Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Curr Heart Fail Rep ; 20(1): 12-23, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36701019

RESUMO

PURPOSE OF REVIEW: This review offers an overview of the evidence in diagnostic and therapeutic applications of remote monitoring implantable devices. RECENT FINDINGS: Remote monitoring of cardiac implantable devices has become more and more popular in recent years as healthcare is moving towards a more patient centralized system. For heart failure patients with an ICD or pacemaker, there is controversial evidence regarding improvements in the clinical outcome, e.g., reduction of hospitalization rates or overall mortality. New developments as hemodynamic remote monitoring via measurement of the pulmonary artery pressure are promising technical achievements showing encouraging results. In cardiac remote monitoring of syncope and arrhythmias, implantable loop recorder plays an important role in diagnostic algorithms. Although there is controversial evidence according to remote monitoring of implantable devices, its use is rapidly expanding, giving healthcare providers the opportunity to react promptly to worsening of their patients. Adequate evaluation of the data created by remote monitoring systems remains an unsolved challenge of contemporary healthcare services.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Marca-Passo Artificial , Humanos , Insuficiência Cardíaca/terapia , Arritmias Cardíacas/terapia , Eletrocardiografia/métodos
2.
Europace ; 21(6): 961-969, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30809649

RESUMO

AIMS: Non-compaction cardiomyopathy (NCCM) is associated with high rates of mortality and morbidity. Knowledge regarding risk stratification, arrhythmogenesis, therapy, and prognosis is limited. The aim of this study was to analyse the outcome of patients suffering from NCCM and ventricular arrhythmias (VAs) focusing on a treatment with implantable cardioverter-defibrillator (ICD) therapy and catheter ablation. METHODS AND RESULTS: We conducted a multicentre observational study on 18 patients with NCCM, who underwent ICD implantation for secondary (n = 12) and primary (n = 6) prevention. In patients with multiple symptomatic episodes of VAs catheter ablation was performed. During a follow-up of 62 ± 42 months, 12 patients (67%) presented with appropriate ICD therapies [ventricular tachycardia (VT): n = 8; ventricular fibrillation (VF): n = 4; VT/VF: n = 3]. Ten patients underwent catheter ablation for VT/VF. Solely endocardial ablation was conducted in eight patients, and in two patients endo- and epicardial ablation was performed within the same procedure. Acute procedural success was achieved in 9/10 patients. Ventricular tachycardia recurrence was observed in two patients and the median arrhythmia free interval was 9.5 months (interquartile range 5.3-21 months). One patient underwent reablation, four patients died due to the underlying NCCM, and one patient received a left ventricular assist device. CONCLUSION: Ventricular arrhythmias are common in patients suffering from NCCM and ICD therapy may be effective for primary and secondary prevention. In our cohort, consisting of patients with multiple VA episodes and recurrent ICD therapy, catheter ablation offered a safe and effective therapeutically option.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Cardiopatias Congênitas/complicações , Taquicardia Ventricular/prevenção & controle , Adulto , Idoso , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
Herzschrittmacherther Elektrophysiol ; 34(4): 339-350, 2023 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-37917360

RESUMO

Lead extraction due to infection or lead dysfunction has become more important in recent years. Patients with high risk of severe and life-threatening complications should only undergo surgery in experienced centers where appropriate personnel and equipment are available. In this review, different techniques and methods to safely and successfully perform transvenous lead extraction are summarized.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Estudos Retrospectivos
4.
Eur Heart J ; 32(2): 158-68, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21088011

RESUMO

AIMS: Recent genome-wide association (GWA) studies identified 10 chromosomal loci for coronary artery disease (CAD) or myocardial infarction (MI). However, these loci explain only a small proportion of the genetic variability of these pertinent diseases. We sought to identify additional CAD/MI loci by applying a three-stage approach. METHODS AND RESULTS: We genotyped n = 1157 MI cases and n = 1748 controls from a population-based study population [German MI Family Study (GerMIFS) III (KORA)] with genome-wide SNP arrays. At this first stage, n = 462 SNPs showed association with MI at P<1 × 10(-3) in two-sided logistic regression. In a second stage, 415 of these SNPs were evaluated in silico in two independent GWA samples, the GerMIFS I (875 cases/1644 controls) and GerMIFS II (1222 cases/1298 controls). Nine SNPs, representing three regions, displayed consistent replication in this in silico analysis (P<0.05 for each GWA sample): five SNPs at 9p21.3, a well-known CAD/MI locus, two SNPs at 10p11.21, and two SNPs at 2p24.3. Wet-lab replication, i.e. the third stage, of SNP rs3739998 (representing the novel locus at 10p11.21, p.S1002T in the KIAA1462 gene) in additional 5790 cases and 5302 controls confirmed the association (P=9.54 × 10(-4)), but not for the 2p24.3 locus. The combined P-value across all stages for SNP rs3739998 is P=1.27 × 10(-11) [odds ratio (OR) = 1.15 (1.11-1.20)]. CONCLUSION: Analysis of a GWA study followed by in silico and wet-lab replication steps identified the KIAA1462 gene, encoding a yet uncharacterized protein, on chromosome 10p11.23 with genome-wide significant association for CAD/MI. Further studies are needed to characterize the functional role of this locus in the aetiology of these diseases.


Assuntos
Cromossomos Humanos Par 10/genética , Doença da Artéria Coronariana/genética , Infarto do Miocárdio/genética , Polimorfismo de Nucleotídeo Único/genética , Adulto , Moléculas de Adesão Celular/genética , Cromossomos Humanos Par 9/genética , Feminino , Estudo de Associação Genômica Ampla , Genótipo , Técnicas de Genotipagem/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Linhagem , Fatores de Risco , Adulto Jovem
5.
Clin Res Cardiol ; 105(6): 535-43, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26683202

RESUMO

BACKGROUND: Percutaneous edge-to-edge mitral valve reconstruction (PMVR) has emerged as a treatment option in patients with severe mitral regurgitation not considered suitable candidates for surgery. The majority of PMVR procedures are performed under general anesthesia (GA), although deep sedation (DS) appears to be an attractive alternative. We thus sought to assess the impact on intensive care unit (ICU) length of stay, efficacy, and safety of DS in comparison to GA in patients undergoing PMVR using the MitraClip(®) system. METHODS: Sixty consecutive patients underwent PMVR procedures at two centers. The first 30 patients were treated by GA followed by 30 patients undergoing DS under different settings. The primary clinical endpoint was ICU length of stay. The primary efficacy endpoint included procedural success and procedural duration. The safety endpoint was defined as a composite of death, stroke, cardiogenic shock, moderate and severe bleeding as well as pneumonia. RESULTS: The ICU length of stay was significantly shorter in the DS group in comparison to GA patients (p = 0.001). The hospital length of stay did not differ following DS in comparison to GA (p = 0.96). Procedural success was high in both groups (100 versus 96.7 %, p = 0.34) at similar procedural duration time (p = 0.60). No difference between GA and DS was observed with respect to the occurrence of the combined safety endpoint (p = 0.47). CONCLUSIONS: In comparison to GA, DS reduces the ICU length of stay in PMVR without negative effects on safety and efficacy. Prospective randomized trials are needed to confirm these findings.


Assuntos
Anestesia Geral , Cateterismo Cardíaco/instrumentação , Sedação Profunda , Insuficiência da Valva Mitral/terapia , Idoso , Idoso de 80 Anos ou mais , Anestesia Geral/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Sedação Profunda/efeitos adversos , Desenho de Equipamento , Feminino , Alemanha , Humanos , Unidades de Terapia Intensiva , Tempo de Internação , Masculino , Insuficiência da Valva Mitral/diagnóstico , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa