Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
Perfusion ; 38(1): 197-199, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-34378442

RESUMO

Infective endocarditis (IE) carries a high risk of morbidity and mortality. Timely diagnosis, effective treatment and prompt recognition of complications are essential to favourable patient outcomes. A collaborative, multidisciplinary team approach to the management of IE has been shown to improve prognosis. However, the clinical heterogeneity of IE and atypical presentations pose challenges to the endocarditis team. We present a case highlighting the role of valve histopathology in suspected IE, where there may be diagnostic uncertainty.


Assuntos
Endocardite Bacteriana , Endocardite , Humanos , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/complicações , Endocardite Bacteriana/microbiologia , Endocardite/diagnóstico , Resultado do Tratamento , Prognóstico
2.
Perfusion ; 36(6): 547-558, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33427055

RESUMO

The COVID-19 pandemic has altered our approach to inpatient echocardiography delivery. There is now a greater focus to address key clinical questions likely to make an immediate impact in management, particularly during the period of widespread infection. Handheld echocardiography (HHE) can be used as a first-line assessment tool, limiting scanning time and exposure to high viral load. This article describes a potential role for HHE during a pandemic. We propose a protocol with a reporting template for a focused core dataset necessary in delivering an acute echocardiography service in the setting of a highly contagious disease, minimising risk to the operator. We cover the scenarios typically encountered in the acute cardiology setting and how an expert trained echocardiography team can identify such pathologies using a limited imaging format and include cardiac presentations encountered in those patients acutely unwell with COVID-19.


Assuntos
COVID-19 , Cardiologia , Ecocardiografia , Humanos , Pandemias , SARS-CoV-2
3.
Curr Cardiol Rep ; 22(9): 80, 2020 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-32648007

RESUMO

PURPOSE OF REVIEW: The TAVR procedure is a well-established therapy for patients with severe aortic stenosis at intermediate/high risk for surgery and a potential treatment for low-risk patients. It is much less invasive with short hospital stays and presents similar results compared with SAVR. Different "minimalist approach strategies" were proposed in order to obtain this performance. In these settings, transesophageal echocardiography (TEE) became less relevant for the TAVR procedure. The present review provides an update regarding the safety of TAVR without intraprocedural TEE. RECENT FINDINGS: Transthoracic echocardiography and fluoroscopy are the primary imaging tools during TAVR. Several studies proved that TAVR under local anesthesia without TEE is as safe as that performed under TEE guidance. However, not all patients have a proper window for TTE, and particular cases with complex anatomy can benefit from TEE support during the intervention. Intraprocedural TEE no longer plays a crucial role in the TAVR procedure, but in some instances, it remains of great help to detect and avoid complications.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Ecocardiografia Transesofagiana , Humanos , Resultado do Tratamento
4.
Curr Cardiol Rep ; 21(5): 37, 2019 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-30924027

RESUMO

PURPOSE OF REVIEW: This review aims to provide an updated overview and a clinical perspective on novel transcatheter tricuspid valve interventions (TTVI), highlighting potential challenges and future directions. RECENT FINDINGS: Severe tricuspid regurgitation (TR) is a predictor of mortality. However, a sizeable number of patients remain untreated until the end-stage when cardiac surgery presents a prohibitive risk. The emergent need in finding a treatment for patients with TR, deemed for surgery options, has encouraged the development of TTVI. These procedures mimic classical surgery techniques and are mainly divided in four categories: annuloplasty and coaptation devices, edge-to-edge techniques and transcatheter tricuspid valve replacement. Early studies showed promising results, but long-term follow-up data are not available. For patients with severe TR and high surgical risk, several percutaneous options are available. However, these therapies are in a growing phase and bigger studies and long term follow-up are needed to prove their efficacy.


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Humanos , Resultado do Tratamento
5.
Circulation ; 134(13): 934-44, 2016 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-27587432

RESUMO

BACKGROUND: Paravalvular leak (PVL) occurs in 5% to 17% of patients following surgical valve replacement. Percutaneous device closure represents an alternative to repeat surgery. METHODS: All UK and Ireland centers undertaking percutaneous PVL closure submitted data to the UK PVL Registry. Data were analyzed for association with death and major adverse cardiovascular events (MACE) at follow-up. RESULTS: Three hundred eight PVL closure procedures were attempted in 259 patients in 20 centers (2004-2015). Patient age was 67±13 years; 28% were female. The main indications for closure were heart failure (80%) and hemolysis (16%). Devices were successfully implanted in 91% of patients, via radial (7%), femoral arterial (52%), femoral venous (33%), and apical (7%) approaches. Nineteen percent of patients required repeat procedures. The target valve was mitral (44%), aortic (48%), both (2%), pulmonic (0.4%), or transcatheter aortic valve replacement (5%). Preprocedural leak was severe (61%), moderate (34%), or mild (5.7%) and was multiple in 37%. PVL improved postprocedure (P<0.001) and was none (33.3%), mild (41.4%), moderate (18.6%), or severe (6.7%) at last follow-up. Mean New York Heart Association class improved from 2.7±0.8 preprocedure to 1.6±0.8 (P<0.001) after a median follow-up of 110 (7-452) days. Hospital mortality was 2.9% (elective), 6.8% (in-hospital urgent), and 50% (emergency) (P<0.001). MACE during follow-up included death (16%), valve surgery (6%), late device embolization (0.4%), and new hemolysis requiring transfusion (1.6%). Mitral PVL was associated with higher MACE (hazard ratio [HR], 1.83; P=0.011). Factors independently associated with death were the degree of persisting leak (HR, 2.87; P=0.037), New York Heart Association class (HR, 2.00; P=0.015) at follow-up and baseline creatinine (HR, 8.19; P=0.001). The only factor independently associated with MACE was the degree of persisting leak at follow-up (HR, 3.01; P=0.002). CONCLUSION: Percutaneous closure of PVL is an effective procedure that improves PVL severity and symptoms. Severity of persisting leak at follow-up is independently associated with both MACE and death. Percutaneous closure should be considered as an alternative to repeat surgery.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Mitral/cirurgia , Complicações Pós-Operatórias/etiologia , Falha de Prótese/efeitos adversos , Substituição da Valva Aórtica Transcateter , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Feminino , Insuficiência Cardíaca/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Irlanda , Masculino , Pessoa de Meia-Idade , Reoperação/métodos , Substituição da Valva Aórtica Transcateter/métodos , Reino Unido
6.
Circulation ; 129(23): 2395-402, 2014 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-24668286

RESUMO

BACKGROUND: Postinfarction ventricular septal defect carries a grim prognosis. Surgical repair offers reasonable outcomes in patients who survive a healing phase. Percutaneous device implantation represents a potentially attractive early alternative. METHODS AND RESULTS: Postinfarction ventricular septal defect closure was attempted in 53 patients from 11 centers (1997-2012; aged 72±11 years; 42% female). Nineteen percent had previous surgical closure. Myocardial infarction was anterior (66%) or inferior (34%). Time from myocardial infarction to closure procedure was 13 (first and third quartiles, 5-54) days. Devices were successfully implanted in 89% of patients. Major immediate complications included procedural death (3.8%) and emergency cardiac surgery (7.5%). Immediate shunt reduction was graded as complete (23%), partial (62%), or none (15%). Median length of stay after the procedure was 5.0 (2.0-9.0) days. Fifty-eight percent survived to discharge and were followed up for 395 (63-1522) days, during which time 4 additional patients died (7.5%). Factors associated with death after postinfarction ventricular septal defect closure included the following: age (hazard ratio [HR]=1.04; P=0.039), female sex (HR=2.33; P=0.043), New York Heart Association class IV (HR=4.42; P=0.002), cardiogenic shock (HR=3.75; P=0.003), creatinine (HR=1.007; P=0.003), defect size (HR=1.09; P=0.026), inotropes (HR=4.18; P=0.005), and absence of revascularization therapy for presenting myocardial infarction (HR=3.28; P=0.009). Prior surgical closure (HR=0.12; P=0.040) and immediate shunt reduction (HR=0.49; P=0.037) were associated with survival. CONCLUSIONS: Percutaneous closure of postinfarction ventricular septal defect is a reasonably effective treatment for these extremely high-risk patients. Mortality remains high, but patients who survive to discharge do well in the longer term.


Assuntos
Cateterismo Cardíaco , Comunicação Interventricular/mortalidade , Comunicação Interventricular/cirurgia , Infarto do Miocárdio/mortalidade , Dispositivo para Oclusão Septal/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Comunicação Interventricular/etiologia , Mortalidade Hospitalar , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/complicações , Prognóstico , Fatores de Risco , Choque Cardiogênico/etiologia , Choque Cardiogênico/mortalidade , Reino Unido/epidemiologia
7.
Echocardiography ; 31(6): 736-43, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24303794

RESUMO

BACKGROUND: Assessment of transmural scar at the site of latest mechanical activation is relevant to maximize outcomes in cardiac resynchronization therapy (CRT). Few studies have assessed the ability of speckle tracking echocardiography (STE)-derived short-axis strain to identify segmental myocardial scar, defined by contrast-enhanced cardiac magnetic resonance imaging (CMR), in patients referred for CRT. METHODS: A total of 26 patients with ischemic cardiomyopathy who underwent preprocedure echocardiography and CMR were studied. Extent of transmural scar was assessed using contrast-enhanced CMR and corresponding peak segmental radial and circumferential strains were derived using two-dimensional (2D) STE. Total left ventricle (LV) scar volume was compared with parameters of global strain. CRT response was defined as >15% reduction in LV end systolic volume (LVESV) at 6 months. RESULTS: Speckle tracking short-axis strain analysis was technically possible in over 90% of LV segments. Applying a segmental radial strain cutoff value of 10% distinguished segments with >50% scar area with a high negative predictive value (98%). Global longitudinal strain <-5% predicted CRT response. CONCLUSIONS: Two-dimensional STE offers potential to characterize dysfunctional myocardium and define segmental scar offering an integrated imaging approach to guide LV lead placement for CRT.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/terapia , Cicatriz/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Isquemia Miocárdica/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Cardiomiopatias/complicações , Cicatriz/complicações , Cicatriz/terapia , Ecocardiografia/métodos , Feminino , Humanos , Masculino , Isquemia Miocárdica/etiologia , Isquemia Miocárdica/terapia , Encaminhamento e Consulta , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/prevenção & controle
8.
Echo Res Pract ; 11(1): 16, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38825710

RESUMO

Impairment of left ventricular (LV) diastolic function is common amongst those with left heart disease and is associated with significant morbidity. Given that, in simple terms, the ventricle can only eject the volume with which it fills and that approximately one half of hospitalisations for heart failure (HF) are in those with normal/'preserved' left ventricular ejection fraction (HFpEF) (Bianco et al. in JACC Cardiovasc Imaging. 13:258-271, 2020. 10.1016/j.jcmg.2018.12.035), where abnormalities of ventricular filling are the cause of symptoms, it is clear that the assessment of left ventricular diastolic function (LVDF) is crucial for understanding global cardiac function and for identifying the wider effects of disease processes. Invasive methods of measuring LV relaxation and filling pressures are considered the gold-standard for investigating diastolic function. However, the high temporal resolution of trans-thoracic echocardiography (TTE) with widely validated and reproducible measures available at the patient's bedside and without the need for invasive procedures involving ionising radiation have established echocardiography as the primary imaging modality. The comprehensive assessment of LVDF is therefore a fundamental element of the standard TTE (Robinson et al. in Echo Res Pract7:G59-G93, 2020. 10.1530/ERP-20-0026). However, the echocardiographic assessment of diastolic function is complex. In the broadest and most basic terms, ventricular diastole comprises an early filling phase when blood is drawn, by suction, into the ventricle as it rapidly recoils and lengthens following the preceding systolic contraction and shortening. This is followed in late diastole by distension of the compliant LV when atrial contraction actively contributes to ventricular filling. When LVDF is normal, ventricular filling is achieved at low pressure both at rest and during exertion. However, this basic description merely summarises the complex physiology that enables the diastolic process and defines it according to the mechanical method by which the ventricles fill, overlooking the myocardial function, properties of chamber compliance and pressure differentials that determine the capacity for LV filling. Unlike ventricular systolic function where single parameters are utilised to define myocardial performance (LV ejection fraction (LVEF) and Global Longitudinal Strain (GLS)), the assessment of diastolic function relies on the interpretation of multiple myocardial and blood-flow velocity parameters, along with left atrial (LA) size and function, in order to diagnose the presence and degree of impairment. The echocardiographic assessment of diastolic function is therefore multifaceted and complex, requiring an algorithmic approach that incorporates parameters of myocardial relaxation/recoil, chamber compliance and function under variable loading conditions and the intra-cavity pressures under which these processes occur. This guideline outlines a structured approach to the assessment of diastolic function and includes recommendations for the assessment of LV relaxation and filling pressures. Non-routine echocardiographic measures are described alongside guidance for application in specific circumstances. Provocative methods for revealing increased filling pressure on exertion are described and novel and emerging modalities considered. For rapid access to the core recommendations of the diastolic guideline, a quick-reference guide (additional file 1) accompanies the main guideline document. This describes in very brief detail the diastolic investigation in each patient group and includes all algorithms and core reference tables.

9.
Echo Res Pract ; 10(1): 23, 2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37964335

RESUMO

Ultrasound contrast agents (UCAs) have a well-established role in clinical cardiology. Contrast echocardiography has evolved into a routine technique through the establishment of contrast protocols, an excellent safety profile, and clinical guidelines which highlight the incremental prognostic utility of contrast enhanced echocardiography. This document aims to provide practical guidance on the safe and effective use of contrast; reviews the role of individual staff groups; and training requirements to facilitate its routine use in the echocardiography laboratory.

10.
Front Cardiovasc Med ; 9: 793267, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36386324

RESUMO

Tricuspid valve pathophysiology is not well-understood. Emergence of novel transcatheter tricuspid therapies has fueled the requirements for improved imaging visualization techniques and interventional imaging physician skillsets in guiding these complex transcatheter procedures. There is growing understanding on the clinical significance of tricuspid regurgitation which expanded the interest for percutaneous tricuspid valve interventions. The present review concentrates on three essential aspects of tricuspid valve pathophysiology: anatomical considerations for tricuspid interventions, optimal timing of tricuspid interventions by imaging guidance, and the role of interventional imaging physicians' skillset and knowledge in this field.

11.
Cardiovasc Revasc Med ; 36: 153-163, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34366296

RESUMO

Percutaneous closure of paravalvar leaks (PVLs) was once only performed in extreme or non-surgical risk cases not suitable for redo-surgery with tissue or mechanical valves. This technique is now the treatment of choice with long term outcomes that are better than redo operations.123 As interventionalists become more familiar with using PVL devices, more off label device use has been reported in non-surgical cases involving complex native mitral valve regurgitation (NVMR). In this review, we appraise the literature regarding percutaneous treatment of paravalvar leaks and more recently esoteric off label use. We also describe two recent challenging cases where percutaneous devices were used to treat severe leaks that developed as a sequela of previous infective endocarditis. We also provide specific recommendations regarding periprocedural strategy and focus on the importance of device choice to provide an optimal outcome.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Catéteres , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
12.
J Soc Cardiovasc Angiogr Interv ; 1(4): 100349, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35992189

RESUMO

Background: Transcatheter aortic valve replacement (TAVR) is the treatment of choice for patients with severe aortic stenosis who are at a moderate or higher surgical risk. Stroke is a recognised and serious complication of TAVR, and it is important to identify patients at higher stroke risk. This study aims to discover if aortic valve calcium score calculated from pre-TAVR computed tomography is associated with acute stroke in TAVR patients. Methods: We conducted a retrospective, observational cohort study of 433 consecutive patients undergoing TAVR between January 2017 and December 2019 at the Hammersmith Hospital. Results: This cohort had a median age of 83 years (interquartile range, 78-87), and 52.7% were male. Fifty-two patients (12.0%) had a history of previous stroke or transient ischemic attack. Median aortic valve calcium score was 2145 (interquartile range, 1427-3247) Agatston units. Twenty-two patients had a stroke up to the time of discharge (5.1%). In a logistic regression model, aortic valve calcium score was significantly associated with acute stroke (odds ratio [OR], 1.26; 95% confidence interval [CI], 1.01-1.53; P = .02). Acute stroke was also significantly associated with peripheral arterial disease (OR, 4.32; 95% CI, 1.65-10.65; P = .0018) and a longer procedure time (OR, 1.01; 95% CI, 1.00-1.02; P = .0006). Conclusions: Aortic valve calcium score from pre-TAVR computed tomography is an independent risk factor for acute stroke in the TAVR population. This is an additional clinical value of the pre-TAVR aortic valve calcium score and should be considered when discussing periprocedural stroke risk.

13.
Lancet Digit Health ; 4(2): e117-e125, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34998740

RESUMO

BACKGROUND: Most patients who have heart failure with a reduced ejection fraction, when left ventricular ejection fraction (LVEF) is 40% or lower, are diagnosed in hospital. This is despite previous presentations to primary care with symptoms. We aimed to test an artificial intelligence (AI) algorithm applied to a single-lead ECG, recorded during ECG-enabled stethoscope examination, to validate a potential point-of-care screening tool for LVEF of 40% or lower. METHODS: We conducted an observational, prospective, multicentre study of a convolutional neural network (known as AI-ECG) that was previously validated for the detection of reduced LVEF using 12-lead ECG as input. We used AI-ECG retrained to interpret single-lead ECG input alone. Patients (aged ≥18 years) attending for transthoracic echocardiogram in London (UK) were recruited. All participants had 15 s of supine, single-lead ECG recorded at the four standard anatomical positions for cardiac auscultation, plus one handheld position, using an ECG-enabled stethoscope. Transthoracic echocardiogram-derived percentage LVEF was used as ground truth. The primary outcome was performance of AI-ECG at classifying reduced LVEF (LVEF ≤40%), measured using metrics including the area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity, with two-sided 95% CIs. The primary outcome was reported for each position individually and with an optimal combination of AI-ECG outputs (interval range 0-1) from two positions using a rule-based approach and several classification models. This study is registered with ClinicalTrials.gov, NCT04601415. FINDINGS: Between Feb 6 and May 27, 2021, we recruited 1050 patients (mean age 62 years [SD 17·4], 535 [51%] male, 432 [41%] non-White). 945 (90%) had an ejection fraction of at least 40%, and 105 (10%) had an ejection fraction of 40% or lower. Across all positions, ECGs were most frequently of adequate quality for AI-ECG interpretation at the pulmonary position (979 [93·3%] of 1050). Quality was lowest for the aortic position (846 [80·6%]). AI-ECG performed best at the pulmonary valve position (p=0·02), with an AUROC of 0·85 (95% CI 0·81-0·89), sensitivity of 84·8% (76·2-91·3), and specificity of 69·5% (66·4-72·6). Diagnostic odds ratios did not differ by age, sex, or non-White ethnicity. Taking the optimal combination of two positions (pulmonary and handheld positions), the rule-based approach resulted in an AUROC of 0·85 (0·81-0·89), sensitivity of 82·7% (72·7-90·2), and specificity of 79·9% (77·0-82·6). Using AI-ECG outputs from these two positions, a weighted logistic regression with l2 regularisation resulted in an AUROC of 0·91 (0·88-0·95), sensitivity of 91·9% (78·1-98·3), and specificity of 80·2% (75·5-84·3). INTERPRETATION: A deep learning system applied to single-lead ECGs acquired during a routine examination with an ECG-enabled stethoscope can detect LVEF of 40% or lower. These findings highlight the potential for inexpensive, non-invasive, workflow-adapted, point-of-care screening, for earlier diagnosis and prognostically beneficial treatment. FUNDING: NHS Accelerated Access Collaborative, NHSX, and the National Institute for Health Research.


Assuntos
Inteligência Artificial , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico , Exame Físico/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Estetoscópios , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Redes Neurais de Computação , Estudos Prospectivos , Reino Unido
14.
Eur J Echocardiogr ; 12(10): i25-31, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21998465

RESUMO

Stroke is a leading cause of morbidity and mortality and is the third commonest cause of death in Europe. Clinical history examination and basic investigations including an electrocardiogram may shed light on the potential cardiac cause. Echocardiography plays a pivotal role in the assessment of embolic stroke. The hierarchy of echocardiography investigations begins with a standard transthoracic echocardiography study and may be proceeded by a bubble contrast transthoracic and a transoesophageal echo study. This article discusses the crucial role echocardiography has assumed in the assessment of stroke patients and describes the cardiac sources responsible.


Assuntos
Ecocardiografia , Embolia/diagnóstico por imagem , Cardiopatias/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Doenças da Aorta/complicações , Doenças da Aorta/diagnóstico por imagem , Embolia/complicações , Cardiopatias/complicações , Humanos
15.
Echo Res Pract ; 8(1): G87-G136, 2021 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-34061768

RESUMO

Mitral valve disease is common. Mitral regurgitation is the second most frequent indication for valve surgery in Europe and despite the decline of rheumatic fever in Western societies, mitral stenosis of any aetiology is a regular finding in all echo departments. Mitral valve disease is, therefore, one of the most common pathologies encountered by echocardiographers, as both a primary indication for echocardiography and a secondary finding when investigating other cardiovascular disease processes. Transthoracic, transoesophageal and exercise stress echocardiography play a crucial role in the assessment of mitral valve disease and are essential to identifying the aetiology, mechanism and severity of disease, and for helping to determine the appropriate timing and method of intervention. This guideline from the British Society of Echocardiography (BSE) describes the assessment of mitral regurgitation and mitral stenosis, and replaces previous BSE guidelines that describe the echocardiographic assessment of mitral anatomy prior to mitral valve repair surgery and percutaneous mitral valvuloplasty. It provides a comprehensive description of the imaging techniques (and their limitations) employed in the assessment of mitral valve disease. It describes a step-wise approach to identifying: aetiology and mechanism, disease severity, reparability and secondary effects on chamber geometry, function and pressures. Advanced echocardiographic techniques are described for both transthoracic and transoesophageal modalities, including TOE and exercise testing.

16.
Echo Res Pract ; 8(1): G19-G59, 2021 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-33709955

RESUMO

The guideline provides a practical step-by-step guide in order to facilitate high-quality echocardiographic studies of patients with aortic stenosis. In addition, it addresses commonly encountered yet challenging clinical scenarios and covers the use of advanced echocardiographic techniques, including TOE and Dobutamine stress echocardiography in the assessment of aortic stenosis.

17.
Cardiol Res Pract ; 2021: 5565200, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34367691

RESUMO

BACKGROUND: Infective endocarditis (IE) is challenging to manage in the COVID-19 lockdown period, in part given its reliance on echocardiography for diagnosis and management and the associated virus transmission risks to patients and healthcare workers. This study assesses utilisation of the endocarditis team (ET) in limiting routine echocardiography, especially transoesophageal echocardiography (TOE), in patients with suspected IE, and explores the effect on clinical outcomes. METHODS: All patients discussed at the ET meeting at Imperial College Healthcare NHS Trust during the first lockdown in the UK (23 March to 8 July 2020) were prospectively included and analysed in this observational study. RESULTS: In total, 38 patients were referred for ET review (71% male, median age 54 [interquartile range 48, 65.5] years). At the time of ET discussion, 21% had no echo imaging, 16% had point-of-care ultrasound only, and 63% had formal TTE. In total, only 16% underwent TOE. The ability of echocardiography, in those where it was performed, to affect IE diagnosis according to the Modified Duke Criteria was significant (p=0.0099); however, sensitivity was not affected. All-cause mortality was 17% at 30 days and 25% at 12 months from ET discussion in those with confirmed IE. CONCLUSION: Limiting echocardiography in patients with a low pretest probability (not probable or definite IE according to the Modified Duke Criteria) did not affect the diagnostic ability of the Modified Duke Criteria to rule out IE in this small study. Moreover, restricting nonessential echocardiography, and importantly TOE, in patients with suspected IE through use of the ET did not impact all-cause mortality.

18.
Front Cardiovasc Med ; 8: 585415, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33614745

RESUMO

Secondary mitral regurgitation (MR) occurs despite structurally normal valve apparatus due to an underlying disease of the myocardium leading to disruption of the balance between tethering and closing forces with ensuing failure of leaflet coaptation. In patients with heart failure (HF) and left ventricular dysfunction, secondary MR is independently associated with poor outcome, yet prognostic benefits related to the correction of MR have remained elusive. Surgery is not recommended for the correction of secondary MR outside coronary artery bypass grafting. Percutaneous mitral valve repair (PMVR) with MitraClip implantation has recently evolved as a new transcatheter treatment option of inoperable or high-risk patients with severe MR, with promising results supporting the extension of guideline recommendations. MitraClip is highly effective in reducing secondary MR in HF patients. However, the derived clinical benefit is still controversial as two randomized trials directly comparing PMVR vs. optimal medical therapy in severe secondary MR yielded virtually opposite conclusions. We reviewed current evidence to identify predictors of PMVR-related outcomes in secondary MR useful to improve the timing and the selection of patients who would derive maximal benefit from MitraClip intervention. Beyond mitral valve anatomy, optimal candidate selection should rely on a comprehensive diagnostic workup and a fine-tuned risk stratification process aimed at (i) recognizing the substantial heterogeneity of secondary MR and its complex interaction with the myocardium, (ii) foreseeing hemodynamic consequences of PMVR, (iii) anticipating futility and (iv) improving symptoms, quality of life and overall survival.

19.
Brachytherapy ; 20(3): 631-637, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33642174

RESUMO

PURPOSE: The noninvasive image-guided breast brachytherapy (NIBB) technique is a novel noninvasive yet targeted method for accelerated partial breast irradiation. We established a multi-institutional registry to evaluate the toxicity and efficacy of this technique across various practice settings. METHODS AND MATERIALS: Institutions using the NIBB technique were invited to participate. Data for acute/late toxicity, cosmetic outcome, and tumor recurrence were collected. Toxicity and cosmetic outcome were graded based on the Common Terminology Criteria for Adverse Events version 3.0 and NRG/Radiation Therapy Oncology Group scale, respectively. Treatment variables were analyzed for association with outcomes. RESULTS: A total of 252 patients from eight institutions were analyzed. The median age was 69 years. The mean tumor size was 1.1 cm (0.1-4.0 cm). Treatment was delivered 10 fractions (34-36 Gy) in 75% and five fractions (28.5 Gy) in 22%. B.i.d. fractionation was used in 9%. Acute radiation dermatitis was Grade 0-1, 2, and 3 in 77%, 19%, and 4%, respectively. One hundred ninety-one patients with a median followup of 18 months (4-72 months) were evaluable for late outcomes. Late toxicity Grades 2 and 3 were observed in 8.8% and 1%, respectively. Cosmetic outcome was excellent, good, and fair/poor in 62%, 36%, and 2%, respectively. B.i.d. fractionation was associated with higher acute and late toxicity. Second-generation applicators were associated with lower late toxicity and better cosmetic outcome. Actuarial freedom from ipsilateral breast tumor recurrence and true recurrence were 98.3% and 98.3% at 2 years and 90.9% and 95.4% at 5 years, respectively. CONCLUSIONS: Accelerated partial breast irradiation using NIBB was well tolerated with a low rate of acute and late toxicity across various practice settings. Ipsilateral breast tumor recurrence and cosmetic outcomes were favorable. b.i.d. fractionation was associated with higher toxicity. Longer followup is needed to confirm late endpoints.


Assuntos
Braquiterapia , Neoplasias da Mama , Idoso , Braquiterapia/métodos , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Estudos de Viabilidade , Feminino , Humanos , Mastectomia Segmentar , Recidiva Local de Neoplasia/radioterapia , Dosagem Radioterapêutica , Sistema de Registros , Resultado do Tratamento
20.
Echo Res Pract ; 8(1): G1-G18, 2021 03 31.
Artigo em Inglês | MEDLINE | ID: mdl-34106116

RESUMO

The subspecialty of cardio-oncology aims to reduce cardiovascular morbidity and mortality in patients with cancer or following cancer treatment. Cancer therapy can lead to a variety of cardiovascular complications, including left ventricular systolic dysfunction, pericardial disease, and valvular heart disease. Echocardiography is a key diagnostic imaging tool in the diagnosis and surveillance for many of these complications. The baseline assessment and subsequent surveillance of patients undergoing treatment with anthracyclines and/or human epidermal growth factor (EGF) receptor (HER) 2-positive targeted treatment (e.g. trastuzumab and pertuzumab) form a significant proportion of cardio-oncology patients undergoing echocardiography. This guideline from the British Society of Echocardiography and British Cardio-Oncology Society outlines a protocol for baseline and surveillance echocardiography of patients undergoing treatment with anthracyclines and/or trastuzumab. The methodology for acquisition of images and the advantages and disadvantages of techniques are discussed. Echocardiographic definitions for considering cancer therapeutics-related cardiac dysfunction are also presented.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa