Codas ; 35(1): e20210214, 2022.
Artigo em Português, Inglês | MEDLINE | ID: mdl-36259820

RESUMO

PURPOSE: To develop the Videokymographic Index of Glottic Function (VIGF), a composite indicator from digital videokymography parameters, captured by high-speed videolaryngoscopy exams of women with and without laryngeal alterations of behavioral etiology. METHODS: The sample consisted of 92 women aged between 18 and 45 years. Fifty-five (55) women with behavioral dysphonia, presenting with laryngeal and voice alterations, and thirty-seven (37) women without any laryngeal and voice alterations. Voice evaluation was performed by consensus via an auditory-perceptual analysis of the sustained vowel /a/ at a habitual pitch and loudness. Voice classification was obtained by means of a general degree of dysphonia, where G0 indicated neutral voice quality and G1 to G3 indicated altered voice quality. Laryngeal images were captured via digital videokymography analysis of a sustained vowel /i/ at a habitual pitch and loudness. The VIGF was based on the midpoint of the glottal region for analysis. Logistic regression was performed using the MINITAB 19 program. RESULTS: Logistic regression was composed of two stages: Stage 1 consisted of the analysis of all variables, where the maximum opening and closed quotient variables showed statistical significance (p-value <0.05) and the model was well adjusted according to the Hosmer-Lemeshow test (p-value=0.794). Stage 2 consisted of the re-analysis of the selected variables, also showing a well-adjusted model (p-value=0.198). The VIGF was defined as follows: VIGF=e^(8.1318-0.2941AbMax-0.0703FechGlo)/1+e^(8.1318-0.2941AbMax-0.0703FechGlo). CONCLUSION: The VIGF demonstrated a cut-off value equal to 0.71. The probability of success was 81.5%, sensitivity 76.4%, and specificity 89.2%.


OBJETIVO: Elaborar um indicador composto denominado Índice Videoquimográfico da Função Glótica ­ IVFG, a partir de parâmetros da videoquimografia digital, captados pelo exame de videolaringoscopia de alta velocidade de mulheres sem e com alterações laríngeas de etiologia comportamental. MÉTODO: A amostra foi composta por 92 mulheres, destas 55 apresentaram disfonia comportamental, com presença de alterações laríngeas e vocais, e 37 mulheres sem alterações laríngeas e vocais, entre 18 a 45 anos. A avaliação vocal foi realizada por consenso pela análise perceptivo-auditiva da vogal /a/ em frequência e intensidade habituais, e classificação através do grau geral da disfonia, onde G0 indicou qualidade vocal neutra e G1 a 3 qualidade vocal alterada. As imagens laríngeas foram obtidas pela gravação da emissão da vogal /i/, em frequência e intensidade habituais para análise da videoquimografia digital. A construção do IVFG se deu pela escolha do ponto médio da glote para análise e, elaboração foi realizada regressão logística pelo programa MINITAB 19. RESULTADOS: A regressão logística contou com duas etapas, sendo que a etapa 1 constou da análise de todas as variáveis, onde as variáveis abertura máxima e fechamento glótico apresentaram significância estatística (p-valor <0.05) e o modelo se encontrou bem ajustado de acordo com o teste de Hosmer-Lemeshow (p-valor=0,794); na etapa 2, as variáveis selecionadas foram novamente analisadas e o modelo também se mostrou bem ajustado (p-valor=0,198). O IVFG foi definido por IVFG=e


Assuntos
Disfonia , Laringe , Voz , Feminino , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Qualidade da Voz , Rouquidão
2.
J Voice ; 2021 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-34702611

RESUMO

PURPOSE: To investigate the effects of auditory training with synthesized voices on intra- and inter-rater agreement of the auditory-perceptual voice analysis of roughness and breathiness. METHODS: This was an experimental study consisting of four auditory training sessions. The sample consisted of twenty raters, students from a Speech-Language Pathology course, who had previous experience with auditory-perceptual assessment. The raters participated in the four training sessions with a seven-day break in between sessions. Each training consisted of three tasks: 1) Pre-training activity: Participants were asked to rate 20 natural voices, normal and dysphonic, from zero to three, according to the parameters of roughness and breathiness; 2) Training activity: Synthesized voice anchor stimuli were presented, and participants were asked to rate them from zero to three. Four stimuli were related to roughness and four to breathiness. Participants heard 20 voice stimuli and were instructed to pair the natural voice with the synthesized anchor stimulus that most resembled it; and 3) Post-training activity: the 20 voices from the pre-training activity were randomized and participants rated the same voices, without prior knowledge that these were repeated. Statistical analysis of data was performed using the AC2 test, to assess the extent of agreement between raters, and the Friedman test to compare the training sessions. A 5% significance level was considered. RESULTS: For the auditory-perceptual voice analysis of roughness, intra-rater agreement results ranged from 79% to 86% between the first and fourth auditory training session, with improvement in intra-rater agreement from the fourth session forward (P = 0.005). For the analysis of breathiness, results ranged from 88% to 92% between the first and fourth auditory training sessions, with improvement from the fourth session forward (P = 0.036). Inter-rater agreement results for the auditory-perceptual analysis of roughness ranged from 23% to 34%, and from 48% to 61% for breathiness, with no differences regarding training (P = 0.855). CONCLUSION: The auditory-perceptual breathiness parameter had a higher AC2 indicator compared to the roughness parameter, suggesting better agreement. The intra-rater agreement showed improvement starting from the fourth auditory training session for the assessment of roughness and breathiness. The auditory training program did not show a positive inter-rater agreement impact.

3.
CoDAS ; 35(1): e20210214, 2023. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1404346

RESUMO

RESUMO Objetivo Elaborar um indicador composto denominado Índice Videoquimográfico da Função Glótica - IVFG, a partir de parâmetros da videoquimografia digital, captados pelo exame de videolaringoscopia de alta velocidade de mulheres sem e com alterações laríngeas de etiologia comportamental. Método A amostra foi composta por 92 mulheres, destas 55 apresentaram disfonia comportamental, com presença de alterações laríngeas e vocais, e 37 mulheres sem alterações laríngeas e vocais, entre 18 a 45 anos. A avaliação vocal foi realizada por consenso pela análise perceptivo-auditiva da vogal /a/ em frequência e intensidade habituais, e classificação através do grau geral da disfonia, onde G0 indicou qualidade vocal neutra e G1 a 3 qualidade vocal alterada. As imagens laríngeas foram obtidas pela gravação da emissão da vogal /i/, em frequência e intensidade habituais para análise da videoquimografia digital. A construção do IVFG se deu pela escolha do ponto médio da glote para análise e, elaboração foi realizada regressão logística pelo programa MINITAB 19. Resultados A regressão logística contou com duas etapas, sendo que a etapa 1 constou da análise de todas as variáveis, onde as variáveis abertura máxima e fechamento glótico apresentaram significância estatística (p-valor <0.05) e o modelo se encontrou bem ajustado de acordo com o teste de Hosmer-Lemeshow (p-valor=0,794); na etapa 2, as variáveis selecionadas foram novamente analisadas e o modelo também se mostrou bem ajustado (p-valor=0,198). O IVFG foi definido por IVFG=e^(8,1318-0,2941AbMax-0,0703FechGlo)/1+e^(8,1318-0,2941AbMax-0,0703FechGlo). Conclusão O IVFG apresenta valor de corte igual a 0,71. A probabilidade de acerto é de 81,5%, sensibilidade 76,4%, especificidade de 89,2%.


ABSTRACT Purpose To develop the Videokymographic Index of Glottic Function (VIGF), a composite indicator from digital videokymography parameters, captured by high-speed videolaryngoscopy exams of women with and without laryngeal alterations of behavioral etiology. Methods The sample consisted of 92 women aged between 18 and 45 years. Fifty-five (55) women with behavioral dysphonia, presenting with laryngeal and voice alterations, and thirty-seven (37) women without any laryngeal and voice alterations. Voice evaluation was performed by consensus via an auditory-perceptual analysis of the sustained vowel /a/ at a habitual pitch and loudness. Voice classification was obtained by means of a general degree of dysphonia, where G0 indicated neutral voice quality and G1 to G3 indicated altered voice quality. Laryngeal images were captured via digital videokymography analysis of a sustained vowel /i/ at a habitual pitch and loudness. The VIGF was based on the midpoint of the glottal region for analysis. Logistic regression was performed using the MINITAB 19 program. Results Logistic regression was composed of two stages: Stage 1 consisted of the analysis of all variables, where the maximum opening and closed quotient variables showed statistical significance (p-value <0.05) and the model was well adjusted according to the Hosmer-Lemeshow test (p-value=0.794). Stage 2 consisted of the re-analysis of the selected variables, also showing a well-adjusted model (p-value=0.198). The VIGF was defined as follows: VIGF=e^(8.1318-0.2941AbMax-0.0703FechGlo)/1+e^(8.1318-0.2941AbMax-0.0703FechGlo). Conclusion The VIGF demonstrated a cut-off value equal to 0.71. The probability of success was 81.5%, sensitivity 76.4%, and specificity 89.2%.