Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Abdom Radiol (NY) ; 42(3): 759-765, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28084544

RESUMO

PURPOSE: To compare dual-energy computed tomography (DECT) aortography using a 70% reduced iodine dose to single-energy CT (SECT) aortography using a standard iodine dose in the same patient. METHODS: Twenty-one patients with a prior SECT aortography using standard iodine dose had DECT aortography using 70% reduced iodine dose. Section 120 kVp images were compared to DECT images reconstructed at both 50 and 77 keV. Reviewers measured image noise and attenuation in the aorta at eight locations from proximal to distal and subjectively scored vascular enhancement on a four-point scale. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The volume CT dose index (CTDIvol) for each exam was recorded. RESULTS: Mean iodine dose was 50 g for SECT and 15 g for DECT (70% reduction). Mean aortic attenuation was similar for section 120 kVp (350 ± 67 HU) and DECT 50 keV (338 ± 57 HU, p = 0.547) but was lower at 77 keV (152 ± 23 HU). Measured image noise was greatest at 50 keV (12 ± 5 HU) and was lowest at 77 keV (7 ± 2 HU, p > 0.001). There was no difference in SNR or CNR between 120 kVp and 50 keV (p > 0.05). Mean subjective vascular enhancement scores for SECT were between good and excellent (3.33-3.69), and for DECT at 50 keV were between moderate and good (2.54-2.93, p < 0.0001). CTDIvol was 13.6 mGy for SECT and 13.1 mGy for DECT (p = 0.637). CONCLUSION: 70% Reduced iodine DECT aortography may result in similar aortic attenuation, CNR, SNR, and lower although acceptable subjective image scores when compared to standard iodine SECT aortography in the same patient.


Assuntos
Aneurisma Aórtico/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Iohexol/administração & dosagem , Ácidos Tri-Iodobenzoicos/administração & dosagem , Idoso , Aneurisma Aórtico/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Razão Sinal-Ruído
2.
Clin Imaging ; 40(6): 1213-1218, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27616154

RESUMO

PURPOSE: This study aims to compare transcatheter aortic valve replacement (TAVR) planning on 16 cm wide-detector computed tomography (CT) to TAVR planning on 4 cm detector CT. MATERIALS AND METHODS: A total of 36 patients who had TAVR planning axial CT on a wide-detector scanner (protocol 1) were compared to 36 patients who had helical 4 cm detector CT (protocol 2). RESULTS: Vascular attenuation was greater for protocol 1, but image noise, contrast-to-noise ratio, and signal-to-noise ratio were the same. Radiation dose was lower and iodine dose was less for protocol 1. CONCLUSION: Protocol 1 had greater vascular attenuation and similar image quality but lower radiation and less iodine compared to protocol 2.


Assuntos
Meios de Contraste/administração & dosagem , Aumento da Imagem , Iodo/administração & dosagem , Doses de Radiação , Tomografia Computadorizada Espiral/métodos , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter , Idoso , Feminino , Humanos , Masculino , Estudos Retrospectivos , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa