Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
J Cardiovasc Magn Reson ; 25(1): 48, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-37574552

RESUMO

Transcatheter cardiovascular interventions increasingly rely on advanced imaging. X-ray fluoroscopy provides excellent visualization of catheters and devices, but poor visualization of anatomy. In contrast, magnetic resonance imaging (MRI) provides excellent visualization of anatomy and can generate real-time imaging with frame rates similar to X-ray fluoroscopy. Realization of MRI as a primary imaging modality for cardiovascular interventions has been slow, largely because existing guidewires, catheters and other devices create imaging artifacts and can heat dangerously. Nonetheless, numerous clinical centers have started interventional cardiovascular magnetic resonance (iCMR) programs for invasive hemodynamic studies or electrophysiology procedures to leverage the clear advantages of MRI tissue characterization, to quantify cardiac chamber function and flow, and to avoid ionizing radiation exposure. Clinical implementation of more complex cardiovascular interventions has been challenging because catheters and other tools require re-engineering for safety and conspicuity in the iCMR environment. However, recent innovations in scanner and interventional device technology, in particular availability of high performance low-field MRI scanners could be the inflection point, enabling a new generation of iCMR procedures. In this review we review these technical considerations, summarize contemporary clinical iCMR experience, and consider potential future applications.


Assuntos
Cateterismo Cardíaco , Imagem por Ressonância Magnética Intervencionista , Humanos , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
2.
Curr Cardiol Rep ; 24(4): 419-429, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35107702

RESUMO

PURPOSE OF REVIEW: Cardiac magnetic resonance imaging provides radiation-free, 3-dimensional soft tissue visualization with adjunct hemodynamic data, making it a promising candidate for image-guided transcatheter interventions. This review focuses on the benefits and background of real-time magnetic resonance imaging (MRI)-guided cardiac catheterization, guidance on starting a clinical program, and recent research developments. RECENT FINDINGS: Interventional cardiac magnetic resonance (iCMR) has an established track record with the first entirely MRI-guided cardiac catheterization for congenital heart disease reported nearly 20 years ago. Since then, many centers have embarked upon clinical iCMR programs primarily performing diagnostic MRI-guided cardiac catheterization. There have also been limited reports of successful real-time MRI-guided transcatheter interventions. Growing experience in performing cardiac catheterization in the magnetic resonance environment has facilitated practical workflows appropriate for efficiency-focused cardiac catheterization laboratories. Most exciting developments in imaging technology, MRI-compatible equipment and MRI-guided novel transcatheter interventions have been limited to preclinical research. Many of these research developments are ready for clinical translation. With increasing iCMR clinical experience and translation of preclinical research innovations, the time to make the leap to radiation-free procedures is now.


Assuntos
Cardiopatias Congênitas , Imagem por Ressonância Magnética Intervencionista , Cateterismo Cardíaco/métodos , Coração , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/terapia , Humanos , Imageamento por Ressonância Magnética , Imagem por Ressonância Magnética Intervencionista/métodos
3.
Pediatr Cardiol ; 43(8): 1716-1722, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35430709

RESUMO

We report our experience with transcatheter patent ductus arteriosus (PDA) closure in premature infants and compare patients grouped by the device used for closure: the Microvascular Plug, "MVP" (Medtronic, Minneapolis, MN); Micro Plug Set, "Micro Plug" (KA Medical, Minneapolis, MN); and Amplatzer Piccolo Occluder, "Piccolo" (Abbot, Santa Clara, CA). We also report trends in device selection over time. Studies examining outcomes according to device selection for PDA closure in premature infants are lacking. We performed a retrospective review of all percutaneous PDA closures in premature infants at a single center (June 2018-May 2021). Patients were grouped by initial device selected for PDA closure (intention to treat). Institutional Review Board approval was obtained. 58 premature infants [MVP (n = 25), Micro Plug (n = 25), and Piccolo (n = 8)] underwent successful transcatheter PDA closure (mean gestational age 27 weeks 2 days; mean weight at procedure 1.4 kg; mean age at procedure 28 days). Pre-procedural demographics, procedural data, and follow-up data were similar between groups. There were no significant procedural adverse events. Three devices (2 MVP, 0 Micro Plug, 1 Piccolo p = 0.27) embolized after the procedure. One other device was removed for concern for aortic obstruction. Device selection evolved with a clear trend toward the Micro Plug device over time. Demographic, procedural, and follow-up data were similar between the MVP, Micro Plug, and Piccolo groups. The Micro Plug did not require exchange for suboptimal fitting or embolize and became our preferred device in most cases.


Assuntos
Permeabilidade do Canal Arterial , Doenças do Prematuro , Dispositivo para Oclusão Septal , Recém-Nascido , Lactente , Humanos , Permeabilidade do Canal Arterial/cirurgia , Cateterismo Cardíaco/métodos , Resultado do Tratamento , Recém-Nascido Prematuro , Estudos Retrospectivos
4.
Pediatr Cardiol ; 43(4): 894-902, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34894280

RESUMO

Guidelines for management of Melody transcatheter pulmonary valve (TPV) infective endocarditis (IE) are lacking. We aimed to identify factors associated with surgical valve removal versus antimicrobial therapy in Melody TPV IE. Multicenter retrospective analysis of all patients receiving Melody TPV from 10/2010 to 3/2019 was performed to identify cases of IE. Surgical explants versus non-surgical cases were compared. Of the 663 Melody TPV implants, there were 66 cases of IE in 59 patients (59/663, 8.8%). 39/66 (59%) were treated with IV antimicrobials and 27/66(41%) underwent valve explantation. 26/59 patients (44%) were treated medically without explantation or recurrence with average follow-up time of 3.5 years (range:1-9). 32% of Streptococcus cases, 53% of MSSA, and all MRSA cases were explanted. 2 of the 4 deaths had MSSA. CART analysis demonstrated two important parameters associated with explantation: a peak echo gradient ≥ 47 mmHg at IE diagnosis(OR 10.6, p < 0.001) and a peak echo gradient increase of > 24 mmHg compared to baseline (OR 6.7, p = 0.01). Rates of explantation varied by institution (27 to 64%). In our multicenter experience, 44% of patients with Melody IE were successfully medically treated without valve explantation or recurrence. The degree of valve stenosis at time of IE diagnosis was strongly associated with explantation. Rates of explantation varied significantly among the institutions.


Assuntos
Endocardite Bacteriana , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar , Valva Pulmonar , Cateterismo Cardíaco/efeitos adversos , Endocardite/etiologia , Endocardite/cirurgia , Endocardite Bacteriana/tratamento farmacológico , Endocardite Bacteriana/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Desenho de Prótese , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
5.
Cardiol Young ; 31(10): 1613-1618, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33641693

RESUMO

INTRODUCTION: Many newborns with pulmonary atresia/intact ventricular septum require intervention to establish pulmonary flow and sufficient cardiac output. The resulting haemodynamic changes are not well characterised and may have unintended consequences. METHODS: This is a 30-year (1988-2018) retrospective study of patients with pulmonary atresia intact ventricular septum. RESULTS: Eighty-nine patients were included, and median follow-up was 8 years. Fifty-five per cent had coronary sinusoids and 27% had right ventricular-dependent coronary circulation. Most patients were managed with surgical aortopulmonary or modified Blalock-Taussig shunt (73%), and 12 patients underwent balloon atrial septostomy before surgical intervention. The remaining patients (27%) underwent only transcatheter interventions; 7 required an atrial septostomy and 17 required ductal stentings. All-cause mortality was 10%, most deaths (89%) occurred before 18 months of age. Of these early deaths, 87% required a balloon atrial septostomy and 85% had right ventricular-dependent coronary sinusoids. Eighteen-month mortality was significantly higher for patients who required a balloon atrial septostomy compared to those who did not (36% versus 1.4% p < 0.0001). DISCUSSION: Patients with pulmonary atresia/intact ventricular septum who require balloon atrial septostomy in the newborn period have significantly higher 18-month mortality. Quantifying the mortality difference may help guide prognostication and expectation setting. Infants who had septostomy and a surgical shunt in the newborn period fared better than those who only underwent septostomy (even when accompanied by ductal stenting). For infants with right ventricular-dependent circulation, atrial septostomy should only be performed on an urgent or emergent basis and these patients should be considered for early surgical intervention and neonatal transplant.


Assuntos
Cardiopatias Congênitas , Atresia Pulmonar , Septo Interventricular , Cardiopatias Congênitas/cirurgia , Humanos , Lactente , Recém-Nascido , Atresia Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/cirurgia
6.
Catheter Cardiovasc Interv ; 96(7): 1439-1444, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32979038

RESUMO

OBJECTIVES: We intend to describe early experience using a new, commercially available Micro Plug Set for preterm neonate and infant transcatheter patent ductus arteriosus (PDA) occlusion. BACKGROUND: Transcatheter PDA occlusion in premature neonates and small infants is safe and effective. The procedure is early in its evolution. METHODS: Procedural and short-term outcomes of preterm neonates and infants undergoing transcatheter PDA occlusion with a new, commercially available device were reviewed. RESULTS: Eight preterm neonates and infants born at median 27 weeks gestation (23-36 weeks) underwent transcatheter PDA device closure with the Micro Plug Set. The device is short (2.5 mm) with a range of diameters (3, 4, 5, 6 mm) and delivered through a microcatheter. Procedures were performed at median 41 days of age (12-88 days) and at 1690 g (760-3,310 g). Transvenous PDA device occlusion was performed with fluoroscopic and echocardiography guidance. All procedures were successful with complete PDA occlusion. There were no procedural or short-term adverse events. CONCLUSIONS: Preterm neonate and infant transcatheter PDA device closure with a new, commercially available short and microcatheter delivered device (Micro Plug Set) was safe and effective in a small, early series of patients.


Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Peso ao Nascer , Cateterismo Cardíaco/efeitos adversos , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Desenho de Equipamento , Idade Gestacional , Humanos , Recém-Nascido de Baixo Peso , Recém-Nascido , Recém-Nascido Prematuro , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 96(7): 1434-1438, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32926536

RESUMO

BACKGROUND: Patent ductus arteriosus (PDA) stenting is evolving as an alternative to surgical aorto-pulmonary shunts for infants with ductal-dependent pulmonary blood flow. Given anatomical proximity, the PDA can compress the ipsilateral bronchus. We report a case series of four patients with bronchial compression by a tortuous PDA who underwent PDA stenting. METHODS: Our four patients received PDA stents for ductal-dependent pulmonary blood flow despite preprocedure imaging evidence of bronchial compression. We reviewed the cross-sectional chest imaging to assess the degree of bronchial compression and the variables that affect it, namely PDA size, PDA tortuosity, and the anatomical relationship between the compressed bronchus and the PDA. RESULTS: Three out of the four patients had postprocedure imaging, and all showed relief of the previously seen bronchial compression. Post-PDA stenting patients had a smaller and straight PDA with significant lateralization away from the compressed bronchus. None of the four patients developed symptoms of bronchial compression poststenting. CONCLUSIONS: Our study suggests that pre-existing bronchial compression does not preclude PDA stenting. Stent placement in an engorged and tortuous PDA led to significant improvement in pre-existing bronchial compression. Improvement may be attributed to PDA shrinkage, straightening, and lateralization. Further studies are needed to confirm our findings.


Assuntos
Broncopatias/terapia , Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Circulação Pulmonar , Stents , Broncopatias/diagnóstico por imagem , Broncopatias/etiologia , Broncopatias/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Constrição Patológica , Permeabilidade do Canal Arterial/complicações , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Humanos , Lactente , Recém-Nascido , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
8.
Pediatr Cardiol ; 41(3): 503-513, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32198594

RESUMO

In recent years, interventional cardiac magnetic resonance imaging (iCMR) has evolved from attractive theory to clinical routine at several centers. Real-time cardiac magnetic resonance imaging (CMR fluoroscopy) adds value by combining soft-tissue visualization, concurrent hemodynamic measurement, and freedom from radiation. Clinical iCMR applications are expanding because of advances in catheter devices and imaging. In the near future, iCMR promises novel procedures otherwise unsafe under standalone X-Ray guidance.


Assuntos
Cateterismo Cardíaco/métodos , Imagem por Ressonância Magnética Intervencionista/instrumentação , Fluoroscopia/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos
9.
Catheter Cardiovasc Interv ; 94(3): 399-408, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31062506

RESUMO

OBJECTIVES: To determine whether X-ray fused with MRI (XFM) is beneficial for select transcatheter congenital heart disease interventions. BACKGROUND: Complex transcatheter interventions often require three-dimensional (3D) soft tissue imaging guidance. Fusion imaging with live X-ray fluoroscopy can potentially improve and simplify procedures. METHODS: Patients referred for select congenital heart disease interventions were prospectively enrolled. Cardiac MRI data was overlaid on live fluoroscopy for procedural guidance. Likert scale operator assessments of value were recorded. Fluoroscopy time, radiation exposure, contrast dose, and procedure time were compared to matched cases from our institutional experience. RESULTS: Forty-six patients were enrolled. Pre-catheterization, same day cardiac MRI findings indicated intervention should be deferred in nine patients. XFM-guided cardiac catheterization was performed in 37 (median age 8.7 years [0.5-63 years]; median weight 28 kg [5.6-110 kg]) with the following prespecified indications: pulmonary artery (PA) stenosis (n = 13), aortic coarctation (n = 12), conduit stenosis/insufficiency (n = 9), and ventricular septal defect (n = 3). Diagnostic catheterization showed intervention was not indicated in 12 additional cases. XFM-guided intervention was performed in the remaining 25. Fluoroscopy time was shorter for XFM-guided intervention cases compared to matched controls. There was no significant difference in radiation dose area product, contrast volume, or procedure time. Operator Likert scores indicated XFM provided useful soft tissue guidance in all cases and was never misleading. CONCLUSIONS: XFM provides operators with meaningful three-dimensional soft tissue data and reduces fluoroscopy time in select congenital heart disease interventions.


Assuntos
Cateterismo Cardíaco , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/terapia , Imageamento por Ressonância Magnética , Radiografia Intervencionista , Adolescente , Adulto , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Tomada de Decisão Clínica , Meios de Contraste/administração & dosagem , Feminino , Fluoroscopia , Humanos , Lactente , Imageamento por Ressonância Magnética/efeitos adversos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Seleção de Pacientes , Valor Preditivo dos Testes , Estudos Prospectivos , Doses de Radiação , Exposição à Radiação , Radiografia Intervencionista/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
10.
Cardiol Young ; 29(2): 93-99, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30587259

RESUMO

Stenosis, or narrowing, of the branches of the pulmonary artery is a type of CHD that, if left untreated, may lead to significant complications. Ideally, interventions to treat stenosis occur before significant complications or long-term sequelae take place, often within the first 2 years of life. Treatment depends on specifics of the condition, the presence of other malformations, and age of the child. Research and recent innovation to address these shortcomings have provided physicians with safer and more effective methods of treatment. This has further continued to push the ceiling of pulmonary arterial stenosis treatment available for patients. Despite continuous advancement in angioplasty - such as conventional and cutting balloon - and stenting, each treatment method is not without its unique limitations. New technological developments such as bioresorbable stents can accommodate patient growth and pulmonary artery stenosis treatment. As more than a decade has passed since the review by Bergersen and Lock, this article aims to provide a contemporary summary and investigation into the effectiveness of various therapeutic tools currently available, such as bare metal stents and potential innovations including bioresorbable stents.


Assuntos
Cardiopatias Congênitas/cirurgia , Estenose de Artéria Pulmonar/congênito , Estenose de Artéria Pulmonar/cirurgia , Angioplastia com Balão , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Stents
11.
J Cardiovasc Electrophysiol ; 28(5): 517-522, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28245348

RESUMO

BACKGROUND: Arrhythmia ablation with current techniques is not universally successful. Inadequate ablation lesion formation may be responsible for some arrhythmia recurrences. Periprocedural visualization of ablation lesions may identify inadequate lesions and gaps to guide further ablation and reduce risk of arrhythmia recurrence. METHODS: This feasibility study assessed acute postprocedure ablation lesions by MRI, and correlated these findings with clinical outcomes. Ten pediatric patients who underwent ventricular tachycardia ablation were transferred immediately postablation to a 1.5T MRI scanner and late gadolinium enhancement (LGE) imaging was performed to characterize ablation lesions. Immediate and mid-term arrhythmia recurrences were assessed. RESULTS: Patient characteristics include median age 14 years (1-18 years), median weight 52 kg (11-81 kg), normal cardiac anatomy (n = 6), d-transposition of great arteries post arterial switch repair (n = 2), anomalous coronary artery origin post repair (n = 1), and cardiac rhabdomyoma (n = 1). All patients underwent radiofrequency catheter ablation of ventricular arrhythmia with acute procedural success. LGE was identified at the reported ablation site in 9/10 patients, all arrhythmia-free at median 7 months follow-up. LGE was not visible in 1 patient who had recurrence of frequent premature ventricular contractions within 2 hours, confirmed on Holter at 1 and 21 months post procedure. CONCLUSIONS: Ventricular ablation lesion visibility by MRI in the acute post procedure setting is feasible. Lesions identifiable with MRI may correlate with clinical outcomes. Acute MRI identification of gaps or inadequate lesions may provide the unique temporal opportunity for additional ablation therapy to decrease arrhythmia recurrence.


Assuntos
Ablação por Cateter , Ventrículos do Coração/cirurgia , Imageamento por Ressonância Magnética , Taquicardia Ventricular/cirurgia , Adolescente , Fatores Etários , Ablação por Cateter/efeitos adversos , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Recidiva , Fatores de Risco , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
12.
J Cardiovasc Magn Reson ; 19(1): 54, 2017 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-28750642

RESUMO

BACKGROUND: Quantification of cardiac output and pulmonary vascular resistance (PVR) are critical components of invasive hemodynamic assessment, and can be measured concurrently with pressures using phase contrast CMR flow during real-time CMR guided cardiac catheterization. METHODS: One hundred two consecutive patients underwent CMR fluoroscopy guided right heart catheterization (RHC) with simultaneous measurement of pressure, cardiac output and pulmonary vascular resistance using CMR flow and the Fick principle for comparison. Procedural success, catheterization time and adverse events were prospectively collected. RESULTS: RHC was successfully completed in 97/102 (95.1%) patients without complication. Catheterization time was 20 ± 11 min. In patients with and without pulmonary hypertension, baseline mean pulmonary artery pressure was 39 ± 12 mmHg vs. 18 ± 4 mmHg (p < 0.001), right ventricular (RV) end diastolic volume was 104 ± 64 vs. 74 ± 24 (p = 0.02), and RV end-systolic volume was 49 ± 30 vs. 31 ± 13 (p = 0.004) respectively. 103 paired cardiac output and 99 paired PVR calculations across multiple conditions were analyzed. At baseline, the bias between cardiac output by CMR and Fick was 5.9% with limits of agreement -38.3% and 50.2% with r = 0.81 (p < 0.001). The bias between PVR by CMR and Fick was -0.02 WU.m2 with limits of agreement -2.6 and 2.5 WU.m2 with r = 0.98 (p < 0.001). Correlation coefficients were lower and limits of agreement wider during physiological provocation with inhaled 100% oxygen and 40 ppm nitric oxide. CONCLUSIONS: CMR fluoroscopy guided cardiac catheterization is safe, with acceptable procedure times and high procedural success rate. Cardiac output and PVR measurements using CMR flow correlated well with the Fick at baseline and are likely more accurate during physiological provocation with supplemental high-concentration inhaled oxygen. TRIAL REGISTRATION: Clinicaltrials.gov NCT01287026 , registered January 25, 2011.


Assuntos
Cateterismo Cardíaco , Débito Cardíaco , Hipertensão Pulmonar/diagnóstico por imagem , Imagem por Ressonância Magnética Intervencionista , Artéria Pulmonar/fisiopatologia , Resistência Vascular , Administração por Inalação , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Fluoroscopia , Humanos , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Óxido Nítrico/administração & dosagem , Oxigênio/administração & dosagem , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo
13.
J Cardiovasc Magn Reson ; 19(1): 65, 2017 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-28874164

RESUMO

BACKGROUND: Children with heart disease may require repeated X-Ray cardiac catheterization procedures, are more radiosensitive, and more likely to survive to experience oncologic risks of medical radiation. Cardiovascular magnetic resonance (CMR) is radiation-free and offers information about structure, function, and perfusion but not hemodynamics. We intend to perform complete radiation-free diagnostic right heart catheterization entirely using CMR fluoroscopy guidance in an unselected cohort of pediatric patients; we report the feasibility and safety. METHODS: We performed 50 CMR fluoroscopy guided comprehensive transfemoral right heart catheterizations in 39 pediatric (12.7 ± 4.7 years) subjects referred for clinically indicated cardiac catheterization. CMR guided catheterizations were assessed by completion (success/failure), procedure time, and safety events (catheterization, anesthesia). Pre and post CMR body temperature was recorded. Concurrent invasive hemodynamic and diagnostic CMR data were collected. RESULTS: During a twenty-two month period (3/2015 - 12/2016), enrolled subjects had the following clinical indications: post-heart transplant 33%, shunt 28%, pulmonary hypertension 18%, cardiomyopathy 15%, valvular heart disease 3%, and other 3%. Radiation-free CMR guided right heart catheterization attempts were all successful using passive catheters. In two subjects with septal defects, right and left heart catheterization were performed. There were no complications. One subject had six such procedures. Most subjects (51%) had undergone multiple (5.5 ± 5) previous X-Ray cardiac catheterizations. Retained thoracic surgical or transcatheter implants (36%) did not preclude successful CMR fluoroscopy heart catheterization. During the procedure, two subjects were receiving vasopressor infusions at baseline because of poor cardiac function, and in ten procedures, multiple hemodynamic conditions were tested. CONCLUSIONS: Comprehensive CMR fluoroscopy guided right heart catheterization was feasible and safe in this small cohort of pediatric subjects. This includes subjects with previous metallic implants, those requiring continuous vasopressor medication infusions, and those requiring pharmacologic provocation. Children requiring multiple, serial X-Ray cardiac catheterizations may benefit most from radiation sparing. This is a step toward wholly CMR guided diagnostic (right and left heart) cardiac catheterization and future CMR guided cardiac intervention. TRIAL REGISTRATION: ClinicalTrials.gov NCT02739087 registered February 17, 2016.


Assuntos
Cateterismo Cardíaco/métodos , Cardiopatias/diagnóstico , Imagem por Ressonância Magnética Intervencionista , Exposição à Radiação/prevenção & controle , Adolescente , Fatores Etários , Criança , Estudos de Viabilidade , Feminino , Cardiopatias/fisiopatologia , Hemodinâmica , Humanos , Masculino , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos , Fatores de Tempo
14.
Catheter Cardiovasc Interv ; 86(2): E111-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25315516

RESUMO

OBJECTIVES: We test the safety of transatrial pericardial access using small catheters, infusion of carbon dioxide (CO2 ) or iodinated contrast to facilitate sub-xiphoid access, and catheter withdrawal under full anticoagulation. BACKGROUND: Sub-xiphoid pericardial access is required for electrophysiological and structural heart interventions. If present, an effusion protects the heart from needle injury by separating the myocardium from the pericardium. However, if the pericardium is 'dry' then there is a significant risk of right ventricle or coronary artery laceration caused by the heart beating against the needle tip. Intentional right atrial exit is an alternative pericardial access route, through which contrast media could be infused to separate pericardial layers. METHODS: Transatrial pericardial access was obtained in a total of 30 Yorkshire swine using 4Fr or 2.8Fr catheters. In 16 animals, transatrial catheters were withdrawn under anticoagulation and MRI was performed to monitor for pericardial hemorrhage. In 14 animals, iodinated contrast or CO2 was infused before sub-xiphoid access was obtained. RESULTS: Small effusions (mean 18.5 ml) were observed after 4Fr (1.3 mm outer-diameter) but not after 2.8Fr (0.9 mm outer-diameter) transatrial catheter withdrawal despite full anticoagulation (mean activated clotting time 383 sec), with no hemodynamic compromise. Pericardial CO2 resorbed spontaneously within 15 min. CONCLUSIONS: Intentional transatrial exit into the pericardium using small catheters is safe and permits infusion of CO2 or iodinated contrast to separate pericardial layers and facilitate sub-xiphoid access. This reduces the risk of right ventricular or coronary artery laceration. 2.8Fr transatrial catheter withdrawal does not cause any pericardial hemorrhage, even under full anticoagulation.


Assuntos
Pontos de Referência Anatômicos , Dióxido de Carbono/administração & dosagem , Cateterismo Cardíaco/métodos , Meios de Contraste/administração & dosagem , Iopamidol/administração & dosagem , Pneumorradiografia/métodos , Processo Xifoide/diagnóstico por imagem , Animais , Anticoagulantes/administração & dosagem , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Modelos Animais de Doenças , Desenho de Equipamento , Átrios do Coração/diagnóstico por imagem , Hemorragia/etiologia , Infusões Parenterais , Imageamento por Ressonância Magnética , Miniaturização , Derrame Pericárdico/etiologia , Pneumorradiografia/efeitos adversos , Pneumorradiografia/instrumentação , Punções , Fatores de Risco , Suínos
15.
J Cardiovasc Magn Reson ; 17: 105, 2015 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-26620420

RESUMO

BACKGROUND: Conventional guidewires are not suitable for use during cardiovascular magnetic resonance (CMR) catheterization. They employ metallic shafts for mechanical performance, but which are conductors subject to radiofrequency (RF) induced heating. To date, non-metallic CMR guidewire designs have provided inadequate mechanical support, trackability, and torquability. We propose a metallic guidewire for CMR that is by design intrinsically safe and that retains mechanical performance of commercial guidewires. METHODS: The NHLBI passive guidewire is a 0.035" CMR-safe, segmented-core nitinol device constructed using short nitinol rod segments. The electrical length of each segment is less than one-quarter wavelength at 1.5 Tesla, which eliminates standing wave formation, and which therefore eliminates RF heating along the shaft. Each of the electrically insulated segments is connected with nitinol tubes for stiffness matching to assure uniform flexion. Iron oxide markers on the distal shaft impart conspicuity. Mechanical integrity was tested according to International Organization for Standardization (ISO) standards. CMR RF heating safety was tested in vitro in a phantom according to American Society for Testing and Materials (ASTM) F-2182 standard, and in vivo in seven swine. Results were compared with a high-performance commercial nitinol guidewire. RESULTS: The NHLBI passive guidewire exhibited similar mechanical behavior to the commercial comparator. RF heating was reduced from 13 °C in the commercial guidewire to 1.2 °C in the NHLBI passive guidewire in vitro, using a flip angle of 75°. The maximum temperature increase was 1.1 ± 0.3 °C in vivo, using a flip angle of 45°. The guidewire was conspicuous during left heart catheterization in swine. CONCLUSIONS: We describe a simple and intrinsically safe design of a metallic guidewire for CMR cardiovascular catheterization. The guidewire exhibits negligible heating at high flip angles in conformance with regulatory guidelines, yet mechanically resembles a high-performance commercial guidewire. Iron oxide markers along the length of the guidewire impart passive visibility during real-time CMR. Clinical translation is imminent.


Assuntos
Ligas/química , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Imagem por Ressonância Magnética Intervencionista/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Animais , Condutividade Elétrica , Desenho de Equipamento , Falha de Equipamento , Compostos Férricos/química , Marcadores Fiduciais , Temperatura Alta , Teste de Materiais , Modelos Animais , Imagens de Fantasmas , Suínos
16.
Pediatr Radiol ; 45(10): 1455-64, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26040508

RESUMO

BACKGROUND: Cardiac magnetic resonance (MR) imaging is a valuable tool in congenital heart disease; however patients frequently have metal devices in the chest from the treatment of their disease that complicate imaging. Methods are needed to improve imaging around metal implants near the heart. Basic sequence parameter manipulations have the potential to minimize artifact while limiting effects on image resolution and quality. OBJECTIVE: Our objective was to design cine and static cardiac imaging sequences to minimize metal artifact while maintaining image quality. MATERIALS AND METHODS: Using systematic variation of standard imaging parameters on a fluid-filled phantom containing commonly used metal cardiac devices, we developed optimized sequences for steady-state free precession (SSFP), gradient recalled echo (GRE) cine imaging, and turbo spin-echo (TSE) black-blood imaging. We imaged 17 consecutive patients undergoing routine cardiac MR with 25 metal implants of various origins using both standard and optimized imaging protocols for a given slice position. We rated images for quality and metal artifact size by measuring metal artifact in two orthogonal planes within the image. RESULTS: All metal artifacts were reduced with optimized imaging. The average metal artifact reduction for the optimized SSFP cine was 1.5+/-1.8 mm, and for the optimized GRE cine the reduction was 4.6+/-4.5 mm (P < 0.05). Quality ratings favored the optimized GRE cine. Similarly, the average metal artifact reduction for the optimized TSE images was 1.6+/-1.7 mm (P < 0.05), and quality ratings favored the optimized TSE imaging. CONCLUSION: Imaging sequences tailored to minimize metal artifact are easily created by modifying basic sequence parameters, and images are superior to standard imaging sequences in both quality and artifact size. Specifically, for optimized cine imaging a GRE sequence should be used with settings that favor short echo time, i.e. flow compensation off, weak asymmetrical echo and a relatively high receiver bandwidth. For static black-blood imaging, a TSE sequence should be used with fat saturation turned off and high receiver bandwidth.


Assuntos
Aorta Torácica/patologia , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Imageamento por Ressonância Magnética , Próteses e Implantes , Adolescente , Adulto , Artefatos , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Metais , Miocárdio/patologia , Imagens de Fantasmas , Reprodutibilidade dos Testes , Adulto Jovem
17.
Pediatr Nephrol ; 29(6): 1067-74, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24445432

RESUMO

BACKGROUND: Renal artery stenosis (RAS) accounts for 10 % of cases of systemic hypertension in children. Initial management involves anti-hypertensive therapy. Percutaneous interventions are documented for the treatment of RAS in the adult population. In children, case reports suggest benefit. METHODS: This is a retrospective analysis of consecutive patients referred for catheterization for RAS between 2002 and 2010 at a single institution. Recorded variables included: age, weight, systemic blood pressure, minimal luminal diameter, interventional devices, antihypertensive medications, contrast volume, and complications. RESULTS: Twelve patients (median age 8.2, IQR 6-12.4 years); median weight 42.8 kg, IQR: 25-47.4 kg) were referred for renal artery catheterization and underwent percutaneous intervention. Overall, minimal luminal diameter (MLD) increased by 1.2 ± 0.9 mm for all patients (p < 0.05) and by 1.3 ± 0.9 mm for post-renal transplant patients (p < 0.05). Only stent angioplasty patients demonstrated significant improved blood pressure (p < 0.05). One patient had stent thrombosis requiring re-intervention with repeat balloon angioplasty. CONCLUSIONS: This retrospective analysis suggests that percutaneous intervention might play a role in the management of RAS, with an improvement in MLD in children with RAS. Transcatheter intervention is technically feasible with low morbidity. A prospective, longitudinal study is warranted to compare standard medical therapy with percutaneous interventions.


Assuntos
Angioplastia/métodos , Obstrução da Artéria Renal/terapia , Angioplastia com Balão , Criança , Feminino , Humanos , Hipertensão/etiologia , Lactente , Masculino , Obstrução da Artéria Renal/complicações , Estudos Retrospectivos , Stents , Adulto Jovem
18.
Eur Heart J ; 34(5): 380-9, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22855740

RESUMO

AIMS: Real-time MRI creates images with superb tissue contrast that may enable radiation-free catheterization. Simple procedures are the first step towards novel interventional procedures. We aim to perform comprehensive transfemoral diagnostic right heart catheterization in an unselected cohort of patients entirely using MRI guidance. METHODS AND RESULTS: We performed X-ray and MRI-guided transfemoral right heart catheterization in consecutive patients undergoing clinical cardiac catheterization. We sampled both cavae and both pulmonary arteries. We compared success rate, time to perform key steps, and catheter visibility among X-ray and MRI procedures using air-filled or gadolinium-filled balloon-tipped catheters. Sixteen subjects (four with shunt, nine with coronary artery disease, three with other) underwent paired X-ray and MRI catheterization. Complete guidewire-free catheterization was possible in 15 of 16 under both. MRI using gadolinium-filled balloons was at least as successful as X-ray in all procedure steps, more successful than MRI using air-filled balloons, and better than both in entering the left pulmonary artery. Total catheterization time and individual procedure steps required approximately the same amount of time irrespective of image guidance modality. Catheter conspicuity was best under X-ray and next-best using gadolinium-filled MRI balloons. CONCLUSION: In this early experience, comprehensive transfemoral right heart catheterization appears feasible using only MRI for imaging guidance. Gadolinium-filled balloon catheters were more conspicuous than air-filled ones. Further workflow and device enhancement are necessary for clinical adoption.


Assuntos
Cateterismo Cardíaco/métodos , Cardiopatias/diagnóstico , Meios de Contraste , Estudos de Viabilidade , Feminino , Gadolínio , Humanos , Angiografia por Ressonância Magnética/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Radiografia Intervencionista/métodos
19.
J Cardiovasc Magn Reson ; 15: 61, 2013 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-23870697

RESUMO

BACKGROUND: Needle access or drainage of pericardial effusion, especially when small, entails risk of bystander tissue injury or operator uncertainty about proposed trajectories. Cardiovascular magnetic resonance (CMR) might allow enhanced imaging guidance. METHODS AND RESULTS: We used real-time CMR to guide subxiphoid pericardial access in naïve swine using commercial 18G titanium puncture needles, which were exchanged for pericardial catheters. To test the value of CMR needle pericardiocentesis, we also created intentional pericardial effusions of a range of volumes, via a separate transvenous-transatrial catheter. We performed these procedures in 12 animals. CONCLUSIONS: CMR guided pericardiocentesis is attractive because the large field of view and soft tissue imaging depict global anatomic context in arbitrary planes, and allow the operator to plan trajectories that limit inadvertent bystander tissue injury. More important, CMR provides continuous visualization of the needle and target throughout the procedure. Using even passive needle devices, CMR enabled rapid pericardial needle access and drainage. We believe this experience supports clinical testing of real-time CMR guided needle access or drainage of the pericardial space. We suspect this would be especially helpful in "difficult" pericardial access, for example, in distorted thoracic anatomy or loculated effusion.


Assuntos
Catéteres , Imagem por Ressonância Magnética Intervencionista , Derrame Pericárdico/terapia , Pericardiocentese/instrumentação , Pericardiocentese/métodos , Animais , Modelos Animais de Doenças , Desenho de Equipamento , Hemodinâmica , Agulhas , Derrame Pericárdico/fisiopatologia , Pericardiocentese/efeitos adversos , Punções , Suínos , Fatores de Tempo
20.
J Cardiovasc Magn Reson ; 15: 10, 2013 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-23331459

RESUMO

BACKGROUND: We aim to deliver large appliances into the left ventricle through the right ventricle and across the interventricular septum. This transthoracic access route exploits immediate recoil of the septum, and lower transmyocardial pressure gradient across the right versus left ventricular free wall. The route may enhance safety and allow subxiphoid rather than intercostal traversal. METHODS: The entire procedure was performed under real-time CMR guidance. An "active" CMR needle crossed the chest, right ventricular free wall, and then the interventricular septum to deliver a guidewire then used to deliver an 18Fr introducer. Afterwards, the right ventricular free wall was closed with a nitinol occluder. Immediate closure and late healing of the unrepaired septum and free wall were assessed by oximetry, angiography, CMR, and necropsy up to four weeks afterwards. RESULTS: The procedure was successful in 9 of 11 pigs. One failed because of refractory ventricular fibrillation upon needle entry, and the other because of inadequate guidewire support. In all ten attempts, the right ventricular free wall was closed without hemopericardium. There was neither immediate nor late shunt on oximetry, X-ray angiography, or CMR. The interventricular septal tract fibrosed completely. Transventricular trajectories planned on human CT scans suggest comparable intracavitary working space and less acute entry angles than a conventional atrial transseptal approach. CONCLUSION: Large closed-chest access ports can be introduced across the right ventricular free wall and interventricular septum into the left ventricle. The septum recoils immediately and heals completely without repair. A nitinol occluder immediately seals the right ventricular wall. The entry angle is more favorable to introduce, for example, prosthetic mitral valves than a conventional atrial transseptal approach.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Ventrículos do Coração/patologia , Imagem por Ressonância Magnética Intervencionista , Dispositivo para Oclusão Septal , Septo Interventricular/patologia , Idoso , Ligas , Animais , Cateteres Cardíacos , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/terapia , Estudos de Viabilidade , Feminino , Fibrose , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Animais , Desenho de Prótese , Punções , Suínos , Fatores de Tempo , Tomografia Computadorizada por Raios X , Função Ventricular , Septo Interventricular/diagnóstico por imagem , Septo Interventricular/fisiopatologia , Cicatrização
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa