Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Analyst ; 135(3): 608-14, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20174718

RESUMO

We report herein the amperometric immunosensor for antibodies to Plasmodium falciparum histidine rich protein-2 (PfHRP-2). Screen-printed electrodes (SPEs) were modified with alumina sol-gel (Al(2)O(3) sol-gel) derived film and gold nanoparticles i.e. AuNPs/Al(2)O(3)sol-gel/SPE. A thin film was formed by dripping Al(2)O(3) sol on SPE followed by electrochemical deposition of gold nanoparticles (AuNPs). The modified SPEs were characterized by scanning electron microscopy/energy dispersive X-ray analysis (SEM-EDAX), Raman spectra and voltammetric experiments. Antibodies in rabbit serum sample were allowed to react with the PfHRP-2 protein that was immobilized on the modified SPE to form antigen-antibody immune complex (PfHRP-2/anti-PfHRP-2). The bound antibodies were quantified by alkaline phosphatase (AP) enzyme labeled secondary antibodies (anti-rabbit immunoglobulins-AP conjugate). Enzymatic substrate, 1-naphthyl phosphate was converted to 1-naphthol by AP and an electroactive product was quantified using amperometry. The performances of the developed immunosensor and Dot-ELISA were tested against different dilutions of hyper immune serum (rabbit anti-PfHRP-2). Dot ELISA and the developed immunosensor (AuNPs/Al(2)O(3)sol-gel/SPE) results for the hyper immune serum containing anti-PfHRP-2 were distinctly positive when diluted upto 8 times (1 : 12800 dilution) and 11 times (1 : 102400 dilution), respectively. The developed immunosensor was applied for antibodies to PfHRP-2 in human clinical samples.


Assuntos
Óxido de Alumínio/química , Anticorpos Antiprotozoários/sangue , Técnicas Biossensoriais/métodos , Ouro/química , Nanopartículas Metálicas/química , Plasmodium falciparum/imunologia , Proteínas/imunologia , Proteínas de Protozoários/imunologia , Técnicas Eletroquímicas , Eletrodos , Ensaio de Imunoadsorção Enzimática , Géis , Humanos , Microscopia Eletrônica de Varredura
2.
J Clin Microbiol ; 46(11): 3759-65, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18799699

RESUMO

A disposable amperometric immunosensor was developed for the detection of Plasmodium falciparum histidine-rich protein 2 (PfHRP-2) in the sera of humans with P. falciparum malaria. For this purpose, disposable screen-printed electrodes (SPEs) were modified with multiwall carbon nanotubes (MWCNTs) and Au nanoparticles. The electrodes were characterized by cyclic voltammetry, scanning electron microscopy, and Raman spectroscopy. In order to study the immunosensing performances of modified electrodes, a rabbit anti-PfHRP-2 antibody (as the capturing antibody) was first immobilized on an electrode. Further, the electrode was exposed to a mouse anti-PfHRP-2 antibody from a serum sample (as the revealing antibody), followed by a rabbit anti-mouse immunoglobulin G-alkaline phosphatase conjugate. The immunosensing experiments were performed on bare SPEs, MWCNT-modified SPEs, and Au nanoparticle- and MWCNT-modified SPEs (Nano-Au/MWCNT/SPEs) for the amperometric detection of PfHRP-2 in a solution of 0.1 M diethanolamine buffer, pH 9.8, by applying a potential of 450 mV at the working electrode. Nano-Au/MWCNT/SPEs yielded the highest-level immunosensing performance among the electrodes, with a detection limit of 8 ng/ml. The analytical results of immunosensing experiments with human serum samples were compared with the results of a commercial Paracheck Pf test, as well as the results of microscopy. The specificities, sensitivities, and positive and negative predictive values of the Paracheck Pf and amperometric immunosensors were calculated by taking the microscopy results as the "gold standard." The Paracheck Pf kit exhibited a sensitivity of 79% (detecting 34 of 43 positive samples; 95% confidence interval [CI], 75 to 86%) and a specificity of 81% (correctly identifying 57 of 70 negative samples; 95% CI, 76 to 92%), whereas the developed amperometric immunosensor showed a sensitivity of 96% (detecting 41 of 43 positive samples; 95% CI, 93 to 98%) and a specificity of 94% (correctly identifying 66 of 70 negative samples; 95% CI, 92 to 99%). The developed method is more sensitive and specific than the Paracheck Pf kit.


Assuntos
Antígenos de Protozoários/sangue , Técnicas Biossensoriais/métodos , Testes Imunológicos/métodos , Malária Falciparum/diagnóstico , Proteínas de Protozoários/sangue , Soro/química , Animais , Anticorpos Antiprotozoários , Humanos , Camundongos , Valor Preditivo dos Testes , Coelhos , Sensibilidade e Especificidade
3.
Anal Sci ; 22(9): 1207-11, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16966811

RESUMO

A disposable amperometric immunosensor was studied for the rapid detection of Vibrio cholerae (V. cholerae), the causative agent of cholera, employing an indirect sandwich enzyme linked immunosorbent assay (ELISA) principle. Screen-printed electrodes (SPEs) were fabricated (by using commercial and homemade carbon inks), electrochemically characterized and the assay conditions were optimized for capturing antibodies and antigen. Whole cell lysate (WCL) of V. cholerae was used to raise antibodies in rabbits and mice. The antibodies raised against WCL of V. cholerae were found to be specific, and no cross reactivity was observed with other enteric bacteria. 1-Naphthyl phosphate was used as a substrate with the amperometric detection of its enzymatic hydrolysis product 1-naphthol at a potential of +400 mV vs. Ag/AgCl reference electrode. A comparison between the amperometric detection technique and the standard ELISA was made in terms of the total assay time, the amount of biological materials used and the sensitivity of detection. The minimum detection limit of the amperometric immunosensor for V. cholerae was found to be 10(5) cells/ml in 55 min, while ELISA detected 10(6) cells/ml in 4 h.


Assuntos
Técnicas Biossensoriais , Eletroquímica/métodos , Eletrodos , Imunoensaio/métodos , Vibrio cholerae/metabolismo , Animais , Carbono/química , Eletroquímica/instrumentação , Ensaio de Imunoadsorção Enzimática , Enzimas/análise , Hidrólise , Imunoglobulina G/análise , Camundongos , Coelhos , Sensibilidade e Especificidade , Fatores de Tempo
4.
J Biotechnol ; 188: 9-16, 2014 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-25116360

RESUMO

In this work, we fabricated a system of integrated self-assembled layer of organosilane 3-mercaptopropyltrimethoxy silane (MPTS) on the screen printed electrode (SPE) and electrochemically deposited gold nanoparticle for Salmonella typhi detection employing Vi gene as a molecular marker. Thiolated DNA probe was immobilized on a gold nanoparticle (AuNP) modified SPE for DNA hybridization assay using methylene blue as redox (electroactive) hybridization indicator, and signal was monitored by differential pulse voltammetry (DPV) method. The modified SPE was characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and atomic force microscopy (AFM) method. The DNA biosensor showed excellent performances with high sensitivity and good selectivity. The current response was linear with the target sequence concentrations ranging from 1.0 × 10(-11) to 0.5 × 10(-8)M and the detection limit was found to be 50 (± 2.1)pM. The DNA biosensor showed good discrimination ability to the one-base, two-base and three-base mismatched sequences. The fabricated genosensor could also be regenerated easily and reused for three to four times for further hybridization studies.


Assuntos
Técnicas Eletroquímicas/instrumentação , Eletrodos , Ouro/química , Nanopartículas Metálicas , Salmonella typhi/isolamento & purificação , Silanos/química , Compostos de Sulfidrila/química , Técnicas Biossensoriais , DNA Bacteriano/análise , Microscopia de Força Atômica , Hibridização de Ácido Nucleico , Salmonella typhi/genética
5.
Biosens Bioelectron ; 25(4): 832-8, 2009 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-19762223

RESUMO

A novel, highly sensitive amperometric biosensor, based on electrodeposition of gold-platinum bimetallic nanoparticles onto 3-aminopropyltriethoxy silane modified glassy carbon electrode for the detection of paraoxon ethyl, aldicarb, and sarin has been developed. The biosensor consists of acetylcholineesterase (AChE)/choline oxidase (ChOx) immobilized by cross-linking with glutaraldehyde on a modified electrode. The properties of nanoparticles modified electrodes are characterized by scanning electron microscopy (SEM), energy dispersive X-ray (EDX), cyclic voltammograms (CVs) and electrochemical impedance spectroscopy (EIS). The synergistic action of Au and Pt nanoparticles showed excellent electrocatalytic activity with low applied potential for the detection of hydrogen peroxide (H(2)O(2)). The IC(50) and inhibition rate constant (K(i)) values were determined for the inhibitors using immobilized enzymes on modified electrode and the data were compared by spectrophotometric determination of these kinetic parameters using free enzymes in solution. Paraoxon ethyl, sarin, and aldicarb could be detected up to 150-200nM, 40-50nM, and 40-60 microM respectively at 30-40% inhibition level of AChE enzyme and followed linearity in wide range concentration.


Assuntos
Acetilcolinesterase/química , Oxirredutases do Álcool/química , Técnicas Biossensoriais/instrumentação , Carbamatos/análise , Ouro/química , Neurotoxinas/análise , Organofosfatos/análise , Praguicidas/análise , Platina/química , Carbono/química , Eletroquímica/instrumentação , Eletrodos , Enzimas Imobilizadas/química , Desenho de Equipamento , Análise de Falha de Equipamento , Nanopartículas/química , Nanopartículas/ultraestrutura
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa