Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Magn Reson Med ; 71(3): 1197-209, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23580479

RESUMO

PURPOSE: Voltage-based device-tracking (VDT) systems are commonly used for tracking invasive devices in electrophysiological cardiac-arrhythmia therapy. During electrophysiological procedures, electro-anatomic mapping workstations provide guidance by integrating VDT location and intracardiac electrocardiogram information with X-ray, computerized tomography, ultrasound, and MR images. MR assists navigation, mapping, and radiofrequency ablation. Multimodality interventions require multiple patient transfers between an MRI and the X-ray/ultrasound electrophysiological suite, increasing the likelihood of patient-motion and image misregistration. An MRI-compatible VDT system may increase efficiency, as there is currently no single method to track devices both inside and outside the MRI scanner. METHODS: An MRI-compatible VDT system was constructed by modifying a commercial system. Hardware was added to reduce MRI gradient-ramp and radiofrequency unblanking pulse interference. VDT patches and cables were modified to reduce heating. Five swine cardiac VDT electro-anatomic mapping interventions were performed, navigating inside and thereafter outside the MRI. RESULTS: Three-catheter VDT interventions were performed at >12 frames per second both inside and outside the MRI scanner with <3 mm error. Catheters were followed on VDT- and MRI-derived maps. Simultaneous VDT and imaging was possible in repetition time >32 ms sequences with <0.5 mm errors, and <5% MRI signal-to-noise ratio (SNR) loss. At shorter repetition times, only intracardiac electrocardiogram was reliable. Radiofrequency heating was <1.5°C. CONCLUSION: An MRI-compatible VDT system is feasible.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Pletismografia de Impedância/instrumentação , Próteses e Implantes , Tecnologia sem Fio/instrumentação , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Projetos Piloto , Suínos
2.
Circ Arrhythm Electrophysiol ; 7(1): 99-106, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24363351

RESUMO

BACKGROUND: In the absence of overt structural heart disease, most left ventricular outflow tract ventricular tachycardias (VTs) have a focal origin and are benign. We hypothesized that multiple morphologies (MMs) of inducible left ventricular outflow tract VT may indicate a scar-related VT that can mimic idiopathic VT. METHODS AND RESULTS: Of 54 consecutive patients referred for ablation of sustained outflow tract VT without overt structural heart disease, 24 had left ventricular outflow tract VT, 10 had MM VT, and 14 had a single VT (SM). The MM group were older (70.3±4.3 versus 53.9±15.9 years; P=0.004), had more hypertension (100% versus 29%; P=0.0006), and had longer PR intervals and QRS durations compared with the SM group. In contrast to the SM group, the MM group VTs had features consistent with reentry, including induction by programmed stimulation without isoproterenol, entrainment in some, and abnormal electrograms in the periaortic area. Periaortic region voltages suggested scar in the MM group, but not in the SM group. MRI in 2 MM patients was consistent with scar, but not in 10 SM patients. Longer radiofrequency applications were required in the MM group than in the SM group. At a median follow-up of 9.7 (3.0-32.0) months, recurrences tended to be more frequent in the MM group than in the SM group (70% versus 22%; P=0.07). CONCLUSIONS: VTs from small regions of periaortic scar can mimic idiopathic VT but are suggested by multiple VT morphologies and are more difficult to ablate. Whether these patients are at greater risk, as feared for other scar-related VTs, warrants further study.


Assuntos
Cicatriz/complicações , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia Reciprocante/etiologia , Taquicardia Ventricular/etiologia , Potenciais de Ação , Adulto , Idoso , Estimulação Cardíaca Artificial , Ablação por Cateter , Cicatriz/diagnóstico , Cicatriz/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Cinética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Taquicardia Reciprocante/diagnóstico , Taquicardia Reciprocante/fisiopatologia , Taquicardia Reciprocante/cirurgia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento , Imagens com Corantes Sensíveis à Voltagem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa