Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Vasc Med ; 21(4): 317-24, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26994006

RESUMO

The object of this study was to utilize a novel feed-forward active contour (FFAC) algorithm to find a reproducible technique for analysis of brachial artery reactivity. Flow-mediated dilation (FMD) is an important marker of vascular endothelial function but has not been adopted for widespread clinical use given its technical limitations, including inter-observer variability and differences in technique across clinical sites. We developed a novel FFAC algorithm with the goal of validating a more reliable standard. Forty-six healthy volunteers underwent FMD measurement according to the standard technique. Ultrasound videos lasting 5-10 seconds each were obtained pre-cuff inflation and at minutes 1 through 5 post-cuff deflation in longitudinal and transverse views. Automated segmentation using the FFAC algorithm with initial boundary definition from three different observers was used to analyze the images to measure diameter/cross-sectional area over the cardiac cycle. The %FMD was calculated for average, minimum, and maximum diameters/areas. Using the FFAC algorithm, the population-specific coefficient of variation (CV) at end-diastole was 3.24% for transverse compared to 9.96% for longitudinal measurements; the subject-specific CV was 15.03% compared to 57.41%, respectively. For longitudinal measurements made via the conventional method, the population-specific CV was 4.77% and subject-specific CV was 117.79%. The intraclass correlation coefficient (ICC) for transverse measurements was 0.97 (95% CI: 0.95-0.98) compared to 0.90 (95% CI: 0.84-0.94) for longitudinal measurements with FFAC and 0.72 (95% CI: 0.51-0.84) for conventional measurements. In conclusion, transverse views using the novel FFAC method provide less inter-observer variability than traditional longitudinal views. Improved reproducibility may allow adoption of FMD testing in a clinical setting. The FFAC algorithm is a robust technique that should be evaluated further for its ability to replace the more limited conventional technique for measurement of FMD.


Assuntos
Algoritmos , Artéria Braquial/diagnóstico por imagem , Doenças Cardiovasculares/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Ultrassonografia/métodos , Vasodilatação , Adolescente , Adulto , Idoso , Artéria Braquial/fisiopatologia , Doenças Cardiovasculares/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Fatores de Tempo , Adulto Jovem
2.
Lasers Med Sci ; 31(2): 393-6, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26714976

RESUMO

Glaucoma is the leading cause of irreversible blindness worldwide. The goal of this study was to describe our experience with the novel micropulse transscleral cyclophotocoagulation (MP-TSCPC; IRIDEX IQ810 Laser Systems, CA) in patients with advanced glaucoma. Patients with advanced glaucoma who underwent MP-TSCPC were included in our study. Laser settings were 2000 mW of 810 nm infrared diode laser set on micropulse delivery mode. The laser was delivered over 360° for 100-240 s. The duty cycle was 31.3 %, which translated to 0.5 ms of "on time" and 1.1 ms of "off time." Surgical success was defined as an intraocular pressure (IOP) of 6-21 mmHg or a reduction of IOP by 20 % at the last follow-up visit. Failure was defined as an inability to meet the criteria for success or a need for incisional glaucoma surgery. Nineteen patients underwent MP-TSCPC with mean follow-up of 60.3 days. Mean IOP dropped from 37.9 mmHg preoperatively to 22.7 mmHg at last follow-up, representing a 40.1 % decrease. The success rate for initial treatment was 73.7 % (n = 14). Three patients underwent a second treatment, increasing the overall success rate to 89.5 % (n = 17). Four patients gained one line of vision, and four patients lost one line of vision. The novel MP-TSCPC laser had a high rate of surgical success after a short follow-up period in patients with advanced glaucoma. Further long-term evaluation and comparison to the traditional transscleral cyclophotocoagulation are warranted.


Assuntos
Glaucoma/patologia , Glaucoma/cirurgia , Fotocoagulação a Laser/métodos , Esclera , Idoso , Corpo Ciliar/efeitos da radiação , Feminino , Seguimentos , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular/efeitos da radiação , Lasers Semicondutores/uso terapêutico , Masculino , Resultado do Tratamento , Acuidade Visual/efeitos da radiação
3.
Am J Perinatol ; 32(8): 761-70, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25519198

RESUMO

BACKGROUND: Maternal-fetal medicine is a rapidly growing field requiring collaboration from many subspecialties. We provide an evidence-based estimate of capacity needs for our clinic, as well as demonstrate how simulation can aid in capacity planning in similar environments. METHODS: A Discrete Event Simulation of the Center for Fetal Diagnosis and Treatment and Special Delivery Unit at The Children's Hospital of Philadelphia was designed and validated. This model was then used to determine the time until demand overwhelms inpatient bed availability under increasing capacity. FINDINGS: No significant deviation was found between historical inpatient censuses and simulated censuses for the validation phase (p = 0.889). Prospectively increasing capacity was found to delay time to balk (the inability of the center to provide bed space for a patient in need of admission). With current capacity, the model predicts mean time to balk of 276 days. Adding three beds delays mean time to first balk to 762 days; an additional six beds to 1,335 days. CONCLUSION: Providing sufficient access is a patient safety issue, and good planning is crucial for targeting infrastructure investments appropriately. Computer-simulated analysis can provide an evidence base for both medical and administrative decision making in a complex clinical environment.


Assuntos
Simulação por Computador , Número de Leitos em Hospital/estatística & dados numéricos , Modelos Estatísticos , Atenção à Saúde , Humanos
4.
Med Phys ; 41(2): 022901, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24506648

RESUMO

PURPOSE: To use feed-forward active contours (snakes) to track and measure brachial artery vasomotion on ultrasound images recorded in both transverse and longitudinal views; and to compare the algorithm's performance in each view. METHODS: Longitudinal and transverse view ultrasound image sequences of 45 brachial arteries were segmented by feed-forward active contour (FFAC). The segmented regions were used to measure vasomotion artery diameter, cross-sectional area, and distention both as peak-to-peak diameter and as area. ECG waveforms were also simultaneously extracted frame-by-frame by thresholding a running finite-difference image between consecutive images. The arterial and ECG waveforms were compared as they traced each phase of the cardiac cycle. RESULTS: FFAC successfully segmented arteries in longitudinal and transverse views in all 45 cases. The automated analysis took significantly less time than manual tracing, but produced superior, well-behaved arterial waveforms. Automated arterial measurements also had lower interobserver variability as measured by correlation, difference in mean values, and coefficient of variation. Although FFAC successfully segmented both the longitudinal and transverse images, transverse measurements were less variable. The cross-sectional area computed from the longitudinal images was 27% lower than the area measured from transverse images, possibly due to the compression of the artery along the image depth by transducer pressure. CONCLUSIONS: FFAC is a robust and sensitive vasomotion segmentation algorithm in both transverse and longitudinal views. Transverse imaging may offer advantages over longitudinal imaging: transverse measurements are more consistent, possibly because the method is less sensitive to variations in transducer pressure during imaging.


Assuntos
Artéria Braquial/diagnóstico por imagem , Artéria Braquial/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Movimento , Pressão , Transdutores , Ultrassonografia/instrumentação , Variações Dependentes do Observador , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa