by 8h. Safeskin showed a mean PROP mass permeated of 176+/-27 microg after 8h compared with a mean mass permeated for Sol-Vex of 3.17+/-4.08 microg. Thus, Sol-Vex was about 56 times more protective than Safeskin for an 8-h exposure. However, the kinetics of the permeation revealed that Safeskin can be worn for at least 200 min before disposal. When undiluted Comite challenged both types of nitrile, much faster permeation was observed. Safeskin gloves showed two steady state periods. The first had lag times (t(l)) values of about 1h, although normalized breakthrough times (t(b)) were < 10 min. The second steady state rate (P(s)) was on average four times the rate of the first period, and the second steady state period t(l) was about three times as long as that of the first steady state period, and about the same t(l) as for the aqueous solution. Sol-Vex gloves exposed continuously to undiluted Comite permeated above the normalized breakthrough threshold beyond 2.7h. A risk assessment revealed that the PROP skin permeation rate of 7.1 ng cm(-2)h(-1) was much slower than the first steady state Safeskin glove P(s) of 62,000 ng cm(-2)h(-1). Infrared analysis showed that the glove surfaces were not degraded by the Comite challenge. The chemically protective Sol-Vex gloves protected adequately against undiluted formulation for about 2.7h, whereas they provided protection for nearly 8h when the formulation was diluted with water to the highest concentration for field application. In contrast, the disposable Safeskin gloves did not protect at all for the undiluted formulation, but did for 200 min when the formulation was diluted with water to the highest concentration for spraying.


Assuntos
Cicloexanos/análise , Cicloexanos/química , Luvas Protetoras , Nitrilas/análise , Cromatografia Gasosa , Substâncias Perigosas , Espectrometria de Massas , Modelos Estatísticos , Risco , Espectrofotometria Infravermelho , Espectroscopia de Infravermelho com Transformada de Fourier , Fatores de Tempo
17.
J Hazard Mater ; 137(2): 709-15, 2006 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-16650529

RESUMO

The aim of the present study was to quantify the permeation parameters of a complex water-insoluble straight oil metalworking fluid (MWF) of low volatility through nitrile gloves. The permeation through a chemically protective and a disposable glove was investigated using the American Society for Testing and Materials (ASTM) F739-99a method with hexane as the collection medium. Analysis of collection side samples involved gas chromatography-mass spectrometry (GC-MS) and gravimetry. The detection breakthrough time for the chemically protective glove was >10 h. For the disposable glove, the detection breakthrough time was 0.7+/-0.3 h, the lag time was 1.6+/-0.1 h, the diffusion coefficient was (3.7+/-0.3)x10(-9) cm2/min, and the steady state permeation rate was 3.5+/-2.2 microg/cm2/min. The disposable nitrile glove can be worn for about 30 min for incidental contact with straight oil MWFs without known carcinogens. The chemically protective nitrile glove should be worn otherwise. The chromatogram for the permeate differed from that of the original MWF, resulting from the faster permeation of lower molecular weight congeners. The combination of chromatography and gravimetry allowed quantifying the permeation parameters of complex water-insoluble non-volatile mixtures.


Assuntos
Luvas Protetoras , Óleo Mineral/química , Nitrilas/química , Óleos de Plantas/química , Cromatografia Gasosa-Espectrometria de Massas , Permeabilidade
18.
Appl Spectrosc ; 59(6): 724-31, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16053538

RESUMO

This study developed a method to produce uniform captan surface films on a disposable nitrile glove for quantitation with a portable attenuated total reflection Fourier transform infrared (ATR-FTIR) spectrometer. A permeation test was performed using aqueous captan formulation. Uniform captan surface films were produced using solvent casting with 2-propanol and a 25 mm filter holder connected to a vacuum manifold to control solvent evaporation. The coefficient of variation of the reflectance at 1735 +/- 5 cm(-1) was minimized by selection of the optimum solvent volume, airflow rate, and evaporation time. At room temperature, the lower to upper quantifiable limits were 0.31-20.7 microg/cm2 (r = 0.9967; p < or = 0.05) for the outer glove surface and 0.55-17.5 microg/cm2 (r = 0.9409; p < or = 0.05) for the inner surface. Relative humidity and temperature did not affect the uncoated gloves at the wavelength of captan analysis. Glove screening using ATR-FTIR was necessary as a control for between-glove variation. Captan permeation, after 8 hours exposure to an aqueous concentration of 217 mg/mL of Captan 50-WP, was detected at 0.8 +/- 0.3 microg/cm2 on the inner glove surface. ATR-FTIR can detect captan permeation and can determine the protectiveness of this glove in the field.


Assuntos
Algoritmos , Captana/análise , Materiais Revestidos Biocompatíveis/análise , Análise de Falha de Equipamento/métodos , Luvas Protetoras , Nitrilas/análise , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Captana/química , Materiais Revestidos Biocompatíveis/química , Teste de Materiais , Nitrilas/química , Permeabilidade
19.
J Hazard Mater ; 124(1-3): 81-7, 2005 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-15982807

RESUMO

Telone is a potent fumigant that is based on the chlorinated unsaturated hydrocarbon, 1,3-dichloropropene (1,3-DCP). It is often applied without dilution and so poses severe inhalation and air pollution threats. Urinary metabolites of 1,3-DCP have been detected after Telone skin exposure, so that preventing dermal exposure is also important. The objective of the study was to assess if nitrile and multi-layer ("laminated") gloves provide adequate protection against Telone EC formulation. To accomplish this, disposable (Safeskin) and chemically resistant (Sol-Vex) nitrile and laminated (Barrier mark and Silver Shield) glove materials were challenged by Telone EC with hexane liquid collection in an ASTM-type I-PTC-600 permeation cell. Analyses of cis- and trans-1,3-DCP in the collection fluid at specified times were performed on a moderately polar capillary column by gas chromatography-electron capture detection. Telone EC caused microholes in both nitrile materials, though the chemically protective material was degraded slower than the disposable nitrile. The laminated gloves offered limited protection. Silver Shield protected best because 1.5-2.3 mg 1,3-DCP permeated by 8 h relative to 2.5-7.6 mg for Barrier, implying about 2.5 times more protection for 8 h. Even for Silver Shield, the extent of protection was inadequate as illustrated by a risk assessment of the skin exposure situation. The normalized breakthrough times for both types of laminated gloves varied between 27 and 60 min. It is recommended that Viton gloves still be worn for protection.


Assuntos
Compostos Alílicos/química , Luvas Protetoras , Animais , Modelos Animais de Doenças , Humanos , Hidrocarbonetos Clorados , Raios Infravermelhos , Dose Letal Mediana , Camundongos , Modelos Químicos , Nitrilas/química , Permeabilidade , Ratos , Absorção Cutânea
20.
Mutat Res ; 563(1): 13-24, 2004 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-15324745

RESUMO

Formaldehyde (FA) is a mutagen that, at high concentrations and long durations, has been reported to cause nasal cancer in rats and in some humans. The level of FA-induced modified DNA in nasal cells should serve as a biomarker of FA exposure and effect. In the present study, a high-performance liquid chromatography (HPLC)-ultraviolet (UV) method at 254 nm was developed and optimized to detect and quantify hydroxymethyldeoxynucleosides after the isolated DNA in exposed human nasal epithelial cells (HNEC) was enzymically digested. Normal and modified deoxynucleosides were successfully resolved from one another and from tissue and enzyme blank interferences. The viability of HNEC exposed to FA in solution for 24 h decreased, and there was a linear dose response between % nonviability and FA dose from 10 to 500 microg/mL. Amounts of 18.0 +/- 1.5 pmol N6-dA and 12.0 +/- 1.2 pmol N2-dG derivatives were determined in a 10 microL injection after 1.4 x 10(7) HNEC (106 microg DNA) were exposed to 500 microg/mL in solution. The respective tissue concentrations in pmol hydroxymethyldeoxynucleoside/mg DNA were 170 +/- 14 and 113 +/- 11. The lower quantifiable limits were about 97 and 88 pmol/mg DNA, respectively. Diffusive exposure of HNEC to air FA up to 100 ppm (v/v) for 24 h did not produce quantifiable hydroxymethylnucleosides. FA-modified deoxynucleosides may be useful biomarkers for FA exposure in biological monitoring samples taken by nasal lavage or brush biopsy.


Assuntos
Adutos de DNA/análise , Fixadores/metabolismo , Formaldeído/metabolismo , Mutagênicos/metabolismo , Mucosa Nasal/metabolismo , Animais , Biomarcadores , Sobrevivência Celular , Células Cultivadas , Cromatografia Líquida de Alta Pressão/métodos , Exposição Ambiental , Fixadores/farmacologia , Formaldeído/farmacologia , Humanos , Masculino , Mucosa Nasal/citologia , Mucosa Nasal/efeitos dos fármacos , Neoplasias Nasais/induzido quimicamente , Neoplasias Nasais/genética , Ratos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa