Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Clin Diabetes ; 42(1): 116-124, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38230336

RESUMO

The t:slim X2 insulin pump with Control-IQ technology (Control-IQ) advanced hybrid closed-loop automated insulin delivery system was evaluated in this prospective single-arm trial. Thirty adults with type 2 diabetes using the Control-IQ system showed substantial glycemic improvement with no increase in hypoglycemia. Mean time in range (70-180 mg/dL) improved 15%, representing an increase of 3.6 hours/day, and mean glucose decreased by 22 mg/dL.

2.
N Engl J Med ; 381(18): 1707-1717, 2019 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-31618560

RESUMO

BACKGROUND: Closed-loop systems that automate insulin delivery may improve glycemic outcomes in patients with type 1 diabetes. METHODS: In this 6-month randomized, multicenter trial, patients with type 1 diabetes were assigned in a 2:1 ratio to receive treatment with a closed-loop system (closed-loop group) or a sensor-augmented pump (control group). The primary outcome was the percentage of time that the blood glucose level was within the target range of 70 to 180 mg per deciliter (3.9 to 10.0 mmol per liter), as measured by continuous glucose monitoring. RESULTS: A total of 168 patients underwent randomization; 112 were assigned to the closed-loop group, and 56 were assigned to the control group. The age range of the patients was 14 to 71 years, and the glycated hemoglobin level ranged from 5.4 to 10.6%. All 168 patients completed the trial. The mean (±SD) percentage of time that the glucose level was within the target range increased in the closed-loop group from 61±17% at baseline to 71±12% during the 6 months and remained unchanged at 59±14% in the control group (mean adjusted difference, 11 percentage points; 95% confidence interval [CI], 9 to 14; P<0.001). The results with regard to the main secondary outcomes (percentage of time that the glucose level was >180 mg per deciliter, mean glucose level, glycated hemoglobin level, and percentage of time that the glucose level was <70 mg per deciliter or <54 mg per deciliter [3.0 mmol per liter]) all met the prespecified hierarchical criterion for significance, favoring the closed-loop system. The mean difference (closed loop minus control) in the percentage of time that the blood glucose level was lower than 70 mg per deciliter was -0.88 percentage points (95% CI, -1.19 to -0.57; P<0.001). The mean adjusted difference in glycated hemoglobin level after 6 months was -0.33 percentage points (95% CI, -0.53 to -0.13; P = 0.001). In the closed-loop group, the median percentage of time that the system was in closed-loop mode was 90% over 6 months. No serious hypoglycemic events occurred in either group; one episode of diabetic ketoacidosis occurred in the closed-loop group. CONCLUSIONS: In this 6-month trial involving patients with type 1 diabetes, the use of a closed-loop system was associated with a greater percentage of time spent in a target glycemic range than the use of a sensor-augmented insulin pump. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases; iDCL ClinicalTrials.gov number, NCT03563313.).


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Pâncreas Artificial , Adolescente , Adulto , Idoso , Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Desenho de Equipamento , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes/efeitos adversos , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Masculino , Pessoa de Meia-Idade , Pâncreas Artificial/efeitos adversos , Adulto Jovem
3.
Pediatr Diabetes ; 19(3): 420-428, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29159870

RESUMO

OBJECTIVE: The primary objective of this trial was to evaluate the feasibility, safety, and efficacy of a predictive hyperglycemia and hypoglycemia minimization (PHHM) system vs predictive low glucose suspension (PLGS) alone in optimizing overnight glucose control in children 6 to 14 years old. RESEARCH DESIGN AND METHODS: Twenty-eight participants 6 to 14 years old with T1D duration ≥1 year with daily insulin therapy ≥12 months and on insulin pump therapy for ≥6 months were randomized per night into PHHM mode or PLGS-only mode for 42 nights. The primary outcome was percentage of time in sensor-measured range 70 to 180 mg/dL in the overnight period. RESULTS: The addition of automated insulin delivery with PHHM increased time in target range (70-180 mg/dL) from 66 ± 11% during PLGS nights to 76 ± 9% during PHHM nights (P<.001), without increasing hypoglycemia as measured by time below various thresholds. Average morning blood glucose improved from 176 ± 28 mg/dL following PLGS nights to 154 ± 19 mg/dL following PHHM nights (P<.001). CONCLUSIONS: The PHHM system was effective in optimizing overnight glycemic control, significantly increasing time in range, lowering mean glucose, and decreasing glycemic variability compared to PLGS alone in children 6 to 14 years old.


Assuntos
Diabetes Mellitus Tipo 1/sangue , Hiperglicemia/prevenção & controle , Hipoglicemia/prevenção & controle , Sistemas de Infusão de Insulina , Monitorização Ambulatorial/instrumentação , Adolescente , Glicemia , Criança , Alarmes Clínicos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Método Duplo-Cego , Estudos de Viabilidade , Feminino , Humanos , Masculino
4.
Pediatr Diabetes ; 18(6): 422-427, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27402452

RESUMO

OBJECTIVE: To compare the frequency of elevated morning blood ketone levels according to age in 4-14 year olds with type 1 diabetes following overnight use of an automated low glucose insulin suspension system, or following control nights when the system was not used. RESEARCH DESIGN AND METHODS: For 28 children ages 4-9 years and 54 youth ages 10-14 years, elevation of morning blood ketone levels was assessed using the Precision Xtra Ketone meter following 1155 and 2345 nights, respectively. Repeated measures logistic regression models were used to compare age groups for blood ketone level elevation following control nights (system not activated) and following intervention nights with and without insulin suspension. RESULTS: Elevated morning blood ketones (≥0.6 mmol/L) were present following 10% of 580 control nights in the 4-9 year olds compared with 2% of 1162 control nights in 10-14 year olds (P < 0.001). Likewise, the frequency was greater following intervention nights in the younger age group (13% of 575 nights vs 2% of 1183 nights, P < 0.001). A longer duration of pump suspension resulted in a higher percentage of mornings with elevated blood ketones in the younger age group (P = 0.002), but not in the older age group (P = 0.63). The presence of elevated morning ketone levels did not progress to ketoacidosis in any subject. CONCLUSIONS: Elevated morning blood ketones are more common in younger children with type 1 diabetes with or without nocturnal insulin suspension. Care providers need to be aware of the differences in ketogenesis in younger age children relative to various clinical situations.


Assuntos
Diabetes Mellitus Tipo 1/sangue , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Cetonas/sangue , Adolescente , Criança , Pré-Escolar , Diabetes Mellitus Tipo 1/tratamento farmacológico , Feminino , Humanos , Masculino
5.
Pediatr Diabetes ; 15(8): 564-72, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24494980

RESUMO

Insulin delivery via injection and continuous subcutaneous insulin infusion (CSII) via insulin pump were compared in a cross-sectional study (n = 669) and retrospective longitudinal study (n = 1904) of young children (<6 yr) with type 1 diabetes (T1D) participating in the T1D Exchange clinic registry. Use of CSII correlated with longer T1D duration (p < 0.001), higher parental education (p < 0.001), and annual household income (p < 0.006) but not with race/ethnicity. Wide variation in pump use was observed among T1D Exchange centers even after adjusting for these factors, suggesting that prescriber preference is a substantial determinant of CSII use. Hemoglobin A1c (HbA1c) was lower in pump vs. injection users (7.9 vs. 8.5%, adjusted p < 0.001) in the cross-sectional study. In the longitudinal study, HbA1c decreased after initiation of CSII by 0.2%, on average (p < 0.001). Frequency of a severe hypoglycemia (SH) event did not differ in pump vs. injection users (p = 0.2). Frequency of ≥1 parent-reported diabetic ketoacidosis (DKA) event in the prior year was greater in pump users than injection users (10 vs. 8%, p = 0.04). No differences between pump and injection users were observed for clinic-reported DKA events. Children below 6 yr have many unique metabolic characteristics, feeding behaviors, and care needs compared with older children and adolescents. These data support the use of insulin pumps in this youngest age group, and suggest that metabolic control may be improved without increasing the frequency of SH, but care should be taken as to the possibly increased risk of DKA.


Assuntos
Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/metabolismo , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Criança , Pré-Escolar , Estudos Transversais , Diabetes Mellitus Tipo 1/epidemiologia , Feminino , Humanos , Lactente , Injeções Subcutâneas , Sistemas de Infusão de Insulina/estatística & dados numéricos , Estudos Longitudinais , Masculino , Sistema de Registros/estatística & dados numéricos , Estudos Retrospectivos
6.
Diabetes Technol Ther ; 26(3): 151-155, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37870460

RESUMO

Objective: To evaluate the relationship between continuous glucose monitoring (CGM)-measured time-in-range 70-180 mg/dL (TIR) and time-in-tight-range 70-140 mg/dL (TITR). Methods: TIR and TITR were calculated from CGM data collected using blinded or unblinded Dexcom sensors from 9 studies with 912 participants with type 1 diabetes (T1D) and 2 studies with 184 participants with type 2 diabetes (T2D). The TIR-TITR relationship was assessed overall and stratified by coefficient of variation (CV) and by time below range <70 mg/dL (TBR). Results: The correlation between TIR and TITR was 0.94. TITR was higher for a given TIR for T2D compared with T1D. However, after adjusting for the differences in CV or TBR, both of which were higher with T1D than T2D, the differences were minimized. The TIR-TITR relationship was nonlinear, with a higher ratio of TITR:TIR observed as TIR increased ranging from 0.42 when TIR was 20% to 0.66 when TIR was 80%. Similarly, as TITR increased, the ratio of TIR:TITR decreased, varying from 2.6 with TITR of 10% to 1.3 for TITR of 70%. The TIR-TITR relationship varied according to CV and TBR, such that the higher the CV or higher the amount of TBR the greater was TITR for a given TIR. Conclusions: TIR and TITR are highly correlated, although the relationship is nonlinear. With knowledge of TIR, TITR can be estimated with reasonable precision.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Glicemia , Automonitorização da Glicemia , Monitoramento Contínuo da Glicose
7.
Ophthalmology ; 120(12): 2428-2435, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24246826

RESUMO

OBJECTIVE: To examine the effect of donor age and other perioperative factors on long-term endothelial cell loss after penetrating keratoplasty (PKP). DESIGN: Multicenter, prospective, double-masked clinical trial. PARTICIPANTS: We included 176 participants from the Cornea Donor Study cohort who had not experienced graft failure ≥ 10 years after PKP for a moderate risk condition (principally Fuchs' dystrophy or pseudophakic/aphakic corneal edema). METHODS: Corneas from donors 12 to 75 years old were assigned to participants using a randomized approach, without respect to recipient factors. Surgery and postoperative care were performed according to the surgeons' usual routines. Images of the central endothelium were obtained preoperatively and at intervals for 10 years postoperatively. Images were analyzed by a central image analysis reading center to determine endothelial cell density (ECD). MAIN OUTCOME MEASURES: Endothelial cell density at 10 years. RESULTS: Among study participants with a clear graft at 10 years, the 125 who received a cornea from a donor 12 to 65 years old experienced a median cell loss of 76%, resulting in a 10-year median ECD of 628 cells/mm(2) (interquartile range [IQR], 522-850 cells/mm(2)), whereas the 51 who received a cornea from a donor 66 to 75 years old experienced a cell loss of 79%, resulting in a median 10-year ECD of 550 cells/mm(2) (IQR, 483-694 cells/mm(2); P adjusted for baseline ECD = 0.03). In addition to younger donor age, higher ECD values were significantly associated with higher baseline ECD (P<0.001) and larger donor tissue size (P<0.001). Forty-two of the 176 participants (24%) had an ECD of <500 cells/mm(2) at 10 years and only 24 (14%) had an ECD of >1000 cells/mm(2). CONCLUSIONS: Substantial cell loss occurs in eyes with a clear graft 10 years after PKP, with the rate of cell loss being slightly greater with older donor age. Greater preoperative ECD and larger donor tissue size are associated with higher ECD at 10 years.


Assuntos
Envelhecimento/patologia , Perda de Células Endoteliais da Córnea/etiologia , Distrofia Endotelial de Fuchs/cirurgia , Sobrevivência de Enxerto/fisiologia , Ceratoplastia Penetrante , Complicações Pós-Operatórias , Doadores de Tecidos , Adolescente , Adulto , Idoso , Contagem de Células , Criança , Edema da Córnea/fisiopatologia , Edema da Córnea/cirurgia , Perda de Células Endoteliais da Córnea/diagnóstico , Perda de Células Endoteliais da Córnea/fisiopatologia , Método Duplo-Cego , Endotélio Corneano/patologia , Bancos de Olhos , Feminino , Distrofia Endotelial de Fuchs/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo , Adulto Jovem
8.
Ophthalmology ; 120(12): 2419-2427, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24246825

RESUMO

OBJECTIVE: To determine whether the 10-year success rate of penetrating keratoplasty for corneal endothelial disorders is associated with donor age. DESIGN: Multicenter, prospective, double-masked clinical trial. PARTICIPANTS: A total of 1090 participants undergoing penetrating keratoplasty at 80 sites for Fuchs' dystrophy (62%), pseudophakic/aphakic corneal edema (34%), or another corneal endothelial disorder (4%) and followed for up to 12 years. METHODS: Forty-three eye banks provided corneas from donors aged 12 to 75 years, using a randomized approach to assign donor corneas to study participants without respect to recipient factors. Surgery and postoperative care were performed according to the surgeons' usual routines. MAIN OUTCOME MEASURES: Graft failure defined as a regraft or, in the absence of a regraft, a cloudy cornea that was sufficiently opaque to compromise vision for 3 consecutive months. RESULTS: In the primary analysis, the 10-year success rate was 77% for 707 corneas from donors aged 12 to 65 years compared with 71% for 383 donors aged 66 to 75 years (difference, +6%; 95% confidence interval, -1 to +12; P = 0.11). When analyzed as a continuous variable, higher donor age was associated with lower graft success beyond the first 5 years (P<0.001). Exploring this association further, we observed that the 10-year success rate was relatively constant for donors aged 34 to 71 years (75%). The success rate was higher for 80 donors aged 12 to 33 years (96%) and lower for 130 donors aged 72 to 75 years (62%). The relative decrease in the success rate with donor ages 72 to 75 years was not observed until after year 6. CONCLUSIONS: Although the primary analysis did not show a significant difference in 10-year success rates comparing donor ages 12 to 65 years and 66 to 75 years, there was evidence of a donor age effect at the extremes of the age range. Because we observed a fairly constant 10-year success rate for donors aged 34 to 71 years, which account for approximately 75% of corneas in the United States available for transplant, the Cornea Donor Study results indicate that donor age is not an important factor in most penetrating keratoplasties for endothelial disease.


Assuntos
Envelhecimento/fisiologia , Distrofia Endotelial de Fuchs/cirurgia , Sobrevivência de Enxerto/fisiologia , Ceratoplastia Penetrante , Doadores de Tecidos , Adolescente , Adulto , Fatores Etários , Idoso , Criança , Edema da Córnea/fisiopatologia , Edema da Córnea/cirurgia , Método Duplo-Cego , Bancos de Olhos , Feminino , Seguimentos , Distrofia Endotelial de Fuchs/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Adulto Jovem
9.
J Vasc Surg ; 57(2): 451-8, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23244784

RESUMO

OBJECTIVE: The treatment goals of access-related hand ischemia (ARHI) are to reverse symptoms and salvage the access. Many procedures have been described, but the optimal treatment strategy remains unresolved. In an effort to guide clinical decision making, this study was undertaken to document our outcomes for distal revascularization and interval ligation (DRIL) and to identify predictors of bypass patency and patient mortality. METHODS: A retrospective review was performed of all patients who underwent DRIL at the University of Florida from 2002 to 2011. Diagnosis of ARHI was based primarily upon clinical symptoms with noninvasive studies used to corroborate in equivocal cases. Patient demographics, procedure-outcome variables, and reinterventions were recorded. Bypass patency and mortality were estimated using cumulative incidence and Kaplan-Meier methodology, respectively. Cumulative incidence and Cox regression analysis were performed to determine predictors of bypass patency and mortality, respectively. RESULTS: A total of 134 DRILs were performed in 126 patients (mean [standard deviation] age, 57 [12] years) following brachial artery-based access. The postoperative complication rate was 27% (19% wound), and 30-day mortality was 2%. The wrist-brachial index and digital brachial index increased 0.31 (0.25) and 0.25 (0.29), respectively. Symptoms resolved in 82% of patients, and 85% continued to use their access. Cumulative incidences (± standard error of the mean) of loss of primary and primary-assisted patency rates were 5% ± 2% and 4% ± 2% at 1 year and 22% ± 5% and 18% ± 5% at 5 years, respectively, with mean follow-up of 14.8 months. Univariate predictors of primary patency failure were DRIL complications (odds ratio [OR], 3.3; 95% confidence interval [CI], 1.2-8.9; P = .02), configuration other than brachiobasilic/brachiocephalic autogenous access (OR, 3.4; 95% CI, 1.4-8.3; P = .009), and two or more prior access attempts (OR, 4.1; 95% CI, 1.6-10.4; P = .004). Brachiocephalic access configuration (OR, 0.2; 95% CI, 0.04-0.8; P = .02) and autogenous vein conduit (OR, 0.2; 95% CI, 0.06-0.58; P = .004) were predictors of improved bypass patency. All-cause mortality was 28% and 79% at 1 and 5 years, respectively. Multivariable predictors of mortality were age >40 (hazard ratio [HR], 8.3; 95% CI, 2.5-33.3; P = .0004), grade 3 ischemia (HR, 2.6; 95% CI, 1.5-4.6; P = .0008), complication from DRIL (HR, 2.4; 95% CI, 1.3-4.5; P = .004), and smoking history (HR, 2.2; 95% CI, 1.3-4; P = .007). Patients with no prior access attempts had lower predicted mortality (HR, 0.5; 95% CI, 0.3-0.9; P = .02). CONCLUSIONS: The DRIL procedure effectively improves distal perfusion and reverses the symptoms of ARHI while salvaging the access, but the long-term survival of these patients is poor. Given the poor survival, preoperative risk stratification is critical. Patients at high risk for DRIL failure and mortality may be best served with alternate remedial procedures.


Assuntos
Derivação Arteriovenosa Cirúrgica/efeitos adversos , Oclusão de Enxerto Vascular/cirurgia , Mãos/irrigação sanguínea , Isquemia/cirurgia , Diálise Renal , Grau de Desobstrução Vascular , Idoso , Derivação Arteriovenosa Cirúrgica/mortalidade , Feminino , Florida , Oclusão de Enxerto Vascular/mortalidade , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Incidência , Isquemia/mortalidade , Isquemia/fisiopatologia , Estimativa de Kaplan-Meier , Ligadura , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Modelos de Riscos Proporcionais , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
Diabetes Technol Ther ; 25(3): 157-160, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36576488

RESUMO

Objective: While it is recognized that there is a strong relationship between the amount of time glucose levels are <70 mg/dL (T<70) and the amount of time <54 mg/dL (T<54), the association has not been well quantified. Methods: Datasets with Dexcom continuous glucose monitoring (CGM) data from nine type 1 diabetes randomized trials were pooled to evaluate the relationship between CGM-measured T<70 and T<54. Penalized B-spline regression lines were fitted to assess the relationship between T<70 and T<54 for blinded CGM use, unblinded CGM use without an automated insulin delivery (AID) system, and unblinded CGM use with an AID system. Results: For blinded data, the T<54 : T<70 ratio varied from 19% when the amount of T<70 was <1% to 44% when the amount of T<70 was ≥7% whereas for unblinded data the ratio varied from 15% to 42%, respectively. When T<70 was 4%, the predicted T<54 was 1.18%, 0.94%, and 0.91% for the blinded, unblinded, and AID data, respectively (P<0.001 comparing blinded versus unblinded and AID). Conclusions: The T<54 : T<70 ratio increases with greater T<70, and the ratio generally is higher with blinded than unblinded CGM data, with the latter appearing to be similar to AID system data. The finding of greater T<54 for a given T<70 with blinded CGM data is presumed to be due to an action being taken by the unblinded CGM user and/or by the AID system to minimize hypoglycemia which will have the effect of reducing the amount of T<54.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Humanos , Glicemia , Automonitorização da Glicemia
11.
J Diabetes Sci Technol ; 17(4): 935-942, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35473359

RESUMO

BACKGROUND: We investigated the potential benefits of automated insulin delivery (AID) among individuals with type 1 diabetes (T1D) in sub-populations of baseline device use determined by continuous glucose monitor (CGM) use status and insulin delivery via multiple daily injections (MDI) or insulin pump. MATERIALS AND METHODS: In a six-month randomized, multicenter trial, 168 individuals were assigned to closed-loop control (CLC, Control-IQ, Tandem Diabetes Care), or sensor-augmented pump (SAP) therapy. The trial included a two- to eight-week run-in phase to train participants on study devices. The participants were stratified into four subgroups: insulin pump and CGM (pump+CGM), pump-only, MDI and CGM (MDI+CGM), and MDI users without CGM (MDI-only) users. We compared glycemic outcomes among four subgroups. RESULTS: At baseline, 61% were pump+CGM users, 18% pump-only users, 10% MDI+CGM users, and 11% MDI-only users. Mean time in range 70-180 mg/dL (TIR) improved from baseline in the four subgroups using CLC: pump+CGM, 62% to 73%; pump-only, 61% to 70%; MDI+CGM, 54% to 68%; and MDI-only, 61% to 69%. The reduction in time below 70 mg/dL from baseline was comparable among the four subgroups. No interaction effect was detected with baseline device use for TIR (P = .67) or time below (P = .77). On the System Usability Questionnaire, scores were high at 26 weeks for all subgroups: pump+CGM: 87.2 ± 12.1, pump-only: 89.4 ± 8.2, MDI+CGM 87.2 ± 9.3, MDI: 78.1 ± 15. CONCLUSIONS: There was a consistent benefit in patients with T1D when using CLC, regardless of baseline insulin delivery modality or CGM use. These data suggest that this CLC system can be considered across a wide range of patients.


Assuntos
Diabetes Mellitus Tipo 1 , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes , Automonitorização da Glicemia , Glicemia , Insulina , Insulina Regular Humana/uso terapêutico , Sistemas de Infusão de Insulina
12.
JAMA Netw Open ; 6(10): e2336876, 2023 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-37792375

RESUMO

Importance: As the number of patients with diabetes continues to increase in the United States, novel approaches to clinical care access should be considered to meet the care needs for this population, including support for diabetes-related technology. Objective: To evaluate a virtual clinic to facilitate comprehensive diabetes care, support continuous glucose monitoring (CGM) integration into diabetes self-management, and provide behavioral health support for diabetes-related issues. Design, Setting, and Participants: This cohort study was a prospective, single-arm, remote study involving adult participants with type 1 or type 2 diabetes who were referred through community resources. The study was conducted virtually from August 24, 2020, to May 26, 2022; analysis was conducted at the clinical coordinating center. Intervention: Training and education led by a Certified Diabetes Care and Education Specialist for CGM use through a virtual endocrinology clinic structure, which included endocrinologists and behavioral health team members. Main Outcomes and Measures: Main outcomes included CGM-measured mean glucose level, coefficient of variation, and time in range (TIR) of 70 to 180 mg/dL, time with values greater than 180 mg/dL or 250 mg/dL, and time with values less than 70 mg/dL or 54 mg/dL. Hemoglobin A1c was measured at baseline and at 12 and 24 weeks. Results: Among the 234 participants, 160 had type 1 diabetes and 74 had type 2 diabetes. The mean (SD) age was 47 (14) years, 123 (53%) were female, and median diabetes duration was 20 years. Median (IQR) CGM use over 6 months was 96% (91%-98%) for participants with type 1 diabetes and 94% (85%-97%) for those with type 2 diabetes. Mean (SD) hemoglobin A1c (HbA1c) in those with type 1 diabetes decreased from 7.8% (1.6%) at baseline to 7.1% (1.0%) at 3 months and 7.1% (1.0%) at 6 months (mean change from baseline to 6 months, -0.6%, 95% CI, -0.8% to -0.5%; P < .001), with an 11% mean TIR increase over 6 months (95% CI, 9% to 14%; P < .001). Mean HbA1c in participants with type 2 diabetes decreased from 8.1% (1.7%) at baseline to 7.1% (1.0%) at 3 months and 7.1% (0.9%) at 6 months (mean change from baseline to 6 months, -1.0%; 95% CI, -1.4% to -0.7%; P < .001), with an 18% TIR increase over 6 months (95% CI, 13% to 24%; P < .001). In participants with type 1 diabetes, mean percentage of time with values less than 70 mg/dL and less than 54 mg/dL decreased over 6 months by 0.8% (95% CI, -1.2% to -0.4%; P = .001) and by 0.3% (95% CI, -0.5% to -0.2%, P < .001), respectively. In the type 2 diabetes group, hypoglycemia was rare (mean [SD] percentage of time <70 mg/dL, 0.5% [0.6%]; and <54 mg/dL, 0.07% [0.14%], over 6 months). Conclusions and Relevance: Results from this cohort study demonstrated clinical benefits associated with implementation of a comprehensive care model that included diabetes education. This model of care has potential to reach a large portion of patients with diabetes, facilitate diabetes technology adoption, and improve glucose control.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Autogestão , Telemedicina , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Masculino , Diabetes Mellitus Tipo 1/terapia , Hemoglobinas Glicadas , Diabetes Mellitus Tipo 2/epidemiologia , Diabetes Mellitus Tipo 2/terapia , Glicemia/análise , Automonitorização da Glicemia , Estudos de Coortes , Estudos Prospectivos
13.
Circulation ; 123(25): 2938-45, 2011 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-21646499

RESUMO

BACKGROUND: In this study, we report the late outcomes of a large, decade-long single-center thoracic endovascular aortic repair experience. METHODS AND RESULTS: A prospectively maintained registry and the electronic medical records of 400 consecutive thoracic endovascular aortic repair performed at a tertiary care center were reviewed. The distribution of pathologies treated included aneurysms (198, 49%), dissections (100, 25%), penetrating ulcers (54, 14%), traumatic transections (25, 6%), and other pathologies (23, 6%). Spinal drains were placed prophylactically in 127 cases (32%) of planned extended aortic coverage. There were no acute surgical conversions. Adjunctive surgical procedures were performed on 94 patients (24%). Subclavian revascularizations were performed selectively in only 15% of zone 0 to 2 deployments. The median length of stay was 5 days (limits, 1 and 79 days). Overall 30-day mortality was 6.5% (elective, 2.6%; urgent, 9.5%; and emergent, 20%). Permanent spinal cord ischemia occurred in 4.5% and stroke in 3%. Kaplan-Meier estimates of survival were 82%, 76%, 68%, and 60% and freedom from secondary intervention was 90%, 86%, 81%, and 78% at 6, 12, 24, and 36 months, respectively. Risk factors for mortality included stroke, urgent/emergent repair, age ≥80 years, general anesthesia, and dissection pathology. CONCLUSIONS: Thoracic endovascular aortic repair may be used to treat a variety of thoracic aortic pathologies with a very low risk of intraoperative conversion. Overall rates of mortality and neurological complications were relatively low but significantly increased in emergent repairs. There appeared to be a substantial number of late deaths, which may represent a combination of poor patient selection and treatment failures.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Procedimentos Cirúrgicos Vasculares , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/lesões , Aorta Torácica/patologia , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/cirurgia , Doenças da Aorta/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Úlcera/mortalidade , Úlcera/cirurgia , Adulto Jovem
14.
Diabetes Technol Ther ; 24(12): 868-872, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35920822

RESUMO

Objective: To determine the optimal duration of a run-in period for initiation of real-time continuous glucose monitoring (CGM) before the start of a randomized controlled trial (RCT) in type 1 diabetes (T1D) or type 2 diabetes (T2D). Methods: Data sets were pooled from 8 RCTs, which had a blinded CGM wear period followed by at least 3 months of unblinded CGM use. Across all participants, mean time in range 70-180 mg/dL (TIR) and mean time <54 mg/dL (T < 54) as well as other key CGM metrics were computed for the initial period of blinded CGM wear and from the subsequent 13 weeks of unblinded CGM use. Results: The analysis cohort included data from 485 participants: 348 with T1D and 137 with T2D, ranging in age from 2 to 82 years. Mean TIR was 49% with blinded CGM before initiation of unblinded CGM use, increased to 55% by the end of the first week of unblinded CGM use, and then showed little change through 13 weeks. Mean T < 54 decreased from 1.4% with blinded CGM to 0.8% 1 week and 0.6% 2 weeks after initiating unblinded CGM use, which matched the value in month 3. Similar results were obtained for mean glucose, time >180 mg/dL, time >250 mg/dL, and time <70 mg/dL, with the mean improvement in hyperglycemia metrics plateauing slightly faster than hypoglycemia metrics. Findings were largely similar for T1D and T2D. Conclusion: When initiating unblinded real-time CGM, improvement in key CGM metrics occurs rapidly, with maximal effect on the mean of each metric achieved within 1-2 weeks. For a randomized trial in which all participants will use real-time unblinded CGM for glucose monitoring, a run-in period should be implemented before collecting baseline data for participants who are not CGM users. For such CGM-naive individuals, a 7- to 14-day acclimation period is sufficient followed by a 14-day period for collection of baseline unblinded CGM data.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Humanos , Pré-Escolar , Criança , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Diabetes Mellitus Tipo 1/tratamento farmacológico , Automonitorização da Glicemia/métodos , Glicemia , Glucose , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hemoglobinas Glicadas/análise , Hipoglicemiantes/uso terapêutico
15.
Diabetes Technol Ther ; 24(8): 588-591, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35020488

RESUMO

Using a closed-loop system significantly improves time in range (TIR) 70-180 mg/dL in patients with type 1 diabetes (T1D). In a 6-month RCT, 112 subjects were randomly assigned to closed-loop control (Tandem Control-IQ) after obtaining 2 weeks of baseline Continuous glucose monitoring (CGM) data from sensor-augmented pump therapy. We compared glycemic outcomes from baseline to end of study among subgroups classified by baseline HbA1c levels. All HbA1c subgroups showed an improvement in TIR due to reduction of both hyperglycemia and hypoglycemia. Those with HbA1c <6.5% improved mostly by reducing nocturnal hypoglycemia due to the automated basal insulin adjustments. Those with HbA1c ≥8.5% improved mostly by reducing daytime and nocturnal hyperglycemia due to both automated basal insulin adjustments and correction boluses during the day. There does not appear to be any reason to exclude individuals with T1D from automated insulin delivery based on their HbA1c. Clinical Trial Identifier: NCT03563313.


Assuntos
Diabetes Mellitus Tipo 1 , Hiperglicemia , Hipoglicemia , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Humanos , Hiperglicemia/tratamento farmacológico , Hiperglicemia/prevenção & controle , Hipoglicemia/induzido quimicamente , Hipoglicemia/tratamento farmacológico , Hipoglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina
16.
Diabetes Technol Ther ; 24(5): 357-361, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35099294

RESUMO

Objective: To analyze insulin delivery and glycemic metrics throughout the menstrual cycle for women with type 1 diabetes using closed loop control (CLC) insulin delivery. Methods: Menstruating women using a CLC system in a clinical trial were invited to record their menstrual cycles through a cycle-tracking application. Sixteen participants provided data for this secondary analysis over three or more complete cycles. Insulin delivery and continuous glucose monitoring (CGM) data were analyzed in relation to reported cycle phases. Results: Insulin delivery and CGM metrics remained consistent during cycle phases. Intraparticipant variability of CGM metrics and weight-based insulin delivery did not change through cycle phases. Conclusions: For this sample of menstruating women with type 1 diabetes using a CLC system, insulin delivery and glycemic metrics remained stable throughout menstrual cycle phases. Additional studies in this population are needed, particularly among women who report variable glycemic control during their cycles. Trial Registration: NCT03591354.


Assuntos
Diabetes Mellitus Tipo 1 , Glicemia/análise , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Feminino , Glucose , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico , Ciclo Menstrual
17.
Diabetes Technol Ther ; 24(9): 635-642, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35549708

RESUMO

Background: Automated insulin delivery (AID) systems have proven effective in increasing time-in-range during both clinical trials and real-world use. Further improvements in outcomes for single-hormone (insulin only) AID may be limited by suboptimal insulin delivery settings. Methods: Adults (≥18 years of age) with type 1 diabetes were randomized to either sensor-augmented pump (SAP) (inclusive of predictive low-glucose suspend) or adaptive zone model predictive control AID for 13 weeks, then crossed over to the other arm. Each week, the AID insulin delivery settings were sequentially and automatically updated by an adaptation system running on the study phone. Primary outcome was sensor glucose time-in-range 70-180 mg/dL, with noninferiority in percent time below 54 mg/dL as a hierarchical outcome. Results: Thirty-five participants completed the trial (mean age 39 ± 16 years, HbA1c at enrollment 6.9% ± 1.0%). Mean time-in-range 70-180 mg/dL was 66% with SAP versus 69% with AID (mean adjusted difference +2% [95% confidence interval: -1% to +6%], P = 0.22). Median time <70 mg/dL improved from 3.0% with SAP to 1.6% with AID (-1.5% [-2.4% to -0.5%], P = 0.002). The adaptation system decreased initial basal rates by a median of 4% (-8%, 16%) and increased initial carbohydrate ratios by a median of 45% (32%, 59%) after 13 weeks. Conclusions: Automated adaptation of insulin delivery settings with AID use did not significantly improve time-in-range in this very well-controlled population. Additional study and further refinement of the adaptation system are needed, especially in populations with differing degrees of baseline glycemic control, who may show larger benefits from adaptation.


Assuntos
Diabetes Mellitus Tipo 1 , Insulina , Adulto , Glicemia , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Recém-Nascido , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Insulina Regular Humana/uso terapêutico , Pessoa de Meia-Idade , Pacientes Ambulatoriais , Adulto Jovem
18.
Diabetes Technol Ther ; 23(4): 245-252, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33155824

RESUMO

Background: Data are limited on the need for and benefits of pump setting optimization with automated insulin delivery. We examined clinical management of a closed-loop control (CLC) system and its relationship to glycemic outcomes. Materials and Methods: We analyzed personal parameter adjustments in 168 participants in a 6-month multicenter trial of CLC with Control-IQ versus sensor-augmented pump (SAP) therapy. Preset parameters (BR = basal rates, CF = correction factors, CR = carbohydrate ratios) were optimized at randomization, 2 and 13 weeks, for safety issues, participant concerns, or initiation by participants' usual diabetes care team. Time in range (TIR 70-180 mg/dL) was compared in the week before and after parameter changes. Results: In 607 encounters for parameter changes, there were fewer adjustments for CLC than SAP (3.4 vs. 4.1/participant). Adjustments involved BR (CLC 69%, SAP 80%), CR (CLC 68%, SAP 50%), CF (CLC 44%, SAP 41%), and overnight parameters (CLC 62%, SAP 75%). TIR before and after adjustments was 71.2% and 71.3% for CLC and 61.0% and 62.9% for SAP. The highest baseline HbA1c CLC subgroup had the largest TIR improvement (51.2% vs. 57.7%). When a CR was made more aggressive in the CLC group, postprandial time >180 mg/dL was 43.1% before the change and 36.0% after the change. The median postprandial time <70 mg/dL before making CR less aggressive was 1.8%, and after the change was 0.7%. Conclusions: No difference in TIR was detected with parameter changes overall, but they may have an effect in higher HbA1c subgroups or following user-directed boluses, suggesting that changes may matter more in suboptimal control or during discrete periods of the day. Clinical Trials Registration number: NCT03563313.


Assuntos
Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico
19.
Diabetes Technol Ther ; 23(10): 673-683, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34115959

RESUMO

Background: Closed-loop control (CLC) has been shown to improve glucose time in range and other glucose metrics; however, randomized trials >3 months comparing CLC with sensor-augmented pump (SAP) therapy are limited. We recently reported glucose control outcomes from the 6-month international Diabetes Closed-Loop (iDCL) trial; we now report patient-reported outcomes (PROs) in this iDCL trial. Methods: Participants were randomized 2:1 to CLC (N = 112) versus SAP (N = 56) and completed questionnaires, including Hypoglycemia Fear Survey, Diabetes Distress Scale (DDS), Hypoglycemia Awareness, Hypoglycemia Confidence, Hyperglycemia Avoidance, and Positive Expectancies of CLC (INSPIRE) at baseline, 3, and 6 months. CLC participants also completed Diabetes Technology Expectations and Acceptance and System Usability Scale (SUS). Results: The Hypoglycemia Fear Survey Behavior subscale improved significantly after 6 months of CLC compared with SAP. DDS did not differ except for powerless subscale scores, which worsened at 3 months in SAP. Whereas Hypoglycemia Awareness and Hyperglycemia Avoidance did not differ between groups, CLC participants showed a tendency toward improved confidence in managing hypoglycemia. The INSPIRE questionnaire showed favorable scores in the CLC group for teens and parents, with a similar trend for adults. At baseline and 6 months, CLC participants had high positive expectations for the device with Diabetes Technology Acceptance and SUS showing high benefit and low burden scores. Conclusion: CLC improved some PROs compared with SAP. Participants reported high benefit and low burden with CLC. Clinical Trial Identifier: NCT03563313.


Assuntos
Diabetes Mellitus Tipo 1 , Sistemas de Infusão de Insulina , Adolescente , Adulto , Glicemia , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Medidas de Resultados Relatados pelo Paciente
20.
Diabetes Technol Ther ; 23(5): 342-349, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33216667

RESUMO

Objective: To assess the efficacy and safety of closed-loop control (CLC) insulin delivery system in adolescents and young adults with type 1 diabetes. Research Design and Methods: Prespecified subanalysis of outcomes in adolescents and young adults aged 14-24 years old with type 1 diabetes in a previously published 6-month multicenter randomized trial. Participants were randomly assigned 2:1 to CLC (Tandem Control-IQ) or sensor augmented pump (SAP, various pumps+Dexcom G6 CGM) and followed for 6 months. Results: Mean age of the 63 participants was 17 years, median type 1 diabetes duration was 7 years, and mean baseline HbA1c was 8.1%. All 63 completed the trial. Time in range (TIR) increased by 13% with CLC versus decreasing by 1% with SAP (adjusted treatment group difference = +13% [+3.1 h/day]; 95% confidence interval [CI] 9-16, P < 0.001), which largely reflected a reduction in time >180 mg/dL (adjusted difference -12% [-2.9 h/day], P < 0.001). Time <70 mg/dL decreased by 1.6% with CLC versus 0.3% with SAP (adjusted difference -0.7% [-10 min/day], 95% CI -1.0% to -0.2%, P = 0.002). CLC use averaged 89% of the time for 6 months. The mean adjusted difference in HbA1c after 6 months was 0.30% in CLC versus SAP (95% CI -0.67 to +0.08, P = 0.13). There was one diabetic ketoacidosis episode in the CLC group. Conclusions: CLC use for 6 months was substantial and associated with improved TIR and reduced hypoglycemia in adolescents and young adults with type 1 diabetes. Thus, CLC has the potential to improve glycemic outcomes in this challenging age group. The clinical trial was registered with ClinicalTrials.gov (NCT03563313).


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Adolescente , Adulto , Diabetes Mellitus Tipo 1/tratamento farmacológico , Controle Glicêmico , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa