Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Nanobiotechnology ; 15(1): 3, 2017 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-28052769

RESUMO

BACKGROUND: Bloodstream infections (BSI) remain a major challenge with high mortality rate, with an incidence that is increasing worldwide. Early treatment with appropriate therapy can reduce BSI-related morbidity and mortality. However, despite recent progress in molecular based assays, complex sample preparation steps have become critical roadblock for a greater expansion of molecular assays. Here, we report a size based, label-free, bacteria separation from whole blood using elasto-inertial microfluidics. RESULTS: In elasto-inertial microfluidics, the viscoelastic flow enables size based migration of blood cells into a non-Newtonian solution, while smaller bacteria remain in the streamline of the blood sample entrance and can be separated. We first optimized the flow conditions using particles, and show continuous separation of 5 µm particles from 2 µm at a yield of 95% for 5 µm particle and 93% for 2 µm particles at respective outlets. Next, bacteria were continuously separated at an efficiency of 76% from undiluted whole blood sample. CONCLUSION: We demonstrate separation of bacteria from undiluted while blood using elasto-inertial microfluidics. The label-free, passive bacteria preparation method has a great potential for downstream phenotypic and molecular analysis of bacteria.


Assuntos
Bactérias/isolamento & purificação , Microfluídica/métodos , Sepse/diagnóstico , Bactérias/química , Células Sanguíneas/citologia , Elasticidade , Escherichia coli/química , Escherichia coli/isolamento & purificação , Corantes Fluorescentes/química , Humanos , Microfluídica/instrumentação , Tamanho da Partícula , Sepse/microbiologia
2.
Biomed Microdevices ; 18(4): 71, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27444649

RESUMO

We demonstrate an acoustic platform for micro-vortexing in disposable polymer microfluidic chips with small-volume (20 µl) reaction chambers. The described method is demonstrated for a variety of standard vortexing functions, including mixing of fluids, re-suspension of a pellet of magnetic beads collected by a magnet placed on the chip, and lysis of cells for DNA extraction. The device is based on a modified Langevin-type ultrasonic transducer with an exponential horn for efficient coupling into the microfluidic chip, which is actuated by a low-cost fixed-frequency electronic driver board. The transducer is optimized by numerical modelling, and different demonstrated vortexing functions are realized by actuating the transducer for varying times; from fractions of a second for fluid mixing, to half a minute for cell lysis and DNA extraction. The platform can be operated during 1 min below physiological temperatures with the help of a PC fan, a Peltier element and an aluminum heat sink acting as the chip holder. As a proof of principle for sample preparation applications, we demonstrate on-chip cell lysis and DNA extraction within 25 s. The method is of interest for automating and chip-integrating sample preparation procedures in various biological assays.


Assuntos
Acústica , Técnicas Analíticas Microfluídicas , Microfluídica/instrumentação , Células A549 , Humanos , Campos Magnéticos , Polímeros/química
3.
Biotechnol Lett ; 37(4): 825-30, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25413883

RESUMO

Blood-stream infections (BSI) remain a major health challenge, with an increasing incidence worldwide and a high mortality rate. Early treatment with appropriate antibiotics can reduce BSI-related morbidity and mortality, but success requires rapid identification of the infecting organisms. The rapid, culture-independent diagnosis of BSI could be significantly facilitated by straightforward isolation of highly purified bacteria from whole blood. We present a microfluidic-based, sample-preparation system that rapidly and selectively lyses all blood cells while it extracts intact bacteria for downstream analysis. Whole blood is exposed to a mild detergent, which lyses most blood cells, and then to osmotic shock using deionized water, which eliminates the remaining white blood cells. The recovered bacteria are 100% viable, which opens up possibilities for performing drug susceptibility tests and for nucleic-acid-based molecular identification.


Assuntos
Bactérias/isolamento & purificação , Técnicas Bacteriológicas/métodos , Dispositivos Lab-On-A-Chip , Microfluídica/métodos , Sepse/diagnóstico , Viabilidade Microbiana , Sepse/microbiologia , Manejo de Espécimes/métodos
4.
Biosensors (Basel) ; 12(7)2022 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-35884324

RESUMO

Bioprinting is an acclaimed technique that allows the scaling of 3D architectures in an organized pattern but suffers from a scarcity of appropriate bioinks. Decellularized extracellular matrix (dECM) from xenogeneic species has garnered support as a biomaterial to promote tissue-specific regeneration and repair. The prospect of developing dECM-based 3D artificial tissue is impeded by its inherent low mechanical properties. In recent years, 3D bioprinting of dECM-based bioinks modified with additional scaffolds has advanced the development of load-bearing constructs. However, previous attempts using dECM were limited to low-temperature bioprinting, which is not favorable for a longer print duration with cells. Here, we report the development of a multi-material decellularized liver matrix (dLM) bioink reinforced with gelatin and polyethylene glycol to improve rheology, extrudability, and mechanical stability. This shear-thinning bioink facilitated extrusion-based bioprinting at 37 °C with HepG2 cells into a 3D grid structure with a further enhancement for long-term applications by enzymatic crosslinking with mushroom tyrosinase. The heavily crosslinked structure showed a 16-fold increase in viscosity (2.73 Pa s-1) and a 32-fold increase in storage modulus from the non-crosslinked dLM while retaining high cell viability (85-93%) and liver-specific functions. Our results show that the cytocompatible crosslinking of dLM bioink at physiological temperatures has promising applications for extended 3D-printing procedures.


Assuntos
Bioimpressão , Bioimpressão/métodos , Matriz Extracelular/química , Hidrogéis/química , Fígado , Temperatura , Engenharia Tecidual/métodos , Alicerces Teciduais/química
5.
Macromol Biosci ; 22(10): e2200137, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35899862

RESUMO

Three-dimensional multicellular spheroids (MCSs) are complex structure of cellular aggregates and cell-to-matrix interaction that emulates the in-vivo microenvironment. This research field has grown to develop and improve spheroid generation techniques. Here, we present a new platform for spheroid generation using Layer-by-Layer (LbL) technology. Layer-by-Layer (LbL) containing cellulose nanofibrils (CNF) assemble on a standard 96 well plate. Various bi-layer numbers, multiple cell seeding concentration, and two tumor cell lines (HEK 293 T, HCT 116) are utilized to generate and characterize spheroids. The number and proliferation of generated spheroids, the viability, and the response to the anti-cancer drug are examined. The spheroids are formed and proliferated on the LbL-CNF coated wells with no significant difference in connection to the number of LbL-CNF bi-layers; however, the number of formed spheroids correlates positively with the cell seeding concentration (122 ± 17) and (42 ± 8) for HCT 116 and HEK 293T respectively at 700 cells ml-1 . The spheroids proliferate progressively up to (309, 663) µm of HCT 116 and HEK 293T respectively on 5 bi-layers coated wells with maintaining viability. The (HCT 116) spheroids react to the anti-cancer drug. We demonstrate a new (LbL-CNF) coating strategy for spheroids generation, with high performance and efficiency to test anti-cancer drugs.


Assuntos
Antineoplásicos , Celulose , Antineoplásicos/farmacologia , Linhagem Celular Tumoral , Celulose/farmacologia , Ensaios de Seleção de Medicamentos Antitumorais , Células HEK293 , Humanos , Esferoides Celulares
6.
Bioengineering (Basel) ; 9(11)2022 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-36354514

RESUMO

The liver exhibits complex geometrical morphologies of hepatic cells arranged in a hexagonal lobule with an extracellular matrix (ECM) organized in a specific pattern on a multi-scale level. Previous studies have utilized 3D bioprinting and microfluidic perfusion systems with various biomaterials to develop lobule-like constructs. However, they all lack anatomical relevance with weak control over the size and shape of the fabricated structures. Moreover, most biomaterials lack liver-specific ECM components partially or entirely, which might limit their biomimetic mechanical properties and biological functions. Here, we report 3D bioprinting of a sacrificial PVA framework to impart its trilobular hepatic structure to the decellularized liver extracellular matrix (dLM) hydrogel with polyethylene glycol-based crosslinker and tyrosinase to fabricate a robust multi-scale 3D liver construct. The 3D trilobular construct exhibits higher crosslinking, viscosity (182.7 ± 1.6 Pa·s), and storage modulus (2554 ± 82.1 Pa) than non-crosslinked dLM. The co-culture of HepG2 liver cells and NIH 3T3 fibroblast cells exhibited the influence of fibroblasts on liver-specific activity over time (7 days) to show higher viability (90-91.5%), albumin secretion, and increasing activity of four liver-specific genes as compared to the HepG2 monoculture. This technique offers high lumen patency for the perfusion of media to fabricate a densely populated scaled-up liver model, which can also be extended to other tissue types with different biomaterials and multiple cells to support the creation of a large functional complex tissue.

7.
J Nanosci Nanotechnol ; 11(10): 8532-7, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22400220

RESUMO

The sulfo-SMCC (Succinimidyl-4-(N-maleimidomethyl) cyclohexane-1-carboxylate) coupling chemistry was evaluated for immobilization of oligonucleotides onto 130 nm sized magnetic nanobeads aimed for bio-detection in a magnetic readout assay. The chemistry was found to produce a high surface coverage of approximately 93 +/- 10 oligonucleotides per bead whereas stability tests showed that about 50% of the oligonucleotides detached from the bead surfaces after eight weeks of storage in a buffer solution. It was shown that bead aggregation prior to magnetic readout could be suppressed by incubating the samples at 70 degrees C for 30 min. The same temperature was also shown to be the most favorable for hybridization between the oligonucleotide functionalized beads and rolling circle amplified DNA molecules. This should simplify the heating procedure in a biosensor in which hybridization and magnetic readout is performed in the same compartment.


Assuntos
Nanopartículas de Magnetita/química , Maleimidas/química , Oligonucleotídeos/química , Técnicas Biossensoriais/métodos , DNA/química , Hibridização de Ácido Nucleico/métodos , Propriedades de Superfície , Temperatura
8.
Sci Rep ; 11(1): 8467, 2021 04 19.
Artigo em Inglês | MEDLINE | ID: mdl-33875755

RESUMO

Passive particle manipulation using inertial and elasto-inertial microfluidics have received substantial interest in recent years and have found various applications in high throughput particle sorting and separation. For separation applications, elasto-inertial microfluidics has thus far been applied at substantial lower flow rates as compared to inertial microfluidics. In this work, we explore viscoelastic particle focusing and separation in spiral channels at two orders of magnitude higher Reynolds numbers than previously reported. We show that the balance between dominant inertial lift force, dean drag force and elastic force enables stable 3D particle focusing at dynamically high Reynolds numbers. Using a two-turn spiral, we show that particles, initially pinched towards the inner wall using an elasticity enhancer, PEO (polyethylene oxide), as sheath migrate towards the outer wall strictly based on size and can be effectively separated with high precision. As a proof of principle for high resolution particle separation, 15 µm particles were effectively separated from 10 µm particles. A separation efficiency of 98% for the 10 µm and 97% for the 15 µm particles was achieved. Furthermore, we demonstrate sheath-less, high throughput, separation using a novel integrated two-spiral device and achieved a separation efficiency of 89% for the 10 µm and 99% for the 15 µm particles at a sample flow rate of 1 mL/min-a throughput previously only reported for inertial microfluidics. We anticipate the ability to precisely control particles in 3D at extremely high flow rates will open up several applications, including the development of ultra-high throughput microflow cytometers and high-resolution separation of rare cells for point of care diagnostics.

9.
PLoS One ; 16(7): e0254156, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34310609

RESUMO

Detection of tuberculosis at the point-of-care (POC) is limited by the low sensitivity of current commercially available tests. We describe a diagnostic accuracy field evaluation of a prototype urine Tuberculosis Lipoarabinomannan Lateral Flow Assay (TB-LAM LFA) in both HIV-positive and HIV-negative patients using fresh samples with sensitivity and specificity as the measures of accuracy. This prototype combines a proprietary concentration system with a sensitive LFA. In a prospective study of 292 patients with suspected pulmonary tuberculosis in Uganda, the clinical sensitivity and specificity was compared against a microbiological reference standard including sputum Xpert MTB/RIF Ultra and solid and liquid culture. TB-LAM LFA had an overall sensitivity of 60% (95%CI 51-69%) and specificity of 80% (95%CI 73-85%). When comparing HIV-positive (N = 86) and HIV-negative (N = 206) patients, there was no significant difference in sensitivity (sensitivity difference 8%, 95%CI -11% to +24%, p = 0.4351) or specificity (specificity difference -9%, 95%CI -24% to +4%, p = 0.2051). Compared to the commercially available Alere Determine TB-LAM Ag test, the TB-LAM LFA prototype had improved sensitivity in both HIV-negative (difference 49%, 95%CI 37% to 59%, p<0.0001) and HIV-positive patients with CD4+ T-cell counts >200cells/µL (difference 59%, 95%CI 32% to 75%, p = 0.0009). This report is the first to show improved performance of a urine TB LAM test for HIV-negative patients in a high TB burden setting. We also offer potential assay refinement solutions that may further improve sensitivity and specificity.


Assuntos
Infecções por HIV/urina , Soropositividade para HIV/urina , Lipopolissacarídeos/urina , Tuberculose/urina , Adulto , Feminino , HIV/patogenicidade , Infecções por HIV/complicações , Infecções por HIV/microbiologia , Infecções por HIV/virologia , Soropositividade para HIV/microbiologia , Soropositividade para HIV/virologia , Humanos , Masculino , Testes Imediatos , Escarro/microbiologia , Escarro/virologia , Tuberculose/complicações , Tuberculose/microbiologia , Tuberculose/virologia , Uganda/epidemiologia , Adulto Jovem
10.
Nanoscale ; 12(42): 21788-21797, 2020 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-33103175

RESUMO

According to reports by the World Health Organization (WHO), cancer-related deaths reached almost 10 million in 2018. Nearly 65% of these deaths occurred in low- to middle-income countries, a trend that is bound to increase since cancer diagnostics are not currently considered a priority in resource-limited settings (RLS). Thus, cost-effective and specific cancer screening and diagnostics tools are in high demand, particularly in RLS. The selective isolation and up-concentration of rare cells while maintaining cell viability and preventing phenotypic changes is a powerful tool to allow accurate and sensitive downstream analysis. Here, multi-layer cellulose nanofibril-based coatings functionalized with anti-EpCAM antibodies on the surface of disposable microfluidic devices were optimized for specific capture of target cells, followed by efficient release without significant adverse effects. HCT 116 colon cancer cells were captured in a single step with >97% efficiency at 41.25 µL min-1 and, when spiked in whole blood, an average enrichment factor of ∼200-fold relative to white blood cells was achieved. The release of cells was performed by enzymatic digestion of the cellulose nanofibrils which had a negligible impact on cell viability. In particular, >80% of the cells were recovered with at least 97% viability in less than 30 min. Such performance paves the way to expand and improve clinical diagnostic applications by simplifying the isolation of circulating tumor cells (CTCs) and other rare cells directly from whole blood.


Assuntos
Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas , Células Neoplásicas Circulantes , Contagem de Células , Linhagem Celular Tumoral , Separação Celular , Celulose , Humanos
11.
J Appl Lab Med ; 4(2): 152-163, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31639660

RESUMO

BACKGROUND: The flow cytometry-based basophil activation test (BAT) is used for the diagnosis of allergic response. However, flow cytometry is time-consuming, requiring skilled personnel and cumbersome processing, which has limited its use in the clinic. Here, we introduce a novel microfluidic-based immunoaffinity BAT (miBAT) method. METHODS: The microfluidic device, coated with anti-CD203c, was designed to capture basophils directly from whole blood. The captured basophils are activated by anti-FcεRI antibody followed by optical detection of CD63 expression (degranulation marker). The device was first characterized using a basophil cell line followed by whole blood experiments. We evaluated the device with ex vivo stimulation of basophils in whole blood from healthy controls and patients with allergies and compared it with flow cytometry. RESULTS: The microfluidic device was capable of capturing basophils directly from whole blood followed by in vitro activation and quantification of CD63 expression. CD63 expression was significantly higher (P = 0.0002) in on-chip activated basophils compared with nonactivated cells. The difference in CD63 expression on anti-FcεRI-activated captured basophils in microfluidic chip was significantly higher (P = 0.03) in patients with allergies compared with healthy controls, and the results were comparable with flow cytometry analysis (P = 0.04). Furthermore, there was no significant difference of CD63% expression in anti-FcεRI-activated captured basophils in microfluidic chip compared with flow cytometry. CONCLUSIONS: We report on the miBAT. This device is capable of isolating basophils directly from whole blood for on-chip activation and detection. The new miBAT method awaits validation in larger patient populations to assess performance in diagnosis and monitoring of patients with allergies at the point of care.


Assuntos
Teste de Degranulação de Basófilos/instrumentação , Hipersensibilidade/diagnóstico , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , Testes Imediatos , Teste de Degranulação de Basófilos/métodos , Basófilos/imunologia , Linhagem Celular , Separação Celular/instrumentação , Separação Celular/métodos , Citometria de Fluxo , Humanos , Hipersensibilidade/sangue , Hipersensibilidade/imunologia , Técnicas Analíticas Microfluídicas/métodos , Microscopia de Fluorescência , Diester Fosfórico Hidrolases/imunologia , Pirofosfatases/imunologia
12.
J Proteomics ; 172: 165-172, 2018 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-28942014

RESUMO

Mass spectrometry-based proteomics benefits from efficient digestion of protein samples. In this study, trypsin was immobilized on nanoporous anodized alumina membranes to create an enzyme reactor suitable for peptide mass fingerprinting. The membranes were derivatized with 3-aminopropyltriethoxysilane and the amino groups were activated with carbonyldiimidazole to allow coupling of porcine trypsin via ε-amino groups. The function was assessed using the artificial substrate Nα-Benzoyl-L-arginine 4-nitroanilide hydrochloride, bovine ribonuclease A and a human plasma sample. A 10-membrane flow-through reactor was used for fragmentation and MS analysis after a single pass of substrate both by collection of product and subsequent off-line analysis, and by coupling on-line to the instrument. The peptide pattern allowed correct identification of the single target protein in both cases, and of >70 plasma proteins in single pass mode followed by LC-MS analysis. The reactor retained 76% of the initial activity after 14days of storage and repeated use at room temperature. SIGNIFICANCE: This manuscript describes the design of a stable enzyme reactor that allows efficient and fast digestion with negligible leakage of enzyme and enzyme fragments. The high stability facilitates the use in an online-setup with MS detection since it allows the processing of multiple samples within an extended period of time without replacement.


Assuntos
Reatores Biológicos/normas , Desenho de Equipamento , Espectrometria de Massas/métodos , Mapeamento de Peptídeos/métodos , Óxido de Alumínio , Animais , Enzimas Imobilizadas , Humanos , Membranas Artificiais , Nanoporos , Suínos , Tripsina
13.
Methods Mol Biol ; 1547: 175-186, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28044296

RESUMO

Bacterial blood stream infection (BSI) potentially leads to life-threatening clinical conditions and medical emergencies such as severe sepsis, septic shock, and multi organ failure syndrome. Blood culturing is currently the gold standard for the identification of microorganisms and, although it has been automated over the decade, the process still requires 24-72 h to complete. This long turnaround time, especially for the identification of antimicrobial resistance, is driving the development of rapid molecular diagnostic methods. Rapid detection of microbial pathogens in blood related to bloodstream infections will allow the clinician to decide on or adjust the antimicrobial therapy potentially reducing the morbidity, mortality, and economic burden associated with BSI. For molecular-based methods, there is a lot to gain from an improved and straightforward method for isolation of bacteria from whole blood for downstream processing.We describe a microfluidic-based sample-preparation approach that rapidly and selectively lyses all blood cells while it extracts intact bacteria for downstream analysis. Whole blood is exposed to a mild detergent, which lyses most blood cells, and then to osmotic shock using deionized water, which eliminates the remaining white blood cells. The recovered bacteria are 100 % viable, which opens up possibilities for performing drug susceptibility tests and for nucleic-acid-based molecular identification.


Assuntos
Bacteriemia/diagnóstico , Bactérias , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/métodos , Técnicas de Diagnóstico Molecular/métodos , Bacteriemia/microbiologia , Bactérias/genética , Desenho de Equipamento , Citometria de Fluxo/métodos , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Microfluídica/instrumentação , Técnicas de Diagnóstico Molecular/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito
14.
Biomicrofluidics ; 8(3): 034117, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-25379077

RESUMO

Passive particle focusing based on inertial microfluidics was recently introduced as a high-throughput alternative to active focusing methods that require an external force field to manipulate particles. In inertial microfluidics, dominant inertial forces cause particles to move across streamlines and occupy equilibrium positions along the faces of walls in flows through straight micro channels. In this study, we systematically analyzed the addition of secondary Dean forces by introducing curvature and show how randomly distributed particles entering a simple u-shaped curved channel are focused to a fixed lateral position exiting the curvature. We found the lateral particle focusing position to be fixed and largely independent of radius of curvature and whether particles entering the curvature are pre-focused (at equilibrium) or randomly distributed. Unlike focusing in straight channels, where focusing typically is limited to channel cross-sections in the range of particle size to create single focusing point, we report here particle focusing in a large cross-section area (channel aspect ratio 1:10). Furthermore, we describe a simple u-shaped curved channel, with single inlet and four outlets, for filtration applications. We demonstrate continuous focusing and filtration of 10 µm particles (with >90% filtration efficiency) from a suspension mixture at throughputs several orders of magnitude higher than flow through straight channels (volume flow rate of 4.25 ml/min). Finally, as an example of high throughput cell processing application, white blood cells were continuously processed with a filtration efficiency of 78% with maintained high viability. We expect the study will aid in the fundamental understanding of flow through curved channels and open the door for the development of a whole set of bio-analytical applications.

15.
Lab Chip ; 13(8): 1578-85, 2013 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-23440071

RESUMO

We present a novel "Lab-on-DVD" system and demonstrate its capability for rapid and low-cost HIV diagnostics by counting CD4+ cells isolated from whole blood. We show that a commercial DVD drive can, with certain modifications, be turned into an improved DVD-based laser scanning microscope (DVD-LSM). The system consists of a multi-layered disposable polymer disc and a modified commercial DVD reader with rotational control for sample handling, temperature control for optimized bioassay, a photodiode array for detection, and software for signal processing and user interface - all the necessary components required for a truly integrated lab-on-a-chip system, with the capability to deliver high-resolution images down to 1 µm in size. Using discs modified with antibodies, we specifically captured CD4+ cells from whole blood, demonstrating single cell resolution imaging. The novel integrated DVD platform with sub-micron image resolution brings, for the first time, affordable cellular diagnostic testing to the point-of-care and should be readily applicable at resource-limited settings.


Assuntos
Linfócitos T CD4-Positivos/citologia , Infecções por HIV/diagnóstico , Técnicas Analíticas Microfluídicas/instrumentação , Microscopia Confocal , Anticorpos Imobilizados/imunologia , Contagem de Linfócito CD4 , Linhagem Celular , Separação Celular/instrumentação , Separação Celular/métodos , Eletrônica , Citometria de Fluxo , Humanos , Técnicas Analíticas Microfluídicas/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Software , Temperatura
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa