RESUMO
Microbial infection and insufficient tissue formation are considered to be the two main causes of dental implant failure. Novel studies have focused on designing dual-functional strategies to promote antibacterial properties and improve tissue cell response simultaneously. In this study, we investigated the antibacterial properties and cytocompatibility of silver nitrate (AgNO3) and strontium acetate (SrAc) in a mono-culture setup for dental application. Additionally, we defined the therapeutic window between the minimum inhibitory concentration against pathogenic bacteria and maximum cytocompatible dose in the case of combined applications in a co-culture setup. Antibacterial properties were screened using Aggregatibacter actinomycetemcomitans and cell response experiments were performed with osteoblastic cells (MC3T3) and fibroblastic cells (NIH3T3). The osteoinductive behavior was investigated separately on MC3T3 cells using alizarin red staining. A therapeutic window for AgNO3 as well as SrAc applications could be defined in the case of MC3T3 cells while the cytocompatibility of NIH3T3 cells was compromised for all concentrations with an antibacterial effect. However, the combined application of AgNO3/SrAc caused an enhanced antibacterial effect and opened a therapeutic window for both cell lines. Enhanced mineralization rates could be observed in cultures containing SrAc. In conclusion, we were able to demonstrate that adding SrAc to AgNO3 not only intensifies antibacterial properties but also exhibits bone inductive characteristics, thereby offering a promising strategy to combat peri-implantitis and at the same time improve osseointegration in implant therapy.
Assuntos
Nitrato de Prata , Estrôncio , Acetatos , Animais , Antibacterianos/farmacologia , Camundongos , Células NIH 3T3 , Estrôncio/farmacologia , Titânio/farmacologiaRESUMO
Bacterial infections are a major challenge to human health. Although various potent antibiotics have emerged in the last decades, current challenges arise from an increasing number of multi-drug-resistant species. Infections associated with implants represent a particular challenge since they are usually diagnosed at an advanced state, and are difficult to treat with antibiotics due to the formation of protecting biofilms. In this study, we designed and explored a synthetic biology-inspired, cell-based bio-sensor/actor for the detection and counteraction of bacterial infections. The system is generic as it senses diverse types of infections and acts by enhancement of the endogenous immune system. The strategy is based on genetically engineered sensor/actor cells that can sense type I interferons (IFNs), which are released by immune cells at the early stages of infections. IFN signalling activates a synthetic circuit to induce reporter genes with a sensitivity of only 5 pg/ml of IFN and leads to a therapeutic protein output of 100ng/ml, resulting in theranostic cells that visualize and fight infections. Robustness and resilience were achieved by the implementation of a positive feedback loop. We show that diverse gram-positive and gram-negative implant-associated pathogenic bacteria activate the cascade in co-culture systems in a dose-dependent manner. Finally, we show that this system can be used to secrete chemoattractants facilitating the infiltration of immune cells in response to bacterial triggers. Together, the system is not only universal to bacterial infections but at the same time hypersensitive allowing the sensing of infections at initial stages.
RESUMO
Type I interferon-beta (IFN-ß) is a crucial component of innate and adaptive immune systems inside the host. The formation of bacterial biofilms on medical implants can lead to inflammatory diseases and implant failure. Biofilms elicit IFN-ß production inside the host that, in turn, restrict bacterial growth. Biofilms pose strong antibiotic resistance, whereas surface modification of medical implants with antibacterial agents may demonstrate strong antimicrobial effects. Most of the previous investigations were focused on determining the antibacterial activities of implant surfaces modified with antibacterial agents. The present study, for the first time, measured antibacterial activities and IFN-ß expression of titanium surfaces along with silver or tetracycline inside co-culture and mouse models. A periodontal pathogen: Aggregatibacter actinomycetemcomitans reported to induce strong inflammation, was used for infection. Silver and tetracycline were added to the titanium surface using the heat evaporation method. Macrophages showed reduced compatibility on titanium surfaces with silver, and IFN-ß expression inside cultured cells significantly decreased. Macrophages showed compatibility on implant surfaces with tetracycline, but IFN-ß production significantly decreased inside seeded cells. The decrease in IFN-ß production inside macrophages cultured on implant surfaces with silver and tetracycline was not related to the downregulation of Ifn-ß gene. Bacterial infection significantly upregulated mRNA expression levels of Isg15, Mx1, Mx2, Irf-3, Irf-7, Tlr-2, Tnf-α, Cxcl-1, and Il-6 genes. Notably, mRNA expression levels of Mx1, Irf7, Tlr2, Tnf-α, Cxcl1, and Il-6 genes inside macrophages significantly downregulated on implant surfaces with silver or tetracycline. Titanium with tetracycline showed higher antibacterial activities than silver. The in vivo evaluation of IFN-ß expression around implants was measured inside transgenic mice constitutive for IFN-ß expression. Of note, the non-invasive in vivo imaging revealed a significant decrease in IFN-ß expression around subcutaneous implants with silver compared to titanium and titanium with tetracycline in sterile or infected situations. The histology of peri-implant tissue interfaces around infected implants with silver showed a thick interface with a significantly higher accumulation of inflammatory cells. Titanium implants with silver and tetracycline remained antibacterial in mice. Findings from this study unequivocally indicate that implant surfaces with silver decrease IFN-ß expression, a crucial component of host immunity.
RESUMO
Cytokine profiles are often perturbed after infections of medical implants. With a non-invasive in vivo imaging system, we report in a mouse model that interferon expression after infection of subcutaneous implants with Streptococcus oralis, Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, and Treponema denticola (alone or as a combination) was species-specific, persisted longer in the presence of implants, and notably decreased upon dual species infections. This type I interferon expression disappeared within two weeks; however, histology of implant-tissue interface indicated high recruitment of immune cells even after three weeks. This was suggestive that biomaterial-associated infections could have prolonged effects, including the systemic stimulation of inflammatory cytokines. The present study investigated the systemic impact of this chronic peri-implant inflammation on the systemic expression of inflammatory cytokines (23) using a multiplex assay. Initially, the cytokine measurement in murine fibroblasts exposed to periodontal pathogens remained limited to the expression of five cytokines, namely, IL-6, G-CSF, CXCL-1/KC, MCP-1 (MCAF), and IL-12 (p40). The systemic determination of cytokines in mice increased to 19 cytokines (IL-1α, IL-2, IL-3, IL-5, IL-6, IL-9, IL-12 (p40), IL-12 (p70), IL-13, IL-17A, CCL-11/Eotaxin, G-CSF, IFN-γ, CXCL1/KC, MCP-1 (MCAF), MIP-1α/CCL3, MIP-1ß/CCL4, CCL5/RANTES, and TNF-α). Systemic induction of cytokines was species-specific in the mouse model. The cytokine induction from infected implants differed significantly from sole tissue infections and sterile implants. Notably, systemic cytokine induction decreased after infections with dual species compared to single species infections. These findings describe the systemic effect of chronic peri-implant inflammation on the systemic induction of inflammatory cytokines, and this effect was strongly correlated to the type and composition of initial infection. Systemic modulations in cytokine expression upon dual species infections exhibit an exciting pattern that might explain the complications associated with biomaterial-related infection in patients. Moreover, these findings validate the requirement of multispecies infections for pre-clinical studies involving animal models.
RESUMO
Infections of medical implants caused by bacterial biofilms are a major clinical problem. Bacterial colonization is predicted to be prevented by alkaline magnesium surfaces. However, in experimental animal studies, magnesium implants prolonged infections. The reason for this peculiarity likely lies within the âstill largely hypotheticalâ mechanism by which infection arises. Investigating subcutaneous magnesium implants infected with bioluminescent Pseudomonas aeruginosa via in vivo imaging, we found that the rate of implant infections was critically dependent on a surprisingly high quantity of injected bacteria. At high inocula, bacteria were antibiotic-refractory immediately after infection. High cell densities are known to limit nutrient availability, restricting proliferation and trigger quorum sensing which could both contribute to the rapid initial resistance. We propose that gas bubbles such as those formed during magnesium corrosion, can then act as interfaces that support biofilm formation and permit long-term survival. This model could provide an explanation for the apparent ineffectiveness of innovative contact-dependent bactericidal implant surfaces in patients. In addition, the model points toward air bubbles in tissue, either by inclusion during surgery or by spontaneous gas bubble formation later on, could constitute a key risk factor for clinical implant infections.
Assuntos
Antibacterianos/farmacologia , Biofilmes/efeitos dos fármacos , Modelos Animais de Doenças , Magnésio/farmacologia , Pseudomonas aeruginosa/efeitos dos fármacos , Animais , Feminino , Gases/química , Camundongos , Camundongos Endogâmicos BALB C , Testes de Sensibilidade Microbiana , Tamanho da Partícula , Propriedades de SuperfícieRESUMO
The performance of biomaterials is often compromised by bacterial infections and subsequent inflammation. So far, the conventional analysis of inflammatory processes in vivo involves time-consuming histology and biochemical assays. The present study employed a mouse model where interferon beta (IFN-ß) is monitored as a marker for non-invasive rapid detection of inflammation in implant-related infections. The mouse model comprises subcutaneous implantation of morphologically modified titanium, followed by experimental infections with four taxonomically diverse oral bacteria: Streptococcus oralis, Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis and Treponema denticola (as mono culture or selected mixed-culture). IFN-ß expression increased upon infections depending on the type of pathogen and was prolonged by the presence of the implant. IFN-ß expression kinetics reduced with two mixed species infections when compared with the single species. Histological and confocal microscopy confirmed pathogen-specific infiltration of inflammatory cells at the implant-tissue interface. This was observed mainly in the vicinity of infected implants and was, in contrast to interferon expression, higher in infections with dual species. In summary, this non-invasive mouse model can be used to quantify longitudinally host inflammation in real time and suggests that the polymicrobial character of infection, highly relevant to clinical situations, has complex effects on host immunity.
RESUMO
Development of a guided occlusive biodegradable membrane with controlled morphology in order to restrict the ingrowth of epithelial cells is still a challenge in dental tissue engineering. A bilayer membrane with a non-porous upper layer (polyurethane) and porous lower layer (polycaprolactone and bioactive glass composite) with thermoelastic properties to sustain surgery treatment was developed by lyophilization. Morphology, porosity, and layers attachment were controlled by using the multi-solvent system. In vitro and in vivo biocompatibility, cell attachment, and cell proliferation were analyzed by immunohistochemistry and histology. The cell proliferation rate and cell attachment results showed good biocompatibility of both surfaces, though cell metabolic activity was better on the polycaprolactone-bioactive glass surface. Furthermore, the cells were viable, adhered, and proliferated well on the lower porous bioactive surface, while non-porous polyurethane surface demonstrated low cell attachment, which was deliberately designed and a pre-requisite for guided tissue regeneration/guided bone regeneration membranes. In addition, in vivo studies performed in a rat model for six weeks revealed good compatibility of membranes. Histological analysis (staining with hematoxylin and eosin) indicated no signs of inflammation or accumulation of host immune cells. These results suggested that the fabricated biocompatible bilayer membrane has the potential for use in periodontal tissue regeneration.
Assuntos
Materiais Biocompatíveis/química , Regeneração Tecidual Guiada Periodontal , Membranas Artificiais , Poliésteres/química , Poliuretanos/química , Animais , Regeneração Óssea , Linhagem Celular Tumoral , Masculino , Porosidade , Ratos , Alicerces Teciduais/químicaRESUMO
A novel tri-layered, functionally-graded chitosan membrane (FGM) with bioactive glass gradient (50%, 25%, and 0% wt.) was developed by lyophilization. A step-wise grading of chitosan, bioactive glass (BG), and Pluronic F127 was introduced into the membrane in which each layer has separate surface functions that play a role of guided tissue regeneration (GTR) membranes. The lower layer was designed to replicate alveolar bone and contains 50%wt. BG, the middle layer contains 25%wt. BG, while the upper layer was non-porous without BG and it did not support cell growth. Scanning Electron Microscopy (SEM) revealed that the lower FGM surface possessed a porous structure with embedded BG particles, while the upper surface was non-porous with interconnected architecture. The contact angle measurement confirmed that the surface with BG was hydrophilic (≈00), while the opposite surface was hydrophobic (910⯱â¯3.840). Both osteoblast and fibroblast cells have maximum adhesion at contact angle <80°. Alamar blue assay revealed the biocompatibility of the MC3T3-E1 mouse pre-osteoblasts cells with these membranes in vitro. The cells attachment and proliferation was seen for lower surface, while no cells adhesion was observed for the upper layer. Additionally, the interaction of the tissue with these tri-layered membranes was also investigated in vivo. Hematoxylin and eosin staining revealed the biocompatible nature of these membranes. Altogether, these results indicated that due to the biocompatible nature of these membranes, they will be a good carrier of in vivo implantation.
Assuntos
Implantes Dentários , Regeneração Tecidual Guiada/instrumentação , Membranas Artificiais , Osteoblastos/citologia , Animais , Materiais Biocompatíveis/química , Adesão Celular , Quitosana/química , Vidro/química , Teste de Materiais , Camundongos , Microscopia Eletrônica de Varredura , Nanopartículas/química , Poloxâmero/química , Ratos Wistar , Espectroscopia de Infravermelho com Transformada de Fourier , Difração de Raios XRESUMO
Biomaterial-associated Pseudomonas aeruginosa biofilm infections constitute a cascade of host immune reactions ultimately leading to implant failure. Due to the lack of relevant in vivo biofilm models, the majority of the studies report host immune responses to free-living or planktonic bacteria, while bacteria in clinical situations live more frequently as biofilm communities than as single cells. The present study investigated host immune responses to biomaterial-associated P. aeruginosa biofilms in a clinically relevant mouse model. Previously, we reported metallic magnesium, a prospective biodegradable implant, to be permissive for bacterial biofilm in vivo even though it exhibits antibacterial properties in vitro. Therefore, magnesium was employed as biomaterial to investigate in vivo biofilm formation and associated host immune responses by using two P. aeruginosa strains and two mouse strains. P. aeruginosa formed biofilm on subcutaneously implanted magnesium disks. Non-invasive in vivo imaging indicated transient inflammatory responses at control sites, whereas robust prolonged interferon-ß (IFN-ß) expression was observed from biofilm in a transgenic animal reporter. Furthermore, immunohistology and electron microscopic results showed that bacterial biofilms were located in 2D immediately on the implant surface and at a short distance in the adjacent tissue. These biofilms were surrounded by inflammatory cells (mainly polymorphonuclear cells) compared to the controls. Interestingly, even though the number of live bacteria in various organs remained below detectable levels, splenomegaly indicated systemic inflammatory processes. Overall, these findings confirmed the resistance of biofilm infections in vivo to potentially antibacterial properties of magnesium degradation products. In vivo imaging and histology indicated the induction of both local and systemic host inflammatory responses to P. aeruginosa biofilms. Even though the innate host immune defenses could not eliminate the local infection for up to two weeks, there was no apparent systemic bacteremia and all the animals investigated survived the infection.
Assuntos
Biofilmes , Magnésio/química , Próteses e Implantes , Infecções Relacionadas à Prótese/imunologia , Animais , Animais Geneticamente Modificados , Antibacterianos/farmacologia , Materiais Biocompatíveis/química , Modelos Animais de Doenças , Feminino , Sistema Imunitário , Imuno-Histoquímica , Inflamação , Interferon beta/metabolismo , Teste de Materiais , Camundongos , Camundongos Endogâmicos BALB C , Microscopia Eletrônica , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão , Infecções por Pseudomonas , Pseudomonas aeruginosa/metabolismoRESUMO
Magnesium alloys are presently under investigation as promising biodegradable implant materials with osteoconductive properties. To study the molecular mechanisms involved, the potential contribution of soluble magnesium corrosion products to the stimulation of osteoblastic cell differentiation was examined. However, no evidence for the stimulation of osteoblast differentiation could be obtained when cultured mesenchymal precursor cells were differentiated in the presence of metallic magnesium or in cell culture medium containing elevated magnesium ion levels. Similarly, in soft tissue no bone induction by metallic magnesium or by the corrosion product magnesium hydroxide could be observed in a mouse model. Motivated by the comparatively rapid accumulation solid corrosion products physicochemical processes were examined as an alternative mechanism to explain the stimulation of bone growth by magnesium-based implants. During exposure to physiological solutions a structured corrosion coat formed on magnesium whereby the elements calcium and phosphate were enriched in the outermost layer which could play a role in the established biocompatible behavior of magnesium implants. When magnesium pins were inserted into avital bones, corrosion lead to increases in the pull out force, suggesting that the expanding corrosion layer was interlocking with the surrounding bone. Since mechanical stress is a well-established inducer of bone growth, volume increases caused by the rapid accumulation of corrosion products and the resulting force development could be a key mechanism and provide an explanation for the observed stimulatory effects of magnesium-based implants in hard tissue. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 697-709, 2017.
Assuntos
Implantes Experimentais , Magnésio , Células-Tronco Mesenquimais/metabolismo , Coluna Vertebral/metabolismo , Animais , Linhagem Celular , Corrosão , Feminino , Magnésio/química , Magnésio/farmacocinética , Magnésio/farmacologia , Camundongos , Camundongos Endogâmicos BALB CRESUMO
Magnesium alloys have promising mechanical and biological properties for the development of degradable implants. However, rapid implant corrosion and gas accumulations in tissue impede clinical applications. With time, the implant degradation rate is reduced by a highly biocompatible, phosphate-containing corrosion layer. To circumvent initial side effects after implantation it was attempted to develop a simple in vitro procedure to generate a similarly protective phosphate corrosion layer. To this end magnesium samples were pre-incubated in phosphate solutions. The resulting coating was well adherent during routine handling procedures. It completely suppressed the initial burst of corrosion and it reduced the average in vitro magnesium degradation rate over 56 days almost two-fold. In a small animal model phosphate coatings on magnesium implants were highly biocompatible and abrogated the appearance of gas cavities in the tissue. After implantation, the phosphate coating was replaced by a layer with an elemental composition that was highly similar to the corrosion layer that had formed on plain magnesium implants. The data demonstrate that a simple pre-treatment could improve clinically relevant properties of magnesium-based implants. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1622-1635, 2017.
Assuntos
Materiais Revestidos Biocompatíveis , Implantes Experimentais , Magnésio , Teste de Materiais , Fosfatos , Animais , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Corrosão , Feminino , Magnésio/química , Magnésio/farmacologia , Camundongos , Camundongos Endogâmicos BALB C , Fosfatos/química , Fosfatos/farmacologiaRESUMO
Magnesium alloys have promising mechanical and biological properties as biodegradable medical implant materials for temporary applications during bone healing or as vascular stents. Whereas conventional implants are prone to colonization by treatment resistant microbial biofilms in which bacteria are embedded in a protective matrix, magnesium alloys have been reported to act antibacterial in vitro. To permit a basic assessment of antibacterial properties of implant materials in vivo an economic but robust animal model was established. Subcutaneous magnesium implants were inoculated with bacteria in a mouse model. Contrary to the expectations, bacterial activity was enhanced and prolonged in the presence of magnesium implants. Systemic antibiotic treatments were remarkably ineffective, which is a typical property of bacterial biofilms. Biofilm formation was further supported by electron microscopic analyses that revealed highly dense bacterial populations and evidence for the presence of extracellular matrix material. Bacterial agglomerates could be detected not only on the implant surface but also at a limited distance in the peri-implant tissue. Therefore, precautions may be necessary to minimize risks of metallic magnesium-containing implants in prospective clinical applications. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 1489-1499, 2016.
Assuntos
Implantes Absorvíveis , Infecções Bacterianas/microbiologia , Biofilmes/efeitos dos fármacos , Magnésio/farmacologia , Infecções Relacionadas à Prótese/microbiologia , Animais , Contagem de Colônia Microbiana , Resistência Microbiana a Medicamentos/efeitos dos fármacos , Feminino , Camundongos Endogâmicos BALB C , Pseudomonas aeruginosa/efeitos dos fármacos , Pseudomonas aeruginosa/crescimento & desenvolvimento , Staphylococcus aureus/efeitos dos fármacosRESUMO
To evaluate the inflammatory potential of implants a bioluminescent imaging assay was developed using luciferase-expressing bone marrow cells that were injected into the blood circulation of wild-type mice. After subcutaneous implantation of titanium discs as an example for a clinically established biocompatible material, the luminosity was modest. Similarly, low luminosity signals were generated by pure magnesium implants that were used to represent metallic alloys that are presently under investigation as novel degradable implant materials. Increased luminosity was observed in response to degradable polymeric PLGA implants. Surgical wounds induced a basic luminescent response even in the absence of an implant. However, the material-independent response to injury could be minimized using injectable microparticle suspensions. In parallel with the resorption of biodegradable microparticles, the signal induced by PLGA declined faster when compared to non-degradable polystyrene suspensions. By using an interferon type I inducible Mx2 promoter construct to drive luciferase gene expression, the highest luminosity was observed in response to bacteria, indicating that the system could also be employed to monitor implant infections. Overall, labeled bone marrow cells yielded specific, well-defined localized signals that correlated with the inflammatory responses to implants. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 2149-2158, 2016.
Assuntos
Implantes Absorvíveis , Células da Medula Óssea , Transplante de Medula Óssea , Rastreamento de Células/métodos , Aloenxertos , Animais , Células da Medula Óssea/metabolismo , Células da Medula Óssea/patologia , Inflamação/metabolismo , Inflamação/patologia , Camundongos , Modelos Biológicos , Poliestirenos/efeitos adversos , Poliestirenos/farmacologiaRESUMO
The total hip arthroplasty is one of the most common artificial joint replacement procedures. Several different surface coatings have been shown to improve implant fixation by facilitating bone ingrowth and consequently enhancing the longevity of uncemented orthopaedic hip prostheses. In the present study, two different layered double hydroxides (LDHs), Mg-Fe- and Mg-Al-LDH, were investigated as potential magnesium (Mg)-containing coating materials for orthopaedic applications in comparison to Mg hydroxide (Mg(OH)2). In vitro direct cell compatibility tests were carried out using the murine fibroblast cell line NIH 3T3 and the mouse osteosarcoma cell line MG 63. The host response of bone tissue was evaluated in in vivo experiments with nine rabbits. Two cylindrical pellets (3 × 3 mm) were implanted into each femoral condyle of the left hind leg. The samples were analyzed histologically and with µ-computed tomography (µ-CT) 6 weeks after surgery. An in vitro cytotoxicity test determined that more cells grew on the LDH pellets than on the Mg(OH)2-pellets. The pH value and the Mg(2+) content of the cell culture media were increased after incubation of the cells on the degradable samples. The in vivo tests demonstrated the formation of fibrous capsules around Mg(OH)2 and Mg-Fe-LDH. In contrast, the host response of the Mg-Al-LDH samples indicated that this Mg-containing biomaterial is a potential candidate for implant coating.
Assuntos
Substitutos Ósseos , Materiais Revestidos Biocompatíveis , Hidróxido de Magnésio , Magnésio , Teste de Materiais , Osteogênese/efeitos dos fármacos , Hidróxido de Alumínio/química , Hidróxido de Alumínio/farmacologia , Animais , Substitutos Ósseos/química , Substitutos Ósseos/farmacologia , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Feminino , Magnésio/química , Magnésio/farmacologia , Hidróxido de Magnésio/química , Hidróxido de Magnésio/farmacologia , Camundongos , Células NIH 3T3 , CoelhosRESUMO
Magnesium alloys are presently investigated as potential medical implant materials for temporary applications. Magnesium has been reported to have antibacterial activities and could therefore be used to prevent antibiotic treatment-resistant bacterial implant infections. For characterizing the effects of magnesium on infectious bacteria, bioluminescent S. aureus or P. aeruginosa were employed. The proliferation of both types of bacteria was suppressed in the presence of metallic magnesium and also in aqueous magnesium corrosion extracts. Of the two soluble corrosion products, magnesium ions were well tolerated while antibacterial activities correlated with increased pH levels of the supernatants. The alkaline pH alone was sufficient for the antibacterial effects which were completely abolished when the pH of the corrosion supernatants was neutralized. These results demonstrate that pH increases are necessary and sufficient for the antibacterial activity of metallic magnesium. In an animal model magnesium implants showed an enhanced but variable resistance to bacterial colonization.
Assuntos
Álcalis/química , Antibacterianos/farmacologia , Magnésio/farmacologia , Animais , Antibacterianos/uso terapêutico , Corrosão , Modelos Animais de Doenças , Feminino , Concentração de Íons de Hidrogênio , Imageamento Tridimensional , Íons , Camundongos Endogâmicos BALB C , Testes de Sensibilidade Microbiana , Infecções Relacionadas à Prótese/tratamento farmacológico , Pseudomonas aeruginosa/efeitos dos fármacos , Solubilidade , Staphylococcus aureus/efeitos dos fármacosRESUMO
As an alternative to degradable organic coatings the possibility of using layered double hydroxides (LDHs) to generate implant coatings for controlled drug delivery was evaluated in vivo and in vitro. Coatings prepared from LDH suspensions dissolved slowly and appeared compatible with cultured cells. LDH coatings loaded with an antibiotic resulted in antibacterial effects in vitro. The LDH coating prolonged the drug release period and improved the proliferation of adherent cells in comparison to pure drug coatings. However, during incubation in physiological solutions the LDH coatings became brittle and pieces occasionally detached from the surface. For stress protection porous titanium implants were investigated as a substrate for the coatings. The pores prevented premature detachment of the coatings. To evaluate the coated porous implants in vivo a mouse model was established. To monitor bacterial infection of implants noninvasive in vivo imaging was used to monitor luminescently labeled Pseudomonas aeruginosa. In this model porous implants with antibiotic-loaded LDH coatings could antagonize bacterial infections for over 1 week. The findings provide evidence that delayed drug delivery from LDH coatings could be feasible in combination with structured implant surfaces.
Assuntos
Antibacterianos/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Hidróxidos/farmacologia , Titânio/farmacologia , Animais , Ciprofloxacina/farmacologia , Preparações de Ação Retardada/farmacologia , Feminino , Camundongos , Camundongos Endogâmicos BALB C , Modelos Animais , Células NIH 3T3 , Porosidade , VolatilizaçãoRESUMO
Magnesium alloys have been proposed as prospective degradable implant materials. To elucidate the complex interactions between the corroding implants and the tissue, magnesium implants were analyzed in a mouse model and the response was compared to that induced by Ti and by the resorbable polymer polyglactin, respectively. One month after implantation, distinct traces of corrosion were apparent but the magnesium implants were still intact, whereas resorbable polymeric wound suture implants were already fragmented. Analysis of magnesium implants 2weeks after implantation by energy-dispersive X-ray spectroscopy indicated that magnesium, oxygen, calcium and phosphate were present at the implant surface. One month after implantation, the element composition of the outermost layer of the implant was indicative of tissue without detectable levels of magnesium, indicating a protective barrier function of this organic layer. In agreement with this notion, gene expression patterns in the surrounding tissue were highly similar for all implant materials investigated. However, high-resolution imaging using energy-filtered transmission electron microscopy revealed magnesium-containing microparticles in the tissue in the proximity of the implant. The release of such corrosion particles may contribute to the accumulation of calcium phosphate in the nearby tissue and to bone conductive activities of magnesium implants.