Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Phys Rev Lett ; 112(11): 115001, 2014 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-24702380

RESUMO

With fusion device performance hinging on the edge pedestal pressure, it is imperative to experimentally understand the physical mechanism dictating the pedestal characteristics and to validate and improve pedestal predictive models. This Letter reports direct evidence of density and magnetic fluctuations showing the stiff onset of an edge instability leading to the saturation of the pedestal on the Alcator C-Mod tokamak. Edge stability analyses indicate that the pedestal is unstable to both ballooning mode and kinetic ballooning mode in agreement with observations.

2.
Phys Rev Lett ; 110(6): 065006, 2013 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-23432265

RESUMO

New observations of the formation and dynamics of long-lived impurity-induced helical "snake" modes in tokamak plasmas have recently been carried out on Alcator C-Mod. The snakes form as an asymmetry in the impurity ion density that undergoes a seamless transition from a small helically displaced density to a large crescent-shaped helical structure inside q<1, with a regularly sawtoothing core. The observations show that the conditions for the formation and persistence of a snake cannot be explained by plasma pressure alone. Instead, many features arise naturally from nonlinear interactions in a 3D MHD model that separately evolves the plasma density and temperature.

3.
Phys Rev Lett ; 111(12): 125003, 2013 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-24093268

RESUMO

Application of lower hybrid (LH) current drive in tokamak plasmas can induce both co- and countercurrent directed changes in toroidal rotation, depending on the core q profile. For discharges with q(0) <1, rotation increments in the countercurrent direction are observed. If the LH-driven current is sufficient to suppress sawteeth and increase q(0) above unity, the core toroidal rotation change is in the cocurrent direction. This change in sign of the rotation increment is consistent with a change in sign of the residual stress (the divergence of which constitutes an intrinsic torque that drives the flow) through its dependence on magnetic shear.

4.
Rev Sci Instrum ; 94(2): 023509, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36859004

RESUMO

A suite of multi-channel resistive bolometers has been implemented to measure the total radiation from Mega Amp Spherical Tokamak Upgrade plasmas, with cameras covering the core plasma and lower divertor chamber. Data are digitized and processed using novel field-programmable gate array-based electronics, offering improved compactness and new operational capabilities. A synthetic diagnostic has been developed to explore the quality of 2D reconstructions available from the system and to quantify the uncertainty on quantities such as the total radiated power. Measurements in the first campaign have demonstrated correct functioning of the diagnostic while also highlighting issues with electrical noise and some failure mechanisms of the detectors, as well as significant neutral beam fast-particle losses.

5.
Rev Sci Instrum ; 93(12): 123515, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36586957

RESUMO

A fiber optic bolometer (FOB) was demonstrated observing a fusion plasma for the first time at the DIII-D tokamak. A FOB uses a fiber optics-based interferometric technique that is designed to have a high sensitivity to temperature changes [75 mK/(W/m2) responsivity in high vacuum with 0.38 mK noise level] with a negligible susceptibility to electromagnetic interference (EMI) that can be problematic for resistive bolometers in a tokamak environment. A single-channel test apparatus was installed on DIII-D consisting of a measurement FOB and shielded reference FOB. The single-channel FOB showed a negligible increase in the noise level during typical plasma operations (0.39 mK) compared to the benchtop results (0.38 mK), confirming an insignificant EMI impact to the FOB. Comparisons to DIII-D resistive bolometers showed good agreement with the single-channel FOB, indicating that the FOB is comparable to a resistive bolometer when the impulse calibration is applied. The noise-equivalent power density of the calibrated FOB during a plasma operation was 0.55 W/m2 with an average sampling time of 20 ms. The major potential effect of ionizing radiation on the FOB would be the radiation-induced attenuation, which can be efficiently compensated for by adjusting the probing light power.

6.
Phys Rev Lett ; 106(21): 215001, 2011 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-21699305

RESUMO

Intrinsic rotation has been observed in I-mode plasmas from the C-Mod tokamak, and is found to be similar to that in H mode, both in its edge origin and in the scaling with global pressure. Since both plasmas have similar edge ∇T, but completely different edge ∇n, it may be concluded that the drive of the intrinsic rotation is the edge ∇T rather than ∇P. Evidence suggests that the connection between gradients and rotation is the residual stress, and a scaling for the rotation from conversion of free energy to macroscopic flow is calculated.

7.
Phys Rev Lett ; 107(26): 265001, 2011 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-22243160

RESUMO

Direction reversals of intrinsic toroidal rotation have been observed in diverted Alcator C-Mod Ohmic L-mode plasmas following electron density ramps. For low density discharges, the core rotation is directed cocurrent, and reverses to countercurrent following an increase in the density above a certain threshold. Such reversals occur together with a decrease in density fluctuations with 2 cm(-1)≤k(θ)≤11 cm(-1) and frequencies above 70 kHz. There is a strong correlation between the reversal density and the density at which the Ohmic L-mode energy confinement changes from the linear to the saturated regime.

8.
Rev Sci Instrum ; 92(2): 023502, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33648156

RESUMO

This paper presents techniques for evaluating the radiated power in JET disruptions. Disrupting plasmas are shown to have non-axisymmetric radiation profiles, motivating the re-evaluation of the standard techniques for calculating the total radiated power at JET using bolometry. Four single-channel bolometers at different toroidal locations are exploited to quantify the radiation asymmetry. Toroidal radiation peaking factors integrated over the entire disruption of up to 1.5 have been observed when varying the quantity of neon in pellets used in disruptions mitigated by shattered pellet injection. Using synthetic bolometer diagnostics developed with the Cherab spectroscopy modeling framework, we can estimate the systematic error on total power calculations for relevant radiation profiles and improve estimates of the total radiated power. We show that the component of the systematic error on the total power due to the poloidal radiation profile can be reduced from 70% to 10% with suitable assumptions about the structure of the poloidal profile.

9.
Rev Sci Instrum ; 89(10): 10J128, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399927

RESUMO

The upgrade to the National Spherical Torus eXperiment (NSTX-U) [J. Menard et al., Nucl. Fusion 52, 083015 (2012)] increases the injected neutral beam power up to 12 MW and the plasma current up to Ip = 2 MA for plasma durations up to 5 s. The graphite plasma facing components have been re-designed to handle greater heat and energy fluxes than were seen in NSTX using a castellated design. We present the experimental testing and validation of a castellated graphite target, similar to the prototype tile design, instrumented with thermocouples at various depths in the castellation. During testing, incident heat flux is provided by a programmed electron beam system and surface temperatures are measured via infrared thermography directly viewing the target surface. It was found that the thermocouple response scaled linearly with the measured surface temperature rise regardless of thermocouple depth in the castellation. A sensitivity of 14.3 °C/kJ of deposited energy was found when treating individual castellations as a semi-infinite solid.

10.
Rev Sci Instrum ; 89(10): 103507, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399930

RESUMO

A prototype of an infrared imaging bolometer (IRVB) was successfully tested on the Alcator C-Mod tokamak at the end of its 2016 campaign. The IRVB method interprets the power radiated from the plasma by measuring the temperature rise of a thin, ∼2 µm, Pt absorber that is placed in the torus vacuum and exposed, using a pinhole camera, to the full-spectrum of plasma's photon emission. The IRVB installed on C-Mod viewed the poloidal cross section of the core plasma and observed Ohmic and ion cyclotron range of frequency (ICRF)-heated plasmas. Analysis of total radiated power and on-axis emissivity from IRVB is summarized, and quantitative comparisons made to data from both resistive bolometers and AXUV diodes. IRVB results are clearly within a factor of two, but additional effort is needed for it to be used to fully support power exhaust research. The IRVB is shown to be immune to electromagnetic interference from ICRF which strongly impacts C-Mod's resistive bolometers. Results of the bench-top calibration are summarized, including a novel temperature calibration method useful for IRVBs.

11.
Rev Sci Instrum ; 89(10): 10F107, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399931

RESUMO

An in situ wavelength calibration system for the X-ray Imaging Crystal Spectrometer (XICS) on W7-X has been developed to provide routine calibration between plasma shots. XICS is able to determine plasma flow profiles by measuring the Doppler shift of x-ray line emission from highly charged impurity species. A novel design is described that uses an x-ray tube with a cadmium anode placed in front of the diffracting spherically bent crystal. This arrangement provides calibration lines over the full detector extent for both the Ar16+ and Ar17+/Fe24+ spectrometer channels. This calibration system can provide a relative wavelength accuracy of 3 × 10-7 Å across the full spatial extent of the detector, which corresponds to 50 m/s in the W7-X system. An absolute wavelength calibration of 1 × 10-5 Å is expected, corresponding to 1 km/s, based on the current known accuracy of the calibration wavelength and the achievable measurement of the absolute positioning of the hardware. This calibration system can be used to independently calibrate XICS systems on both stellarators and tokamaks, without the need for special plasma conditions often used for calibration, such as locked modes on tokamaks. Experimental and simulated results are shown along with expected results, and the complete design of the calibration hardware that is to be installed in the W7-X XICS system.

12.
Rev Sci Instrum ; 87(11): 11E708, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910644

RESUMO

Measurements of radiated power in magnetically confined plasmas are important for exhaust studies in present experiments and expected to be a critical diagnostic for future fusion reactors. Resistive bolometer sensors have long been utilized in tokamaks and helical devices but suffer from electromagnetic interference (EMI). Results are shown from initial testing of a new bolometer concept based on fiber-optic temperature sensor technology. A small, 80 µm diameter, 200 µm long silicon pillar attached to the end of a single mode fiber-optic cable acts as a Fabry-Pérot cavity when broadband light, λo ∼ 1550 nm, is transmitted along the fiber. Changes in temperature alter the optical path length of the cavity primarily through the thermo-optic effect, resulting in a shift of fringes reflected from the pillar detected using an I-MON 512 OEM spectrometer. While initially designed for use in liquids, this sensor has ideal properties for use as a plasma bolometer: a time constant, in air, of ∼150 ms, strong absorption in the spectral range of plasma emission, immunity to local EMI, and the ability to measure changes in temperature remotely. Its compact design offers unique opportunities for integration into the vacuum environment in places unsuitable for a resistive bolometer. Using a variable focus 5 mW, 405 nm, modulating laser, the signal to noise ratio versus power density of various bolometer technologies are directly compared, estimating the noise equivalent power density (NEPD). Present tests show the fiber-optic bolometer to have NEPD of 5-10 W/m2 when compared to those of the resistive bolometer which can achieve <0.5 W/m2 in the laboratory, but this can degrade to 1-2 W/m2 or worse when installed on a tokamak. Concepts are discussed to improve the signal to noise ratio of this new fiber-optic bolometer by reducing the pillar height and adding thin metallic coatings, along with improving the spectral resolution of the interrogator.

13.
Rev Sci Instrum ; 87(11): 11E320, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910559

RESUMO

Soft x-ray detection with the new "multi-energy" PILATUS3 detector systems holds promise as a magnetically confined fusion (MCF) plasma diagnostic for ITER and beyond. The measured x-ray brightness can be used to determine impurity concentrations, electron temperatures, ne2Zeff products, and to probe the electron energy distribution. However, in order to be effective, these detectors which are really large arrays of detectors with photon energy gating capabilities must be precisely calibrated for each pixel. The energy-dependence of the detector response of the multi-energy PILATUS3 system with 100 K pixels has been measured at Dectris Laboratory. X-rays emitted from a tube under high voltage bombard various elements such that they emit x-ray lines from Zr-Lα to Ag-Kα between 1.8 and 22.16 keV. Each pixel on the PILATUS3 can be set to a minimum energy threshold in the range from 1.6 to 25 keV. This feature allows a single detector to be sensitive to a variety of x-ray energies, so that it is possible to sample the energy distribution of the x-ray continuum and line-emission. PILATUS3 can be configured for 1D or 2D imaging of MCF plasmas with typical spatial energy and temporal resolution of 1 cm, 0.6 keV, and 5 ms, respectively.

14.
Rev Sci Instrum ; 87(11): 11D402, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910411

RESUMO

The InfraRed Video Bolometer (IRVB) is a powerful tool to measure radiated power in magnetically confined plasmas due to its ability to obtain 2D images of plasma emission using a technique that is compatible with the fusion nuclear environment. A prototype IRVB has been developed and installed on NSTX-U to view the lower divertor. The IRVB is a pinhole camera which images radiation from the plasma onto a 2.5 µm thick, 9 × 7 cm2 Pt foil and monitors the resulting spatio-temporal temperature evolution using an IR camera. The power flux incident on the foil is calculated by solving the 2D+time heat diffusion equation, using the foil's calibrated thermal properties. An optimized, high frame rate IRVB, is quantitatively compared to results from a resistive bolometer on the bench using a modulated 405 nm laser beam with variable power density and square wave modulation from 0.2 Hz to 250 Hz. The design of the NSTX-U system and benchtop characterization are presented where signal-to-noise ratios are assessed using three different IR cameras: FLIR A655sc, FLIR A6751sc, and SBF-161. The sensitivity of the IRVB equipped with the SBF-161 camera is found to be high enough to measure radiation features in the NSTX-U lower divertor as estimated using SOLPS modeling. The optimized IRVB has a frame rate up to 50 Hz, high enough to distinguish radiation during edge-localized-modes (ELMs) from that between ELMs.

15.
Rev Sci Instrum ; 87(11): 11D410, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910451

RESUMO

The infrared imaging video bolometer (IRVB) measures plasma radiated power images using a thin metal foil. Two different designs with a tangential view of NSTX-U are made assuming a 640 × 480 (1280 × 1024) pixel, 30 (105) fps, 50 (20) mK, IR camera imaging the 9 cm × 9 cm × 2 µm Pt foil. The foil is divided into 40 × 40 (64 × 64) IRVB channels. This gives a spatial resolution of 3.4 (2.2) cm on the machine mid-plane. The noise equivalent power density of the IRVB is given as 113 (46) µW/cm2 for a time resolution of 33 (20) ms. Synthetic images derived from Scrape Off Layer Plasma Simulation data using the IRVB geometry show peak signal levels ranging from ∼0.8 to ∼80 (∼0.36 to ∼26) mW/cm2.

16.
Biochim Biophys Acta ; 1081(3): 274-8, 1991 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-1847833

RESUMO

A monoclonal antibody (1A-LDR1) against sulfidopeptide leukotrienes (LT) is described. The mAb shows a nearly identical detection limit of about 0.04 ng for LTC4, LTD4, LTE4 and NacLTE4 in standard fluid phase RIA. Steric modifications, however, diminish the sensitivity, as determined for the examples 5-epi-LTC4, 6-epi-LTC4, 5,6-epi-LTC4 and 11-trans-LTC4. No crossreactivity could be observed for LTB4. Crossreactions with components of the LT peptide chain such as L-cysteine or glutathione, as well as with arachidonic acid, were not detectable. In assessing the accuracy of the LT-RIA, recovery experiments with supernatants of mouse peritoneal macrophages and incubates of gastric mucosa showed a good correlation of r = 0.993 and 0.990, respectively. Results of an inhibition experiment with mouse peritoneal macrophages, incubated with several concentrations of indomethacin and nordihydroguaiaretic acid (NDGA), support the reliability of RIA and ELISA. The new LT-mAB allows an almost complete detection of peptide leukotrienes in one assay.


Assuntos
Anticorpos Monoclonais , SRS-A/análogos & derivados , SRS-A/imunologia , Animais , Calcimicina/farmacologia , Reações Cruzadas , Ensaio de Imunoadsorção Enzimática , Hibridomas , Indometacina/farmacologia , Leucotrieno E4 , Macrófagos/efeitos dos fármacos , Masoprocol/farmacologia , Camundongos , Camundongos Endogâmicos BALB C , Radioimunoensaio
17.
FEBS Lett ; 232(1): 46-50, 1988 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-3130275

RESUMO

A monoclonal antibody against thromboxane B2 which may be used in standard fluid phase radioimmunoassays with a detection limit of around 40 pg and a binding affinity of 1.98 X 10(9) M-1 is described. Limited crossreactivity could be observed only with structurally closely related compounds such as 2,3-dinor-thromboxane B2 (8.9%), thromboxane B1 (15.7%) and thromboxane B3 (39.7%). Detectable crossreactivity with 11-dehydro-thromboxane B2, omega-carboxy-thromboxane B2, omega-hydroxy-thromboxane B2, prostaglandins of the D-, E- and F-type as well as metabolites of prostacyclin was lacking. The monoclonal anti-thromboxane B2 antibody proved well suited for measuring the thromboxane B2 content in tissue culture supernatants as well as in human serum.


Assuntos
Anticorpos Monoclonais/imunologia , Tromboxano B2/imunologia , Animais , Afinidade de Anticorpos , Especificidade de Anticorpos , Ácido Araquidônico , Ácidos Araquidônicos/farmacologia , Humanos , Ibuprofeno/farmacologia , Imidazóis/farmacologia , Imunoglobulina G/imunologia , Indometacina/farmacologia , Camundongos , Camundongos Endogâmicos BALB C , Agregação Plaquetária/efeitos dos fármacos , Radioimunoensaio , Tromboxano A2/imunologia , Tromboxano A2/fisiologia , Tromboxano B2/análogos & derivados , Tromboxano B2/análise
18.
FEBS Lett ; 186(1): 46-50, 1985 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-3859419

RESUMO

Polyclonal antisera against prostaglandins (PGs) are widely used for the assessment of the biological role of these mediators, but even the most specific contain antibodies against the major metabolites and degradation products of the haptens employed. To overcome this inherent problem we produced monoclonal antibodies (mAs) against PGE2, PGF2 alpha and 6-keto-PGF1 alpha using the somatic cell hybridization technique. The mAs against 6-keto-PGF1 alpha and PGF2 alpha proved to be highly specific, but allowed only for moderate detection limits (1-2 ng) in conventional fluid phase radioimmunoassays (RIAs). One of the mAs against PGE2 permitted a 100-fold improvement in the detection limit while being almost devoid of cross-reactivity with metabolites and other structurally related PGs. These results show that highly specific mAs against PGs can be produced to improve the available RIA technique for PG quantification.


Assuntos
6-Cetoprostaglandina F1 alfa/imunologia , Anticorpos Monoclonais/imunologia , Prostaglandinas E/imunologia , Prostaglandinas F/imunologia , Animais , Especificidade de Anticorpos , Dinoprosta , Dinoprostona , Feminino , Camundongos , Camundongos Endogâmicos BALB C , Radioimunoensaio
19.
Arch Ophthalmol ; 106(6): 740-4, 1988 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-3369996

RESUMO

We performed a prospective study evaluating the incidence of angiographic cystoid macular edema (CME) following extracapsular cataract extraction and posterior chamber intraocular lens implantation. Of the 162 eyes in the study, 141 were randomized into either a primary capsulotomy or a capsule intact group. The remaining eyes were not randomized due to intraoperative surgical complications, but they were included in the follow-up studies. Six weeks after surgery, angiographic CME was documented in 24% of the capsulotomy group and in 16% of the capsule intact group. The differences were not statistically significant. Including nonrandomized cases reduced the overall incidence of angiographic CME and the difference between the two groups. Angiographic CME was usually not extensive, and it was associated with a visual acuity less than 20/40 in 2.5% of eyes six weeks postoperatively. A subgroup of 120 eyes was followed up for approximately six months, when angiographic CME was present in 4% of the capsulotomy and capsule intact groups.


Assuntos
Extração de Catarata , Lentes Intraoculares , Edema Macular/etiologia , Idoso , Angiofluoresceinografia , Humanos , Edema Macular/diagnóstico , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Estudos Prospectivos , Distribuição Aleatória
20.
Life Sci ; 49(12): 881-8, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1875796

RESUMO

Antioxidants play an important role in the regulation of phospholipid hydrolysis and arachidonate metabolism. Supplementation of cultured human mesangial cells with selenium resulted in suppression of phospholipase A2-activity and significantly increased production of three major prostaglandins. However, prostacyclin synthesis benefits most from selenium supplementation, suggesting that there is a specific action of selenium-dependent glutathione peroxidase on this pathway. Like in endothelial cells, production of platelet activating factor is significantly inhibited by selenium supplementation.


Assuntos
Mesângio Glomerular/metabolismo , Fosfolipases A/metabolismo , Prostaglandinas/biossíntese , Selênio/farmacologia , Células Cultivadas , Mesângio Glomerular/efeitos dos fármacos , Mesângio Glomerular/enzimologia , Glutationa Peroxidase/metabolismo , Humanos , Fosfolipases A2 , Fator de Ativação de Plaquetas/metabolismo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa