Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Ayurveda Integr Med ; 15(2): 100903, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38574518

RESUMO

BACKGROUND: The pathogenesis of COVID-19 includes an integrated immune-inflammatory response. Modulation of host immune responses against the SARS-CoV-2 virus might be effective therapeutic management. Various Unani formulations have an immunomodulatory effect. OBJECTIVE: To explore the immunomodulatory effect and safety of Unani polyherbal drug (Tiryaq Wabai) in COVID-19 patients. MATERIALS AND METHODS: The current study was a randomized placebo-controlled clinical trial that included 92 mild to moderate COVID-19 patients randomized into two groups. The Unani formulation Tiryaq Wabai (2 gm orally once a day) was used as an intervention for 45 days, while the control group received a placebo. Both groups received standard care treatment. The primary outcome was 50% increment in absolute lymphocyte count (ALC). The secondary outcome was 50% increment in mean lymphocyte percentage, CD4 cells, and CD8 cell count. The mean increase in all the above parameters has also been studied. Relevant statistical tests were used to analyze the effect. RESULTS: A statistically significant improvement in a 50% increase in ALC (p-value, 0.004), lymphocyte percentage (p-value, 0.056), CD4 (p-value, 0.005), and CD8 cell count (p-value, 0.050) was reported. Also, a significant improvement in the mean value of the lymphocyte percentage (p-value 0.0007), ALC (p-value 0.0022), CD4 cell count (p-value 0.0025), and CD8 cell count (p-value 0.0093) was observed after the treatment. One adverse event of mild grade was reported in the placebo group. The analysis of safety parameters (LFT and KFT) was normal for both groups. CONCLUSION: In mild to moderate COVID-19 patients, Tiryaq Wabai effectively showed immunomodulatory activity by improving ALC count, lymphocyte percentage, CD4, and CD8 cell count.

2.
Bioelectrochemistry ; 157: 108671, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38401223

RESUMO

Herein, we fabricated an ultrasensitive electrochemical immunosensor for the quantitative detection of corticosteroid-binding globulin (CBG). CBG is a protein that regulates glucocorticoid levels and is an important biomarker for inflammation. A decrease in CBG levels is a key biomarker for inflammatory diseases, such as septic shock. To enhance the electrochemical performance and provide a large surface area for anti-CBG immobilization, we functionalized the glassy carbon electrode surface with AuNPs. Electrochemical characterization methods including cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to examine the construction of the fabricated immunosensor. The electrochemical signal demonstrated a remarkable sensitivity to the CBG antigen, with a detection range from 0.01 to 100 µg/mL and a limit of detection of 0.012 µg/mL, making it suitable for both clinical and research applications. This label-free immunosensor offers significant advantages, including high sensitivity, low detection limits and excellent selectivity, making it a promising tool for detecting CBG in complex biological samples. Its potential applications include early disease diagnosis, treatment monitoring and studying CBG-related physiological processes.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Carbono/química , Ouro/química , Transcortina , Nanopartículas Metálicas/química , Técnicas Biossensoriais/métodos , Imunoensaio , Técnicas Eletroquímicas/métodos , Eletrodos , Biomarcadores , Limite de Detecção
3.
Int J Biol Macromol ; 265(Pt 1): 130616, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38447842

RESUMO

The use of single-walled carbon nanotubes (SWCNTs) in biomedical applications is limited due to their inability to disperse in aqueous solutions. In this study, dispersed -COOH functionalized CNTs with N-succinylated chitosan (CS), greatly increasing the water solubility of CNTs and forming a uniformly dispersed nanocomposite solution of CNTs@CS. Coupling reagent EDC/NHS was used as a linker with the -COOH groups present on the N-succinylated chitosan which significantly improved the affinity of the CNTs for biomolecules. Myoglobin (Mb) is a promising biomarker for the precise assessment of cardiovascular risk, type 2 diabetes, metabolic syndrome, hypertension and several types of cancer. A high level of Mb can be used to diagnose the mentioned pathogenic diseases. The CNTs@CS-FET demonstrates superior sensing performance for Mb antigen fortified in buffer, with a wide linear range of 1 to 4000 ng/mL. The detection limit of the developed Mb immunosensor was estimated to be 4.2 ng/mL. The novel CNTs@CS-FET immunosensor demonstrates remarkable capability in detecting Mb without being affected by interferences from nonspecific antigens. Mb spiked serum showed a recovery rate of 100.262 to 118.55 % indicating great promise for Mb detection in clinical samples. The experimental results confirmed that the CNTs@CS-FET immunosensor had excellent selectivity, reproducibility and storage stability.


Assuntos
Técnicas Biossensoriais , Quitosana , Diabetes Mellitus Tipo 2 , Infarto do Miocárdio , Nanocompostos , Nanotubos de Carbono , Humanos , Mioglobina , Técnicas Biossensoriais/métodos , Reprodutibilidade dos Testes , Imunoensaio , Biomarcadores , Técnicas Eletroquímicas/métodos
4.
J Biomol Struct Dyn ; : 1-14, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38385500

RESUMO

The efficient detection of the foodborne pathogen Salmonella typhimurium has historically been hampered by the constraints of traditional methods, characterized by protracted culture periods and intricate DNA extraction processes for PCR. To address this, our research innovatively focuses on the crucial and relatively uncharted virulence factor, the Outer Membrane Protein D (OmpD) in Salmonella typhimurium. By harmoniously integrating the power of virtual screening and site-directed mutagenesis, we unveiled aptamers exhibiting marked specificity for OmpD. Among these, aptamer 7ZQS stands out with its heightened binding affinity. Capitalizing on this foundation, we further engineered a repertoire of mutant aptamers, wherein APT6 distinguished itself, reflecting unmatched stability and specificity. Our rigorous validation, underpinned by cutting-edge bioinformatics tools, amplifies the prowess of APT6 in discerning and binding OmpD across an array of Salmonella typhimurium strains. This study illuminates a transformative approach to the prompt and accurate detection of Salmonella typhimurium, potentially redefining boundaries in applied analytical chemistry and bolstering diagnostic precision across diverse research and clinical domains.Communicated by Ramaswamy H. Sarma.

5.
Int J Biol Macromol ; 273(Pt 2): 133083, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38866289

RESUMO

In recent decades, there has been a concerning and consistent rise in the incidence of cancer, posing a significant threat to human health and overall quality of life. The transferrin receptor (TfR) is one of the most crucial protein biomarkers observed to be overexpressed in various cancers. This study reports on the development of a novel voltammetric immunosensor for TfR detection. The electrochemical platform was made up of a glassy carbon electrode (GCE) functionalized with gold nanoparticles (AuNPs), on which anti-TfR was immobilized. The surface characteristics and electrochemical behaviors of the modified electrodes were comprehensively investigated through scanning electron microscopy, XPS, Raman spectroscopy FT-IR, electrochemical cyclic voltammetry and impedance spectroscopy. The developed immunosensor exhibited robust analytical performance with TfR fortified buffer solution, showing a linear range (LR) response from 0.01 to 3000 µg/mL, with a limit of detection (LOD) of 0.01 µg/mL and reproducibility (RSD <4 %). The fabricated sensor demonstrated high reproducibility and selectivity when subjected to testing with various types of interfering proteins. The immunosensor designed for TfR detection demonstrated several advantageous features, such as being cost-effective and requiring a small volume of test sample making it highly suitable for point-of-care applications.


Assuntos
Técnicas Biossensoriais , Carbono , Eletrodos , Ouro , Nanopartículas Metálicas , Receptores da Transferrina , Ouro/química , Nanopartículas Metálicas/química , Técnicas Biossensoriais/métodos , Carbono/química , Humanos , Imunoensaio/métodos , Limite de Detecção , Técnicas Eletroquímicas/métodos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa